1.
A cobalt(II) tetrakisphenylporphyrin (Co(II)TPP) film modified glassy carbon electrode (Co(II)TPP-GCE) was prepared by just coating Co(II)TPP solution on the surface of the electrode. It can be used for the simultaneous determination of ascorbic acid and uric acid. The anodic peaks of AA and UA can be separated well. Owing to the strongly hydrophobic property of porphyrin, the modified electrode has good stability and long life. The linear range for UA and AA were 2.0 x 10(-6)-1.0 x 10(-4) M and 9.0 x 10(-6)-2.0 x 10(-3) M with detection limits of 5.0 x 10(-7) and 5.0 x 10(-6) M, respectively. Furthermore, metalloporphyrins of other kinds were also used to construct modified electrodes. Their performances were inferior compared with that of the Co(II)TPP modified electrode.  相似文献   

2.
The electrocatalytic oxidation of aspirin and acetaminophen on nanoparticles of cobalt hydroxide electrodeposited on the surface of a glassy carbon electrode in alkaline solution was investigated. The process of oxidation and the kinetics have been investigated using cyclic voltammetry, chronoamperometry, and steady-state polarization measurements. Voltammetric studies have indicated that in the presence of drugs, the anodic peak current of low valence cobalt species increases, followed by a decrease in the corresponding cathodic current. This indicates that drugs are oxidized on the redox mediator which is immobilized on the electrode surface via an electrocatalytic mechanism. With the use of Laviron’s equation, the values of anodic and cathodic electron-transfer coefficients and charge-transfer rate constant for the immobilized redox species were determined as α s,a = 0.72, α s,c = 0.30, and k s = 0.22 s−1. The rate constant, the electron transfer coefficient, and the diffusion coefficient involved in the electrocatalytic oxidation of drugs were reported. It was shown that by using the modified electrode, aspirin and acetaminophen can be determined by amperometric technique with detection limits of 1.88 × 10−6 and 1.83 × 10−6 M, respectively. By analyzing the content of acetaminophen and aspirin in bulk forms using chronoamperometric and amperometric techniques, the analytical utility of the modified electrode was achieved. The method was also proven to be valid for analyzing these drugs in urine samples.  相似文献   

3.
A glassy carbon electrode (GCE) modified with docosyltrimethylammonium chloride (DCTMACl) is used for simultaneous determination of dopamine (DA) and ascorbic acid (AA) using differential pulse voltammetry (DPV) technique in 0.10 mol·L?1 phosphate buffer solution of pH 5.0. The cationic surfactant DCTMACl modified film has a positive charge. DA exists as the positively charged species, whereas AA is the negatively charged one in the solution. Thus, at DCTMACl film-modified GCE, the oxidation peak potential of AA shifts toward less negative potential and the peak current of AA increases a little, while the oxidation peak potential of DA shifts toward more positive potential and peak current decreases greatly in comparison with that on bare electrode. The two anodic peaks are separated around 200 mV. Under optimal conditions, the catalytic peak currents obtained from DPV increase linearly with concentrations of DA and AA in the ranges of 1.0?×?10?5 to 1.0?×?10?3?mol·L?1. This electrode has good reproducibility, high stability in its voltammetric response, and low detection limit (micromolar) for both AA and DA. The modified electrode has been applied to the determination of DA and AA in injection.  相似文献   

4.
利用离子液体1-丁基-3-甲基咪唑四氟硼酸盐(BMIMBF4)对玻碳电极(GCE)进行修饰,制备了BMI-MBF4/GCE电极.在0.1mol/L的磷酸盐缓冲溶液中,采用循环伏安法研究了抗坏血酸在BMIMBF4/GCE电极和裸玻碳电极(GCE)上的电化学行为.结果表明,pH=5.7的磷酸盐缓冲溶液为最佳测定底液,最佳富集时间为120s;BMIMBF4/GCE对抗坏血酸的氧化反应有很好的电化学催化作用.抗坏血酸的氧化峰电流与其浓度在2.0×10-4~1.0×10-2 mol/L的范围内呈良好的线性关系,相对标准偏差为4.53%(n=5).  相似文献   

5.
聚赖氨酸修饰电极在抗坏血酸共存时测定肾上腺素   总被引:3,自引:0,他引:3  
在pH8.0磷酸盐缓冲溶液(PBS)中利用循环伏安法制备了聚赖氨酸修饰电极,在pH4.0 PBS中,聚赖氨酸膜对肾上腺素(EP)的电化学氧化具有明显的催化作用.利用循环伏安法测定EP还原峰电流可排除抗坏血酸(AA)干扰.肾上腺素还原峰电流与其浓度分别在6.3×10-7mol/L~1.0×10-5 mol/L与1.0×10-5mol/L~1.2×10-4 mol/L范围内呈良好线性关系,相关系数分别为0.9978与0.9975,;检出限(S/N=3)为7.2×10-8mol/L.该方法具有良好的灵敏度、选择性,已用于针剂样品分析.  相似文献   

6.
Li X  Chen M  Ma X 《Analytical sciences》2012,28(2):147-151
A graphene-modified glassy carbon electrode was fabricated via a drop-casting method, and applied to the electrochemical detection of epinephrine. The capacity of the graphene-modified glassy carbon electrode for the selective detection of epinephrine was confirmed in a sufficient amount of ascorbic acid (2 mmol L(-1)) by cyclic voltammetry. The modified electrode showed an excellent electrocatalytical effect on the oxidation of epinephrine. A pair of well-defined redox waves were observed in voltammograms of epinephrine in a phosphate buffered solution (pH 4.0). The peak potentials of epinephrine remained unchanged, and the oxidation peak currents showed a linear relation versus the epinephrine concentration in the range of 3.85 × 10(-7) - 1.31 × 10(-5) mol L(-1) and 1.31 × 10(-5) - 1.09 × 10(-4) mol L(-1) with a correlation coefficient as follows: i(pa1) = -4.25 × 10(-6) - 1.99c (mol L(-1)), R(1) = 0.9953; i(pa2) = -4.31 × 10(-5) - 0.315c (mol L(-1)), R(2) = 0.9988. Detection limit is estimated to be 8.9 × 10(-8) mol L(-1). Graphene-modified glassy carbon electrode was applied to epinephrine sample analysis, and the results were in good agreement with the standard values.  相似文献   

7.
This paper describes the simultaneous determination of ascorbic acid (AA), norepinephrine (NE) and uric acid (UA) using a graphene modified glassy carbon electrode (GME) in pH 4.0 phosphate buffer solution. The electrochemical behaviors of AA, NE and UA at a bare glassy carbon electrode (GCE) and the GME were studied by cyclic voltammetry. Bare GCE failed to resolve the voltammetric signals of AA, NE and UA in a mixture, whereas the GME not only resolved their voltammetric signals, but also exhibited excellent electrocatalytic activity towards their electrochemical oxidation. The oxidation peak currents of AA, NE and UA were linearly proportional to their concentrations over the range of 1.0.0–1000.0, 0.6–45.0 and 1.0–100.0 μM, respectively, and their detection limits were 1.2, 0.10 and 0.60 μM, respectively, The modified electrode is of excellent sensitivity and selectivity, and has been satisfactorily used for the simultaneous determination of AA, NE and UA in their ternary mixture.  相似文献   

8.
We report on an electrochemical sensor for the sensitive amperometric determination of ascorbic acid (AA). Aniline containing suspended silicotungstic acid and carbon nanotubes was electropolymerized on the surface of a glassy carbon electrode in a single step which provides a simple and controllable method and greatly improves the electrocatalytic oxidation of AA. The effects of scan rate, solution pH and working potential were studied. A linear relationship exists between the current measured and the concentration of AA in the range from 1 μM to 10 μM and 0.01 mM to 9 mM, with a limit of detection as low as 0.51 μM (S/N?=?3). The sensor is selective, stable and satisfyingly reliable in real sample experiments. In our eyes, it has a large potential for practical applications.
Figure
Aniline containing suspended silicotungstic acid and carbon nanotubes was electropolymerized on the surface of a glassy carbon electrode in a single step. Due to the novel properties of silicotungstic acid and carbon nanotubes doped in the polyaniline film, this sensor showed excellent analytical performance for the amperometric determination of ascorbic acid at a low potential.  相似文献   

9.
抗坏血酸(AA)即维生素C (Vc)广泛存在于食品、动物体液、组织及药品中,它能激化羟化酶,促进组织中胶原的形成,同时参与体内许多物质的代谢过程.传统的AA分析检测方法很多,如吸光光度法、荧光光度法、化学发光法、滴定分析法和电化学方法[1-2].  相似文献   

10.
The preparation and electrochemical properties of a glassy carbon (GC) electrode modified with cobaloxime complex were investigated. The complex of the type [CoIII(DO)(DOH)pn)Cl2] where (DO)(DOH)pn = N2,N2'-propanediylbis-2,3-butanedione-2-imine-3-oxime) was adsorbed irreversibly and strongly on the surface of preanodized glassy carbon electrode. Electrochemical behavior and stability of modified GC electrode were investigated by cyclic voltammetry. The electrocatalytic reduction of dioxygen has been studied using this modified glassy carbon electrode by cyclic voltammetry, chronoamperometry and rotating disk electrode voltammetry as diagnostic techniques. The modified electrode showed excellent eletrocatalytic ability for the reduction of dioxygen to hydrogen peroxide in acetate buffer (pH 4.0) with overpotential 1.0 V lower than the plain glassy carbon electrode. The formal potential for this modified electrode is not shifted to more negative potentials by repeated reduction-oxidation cycles in oxygen-saturated supporting electrolyte solution. The apparent electron transfer rate constant (kS), the transfer coefficent (alpha) and the catalytic rate constant of O2 reduction at a GC modified electrode were determined by cyclic voltammetry and rotating disk electrode voltammetry and were found to be around 2.6 s(-1), 0.33 and 2.25 x 10(4) M(-1) s(-1). Based on the results, a catalytic mechanism is proposed and discussed.  相似文献   

11.
Detection of dopamine (DA) in the presence of excess of ascorbic acid (AA) has been demonstrated using a conducting polymer matrix, poly (3,4-ethylenedioxythiophene) (PEDOT) film in neutral buffer (PBS 7.4) solution. The PEDOT film was deposited on a glassy carbon electrode by electropolymerization of EDOT from acetonitrile solution. Atomic force microscopy studies revealed that the electrodeposited film was found to be approximately 100 nm thick with a roughness factor of 2.6 nm. Voltammetric studies have shown catalytic oxidation of DA and AA on PEDOT modified electrode and can afford a peak potential separation of ∼0.2 V. It is speculated that the cationic PEDOT film interacts with the negatively charged ascorbate anion through favorable electrostatic interaction, which results in pre-concentration at a less anodic value. The positively charged DA tends to interact with the hydrophobic regions of PEDOT film through hydrophobic–hydrophobic interaction thus resulting in favorable adsorption on the polymer matrix. Further enhancement in sensitivity to micro molar level oxidation current for DA/AA oxidation was achieved by square wave voltammetry (SWV) which can detect DA at its low concentration of 1 μM in the presence of 1000 times higher concentration of AA (1 mM). Thus the PEDOT modified electrode exhibited a stable and sensitive response to DA in the presence of AA interference.  相似文献   

12.
Hu S  Xu C  Wang G  Cui D 《Talanta》2001,54(1):115-123
A new method for the determination of 4-nitrophenol(4-NP) by differential pulse voltammetry (DPV) based on adsorptive stripping technique was described. Cyclic voltammetry (CV) and linear scan voltammetry (LSV) were used in a comparative investigation into the electrochemical reduction of 4-NP at a Na-montmorillonite(SWy-2) and anthraquione (AQ) modified glassy carbon electrode. With this chemically modified electrode, 4-NP was first irreversibly reduced from phiNO(2) to phiNHOH at -0.78 V. A couple of well-defined redox peaks at +0.22 V (vs. SCE) were responsible for a two-electron redox peak between phiNHOH and phiNO. Studies on the effect of pH on the peak height and peak potential were carried out over the pH range 2.0-9.0 with the phosphate buffer solution. A pH of 3.4 was chosen as the optimum pH. The other experimental parameters, such as film thickness, accumulation time and potential etc. were optimized. Anodic peak currents were found to be linearly related to concentration of 4-NP over the range 0.3-45 mg l(-1), with a detection limit of 0.02 mg l(-1). The interference of organic and inorganic species on the voltammetric response have been studied. This modified electrode can be used to the determination of 4-NP in water samples.  相似文献   

13.
14.
The electrocatalytic oxidation of glucose was investigated on a nickel-basedchemically modified electrode (Ni(II)-curcumin) prepared by electropolymerization of Ni-curcumin complex (curcumin=1,7-bis[4-hydroxy-3-methoxyphenyl]-1,6-heptadiene-3,5-dione) in alkaline solution. Reaction kinetic and mechanism were investigated by using cyclic voltammetry (CV) and chronoamperometry (CA) techniques and steady-state polarization measurements. Cyclic voltammetry studies indicated that in the presence of glucose the anodic peak current of surface redox mediator was increased, followed by decrease in the corresponding cathodic current. This indicates that glucose was oxidized at the surface of this modified electrode. The results were explained based on the concept of electrocatalytic reactions that occur in this chemically modified electrode. The diffusion coefficient of glucose and the rate constant of the catalytic oxidation of glucose were found to be 6.7×10−6 cm2 s−1 and 6.5×103 M−1 s−1, respectively. It has shown that by using the Ni-curcumin modified electrode, glucose can be determined with good response and low detection limit.  相似文献   

15.
磺胺类抗菌药是一类允许在饲料中添加的兽用广谱抗菌药.它被广泛用于治疗家畜呼吸道、消化道细菌感染、猪萎缩性鼻炎、禽霍乱、伤寒等疾病[1].停药期用药或用药不当将导致动物食品中抗菌药残留超标.人们长期食用含磺胺类抗菌药残留超标的动物产品,将导致肝肾损伤和体内耐药菌株产生,危害到人们的身体健康和疾病治疗.  相似文献   

16.
研究了苦参碱(Matrine, MT) 在多壁碳纳米管修饰玻碳电极(MWCNT/GCE)上的电化学行为. 与GCE相比, MT在MWCNT/GCE上峰电位负移120 mV, 峰电流增大约2.5倍, 表明MWCNT/GCE对MT的电化学氧化具有良好的催化作用. 同时测定并计算了MT在MWCNT/GCE上的电极过程动力学参数: 电子转移系数α、电极反应速率常数ks、扩散系数D. 运用差分脉冲伏安法对苦参碱样品含量进行测定, 相对标准偏差为0.12%~2.9%, 加标回收率为98.4%~99.0%. 该方法可用于MT的电化学定量测定.  相似文献   

17.
Summary A new preconcentration and voltammetric determination method for cobalt(II) in aqueous solution with a chemically modified electrode is proposed. The accumulation behaviour and voltammetry of cobalt(II) has been investigated with a carbon paste electrode modified with cationexchanger and 1,10-phenanthroline. The electrochemical response is characterized with respect to carbon paste composition, pH, preconcentration time, cobalt(II) concentration and other variables. For a 3-min preconcentration time, the electrode gives good linearity for 1×10–7 to 4×10–6 mol/l Co(II), a detection limit of 8×10–8 mol/l. The response can be reproduced with a 4.0% relative standard deviation. The method is fairly free from many coexisting ions interferences. A rapid and convenient renewal procedure allows the use of a single electrode in multiple analytical determinations over several days. Satisfactory results are obtained for the determination of cobalt in a variety of certified standard reference materials.  相似文献   

18.
Electrocatalytic activity of gold and a gold-iridum binary system electro deposited onto the surface of a glassy carbon in oxidation of cysteine was studied. A method for flow-through-injection determination of cysteine was developed.  相似文献   

19.
本文表明用旋转涂层法制备的聚乙烯二茂铁(PVFc)薄膜电极在水溶液和乙腈中, 0.3~1.0V(vs.SCE)电位范围内均可呈现二茂铁(Fe)的氧化还原峰. PVFc薄膜电极对水溶液中的抗坏血酸(AH2)在较宽的pH范围和较宽的浓度范围内均有良好的电催化氧化作用,为EC平行催化过程。利用旋转圆盘电极进行了催化过程动力学分析,求出了催化反应动力学参数.PVFc薄膜电极的稳定性和催化稳定性都较好.在AH~2浓度6x10^-^2~6x10^-^6mol/L范围内,催化峰电流与AH~2浓度呈良好的线性关系,有应用于分析AH~2的意义。  相似文献   

20.
A Nafion/ruthenium oxide pyrochlore chemically modified electrode (CME) was used for the selective determination of dopamine (DA) in the presence of a high concentration of ascorbic acid by square-wave voltammetry. Compared to a bare glassy carbon electrode, the CME exhibits an apparent shift of the oxidation potentials in cathodic direction and a marked enhancement of the current response. The selective sensing of DA is achieved by combining the electrocatalytic function of the ruthenium oxide pyrochlore catalyst with the charge-exclusion and preconcentration features of Nation. With a preconcentration time of 60 s at a potential of −0.3 V (vs. Ag/AgCl), linear calibration plots are obtained for dopamine in 0.1 M, phosphate buffer (pH 7.4) over 0–20 μM with a detection limit (3σ) of 0.1 μM.  相似文献   