首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Using isocratic retention parameters, the gradient elution retention time for several proteins has been calculated. The gradient retention time calculation is based on fitting the isocratic retention data to an equation of the form: log k' = m log (1/[Ca2+]) + log K and on applying well-established principles of gradient elution. A good correlation between the observed and calculated retention times for several test proteins was obtained at various total gradient times and column flow-rates. Conversely, isocratic retention parameters characterizing protein retention can be calculated from gradient elution retention data. However, even with retention data of high quality, small errors are amplified by the log-log nature of the ion-exchange isocratic retention model employed. Based on the close correlation between predicted and observed gradient retention times, no evidence for protein denaturation resulting from immobilization of the protein at high initial k' values at or near the column inlet was observed.  相似文献   

2.
The liquid chromatographic separation of 19 monoaromatic chlorophenols on a beta-cyclodextrin bonded-phase column is investigated in both an isocratic and a gradient elution mode. Even though the isocratic mode can be employed for the separation of the member components of each category of chlorophenols (e.g., mono-, di-, etc.), significant overlaps between the retention times of the various categories prevent the separation of all chlorophenols on a single chromatogram. Gradient elution can be used, however, for the separation of 15 of the 19 chlorophenol isomers. The unique features of gradient elution as applied to beta-cyclodextrin bonded-phase columns are discussed. The detection of chlorophenols with UV and electrochemical methods is also discussed and the two are compared.  相似文献   

3.
In this paper we describe how the existing theories to describe retention and peak width in isocratic and gradient-elution liquid chromatography can be expanded to describe the retention behaviour of natural and synthetic repetitive polymers, which feature distributions of molecules with different masses (and often different structures) rather than unambiguous molecular formulas. For polydisperse samples, it is vital that the model accommodates (isocratic) elution of sample components before the onset of a gradient, elution during the gradient, and elution after the completion of the gradient. The expanded models can readily be implemented in standard spreadsheet software, such as Excel. We have created such spreadsheets based on the conventional model for retention in reversed-phase liquid chromatography (RPLC) and on two different models for retention in normal-phase liquid chromatography. The implementation allows an easy visualization of the theoretical concept. Up to three different polymeric series can be entered, with a total of up to 100 peaks being computed and displayed in isocratic or gradient-elution chromatograms. Also visualized are "retention models" (diagrams of isocratic retention vs. composition) and "calibration curves" (retention or elution composition vs. molecular mass or degree of polymerization). The coefficients in the isocratic retention model may be correlated, as has often been observed in RPLC. It is shown that under certain conditions such a correlation corresponds to the existence of so-called critical (isocratic) conditions, at which all the members of a given polymeric series (same composition and end groups, different number of repeat units) show co-elution.  相似文献   

4.
The combined effect of temperature, T, and organic modifier concentration, phi, on the retention under gradient conditions in RPLC is studied by considering, both theoretically and experimentally gradients, of phi at constant T and gradients of T at constant phi. Two approaches are examined: in the first approach the prediction of the elution time of a sample solute is based on the isocratic/isothermal properties of this solute. The second approach is based on a direct fitting procedure of a proper retention model to 2-D isocratic/T-gradient or isothermal/phi-gradient retention data. These approaches were tested using alkylbenzes in eluting systems modified by ACN. We found that both approaches can give excellent predictions under certain prerequisites. However, the first approach exhibits the notable advantage that it can be used effectively to predict retention times under any kind of phi-gradients at constant T or T-gradients at constant phi. The second approach has the advantage that it is relatively simple but its applicability is very restricted since its predictions are satisfactory only if the gradients are of the same kind with those used in the fitting procedure and the conditions lie within those used for fitting.  相似文献   

5.
This paper describes the results of the evaluation of retention dependence on the physicochemical properties of solutes in linear gradient elution by reversed-phase liquid chromatography (RPLC) based on linear solvation energy relationships (LSERs). Retention time data on Inertsil ODS(3) column by linear gradient elution were collected for both acetonitrile-water and methanol-water binary mobile phases under various gradient steepness. Based on the LSERs, the retention times were linearly correlated with the physicochemical properties (size, dipolarity, and hydrogen bond donor-acceptor acidity and basicity) of solutes. As predicted by LSERs, very acceptable linear relationships are observed for both mobile phases. While the magnitudes of the coefficients are modified by the gradient steepness, their signs are consistent with those obtained by isocratic elution. As obtained for isocratic elution, the dominant factors to retention in linear gradient elution of RPLC are the solutes' size and hydrogen bond acceptor basicity. The conclusions of the study allow us to predict retention in chromatographic method development by gradient elution.  相似文献   

6.
A new mathematical treatment concerning the gradient elution in reversed-phase liquid chromatography when the volume fraction psi of an organic modifier in the water-organic mobile phase varies linearly with time is presented. The experimental ln k versus psi curve, where k is the retention factor under isocratic conditions in a binary mobile phase, is subdivided into a finite number of linear portions and the solute gradient retention time tR is calculated by means of an analytical expression arising from the fundamental equation of gradient elution. The validity of the proposed analytical expression and the methodology followed for the calculation of tR was tested using eight catechol-related solutes with mobile phases modified by methanol or acetonitrile. It was found that in all cases the accuracy of the predicted gradient retention times is very satisfactory because it is the same with the accuracy of the retention times predicted under isocratic conditions. Finally, the above method for estimating gradient retention times was used in an optimisation algorithm, which determines the best variation pattern of psi that leads to the optimum separation of a mixture of solutes at different values of the total elution time.  相似文献   

7.
8.
Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.  相似文献   

9.
When facing separation problems in ion chromatography, chromatographers often lack guidelines to decide a priori if isocratic elution will give enough separation in a reasonable analysis time or a gradient elution will be required. This situation may be solved by the prediction of retention in gradient elution mode by using isocratic experimental data. This work describes the development of an ion chromatographic gradient elution retention model for fluoride, chloride, nitrite, bromide, nitrate, sulfate and phosphate by using isocratic experimental data. The isocratic elution retention model was developed by applying a polynomial relation between the logarithm of the retention factor and logarithm of the concentration of competing ions; the gradient elution retention model was based on the stepwise numerical integration of the corresponding differential equation. It was shown that the developed gradient elution retention model was not significantly affected by transferring data form isocratic experiment. The root mean squared prediction error for gradient elution retention model was between 0.0863 for fluoride and 0.7027 for bromide proving a very good predictive ability of developed gradient elution retention model.  相似文献   

10.
The transferability of retention data among isocratic and gradient RPLC elution modes is studied. For this purpose, 16 beta-blockers were chromatographed under both isocratic and gradient elution with acetonitrile-water mobile phases. Taking into account the elution mode where the experimental data come from, and the mode where the retention should be predicted, the following combinations are possible: isocratic predictions from (i) isocratic or (ii) gradient experimental designs; and gradient predictions from (iii) isocratic or (iv) gradient data. Each of these possibilities was checked using three retention models that relate the logarithm of the retention factor: (a) linearly and (b) quadratically with the volume fraction of organic solvent, and (c) linearly with a normalised mobile phase polarity parameter. The study was carried out under two different perspectives: a straightforward examination of the prediction errors and the analysis of the uncertainties derived from the variance-covariance matrix of the fitted models. The best combinations of prediction mode and model were: (i)-(b), (ii)-(c), (iii)-(b), and (iv)-(a) or (c).  相似文献   

11.
The fundamental equations and conditions for linear and stepwise gradient elution in reversed-phase liquid chromatography are applied to a mixture of amino acids in their underivatized form in aqueous mobile phases modified by 2-propanol, acetonitrile or methanol for examining column equilibration effects. It was found in all cases systematic deviations between experimental and calculated retention times, which are prominent in 2-propanol, reduced in acetonitrile and practically negligible in methanol. These deviations appear within a chromatogram just after the first change in the composition of the mobile phase reaches the detector and last ca. 5 min, where the magnitude of errors reduces exponentially with time. Based on these observations we propose a simple way to correct the calculated from the gradient elution theory retention times of sample solutes. The origin of the discrepancies between theory and experiment as well as their impact on the resolution is also discussed.  相似文献   

12.
The suitability of three different retention models to predict the retention times of poly(ethylene glycol)s (PEGs) in gradient and isocratic chromatography was investigated. The models investigated were the linear (LSSM) and the quadratic solvent strength model (QSSM). In addition, a model describing the retention behaviour of polymers was extended to account for gradient elution (PM). It was found that all models are suited to properly predict gradient retention volumes provided the extraction of the analyte specific parameters is performed from gradient experiments as well. The LSSM and QSSM on principle cannot describe retention behaviour under critical or SEC conditions. Since the PM is designed to cover all three modes of polymer chromatography, it is therefore superior to the other models. However, the determination of the analyte specific parameters, which are needed to calibrate the retention behaviour, strongly depend on the suitable selection of initial experiments. A useful strategy for a purposeful selection of these calibration experiments is proposed.  相似文献   

13.
The experimental technique of mass spectrometric tracer pulse chromatography was used to study the effect of the sorption of eluent components by a C18-bonded silica RPLC packing on the retention of a series of test analytes during isocratic and gradient elution experiments. The analytes of interest were a substituted phenol, a substituted nitroaniline, an anti-malaria drug, tetrahydrofuran, and methanol. The eluent used was a mixture of acetonitrile and water. The solutes and isotopically labeled eluent components were injected at fixed time intervals during each gradient run. The mass specific detector allowed the assignment of individual analyte peaks even when there was overlap in the chromatograms from successive injections. Thus, the retention time of each analyte could be determined as a function of gradient slope and initial eluent composition at the time of each injection. Experimental gradient retention time data were then compared with the calculated results from two theoretical models. The first model assumed the velocity of the mobile phase and eluent were equal. The second and most realistic model assumed the velocity of the eluent was less than the velocity of the mobile phase due to the uptake of eluent by the stationary phase. Gradient retention times predicted by the two models were reasonably accurate with the sorption model giving slightly more accurate values. Inverse calculations, i.e., calculation of isocratic retention factors from gradient elution data were also carried out with very similar results. That is, the model allowing for the uptake of eluent was slightly more accurate than the model assuming no eluent-stationary phase interaction.  相似文献   

14.
The first six linear and cyclic oligomers of polyamide-6 can be quantitatively determined in the polymer using HPLC with the sandwich injection method and an aqueous acetonitrile gradient. In this final part of the triptych concerning the determination of the oligomers in polyamide-6, the irregular elution behavior of the cyclic monomer compared to the cyclic oligomers was investigated. We also optimized the separation of the involved polyamide oligomers, with respect to gradient steepness, stationary phase, column temperature and mobile phase pH. The irregular elution behavior of the cyclic monomer could be caused by its relatively large exposed/accessible hydrophobic surface, which permits relatively easy penetration into the hydrophobic stationary phase giving extra retention. The dipole moment of the different oligomers was used as a measure for this exposed/accessible hydrophobic area to correlate the retention factors using quantitative structure-retention relationships. We also studied the retention behavior of the polyamide, which is injected each run directly onto the column and modifies the stationary phase. Using a 250-microl post gradient injection zone of formic acid on a 250x3 mm Zorbax SB-C18 column, the polyamide could be effectively removed from the stationary phase after each separation. The linear solvent strength (LSS) model was used to optimize the separation of the first six linear and cyclic oligomers. As the LSS model assumes a linear correlation between the modifier concentration and the logarithm of the retention factor and the cyclic monomer and dimer show extreme curvation of this relation in the eluting region, we investigated different models to predict gradient elution from isocratic data. A direct translation of the isocratic data to gradient retention times did not yield adequate retention times using the LSS model. It was found that the LSS model worked acceptably if gradient retention times were used as input data. Even for fast non-linearly eluting components, an average error of 0.4 resolution units of 4sigma was obtained. Using the LSS model in combination with different column temperatures and mobile phase pH values, a separation of the first six linear and cyclic oligomers was accomplished.  相似文献   

15.
The applicability and predictive properties of the linear solvent strength model and two nonlinear retention‐time models, i.e., the quadratic model and the Neue model, were assessed for the separation of small molecules (phenol derivatives), peptides, and intact proteins. Retention‐time measurements were conducted in isocratic mode and gradient mode applying different gradient times and elution‐strength combinations. The quadratic model provided the most accurate retention‐factor predictions for small molecules (average absolute prediction error of 1.5%) and peptides separations (with a prediction error of 2.3%). An advantage of the Neue model is that it can provide accurate predictions based on only three gradient scouting runs, making tedious isocratic retention‐time measurements obsolete. For peptides, the use of gradient scouting runs in combination with the Neue model resulted in better prediction errors (<2.2%) compared to the use of isocratic runs. The applicability of the quadratic model is limited due to a complex combination of error and exponential functions. For protein separations, only a small elution window could be applied, which is due to the strong effect of the content of organic modifier on retention. Hence, the linear retention‐time behavior of intact proteins is well described by the linear solvent strength model. Prediction errors using gradient scouting runs were significantly lower (2.2%) than when using isocratic scouting runs (3.2%).  相似文献   

16.
郝卫强  刘丽娟  沈巧银 《色谱》2021,39(1):10-14
谱带压缩效应是梯度洗脱区别于等度洗脱的重要特征。经典的范德姆特(van Deemter)理论塔板高度方程基于等度洗脱推导得到,因此不能对谱带压缩效应进行描述。在梯度洗脱中,保留因子(k)会随流动相组成(φ)的改变而发生变化,这就使得对梯度洗脱机理的研究要比等度洗脱复杂许多。该文对近10年来谱带压缩效应的研究进展,特别是溶剂强度模型(即描述ln kφ关系的数学表达式)的非线性特征对谱带压缩因子(G)的影响进行了述评,指出为了更好地认识谱带压缩效应需要将这种非线性因素考虑在内。  相似文献   

17.
Advances in the theory of gradient liquid chromatography and their practical impacts are reviewed. Theoretical models describing retention in reversed-phase, normal-phase and ion-exchange modes are compared. Main attention is focused on practically useful models described by two- or three-parameter equations fitting the experimental data in the range of mobile phase composition utilized for sample migration during gradient elution. The applications of theory for gradient method development, optimization and transfer are addressed. The origins and possibilities for overcoming possible pitfalls are discussed, including the effects of the instrumental dwell volume, uptake of mobile phase components on the column and size of the sample molecules. Special attention is focused on gradient separations of large molecules.  相似文献   

18.
Abstract

An HPLC procedure using flow programming under isocratic elution conditions for determination of drugs and their metabolites in biological fluids is discussed. This technique was used in the analysis of triamterene and its metabolites in urine, chlorothiazide in plasma and hydrochlorothiazide in urine. Advantages of flow programming over conventional procedures such as isocratic elution and gradient elution are discussed.  相似文献   

19.
Dias NC  Nawas MI  Poole CF 《The Analyst》2003,128(5):427-433
The solvation parameter model is used to identify suitable chromatographic models for estimating the octanol-water partition coefficient for neutral compounds of varied structure by reversed-phase liquid chromatography. The stationary phase Supelcosil LC-ABZ with methanol-water mobile phases affords a series of suitable correlation models for estimating the octanol-water partition coefficient (log KOW) under isocratic and gradient elution conditions. Isocratic separations with mobile phase compositions containing from about 25 to 40% (v/v) methanol provide the most accurate results for log KOW values in the range -0.1 to 4.0. Gradient separations programmed from 5 to 100% (v/v) methanol are suitable for faster separations of compounds with large log KOW values. The standard error in the estimate for the regression models of the predicted log KOW values against literature values are 0.135 log units for the 30% (v/v) methanol-water isocratic system and 0.263 log units for the methanol-water gradient system. Isocratic retention factors predicted from two gradient separations with gradient times of 15 and 45 min afford a poorer fit for the correlation models between log KOW and the estimated retention factors than that of either the above isocratic and gradient models. Plots of the retention factor (log k) as a function of mobile phase composition are generally non-linear. Values of log kw obtained by non-linear extrapolation to a volume fraction of 0% (v/v) methanol do not afford a useful model for estimating log KOW.  相似文献   

20.
在采用反相液相色谱或亲和色谱完成蛋白质等大分子分离时,根据溶质保留值随溶剂梯度变化曲线上突变点的差别,可以通过累加进样分离法进行样品制备或直接柱内富集分析,但这一方法并非在任意条件下、对任何样品都适用。该文根据不同形式的保留值方程从理论上探讨了样品保留值与进样时间差、梯度洗脱速率等实验条件之间的关系;结果表明:两次进样的出峰时间差与进样时间间隔成正比关系,也与其在等度情况下的容量因子有关。样品中的两种组分在间隔进样时的流出时间差主要由两组分的容量因子决定,当样品中存在两种以上保留性能相近组分时,若保证指定的分离度,进样时间间隔存在一极大值,超出该范围,分离条件将不能满足  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏