首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report the development of a robust and effective method for multiplexed short tandem repeat (STR) analysis within a chip-based microdevice. The method uses a laser-induced fluorescence detection system and simultaneously detects three- and four-color multiplexed polymerase chain reaction (PCR) samples. Analyses of the eight combined DNA index system (CODIS) STR loci were performed in 20 min with single-base-pair resolution ranging from 0.75 to 1. A simultaneous analysis of fifteen loci-ladders and a gender marker Amelogenin based on the PowerPlexTM 16 System was achieved in less than 35 min. The system is capable of repetitive operation and may be extended to high-throughput multilane devices that could be readily interfaced to an automated sample loading system.  相似文献   

2.
Microfluidic technology has been utilized in the development of a modular system for DNA identification through STR (short tandem repeat) analysis, reducing the total analysis time from the ∼6 h required with conventional approaches to less than 3 h. Results demonstrate the utilization of microfluidic devices for the purification, amplification, separation and detection of 9 loci associated with a commercially-available miniSTR amplification kit commonly used in the forensic community. First, DNA from buccal swabs purified in a microdevice was proven amplifiable for the 9 miniSTR loci via infrared (IR)-mediated PCR (polymerase chain reaction) on a microdevice. Microchip electrophoresis (ME) was then demonstrated as an effective method for the separation and detection of the chip-purified and chip-amplified DNA with results equivalent to those obtained using conventional separation methods on an ABI 310 Genetic Analyzer. The 3-chip system presented here demonstrates development of a modular, microfluidic system for STR analysis, allowing for user-discretion as to how to proceed after each process during the analysis of forensic casework samples.  相似文献   

3.
This work describes the development of a novel microdevice for forensic DNA processing of reference swabs. This microdevice incorporates an enzyme‐based assay for DNA preparation, which allows for faster processing times and reduced sample handling. Infrared‐mediated PCR (IR‐PCR) is used for STR amplification using a custom reaction mixture, allowing for amplification of STR loci in 45 min while circumventing the limitations of traditional block thermocyclers. Uniquely positioned valves coupled with a simple rotational platform are used to exert fluidic control, eliminating the need for bulky external equipment. All microdevices were fabricated using laser ablation and thermal bonding of PMMA layers. Using this microdevice, the enzyme‐mediated DNA liberation module produced DNA yields similar to or higher than those produced using the traditional (tube‐based) protocol. Initial microdevice IR‐PCR experiments to test the amplification module and reaction (using Phusion Flash/SpeedSTAR) generated near‐full profiles that suffered from interlocus peak imbalance and poor adenylation (significant ?A). However, subsequent attempts using KAPA 2G and Pfu Ultra polymerases generated full STR profiles with improved interlocus balance and the expected adenylated product. A fully integrated run designed to test microfluidic control successfully generated CE‐ready STR amplicons in less than 2 h (<1 h of hands‐on time). Using this approach, high‐quality STR profiles were developed that were consistent with those produced using conventional DNA purification and STR amplification methods. This method is a smaller, more elegant solution than current microdevice methods and offers a cheaper, hands‐free, closed‐system alternative to traditional forensic methods.  相似文献   

4.
Lab‐on‐a‐chip provides an ideal platform for short tandem repeat (STR) genotyping due to its intrinsic low sample consumption, rapid analysis, and high‐throughput capability. One of the challenges, however, in the forensic human identification on the microdevice is the detection sensitivity derived from the nanoliter volume sample handling. To overcome such a sensitivity issue, here we developed a sample stacking CE microdevice for mini Y STR genotyping. The mini Y STR includes redesigned primer sequences to generate smaller‐sized PCR amplicons to enhance the PCR efficiency and the success rate for a low copy number and degraded DNA. The mini Y STR amplicons occupied in the 5‐ and 10‐mm stacking microchannels are preconcentrated efficiently in a defined narrow region through the optimized sample stacking CE scheme, resulting in more than tenfold improved fluorescence peak intensities compared with that of a conventional cross‐injection microcapillary electrophoresis method. Such signal enhancement allows us to successfully analyze the Y STR typing with only 25 pg of male genomic DNA, with high background of female genomic DNA, and with highly degraded male genomic DNA. The combination of the mini Y STR system with the novel sample stacking CE microdevice provides the highly sensitive Y STR typing on a chip, making it promising to perform high‐performance on‐site forensic human identification.  相似文献   

5.
We report preliminary testing of "GeneTrack", an instrument designed for the specific application of multiplexed short tandem repeat (STR) DNA analysis. The system supports a glass microdevice with 16 lanes of 20 cm effective length and double-T cross injectors. A high-speed galvanometer-scanned four-color detector was specially designed to accommodate the high elution rates on the microdevice. All aspects of the system were carefully matched to practical crime lab requirements for rapid reproducible analysis of crime-scene DNA evidence in conjunction with the United States DNA database (CODIS). Statistically significant studies demonstrate that an absolute, three-sigma, peak accuracy of 0.4-0.9 base pair (bp) can be achieved for the CODIS 13-locus multiplex, utilizing a single channel per sample. Only 0.5 microL of PCR product is needed per lane, a significant reduction in the consumption of costly chemicals in comparison to commercial capillary machines. The instrument is also designed to address problems in temperature-dependent decalibration and environmental sensitivity, which are weaknesses of the commercial capillary machines for the forensics application.  相似文献   

6.
A fully integrated microdevice and process for forensic short tandem repeat (STR) analysis has been developed that includes sequence-specific DNA template purification, polymerase chain reaction (PCR), post-PCR cleanup and inline injection, and capillary electrophoresis (CE). Fragmented genomic DNA is hybridized with biotin-labeled capture oligos and pumped through a fluidized bed of magnetically immobilized streptavidin-coated beads in microchannels where the target DNA is bound to the beads. The bead-DNA conjugates are then transferred into a 250 nL PCR reactor for autosomal STR amplification using one biotin and one fluorescence-labeled primer. The resulting biotin-labeled PCR products are electrophoretically injected through a streptavidin-modified capture gel where they are captured to form a concentrated and purified injection plug. The thermally released sample plug is injected into a 14 cm long CE column for fragment separation and detection. The DNA template capture efficiency provided by the on-chip sequence-specific template purification is determined to be 5.4% using K562 standard DNA. This system can produce full 9-plex STR profiles from 2.5 ng input standard DNA and obtain STR profiles from oral swabs in about 3 hours. This fully integrated microsystem with sample-in-answer-out capability is a significant advance in the development of rapid, sensitive, and reliable micro-total analysis systems for on-site human identification.  相似文献   

7.
Short tandem repeats (STRs), known as microsatellites, are one of the most informative genetic markers for characterizing biological materials. Because of the relatively small size of STR alleles (generally 100-350 nucleotides), amplification by polymerase chain reaction (PCR) is relatively easy, affording a high sensitivity of detection. In addition, STR loci can be amplified simultaneously in a multiplex PCR. Thus, substantial information can be obtained in a single analysis with the benefits of using less template DNA, reducing labor, and reducing the contamination. We investigated 14 STR loci in a Japanese population living in Sendai by three multiplex PCR kits, GenePrint PowerPlex 1.1 and 2.2. Fluorescent STR System (Promega, Madison, WI, USA) and AmpF/STR Profiler (Perkin-Elmer, Norwalk, CT, USA). Genomic DNA was extracted using sodium dodecyl sulfate (SDS) proteinase K or Chelex 100 treatment followed by the phenol/chloroform extraction. PCR was performed according to the manufacturer's protocols. Electrophoresis was carried out on an ABI 377 sequencer and the alleles were determined by GeneScan 2.0.2 software (Perkin-Elmer). In 14 STRs loci, statistical parameters indicated a relatively high rate, and no significant deviation from Hardy-Weinberg equilibrium was detected. We apply this STR system to paternity testing and forensic casework, e.g., personal identification in rape cases. This system is an effective tool in the forensic sciences to obtain information on individual identification.  相似文献   

8.
Lee TM  Carles MC  Hsing IM 《Lab on a chip》2003,3(2):100-105
Microfabricated silicon/glass-based devices with functionalities of simultaneous polymerase chain reaction (PCR) target amplification and sequence-specific electrochemical (EC) detection have been successfully developed. The microchip-based device has a reaction chamber (volume of 8 microl) formed in a silicon substrate sealed by bonding to a glass substrate. Electrode materials such as gold and indium tin oxide (ITO) were patterned on the glass substrate and served as EC detection platforms where DNA probes were immobilized. Platinum temperature sensors and heaters were patterned on top of the silicon substrate for real-time, precise and rapid thermal cycling of the reaction chamber as well as for efficient target amplification by PCR. DNA analyses in the integrated PCR-EC microchip start with the asymmetric PCR amplification to produce single-stranded target amplicons, followed by immediate sequence-specific recognition of the PCR product as they hybridize to the probe-modified electrode. Two electrochemistry-based detection techniques including metal complex intercalators and nanogold particles are employed in the microdevice to achieve a sensitive detection of target DNA analytes. With the integrated PCR-EC microdevice, the detection of trace amounts of target DNA (as few as several hundred copies) is demonstrated. The ability to perform DNA amplification and EC sequence-specific product detection simultaneously in a single reaction chamber is a great leap towards the realization of a truly portable and integrated DNA analysis system.  相似文献   

9.
The polymerase chain reaction (PCR) is critical for amplification of target sequences of DNA or RNA that have clinical, biological or forensic relevance. While extrinsic Fabry-Perot interferometry (EFPI) has been shown to be adequate for non-contact temperature sensing, the difficulty in defining a reflective surface that is semi-reflective, non-reactive for PCR compatibility and adherent for thermal bonding has limited its exploitation. Through the incorporation of a reflective surface fabricated using a thermally driven self-assembly of a platinum nanoparticle monolayer on the surface of the microfluidic chamber, an enhanced EFPI signal results, allowing for non-contact microfluidic temperature control instrumentation that uses infrared-mediated heating, convective forced-air cooling, and interferometic temperature sensing. The interferometer is originally calibrated with a miniature copper-constantan thermocouple in the PCR chamber resulting in temperature sensitivities of -22.0 to -32.8 nm·°C(-1), depending on the chamber depth. This universal calibration enables accurate temperature control in any device with arbitrary dimensions, thereby allowing versatility in various applications. Uniquely, this non-contact temperature control for PCR thermocycling is applied to the amplification of STR loci for human genetic profiling, where nine STR loci are successfully amplified for human identification using the EFPI-based non-contact thermocycling.  相似文献   

10.
The Microreader? 20A ID system is designed for forensic applications such as personal identification, parentage testing, and research. It includes 13 combined DNA index system (CODIS) short tandem repeat (STR) loci (CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11), three expanded CODIS STR loci (D12S391, D19S433, and D2S1338), three non‐CODIS STR loci (D6S1043, Penta D, and Penta E), and the amelogenin locus in one reaction with a six‐dye fluorescent (FAM, HEX, TAMAR, ROX, PUR, and QD550) analysis system. In this study, the Microreader? 20A ID system was validated according to the Scientific Working Group on DNA Analysis Methods validation guidelines for forensic DNA Analysis methods and Chinese national standard, including PCR‐based studies, sensitivity study, precision, and accuracy evaluation, stutter calculation, inhibitor tests, species specificity, and DNA mixture studies. Our results suggest that the Microreader? 20A ID system is a useful tool for personal identification and parentage testing.  相似文献   

11.
12.
Wu W  Loan KT  Lee NY 《The Analyst》2012,137(9):2069-2076
Consistent temperature control in an on-chip flow-through polymerase chain reaction (PCR) employing two or more heaters is one of the main obstacles for device miniaturization and integration when realizing micro total analysis systems (μTAS), and also leads to operational complexity. In this study, we propose a qiandu (right triangular prism)-shaped polydimethylsiloxane (PDMS) microdevice with serpentine microchannels fabricated on its slanted plane, and apply the device for an on-chip flow-through PCR employing a single heater. The inclined nature of the qiandu-shaped microdevice enables the formation of a surface temperature gradient along the slanted plane of the microdevice in a height-dependent manner by the use of a single heater, and enables liquid to traverse over wide ranges of temperatures, including the three temperature zones--denaturation, annealing, and extension temperatures--required in a typical PCR. The feasibility of the qiandu-shaped PDMS microdevice as a versatile platform for performing a flow-through PCR was examined by employing multiple templates and varying the inclination angle of the device. In addition, the potential of performing a multiplex PCR using a single qiandu-shaped PDMS microdevice was explored. A 409 bp long gene fragment effective as a marker for diagnosing lung cancer and a 230 bp long gene fragment from a plasmid vector were simultaneously amplified in less than 25 min on a single microdevice, paving the way for a microscale, multiplex PCR on a single device employing a single heater.  相似文献   

13.
Chen Y  Seo TS 《Electrophoresis》2011,32(12):1456-1464
We demonstrated a proof‐of‐concept for novel minisatellite tandem repeat typing, called PCR‐free digital VNTR (variable number tandem repeat) typing, which is composed of three steps: a ligation reaction instead of PCR thermal cycling, magnetic bead‐based solid‐phase capture for purification, and an elongated sample stacking microcapillary electrophoresis (μCE) for sensitive digital coding of repeat number. We designed a 16‐bp fluorescently labeled ligation probe which is complementary to a repeat unit of a biotinylated synthetic template mimicking the human D1S80 VNTR locus and is randomly hybridized with the minisatellite tandem repeats. A quick isothermal ligation reaction was followed to link the adjacent ligation probes on the DNA templates, and then the ligated products were purified by streptavidin‐coated magnetic beads. After a denaturing step, a large amount of ligated products whose size difference was equivalent to the repeat unit were released and recovered. Through the elongated sample stacking μCE separation on a microdevice, the fluorescence signal of the ligated products was generated in the electropherogram and the peak number was directly counted which was exactly matched with the repeat number of VNTR locus. We could successfully identify the minisatellite tandem repeat number with only 5 fmol of DNA template in 30 min.  相似文献   

14.
基于固相萃取原理和微电子机械系统(Micro-Electro-Mechanical System, MEMS)技术研制了一种多孔氧化硅微流控样品预处理芯片, 并利用具有大比表面积的多孔氧化硅作为提取DNA的固相载体, 从而大大提高了DNA的提取产率. 分析了影响DNA提取产率的因素, 改进了芯片制备工艺和DNA提取实验方案, 成功地提取了小鼠外周血DNA, 提取产率为24 ng/(μL全血), 达到商用试剂盒水平. 同时以该DNA作为PCR扩增模板, 扩增效果良好.  相似文献   

15.
This study developed a new multiplex PCR system that simultaneously amplifies 16 X‐STR loci in the same PCR reaction, and the polymorphism and mutation rates of these 16 X‐STR loci were explored in a Shanghai Han population from China. These loci included DXS10134, DXS10159, DXS6789, DXS6795, DXS6800, DXS6803, DXS6807, DXS6810, DXS7132, DXS7424, DXS8378, DXS9902, GATA165B12, GATA172D05, GATA31E08, and HPRTB. Samples from 591 unrelated individuals (293 males and 298 females) and 400 two‐generation families were successfully analyzed using this multiplex system. Allele frequencies and mutation rates of the 16 loci were investigated, with the comparison of allele frequency distributions among different populations performed. Polymorphism information contents of these loci were all >0.6440 except the locus DXS6800 (0.4706). Nine cases of mutations were detected in the 16 loci from the investigation of 9232 meioses. Pairwise comparisons of allele frequency distributions showed significant differences for most loci among populations from different countries and ethnic groups but not among the Han population living in other areas of China. These results suggest that the 16 X‐STR loci system provides highly informative polymorphic data for paternity testing and forensic identification in the Han population in Shanghai, China, as a complementary tool.  相似文献   

16.
This work describes a microfluidic device integrated with multichamber polymerase chain reaction (PCR) and multichannel separation for parallel genetic analysis. The microdevice consists of three functional units: temperature control, multiple PCR (four chambers PCR), and multiple channel separation (four separation channels, each channel connected to a PCR chamber). Platinum (Pt)/titanium (Ti) microheater was used to ensure homogeneous temperature field, and Pt-chip sensor was used for temperature monitoring. The interface between chip-PCR and chip separation was simplified by connecting the PCR chamber with separation channel directly. After chip-PCR, PCR products were introduced into parallel separation channels for subsequent separation/detection by applying an electric field automatically. This microdevice was successfully applied for detection of pathogens including hepatitis B virus (HBV) and Mycobacterium tuberculosis (MTB), and genotyping of human leucocyte antigen (HLA)-B27 as well, demonstrating the feasibility of the integrated microdevice for parallel genetic analysis.  相似文献   

17.
Whole-genome DNA amplification (WGA) is a promising method that generates large amounts of DNA from samples of limited quantity. We investigated the accuracy of a multiplex PCR approach to WGA over STR loci. The amplification bias within a locus and over all analyzed loci was investigated in relation to the amount of template in the WGA reaction, the specific STR locus, and allele length. We observed reproducible error-free STR profiles with 10 ng down to 1 ng of DNA template. The amplification deviation at a locus and between loci was within the intra-method reproducibility. WGA is the method of choice for amplifying nanogram amounts of genomic DNA for different applications. We detected unbalanced STR amplifications at one locus and between loci, allelic drop-outs, and additional alleles after WGA of low-copy-number DNA. We found that the high number of drop-outs and drop-ins could be eradicated using pooled DNA from separate WGA reactions even with as little as 100 pg of starting template. Nevertheless, the quality of the results was still not sufficient for use in routine chimerism analysis of limited specific cell populations after allogeneic stem cell transplantation.  相似文献   

18.
Poly(dimethylsiloxane) (PDMS) membrane valves were utilized for diaphragm pumping on a PDMS-glass hybrid microdevice in order to couple infrared-mediated DNA amplification with electrophoretic separation of the products in a single device. Specific amplification products created during non-contact, infrared (IR) mediated polymerase chain reaction (PCR) were injected via chip-based diaphragm pumping into an electrophoretic separation channel. Channel dimensions were designed for injection plug shaping via preferential flow paths, which aided in minimizing the plug widths. Unbiased injection of sample could be achieved in as little as 190 ms, decreasing the time required with electrokinetic injection by two orders of magnitude. Additionally, sample stacking was promoted using laminar or biased-laminar loading to co-inject either water or low ionic strength DNA marker solution along with the PCR-amplified sample. Complete baseline resolution (Res = 2.11) of the 80- and 102-bp fragments of pUC-18 DNA marker solution was achieved, with partially resolved 257- and 267-bp fragments (Res = 0.56), in a separation channel having an effective length of only 3.0 cm. This resolution was deemed adequate for many PCR amplicon separations, with the added advantage of short separation time-typically complete in <120 s. Decreasing the amount of glass surrounding the PCR chamber reduced the DNA amplification time, yielding a further enhancement in analysis speed, with heating and cooling rates as high as 13.4 and -6.4 degrees C s(-1), respectively. With the time requirements greatly reduced for each step, it was possible to seamlessly couple IR-mediated amplification, sample injection, and separation/detection of a 278-bp fragment from the invA gene of <1000 starting copies of Salmonella typhimurium DNA in approximately 12 min on a single device, representing the fastest PCR-ME integration achieved to date.  相似文献   

19.
20.
DNA profiling of short tandem repeats (STR) has been successfully used for the identification of individuals in forensic samples, accidents and natural disasters. However, STR profiling of DNA isolated from old crime scenes and damaged biological samples is difficult due to DNA degradation and fragmentation. Here, we show that pre‐amplification of STR loci using biotinylated primers for the STR loci is an efficient strategy to obtain STR profiling results from fragmented forensic samples. Analysis of STR loci with longer amplicon sizes is generally hampered, since these relatively long loci are vulnerable to DNA fragmentation. This problem was overcome by using reduced or increased primer concentrations for loci with shorter or longer amplicon sizes, respectively, in our pre‐amplification strategy. In addition, pre‐amplification of STR loci into two groups of short or long amplicon size increases the efficiency of STR profiling from highly fragmented forensic DNA samples. Therefore, differential pre‐amplification of STR loci is an effective way to obtain DNA profiling results from fragmented forensic samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号