首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel flow injection chemiluminescence method with a myoglobin-luminol system is described for determining aniracetam. Myoglobin-bound aniracetam produced a complex that catalyzed the chemiluminescence reaction between luminol and myoglobin, leading to fast chemiluminescence. The chemiluminescence intensity in the presence of aniracetam was remarkably enhanced compared with that in the absence of aniracetam. Under the optimum reaction conditions the chemiluminescence increment produced was proportional to the concentration of aniracetam in the range of 0.1-1000.0 ng/mL (R2 = 0.9992), with a detection limit of 0.03 ng/mL (3delta). At a flow rate of 2.0 mL/min, the whole process, including sampling and washing, could be completed in 0.5 min, offering a sampling efficiency of 120/h; the RSD was less than 3.0% (n = 5). The method was satisfactory for determination of aniracetam in pharmaceutical preparations and human urine and serum samples. A possible mechanism of the reaction is also discussed.  相似文献   

2.
Hydrogen peroxide (H2O2) present in honey was rapidly determined by the differential amperometric method in association with flow-injection analysis (FIA) and a tubular reactor containing immobilized enzymes. A gold electrode modified by electrochemical deposition of platinum was employed as working electrode. Hydrogen peroxide was quantified in 14 samples of Brazilian commercial honeys using amperometric differential measurements at +0.60V vs. Ag/AgCl((sat)). For the enzymatic consumption of H2O2, a tubular reactor containing immobilized peroxidase was constructed using an immobilization of enzymes on Amberlite IRA-743 resin. The linear dynamic range in H2O2 extends from 1 to 100 x 10(-6) mol L(-1), at pH 7.0. At flow rate of 2.0 mL min(-1) and injecting 150 microL sample volumes, the sampling frequency of the 90 determinations per hour is afforded. This method is based on three steps involving the flow-injection of: (1) the sample spiked with a standard solution, (2) the pure sample and (3) the enzymatically treated sample with peroxidase immobilized. The reproducibility of the current peaks for hydrogen peroxide in 10(-5) mol L(-1) range concentration showed a relative standard deviation (R.S.D.) better than 1%. The detection limit of this method is 2.9 x 10(-7) mol L(-1). The honey samples analyses were compared with the parallel spectrophotometric determination, and showed an excellent correlation between the methods.  相似文献   

3.
A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min−1, respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to generate concentration profiles for all the components in the reaction. Also, it was possible to detect the presence of a simulated impurity of ethanol (at levels of 2.6 and 9.1% mol/mol) in butan-1-ol, and the resulting production of ethyl acetate, by DLSMS, but not by in-line MIR spectrometry.  相似文献   

4.
Electroosmotic pumps are arguably the simplest of all pumps, consisting merely of two flow-through electrodes separated by a porous membrane. Most use platinum electrodes and operate at high voltages, electrolyzing water. Because evolved gas bubbles adhere and block parts of the electrodes and the membrane, steady pumping rates are difficult to sustain. Here we show that when the platinum electrodes are replaced by consumed Ag/Ag(2)O electrodes, the pumps operate well below 1.23 V, the thermodynamic threshold for electrolysis of water at 25 °C, where neither H(2) nor O(2) is produced. The pumping of water is efficient: 13?000 water molecules are pumped per reacted electron and 4.8 mL of water are pumped per joule at a flow rate of 0.13 mL min(-1) V(-1) cm(-2), and a flow rate per unit of power is 290 mL min(-1) W(-1). The water is driven by protons produced in the anode reaction 2Ag(s) + H(2)O → Ag(2)O(s) + 2H(+) + 2e(-), traveling through the porous membrane, consumed by hydroxide ions generated in the cathode reaction Ag(2)O(s) + 2 H(2)O + 2e(-) → 2Ag(s) + 2 OH(-). A pump of 2 mm thickness and 0.3 cm(2) cross-sectional area produces flow of 5-30 μL min(-1) when operating at 0.2-0.8 V and 0.04-0.2 mA. Its flow rate can be either voltage or current controlled. The flow rate suffices for the delivery of drugs, such as a meal-associated boli of insulin.  相似文献   

5.
An on-line flow injection preconcentration-ETAAS method is developed for trace determination of cobalt in biological materials and natural samples by ion-pair sorption on the inner walls of a PTFE knotted reactor. The ion-pair is formed between the negatively charged cobalt-nitroso-R-salt complex and the tetrabutylammonium counter-ion. An enhancement factor of 15, a sampling frequency of 17 and a concentration efficiency of 4 are obtained for a preconcentration time of 60 s and a sample loading flow rate of 5 mL min(-1). The detection limit (3sigma) is 5 ng L(-1). The relative standard deviation at the 0.2 microg L(-1) level is 2.3%. The analytical results obtained for standard reference materials are in good agreement with the certified or indicated values and satisfactory recoveries of spiked cobalt in tap water are obtained.  相似文献   

6.
In this paper, the luminescence behavior of bovine serum albumin (BSA) and luminol was first studied by flow injection chemiluminescence (CL). It was found that the hyperchromic effect of luminol in the presence of BSA led to the acceleration of the electrons transferring rate of excited 3-aminophthalate, which greatly enhanced the CL intensity of luminol/dissolved oxygen reaction. The increments of CL intensity were proportional to the concentrations of BSA with a linear range from 0.01 to 7 nmol L(-1). It was also found that azithromycin could inhibit the CL intensity of luminol/BSA reaction. The decrements of CL intensity were logarithm over the concentrations of azithromycin ranging from 0.1 to 700 ng mL(-1). At a flow rate of 2.0 mL min(-1), a complete analytical process, which included sampling and washing, could be performed within 30s with relative standard deviations of less than 3.1%. This proposed method was successfully applied in assaying azithromycin in pharmaceutical and human serum samples with recoveries from 91.0 to 104.3%. The possible luminescence mechanism of luminol/BSA/azithromycin reaction was discussed in detail by CL, UV and fluorescence methods.  相似文献   

7.
Real‐time nuclear magnetic resonance (NMR) spectroscopy measurements carried out with a bench‐top system installed next to the reactor inside the fume hood of the chemistry laboratory are presented. To test the system for on‐line monitoring, a transfer hydrogenation reaction was studied by continuously pumping the reaction mixture from the reactor to the magnet and back in a closed loop. In addition to improving the time resolution provided by standard sampling methods, the use of such a flow setup eliminates the need for sample preparation. Owing to the progress in terms of field homogeneity and sensitivity now available with compact NMR spectrometers, small molecules dissolved at concentrations on the order of 1 mmol L?1 can be characterized in single‐scan measurements with 1 Hz resolution. Owing to the reduced field strength of compact low‐field systems compared to that of conventional high‐field magnets, the overlap in the spectrum of different NMR signals is a typical situation. The data processing required to obtain concentrations in the presence of signal overlap are discussed in detail, methods such as plain integration and line‐fitting approaches are compared, and the accuracy of each method is determined. The kinetic rates measured for different catalytic concentrations show good agreement with those obtained with gas chromatography as a reference analytical method. Finally, as the measurements are performed under continuous flow conditions, the experimental setup and the flow parameters are optimized to maximize time resolution and signal‐to‐noise ratio.  相似文献   

8.
The optimization of a continuous flow system for electrochemical hydride generation coupled to microwave-induced plasma atomic emission spectrometry (MIP-AES) for the determination of Se is presented. A small electrolytic cell with a porous glassy carbon working electrode was used for hydride generation. When using an Ar MIP operated in a TE101 cavity a detection limit of 0.6 ng mL(-1) (3sigma) could be achieved. The calibration curve was linear up to 1 microgram mL(-1). A standard deviation of less than 2% (10 replicate analyses) could be achieved. It was shown that interferences of transition metals are of the same order of magnitude as with a larger electrolysis cell described earlier, and light elements hardly caused any signal depression as tested. It was possible to distinguish between Se(IV) and Se(VI) species and seleno-DL-methionine, because under optimized conditions of an electrolysis current of 10 mA, a microwave power of 210 W, an Ar flow rate of 15 L h(-1) and a sample flow rate of 2.5 mL min(-1) only Se(IV) was transformed to H2Se and transferred into the plasma. Finally, the possibility of an electrochemical pre-enrichment was shown to enable it to further decrease the detection limit.  相似文献   

9.
A push-pull sampling system interfaced on-line to high-performance liquid chromatography (HPLC) was developed for micro-volume real-time monitoring of reaction mixtures. The device consists of concentric tubes wherein sample was continuously withdrawn through the outer tube and reaction quenchant continuously delivered through a recessed inner tube. The device allowed sampling rates of 0.1-6.0 μL/min from a reaction vessel and stopped the reaction by passive mixing with quenchant to preserve the conditions observed in the reaction vessel. A finite element model of the system showed that reaction mixtures could be completely mixed with quenchant within 4.3s at a flow rate of 1.0 μL/min. The model also showed that an offset distance of 1mm between the push capillary and sample capillary tips is sufficient to avoid leakage of quenchant/diluent into the bulk sample for push flow rates up to 95% of the pull flow rate. The maximum relative push flow rate was determined to be 90% of the pull flow rate experimentally. Delay between sampling and delivery to the HPLC was from 111±3s to 317±9s for pull flow rates from 1.0 to 3.0 μL/min in agreement with expected delays based on tubing volume. Response times were from 27±1s to 52±6s over the same flow rate range. The sampler was tested to determine the effects of sample viscosity. The sampler was also used to demonstrate periodic sampling capabilities. As a test of the system, it was used to monitor the base-catalyzed hydrolysis of aspirin for 1.5h, demonstrating its utility for monitoring an ongoing reaction.  相似文献   

10.
A single-channel flow injection (FI) manifold with spectrophotometric detection has been designed and fabricated for diazepam determination. A 100 microl sample and/or standard solution containing diazepam was injected into a flowing stream of 0.1 mol L(-1) hydrochloric acid with the optimum flow rate of 6.8 mL min(-1). As soon as the sample reached the detector, the FI signal as a peak was recorded at 360 nm. The optimum conditions for microg amounts of diazepam were achieved. A linear calibration graph over the range of 2-110 mg L(-1) diazepam was obtained with the regression equation Y = 0.2926X + 0.5896 (r2 = 0.9929). The method was very sensitive, since as little as 0.60 mg L(-1) could be detected; very reproducible with an RSD of 3.3% (n=11); and very rapid with a sampling rate of 100 h(-1). The limit of quantitation (10 sigma) was 2.0 mg L(-1). The proposed FI procedure has been satisfactorily applied to the quantitation of diazepam in commercial pharmaceutical formulations. The obtained results were in excellent agreement with those obtained by the conventional spectrophotometric method, verified by the student t-test at the 95% confidence level.  相似文献   

11.
Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C(18) (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L(-1) HCl in 0.5% MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C(18) monolithic column (25 mm × 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01% aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 μg L(-1) for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112% was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.  相似文献   

12.
王家斌  吴芳玲  赵琦 《色谱》2015,33(8):849-855
采用C18毛细管整体柱作为固相微萃取整体柱,构建在线固相微萃取-高效液相色谱联用系统,同步富集检测环境水样中的5种苯氧羧酸类除草剂。详细考察了联用系统运行条件对富集检测的影响。联用系统运行最佳参数为:固相微萃取整体柱长度20 cm,进样流速0.04 mL/min,进样13 min,洗脱流速0.02 mL/min,洗脱5 min。在最佳条件下,5种苯氧羧酸类除草剂的检出限为:9 μg/L (苯氧丙酸)、4 μg/L (2-(2-氯)-苯氧丙酸)、4 μg/L (2-(3-氯)-苯氧丙酸)、5 μg/L (2,4-二氯苯氧乙酸)、5 μg/L (2-(2,4-二氯苯氧基)丙酸)。与HPLC系统直接进样对比,联用系统对5种检测对象表现出优良的富集能力。5种苯氧羧酸类除草剂的回收率在79.0%~98.0%之间(RSD≤3.9%)。该方法成功应用于水样中5种苯氧羧酸类除草剂的检测,结果令人满意。  相似文献   

13.
建立了微透析取样-流动注射电化学检测法测定表柔比星与牛血清白蛋白体外结合参数的方法。流动相为pH 3.0的0.1 mol/L H3PO4-NaH2PO4缓冲液(含3.4×10﹣5mol/L Na2EDTA),流速为0.3 mL/min。电化学检测的工作电极为玻碳电极,工作电位为0.52V。表柔比星浓度在5.0×10-5~5.0×10-7 mol/L范围内与峰电流呈良好的线性关系,其相关系数为0.9997,检出限为2.0×10-7mol/L。结合微透析取样,实现了对表柔比星与牛血清白蛋白结合参数的测定。表柔比星与牛血清白蛋白的体外结合符合Scatchard曲线,结合常数和结合位点数分别为2.41×104L/mol和4.02。  相似文献   

14.
碘量法是测定管道输送天然气中硫化氢的一种经典方法,而管道输送天然气中硫化氢含量较低,按照GB/T11060.1–2010方法测定,取样量较大,取样时间长,影响工作效率。针对此问题,从两方面对碘量法进行改进:减小天然气取样量进行试验,并与国标规定取样量时的实验结果进行比对,确定最佳取样量;增大取样流量进行试验,并与国标规定取样流量时的实验结果进行比对,确定最佳取样流量。对硫化氢质量浓度为7.2~14.3,14.3~28.7 mg/m~3的天然气样品进行试验测定,结果表明,将天然气取样量减少为20 L,取样时间分别由200,100 min缩短为40 min;将天然气取样流量设定为750 m L/min,取样时间分别由200,100 min缩短为133,67 min。减少取样量或者提高取样流量,均能缩短管输天然气的取样时间,提高检测效率。  相似文献   

15.
Online monitoring by flow NMR spectroscopy is a powerful approach to study chemical reactions and processes, which can provide mechanistic understanding, and drive optimisations. However, some of the most useful methods for mixture analysis and reaction monitoring are not directly applicable in flow conditions. This is the case of classic diffusion-ordered NMR spectroscopy (DOSY) methods, which can be used to separate the spectral information for mixture's components. We describe a fast and flow-compatible diffusion NMR experiment that makes it possible to collect accurate diffusion data for samples flowing at up to 3 mL/min. We use it to monitor the synthesis of a Schiff base with a flow-tube with a time resolution of approximately 2 minutes. The one-shot flow-compatible diffusion NMR described here open many avenues for reaction monitoring applications.  相似文献   

16.
龙星宇  陈福南  邓茂 《分析化学》2012,(7):1076-1080
在酸性条件下,Ce?氧化Ru(bipy)32+生成Ru(bipy)33+,同时氧化卡托普利生成二硫化物中间活性态([RS-SR]*),Ru(bipy)33+和二硫化物中间活性态之间相互反应产生强烈的化学发光。基于此,根据发光试剂Ru(bipy)32+水溶性好、试剂稳定等特点,将其加入到流动相中,通过高效液相色谱分离,建立了柱后化学发光快速灵敏检测卡托普利的方法。在以甲醇-0.01mol/L KH2PO4-1g/L Ru(bipy)32+(80∶20∶2,V/V)为流动相,流速为0.9mL/min,8.0×10-4 mol/L Ce?的优化实验条件下,方法的线性范围为2.0×10-7~1.0×10-4 mol/L(R2=0.9988),检出限为6.0×10-8 mol/L(S/N=3),并对1×10-5 mol/L卡托普利平行测定11次,相对标准偏差(RSD)为1.8%。将本方法用于人体尿液中卡托普利含量的测定,结果令人满意。结合化学发光光谱,对该体系发光机理进行了探讨。  相似文献   

17.
A micromachined flow cell (overall size; 25 x 25 x 1 mm3) was designed for the fast determination of hydrogen peroxide, based on a luminol-H2O2 chemiluminescence reaction catalyzed by immobilized peroxidase (POD). The flow cell consisted of a sandwich of anisotropically etched silicon and glass chips and contained a spiral channel (20 turns, 50 cm long, 150 microm wide, 20 microm depth, channel volume 1.4 microl) and two holes (1 mm diameter). POD was covalently immobilized with 3-(trimethoxysilyl)propyldietylenetriamine and glutaraldehyde on the inner surface of the channel. The chip was placed in front of a window of a photomultiplier tube and used as a flow cell in a single-line flow-injection analysis system using a luminol solution as a carrier solution. The sample volume for one measurement was 0.2 microl. The maximal sampling rate was 315 h(-1) at a carrier solution flow rate of 10 microl min(-1). A calibration graph for H2O2 was linear for 5 nM - 5 microM; the detection limit (signal-to-noise = 3) was 1 nM (7 fg in 0.2 microl injection). The H2O2 concentration in rainwater was determined using this sensor system.  相似文献   

18.
The overall rate constant for the radical-radical reaction C2H5 + HO2 --> products has been determined at room temperature by means of time-resolved mass spectrometry using a laser photolysis/flow reactor combination. Excimer laser photolysis of gas mixtures containing ethane, hydrogen peroxide, and oxalyl chloride was employed to generate controlled concentrations of C2H5 and HO2 radicals by the fast H abstraction reactions of the primary radicals Cl and OH with C2H6 and H2O2, respectively. By careful adjustments of the radical precursor concentrations, the title reaction could be measured under almost pseudo-first-order conditions with the concentration of HO2 in large excess over that of C2H5. From detailed numerical simulations of the measured concentration-time profiles of C2H5 and HO2, the overall rate constant for the reaction was found to be k1(293 K) = (3.1 +/- 1.0) x 10(13) cm3 mol(-1) s(-1). C2H5O could be confirmed as a direct reaction product.  相似文献   

19.
Reversibility of cadmium sorption to calcite revisited   总被引:3,自引:0,他引:3  
Cadmium sorption to calcite was studied in aqueous solution at calco-carbonic (CO(2)-H(2)O-CaCO(3)) equilibrium and at concentrations below the solubility product of otavite (<10(-7) mol L(-1)). Experiments were conducted in a stirred flow-through reactor, lasting for 15 and 60 h at flow rates of 1.6 and 0.5 mL min(-1), respectively. Under both flow conditions, the cadmium breakthrough curves reached steady state after a flow time of about 50 reactor volumes, but different calcite saturation levels were achieved, which implied time-dependent sorption rates. Desorption of cadmium was induced by switching from Cd-containing to Cd-free solution in the reactor inflow. Reversibility of sorption was then evaluated by comparing amounts sorbed and desorbed over identical time intervals. On average, the desorption/sorption ratio was 95±10%. Desorption rates were close to those for sorption and showed the same time dependency: Initially, rates were fast and slowed down with time. "Irreversible" surface reactions such as solid-solution formation could not be inferred. In previous research, cadmium sorption was often shown to be partly irreversible. We surmise that calcite surface ripening is conditioned by the concentration of lattice-building ions in the EDL. At calco-carbonic equilibrium, these ion concentrations at the surface are lowest. Therefore, irreversible binding of cadmium is not favoured.  相似文献   

20.
对槲寄生中的有效成分高圣草素-7-O-β-D-葡萄糖苷进行了分离和结构鉴定,并对其含量进行了分析。色谱条件:C18柱(200 mm×4.6 mm i.d., 5 μm),流动相为乙腈-0.5%冰醋酸水溶液(体积比为18∶82),流速为1.0 mL/min,柱温为30 ℃,检测波长为284 nm,进样量为10 μL。结果表明,高圣草素-7-O-β-D-葡萄糖苷的峰面积与其质量浓度有良好的线性关系,相关系数r为0.9997;方法的加标回收率为96.0%~100.1%。该方法简便、快速、准确,精密度好,可作为槲寄生质量控制的一个有效方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号