首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Ohne Zusammenfassung
Investigation of the reaction mechanism of carbohydrate specific receptor proteins (Lectins)
  相似文献   

3.
Ohne Zusammenfassung
Quantitative image analysis of the fruiting body formation in the ascomycete sordaria macrospora
  相似文献   

4.
Die Übersetzung basiert auf den „Definitions of Terms for Diffusion in the Solid State“ der Commission on High Temperature Materials and Solid State Chemistry der International Union of Pure and Applied Chemistry, veröffentlicht in Pure Appl. Chem. 1999 , 71, 1307–1325. Das Original wurde von M. Kizilyalli (Middle East Technical University, Ankara, Türkei), J. Corish (Trinity College, University of Dublin, Irland) und R. Metselaar (Technische Universiteit Eindhoven, Niederlande) für die Veröffentlichung vorbereitet.  相似文献   

5.
Summary The first complete mass spectra of unprotected dinucleotides e.g. TpT, GpU, ApC, and CpA are reported. In all cases these spectra make possible the determination of the molecular weight. In addition structural information about the building blocks of the dinucleotides can be obtained.
Hochauflösungs-Felddesorptions-MassenspektrometrieIV. Dinucleotide
Zusammenfassung Die ersten vollständigen Massenspektren von underivatisierten Dinucleotiden wie TpT, GpU, ApC und CpA werden beschrieben. In allen Fällen ermöglicht die Felddesorptions-Massenspektrometrie die Bestimmung des Molekulargewichtes. Zusätzlich liefert die Methode wichtige Strukturinformation über die Bausteine der Dinucleotide.

Abbreviations MS mass spectrometry, mass spectrum - TMS trimethylsilyl - FD field desorption - M molecular ion - HR high resolution - e.h.c. emitter heating current - BAT best anode temperature Part III: Schulten, H.-R., Kümmler, D.: Sulphonic acids and sulphonates. Z. Anal. Chem.278, 13 (1976).  相似文献   

6.
7.
在pH为6.0的B-R缓冲溶液中,丙酸睾丸素于电位-1.4V(vs.SCE)左右处出现一个灵敏的附阴溶出峰。经5min富集后,阴极溶出峰电流与浓度在1.38×10^-^8-7.3×10^-^8mol/L范围内成线笥关系,该方法用于注射液中丙酸睾丸素含量测定,回收率80%-86%。检测下限为4.1×10^-^9mol/L。  相似文献   

8.
9.
Zusammenfassung Ergebnisse der direkten Auflösung von unbestrahltem Mischcarbid-Brennstoff in Salpetersäure in Abhängigkeit von der Normalität und der Temperatur werden diskutiert. Der Reaktionsverlauf wird durch Messung der Zunahme des Gesamtdrucks, durch Gasanalyse und durch potentiometrische Titration bzw. durch spektrophotometrische Bestimmung des Uran- und Plutoniumgehalts der Lösung verfolgt. Drei Reaktionsphasen werden identifiziert. Nach abgeschlossener Auflösung (Phase II) setzt sich die Gasentwicklung fort. In der folgenden Phase III steigt der Gehalt an Kohlendioxid in der Gasphase, was auf eine Oxidation organischer Verbindungen in der Lösung hinweist. Absorptionsspektren der Lösung zeigen die Anwesenheit von U(VI) und Pu(IV) sowie eine starke, organischen Verbindungen zugeschriebene Bande unterhalb 550 nm. Mehrkomponentenanalyse unter Berücksichtigung dieser Bande erlaubt die Bestimmung des Uran- und Plutoniumgehaltes der Lösung, sowie der Wertigkeiten dieser Elemente. Die Interferenz der Bande kann durch Behandlung mit Oxidationsmitteln behoben werden. Das U/Pu-Verhältnis bleibt während der Auflösung konstant.Herrn Prof. Dr. E. Blasius zum 60. Geburtstag gewidmet.  相似文献   

10.
Zusammenfassung Bei der potentiometrischen Bestimmung von Fluorid mit Hilfe der fluoridsensitiven Elektrode ist das Lösen des Festkörpers und die selektive Abtrennung des Fluorids von störenden Begleitstoffen notwendig, was am besten als Fluorwasserstoff durch die bewährte Wasserdampfdestillation mit Perchlorsäure erfolgt. Als Absorptionsflüssigkeit für den Fluorwasserstoff wurde 0,006 M AlCl3/20% Na-NO3 vom pH 3 verwendet; die Absorptionskapazität wurde bestimmt und die Komplexgleichgewichte in dieser Lösung in Abhängigkeit vom pH-Wert berechnet. Dieselbe Lösung kann auch zur Absorption von Fluorid aus Luft empfohlen werden.Die potentiometrische Bestimmung von Fluorid kann, wie bereits beschrieben, auch in Gegenwart von Aluminiumionen durch Zugabe von Tiron erfolgen. Dadurch wird der Bestimmungsbereich so ausgedehnt, daß keine feste Verdünnung der Probe durch Verreiben mit inertem Material notwendig ist.Der direkte Naßaufschluß von Festkörpern mit Aluminiumlösungen verlief sehr langsam und nicht quantitativ, so daß die Destillation nicht zu umgehen ist.
Potentiometric determination of fluoride in solids
Summary It is necessary for the determination of fluoride by means of the fiuoride-sensitive electrode to dissolve the solids and to separate fluoride from interfering substances. This can be done best as hydrogen fluoride by means of the approved steamdistillation with the aid of perchloric acid. 0.006 M AlCl3/20% NaNO3 of pH 3 was used as liquid for the absorption. The capacity of absorption was determined and the equilibria of the complexes present in this solution were calculated at various pH values. The same solution can also be recommended for absorption of fluoride from air.As recently described, the potentiometric determination of fluoride can also be done in presence of aluminium ions with the addition of Tiron. The range of determination is extended so far, that dilution of the solid sample by grinding with inert material is not necessary any more.The direct wet dissolution of solids by aluminium solutions worked very slowly and was not quantitative. Hence, distillation cannot be avoided.
Die Apatitproben wurden uns freundlicherweise von Herrn Wiss. Oberrat Dr. Pecherer vom Institut für Mineralogie und Kristallographie der Universität Wien zur Verfügung gestellt, wofür an dieser Stelle aufrichtigst gedankt wird. Die Nummern der Proben beziehen sich auf die Sammlung dieses Instituts.  相似文献   

11.
Ohne Zusammenfassung
Enzyme-immunoassay (EIA) of Hepatitis B surface antigen (HBsAg) in microtiter plates
  相似文献   

12.
Summary Pertinent, previous studies of the oxidation of SO2 in the atmosphere are briefly reviewed. A project dealing with the conversion in the plume from an oil-fired power station is described in greater detail. Measurements were performed from an aircraft and included continuous registration of NOx, SO2 and ozone concentrations. The possibility of using NOx as an internal tracer is discussed; also the use of the inert tracer SF6 is treated and a special detector for the continuous registration of SF6 in relative concentrations down to 10–6 ppm is described. Preliminary results indicate a half-life for SO2 in the plume of about half an hour.
Umsetzung von Schwefeldioxid in der Atmosphäre
Zusammenfassung Einschlägige frühere Studien über die Oxidation von SO2 in der Atmosphäre werden kurz diskutiert. Ein Projekt zum Studium der Umwandlung im Abrauch eines ölbefeuerten Kraftwerkes wird im Detail beschrieben. Die Messungen wurden mit Hilfe eines Flugzeuges vorgenommen und schließen die kontinuierliche Aufzeichnung von NOx-, SO2- und Ozon-Konzentrationen ein. Die Möglichkeit der Verwendung von NOx als interner Indicator wird diskutiert. Außerdem wird der Gebrauch des inerten Indicators SF6 behandelt und ein spezieller Detektor für die kontinuierliche Aufzeichnung von SF6 mit relativen Konzentrationen bis herunter auf 10–6 ppm beschrieben. Vorläufige Ergebnisse deuten auf eine Halbwertszeit von SO2 im Abrauch von etwa 30 min hin.
Presented at the 6th Annual Symposium on Recent Advances in the Analytical Chemistry of Pollutants, April 21–23, 1976; Vienna, Austria  相似文献   

13.
14.
Ohne Zusammenfassung
Quantitative investigations on neurons in the cerebral cortex of hypoxic cats by image analysis
  相似文献   

15.
Ohne Zusammenfassung
Determination of antibodies to Cytomegalovirus (CMV), Varicella/Zoster-Virus (VZV) and Herpes simplex-Virus Type 1 (HSV-1) by the Enzyme-Linked-Immunosorbent-Assay (ELISA)
  相似文献   

16.
Ohne ZusammenfassungHerrn K. Bullik danke ich für wertvolle Hilfe bei der Durchführung der Messungen.  相似文献   

17.
Summary For the examples shown in this study in all cases FD-MS allowed the determination of the molecular weight and the elemental composition. Some of the characteristic features of sulphonic acids and sulphonates in field desorption are described. The method is obviously very well suited for the analysis of non-volatile technical products (e.g. dyestuffs, detergents, drugs). Information about the molecular weight, the structure, organic and inorganic by-products and impurities is obtained and thus the applicability of FD-MS to the analysis of actual analytical problems is clearly demonstrated.
Hochauflösungs-Felddesorptions-MassenspektrometrieIII. Sulfonsäuren und Sulfonate
Zusammenfassung Für die untersuchten Verbindungen ergab FD-MS in allen Fällen das Molekulargewicht und die Bruttoformel. Einige der charakteristischen Merkmale von Sulfonsäuren und Sulfonaten bei der Felddesorption werden beschrieben. Die Methode ist für die Analyse nichtflüchtiger, technischer Produkte (z. B. Farbstoffe, Detergentien, Pharmazeutica) sehr gut geeignet. Sie liefert Informationen über das Molekulargewicht, die Struktur, organische und anorganische Nebenprodukte und Verunreinigungen.
Part II.: Schulten, H.-R., Games, D. E.: Glycosides. Biomed. Mass Spectrom. 1, 120 (1974).  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号