首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polyacrylamide gel electrophoresis (PAGE) is used frequently for isolation and purification of DNA fragments. In the present study, DNA fragments extracted from polyacrylamide gels showed significant band broadening in capillary electrophoresis (CE). A pHY300PLK (a shuttle vector functioning in Escherichia coli and Bacillus subtilis) marker, which contained nine fragments ranging from 80 to 4870 bp, was separated by PAGE, and each fragment was isolated by phenol/chloroform extraction and ethanol precipitation. After extraction from the polyacrylamide gel, the peaks of the isolated DNA fragments exhibited band broadening in CE, where a linear poly(ethylene oxide) was used as a sieving matrix. The theoretical plate numbers of the DNA fragments contained in the pHY300PLK marker were >106 for all the fragments before extraction. However, the DNA fragments extracted from the polyacrylamide gel showed decreased theoretical plate numbers (5–20 times smaller). The degradation of the theoretical plate number was significant for middle sizes of the DNA fragments ranging from 489 to 1360 bp, whereas the largest and smallest fragments (80 and 4870 bp) had no obvious influence. The band broadening was attributed to contamination of the DNA fragments by polyacrylamide fibers during the separation and extraction process.  相似文献   

2.
A high-performance capillary electrophoresis system with a polysiloxane-coated capillary and polymeric buffer additives was investigated for the analysis of DNA restriction fragments and polymerase chain reaction (PCR) products. Mobility data and Ferguson plots of the DNA fragments at different polymer (hydroxypropylmethylcellulose) concentrations indicated that effective molecular sieving was obtained consistent with existing data of conventional gel electrophoresis and with recent HPCE data. The precision and peak efficiency were excellent and the system was applied to the analysis of specific co-amplified DNA sequences (HIV-1 and HLA-DQ-alpha). After PCR, ultrafiltration was used in the sample preparation step to desalt the sample and to remove superfluous PCR reaction products. Electrokinetic injection was used for sample introduction into the capillary. The addition of ethidium bromide to the buffer resulted in longer migration times of DNA fragments and better peak resolution. During HPCE, an artifact associated with dilute DNA solutions leading to the appearance of extra peaks in the electropherogram was found.  相似文献   

3.
An automatic DNA fragment collector using capillary array gel electrophoresis has been developed. A sheath flow technique is used for not only detection but also collection of DNA fragments. In a sheath flow cell, the DNA fragments separated by 16 capillaries flow independently into corresponding sampling capillaries. The fraction collector consists of 16 sampling trays and each sampling tray is set beneath each end of the sampling capillaries to collect the flow-through DNA fragments. Certain DNA fragments are automatically sorted by controlling the movement of the sampling trays according to the signals from the system. The collector experimentally separated two mixtures of polymerase chain reaction (PCR) products: one prepared by using eight different sizes (base lengths from 161 to 562) of DNAs; and the other prepared by a differential display (DD) method with cDNA fragments. Collected DNA fragments are amplified by PCR and measured by electrophoresis. DNA fragments with base length differences of one (base lengths 363 and 364) were successfully separated. A separated DNA fragment from the DD sample was also successfully sequenced. In addition, differentially expressed DNA fragments were automatically sorted by comparative analysis, in which two similar cDNA fragment groups, labeled by two different fluorophores, respectively, were analyzed in the same gel-filled capillary. These results show that the automatic DNA fragment collector is useful for gene hunting in research fields such as drug discovery and DNA diagnostics.  相似文献   

4.
A multi‐channel microchip electrophoresis using a programmed step electric field strength (PSEFS) method was investigated for fast parallel detection of feline panleukopenia virus (FPV) DNA. An expanded laser beam, a 10× objective lens, and a charge‐coupled device camera were used to simultaneously detect the separations in three parallel channels using laser‐induced fluorescence detection. The parallel separations of a 100‐bp DNA ladder were demonstrated on the system using a sieving gel matrix of 0.5% poly(ethylene oxide) (Mr = 8 000 000) in the individual channels. In addition, the PSEFS method was also applied for faster DNA separation without loss of resolving power. A DNA size marker, FPV DNA sample, and a negative control were simultaneously analyzed with single‐run and one‐step detection. The FPV DNA was clearly distinguished within 30 s, which was more than 100 times faster than with conventional slab gel electrophoresis. The proposed multi‐channel microchip electrophoresis with PSEFS was demonstrated to be a simple and powerful diagnostic method to analyze multiple disease‐related DNA fragments in parallel with high speed, throughput, and accuracy.  相似文献   

5.
Although automated DNA sequencers are becoming popular, their sensitivity in detecting DNA bands is still around 10(-17) mole/band. The sensitivity of a system depends on the laser power, labeling fluorophore, and the fluorescence-collecting yield. The emission and photodestruction cross-sections of the fluorophores are critical in optimizing the irradiated laser power and the migration speeds of DNA fragments to achieve high sensitivity. We investigated photodestruction cross-sections of various fluorophores to optimize the irradiation laser power. In addition, we used a cylindrical lens system to improve the fluorescence-collecting yield of a DNA sequencer using side entry laser irradiation. Fluoresceine isothiocyanate (FITC) commonly used in fluorescence studies, is very photo-destructive, the cross-section of the destruction being about 3.8 x 10(-20) cm2 in buffer solution while that of Texas Red is 1.5 x 10(-21) cm2. When the time for DNA fragments to transit through the irradiated region is 11 s, the optimum laser powers are 0.9 mW, with an Ar laser (488 nm) for FITC-DNA, and 18 mW, with an He-Ne laser (594 nm) for Texas Red DNA. We have developed a DNA sequencer, with a cylindrical lens system which improves the fluorescence-collecting efficiency by a factor of 4, and an He-Ne laser (5 mW). Although the sequencer uses a slab gel, an ultra-high sensitivity of 5 x 10(-20) mole/band (S/N-4) was achieved under optimized conditions.  相似文献   

6.
A high‐speed DNA fragment separation system based on an on‐line combination of capillary ITP with CZE (CITP‐CZE) and using UV detection at 260 nm was developed. A novel CITP‐CZE buffer system of pH 6.1 was designed for the separation of ten DNA fragments with sizes ranging from 100 to 1000 bp. An effect of underivatized α‐, β‐ and γ‐cyclodextrins on the resolution of DNA fragments in the CZE step of the CITP‐CZE combination was systematically investigated. Methylhydroxyethylcellulose present in the BGE was used to eliminate the EOF. DNA ladder fragments were separated within 10 min with LODs in the range of 1–5 ng/μL (S/N = 3). The RSDs of the migration time and peak area of individual DNA fragments were in the range of 1–3 and 3–9%, respectively. The developed CITP‐CZE system was further applied to the analysis of digest plasmid DNA samples.  相似文献   

7.
A methodology has been developed which significantly reduces the linear dimension necessary for the electrophoretic separation of DNA fragments and oligonucleotides. DNA fragments are rapidly separated into compact, resolvable microscopic banding patterns which can be detected using a high-resolution electronic imaging system. Separations can be carried out in either capillary tube or thin-layer (slab) microgel formats of one centimeter or less in length. The complete separation of all eleven fragments (1353 to 72 base pairs) of the pi X174 DNA/HaeIII restriction ladder was achieved in a total running distance of less than 2 mm and in less than 2 min. The observed band widths for the larger fragments (1353-603 bp) ranged from 18 to 25 microns, with the intermediate and smaller fragments (310 to 72 bp) ranging from 30 microns to 60 microns. The ethidium bromide-stained microgels were analyzed using an epifluorescent microscope combined with an intensified charged coupled device imaging system. In other experiments, single-base resolution of fluoresceinated oligonucleotides in the 20-30 nucleotide range was demonstrated. DNA sequencing may be possible with further optimization. This new methodology departs from the conventional gel formulations and electrophoretic procedures used for the separation DNA fragments. High voltage gradients and the use of highly concentrated and crosslinked homogeneous polyacrylamide gels effects the rapid separation of DNA fragments in very short distances. Analysis of the microgels with proteins of known size (Stokes radius) indicates that separations are occurring in gels with pore sizes close to the diameter of double-stranded DNA.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
In this work, we demonstrate a rapid protocol to address one of the major barriers that exists in the fabrication of chip devices, creating the micron-sized structures in the substrate material. This approach makes it possible to design, produce, and fabricate a microfluidic system with channel features >10 microm in poly(dimethylsiloxane)(PDMS) in under 8 hours utilizing instrumentation common to most machine shops. The procedure involves the creation of a master template with negative features, using high precision machining. This master is then employed to create an acrylic mold that is used in the final fabrication step to cast channel structures into the PDMS substrate. The performance of the microfluidic system prepared using this fabrication procedure is evaluated by constructing a miniaturized capillary gel electrophoresis (micro-CGE) system for the analysis of DNA fragments. Agarose is utilized as the sieving medium in the micro-CGE device and is shown to give reproducible (RSD (n= 34) approximately 5.0%) results for about 34 individual separations without replenishing the gel. To demonstrate the functionality of the micro-CGE device, a DNA restriction ladder (spanning 26-700 base pairs) and DNA fragments generated by PCR are separated and detected with laser-induced fluorescence (LIF). The microchip is shown to achieve a separation efficiency of 2.53 x 10(5) plates m(-1).  相似文献   

9.
Chen X  Ugaz VM 《Electrophoresis》2006,27(2):387-393
In this paper, we describe the construction of a simple yet powerful gel electrophoresis apparatus that can be used to perform size-selective separations of DNA fragments in virtually any laboratory. This system employs a microslab gel format with a novel gel casting technique that eliminates the need for delicate combs to define sample loading wells. The compact size of the microslab gel format allows rapid separations to be performed at low voltages using submicroliter sample volumes. Real time fluorescence detection of the migrating DNA fragments is accomplished using an inexpensive digital microscope that directly connects to any PC with a USB interface. The microscope is readily adaptable for this application by replacing its white light source with a blue light-emitting diode (LED) and adding an appropriate emission filter. Both polyacrylamide and agarose gels can be used as separation matrices. Separation performance was characterized using standard dsDNA ladders, and correct sizing of a 191 bp PCR product was achieved in 15 min. The low cost and simplicity of this system makes it ideally suited for use in a variety of laboratory and educational settings.  相似文献   

10.
We present a new method for the linearization and alignment of data traces generated by multilane automated DNA sequencing instruments. Application of this method to data generated with the Visible Genetics Open Gene DNA sequencing system (using MicroCel 700 gel cassettes, with a 25 cm separation distance) allows read lengths of > 1,000 nucleotides to be routinely obtained with high confidence and > 97% accuracy. This represents an increase of 10-15% in average read length, relative to data from this system that have not been processed in the fashion described herein. Most importantly, the linearization and alignment method allows usable sequence to be obtained from a fraction of 10-15% of data sets which, because of original trace misalignment problems, would otherwise have to be discarded. Our method involves adding electrophoretic calibration standards to the DNA sequencing fragments. The calibration standards are labeled with a dye that differs spectrally from the dye attached to the sequencing fragments. The calibration standards are identical in all the lanes. Analysis of the mobilities of the calibration standards allows correction for both systematic and random variation of electrophoretic properties between gel lanes. We have successfully used this method with two-dye and three-dye DNA sequencing instruments.  相似文献   

11.
A novel polyacrylamide gel-based femtolitre microchamber system for performing single-molecule restriction enzyme assay on freely-suspended DNA molecules and subsequent DNA electrostretching by applying an alternating electric field has been developed. We attempted the integration by firstly initiating restriction enzyme reaction on a fluorescent-stained lambdaDNA molecule, encapsulated in a microchamber, using magnesium as an external trigger. Upon complete digestion, the cleaved DNA fragments were electrostretched to analyze the DNA lengths optically. The critical parameters for electrostretching of encapsulated DNA were investigated and optimum stretching was achieved by using 1.5 kHz pulses with electric field strength in the order of 10(3) V cm(-1) in 7% linear polyacrylamide (LPA) solution. LPA was adopted to minimize the adverse effects of ionic thermal agitation on molecular dielectrophoretic elongation in the microchamber. In our experiments, as the fragments were not immobilized throughout the entire protocol, it was found from repeated tests that digestion always occurred, producing the expected number of cleaved fragments. This versatile microchamber approach realized direct observation of these biological reactions on real-time basis at a single-molecule level. Furthermore, with the employment of porous polyacrylamide gel, the effective manipulation of DNA assays and the ability to combine conventionally independent bioanalytical processes have been demonstrated.  相似文献   

12.
A low cost, 0.75-mW helium neon laser, operating in the green region at 534.5 nm, is used to excite fluorescence from tetramethylrhodamine isothiocyanate-labelled DNA fragments that have been separated by capillary gel electrophoresis. The detection limit (3 sigma) for the dye is 500 ymol [1 yoctomole (1 ymol) = 10(-24) mol] or 300 analyte molecules in capillary zone electrophoresis; the detection limit for labeled primer separated by capillary gel electrophoresis is 2 zmol [1 zeptomole (1 zmol) = 10(-21) mol]. The Richardson-Tabor peak-height encoded sequencing technique is used to prepare DNA sequencing samples. In 6% T, 5% C acrylamide, 7 M urea gels, sequencing rates of 300 bases/hour are produced at an electric field strength of 200 V/cm; unfortunately, the data are plagued by compressions. These compressions are eliminated with addition of 20% formamide to the sequencing gel; the gel runs slowly and sequencing data are generated at a rate of about 70 bases/hour.  相似文献   

13.
DNA fragments up to 9 kb in size were stacked and separated by polyacrylamide gel electrophoresis, and those up to 50 kb in size by agarose gel electrophoresis, using a discontinuous buffer system. Polyacrylamide gels at pH 8.9, 2 degrees C, 0.01 M ionic strength, yielded sharp bands with DNA loads of 8 micrograms/cm2 of gel of a mixture of 19 DNA fragments in the size range of 72-23130 bp, while agarose gels at pH 8.5, 25 degrees C, provided well-resolved, unperturbed bands at 0.04 M ionic strength with DNA loads of 1 microgram/cm2 of the same mixture. Note that the ionic strength of the agarose gels is comparable to the conventionally used 0.5 x TBE (Tris-borate-EDTA) buffer, while that successfully applied to polyacrylamide is seven-fold less than the ionic strength of conventionally used 1 x TBE buffer, with a substantially shorter duration of electrophoresis as a result. The application of a discontinuous buffer system to the gel electrophoresis of DNA results in (i) Band identification by Rf, the migration distance relative to a sharply defined "buffer front" (moving boundary). This is sufficiently labor saving, compared to determining absolute mobilities, so as to render practical the expression of bands as numbers, with benefits for data storage, statistical manipulations and physico-chemical exploitation of mobility data. The use of Rf's also circumvents loss of precision in mobility measurement resulting from progressive band spreading of dye bands used as a front. (ii) A uniformly and highly concentrated starting zone, beneficial to resolution, is obtained, without the losses by which separate concentration steps are usually burdened.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
The image processing system, LabEye Profile, calculates the size of DNA restriction fragments according to the formula MD = f(x); x = 1/log bp. The migration distances (MD) of known fragment sizes are interpolated by the use of cubic splines. Cubic splines are also used to correct for gel distortions. A comparison to the Biotrac system, which uses the reciprocal method, gives almost identical standard deviations for calculated sizes compared to known sizes, 0.88% for LabEye Profile and 0.89% for Biotrac. The measurement error for LabEye Profile is 0.24% of the size of the fragments.  相似文献   

15.
Restriction fragments of pUC19 DNA were irradiated by various doses of UV light and analyzed by denaturing (alkaline) agarose gel electrophoresis. The irradiation generated retarded species whose mobility indicated two crosslinked DNA strands. Quantitative analysis of the experimental data provided an empirical equation relating the fraction of crosslinked DNA molecules to their length and to the dose of their irradiation by UV light. This equation can be used to predict the crosslinking behavior of pUC19-like DNA molecules whose primary structures do not much differ from a random nucleotide sequence. The amount of interstrand crosslinks increased with the (A+T) content of the pUC19 DNA fragments but the dependence was not clear-cut to indicate that oligonucleotide composition of DNA played a significant role as well.  相似文献   

16.
Allison SA  Li Z  Reed D  Stellwagen NC 《Electrophoresis》2002,23(16):2678-2689
The technique of Brownian dynamics is used to model the electrophoretic mobility of spherical and rod-like particles in a three-dimensional cubic gel lattice. In addition to excluded volume interactions between the migrating particle and the gel, direct interactions are also included. The methodology is first applied to spherical particles in the absence of direct interactions and the resulting mobilities are shown to agree with independent studies. The methodology is then applied to rod-like models of short duplex DNA fragments 10-50 base pairs in length. In the absence of direct interactions between gel and DNA, calculated mobilities show a much weaker dependence on gel concentration than observed in experiments of DNA in Tris-acetate buffer and polyacrylamide gels. When an attractive interaction between gel and DNA of approximately -0.3 k(B)T per base pair at contact is included, good agreement between calculated and experimental mobilities is achieved.  相似文献   

17.
A novel, rapid and efficient separation method is described for the analysis of double stranded (ds) DNA fragments in the form of horizontal ultra-thin-layer agarose gel electrophoresis. This separation technique combines the multilane, high-throughput separation format of agarose slab gel electrophoresis with the excellent performance of capillary electrophoresis. The electrophoretic separation of the fluorophore (Cy5)-labeled dsDNA molecules were imaged in real time by a scanning laser-induced fluorescence/avalanche photodiode detection system. Effects of the gel concentration (Ferguson plot) and separation temperature (Arrhenius plot) on the migration characteristics of the DNA fragments are discussed. An important genotyping application is also shown by characterizing the polymorphic region (2× or 4×48 base pair repeats) of the dopamine D4 receptor gene (D4DR, exon III region) for ten individuals, using PCR technology with Cy5-labeled primers and ultra-thin-layer agarose gel electrophoresis.  相似文献   

18.
A lesion-specific enzyme-induced DNA strand break assay was developed for an oligonucleotide chip for the determination of UVB-induced cyclobutane pyrimidine dimers (CPDs). A 20-mer of fluorophore-labeled and biotinylated oligonucleotide was immobilized on the chip. CPDs in DNA on the chip were formed by UVB irradiation (312 nm). T4 endonuclease V (T4N5) was used to excise the CPD site as T4N5 sensitively and specifically detects CPDs. The fluorophore-labeled DNA fragments were detected by a laser-induced fluorescence (LIF) detection system. The number of CPDs induced by UVB was determined based on a mathematical equation obtained from a predetermined calibration curve. The yield of UVB-induced CPDs was 1.73 CPDs per megabase per (kJ/m2). The reliability of this value was proved by its similarity to reference values obtained from gel electrophoresis. The developed assay has strong potential to quantify most kinds of UV-induced DNA lesions.  相似文献   

19.
An integrated on-line system is developed for DNA sequencing at the nanoliter scale. The technique involves the use of a nanoreactor for small-volume cycle-sequencing reaction, capillary zone electrophoresis (CZE) for purification of the sequencing fragments, and capillary gel electrophoresis (CGE) for separation of the purified DNA fragments. The nanoreactor and CZE are integrated into one capillary, where a 100-nl dye-labeled terminator cycle-sequencing reaction is carried out followed by CZE to separate excess dye-labeled terminators from the sequencing fragments. On-line electrokinetic injection of the purified DNA fragments into the CGE system is accomplished at a small-volume tee connector by which the CZE capillary is interfaced to the CGE system. The utility of the system is demonstrated in sequencing nanoliter volumes of single-stranded DNA (M13mp18) and double-stranded DNA (pGEM). The use of voltage to drive both CZE and CGE makes it feasible for automation and future adaptation of the whole system to a microchip.  相似文献   

20.
We are demonstrating a cost-effective multichannel capillary electrophoresis system for a high-efficiency double-stranded DNA (dsDNA) fragments analysis. This bench-type high-performance DNA analysis (HDA) system uses fluorescence-type detection with inexpensive solid-state light sources and nonmoving integrated emission collection micro-optics. DNA samples are analyzed simultaneously by using a multiple usage and disposable multicapillary cartridge, which contains integrated capillary channels, optical fibers and an integrated sieving gel reservoir. Using commercially available dsDNA size markers as indicators, the HDA system provides high resolving power in 7 min separations. The system can hold a total of 192 samples in two 96-well polymerase chain reaction (PCR) plates, which can be automatically analyzed within 2.5 h. This affordable system can be used in laboratories to replace slab gel electrophoresis for routine and high-throughput dsDNA analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏