共查询到20条相似文献,搜索用时 14 毫秒
1.
Bhatt J Jangid A Shetty R Shah B Kambli S Subbaiah G Singh S 《Biomedical chromatography : BMC》2006,20(8):736-742
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem. 相似文献
2.
Xue Li Xiaowei Fang Zhiqiang Yu Guoying Sheng Minghong Wu Jiamo Fu Huanwen Chen 《Analytica chimica acta》2012
Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI–MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 μg L−1. Over the concentration range investigated (0.05–10 mg L−1), the calibration curve was obtained with satisfactory linearity (R2 = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1–11.8% (n = 6) and 4.1–11.3% (n = 6), respectively. The isotope dilution EESI–MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85–111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI–MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories. 相似文献
3.
Hernández F Sancho JV Pozo OJ 《Rapid communications in mass spectrometry : RCM》2002,16(18):1766-1773
A novel and rapid procedure based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of dialkyl phosphates (metabolites of organophosphorus pesticides) in human urine has been developed. After addition of 40 mM tetrabutylammonium acetate, 10 microL of urine sample were directly injected into the LC/MS/MS system. The method was validated yielding calibration curves with correlation coefficients greater than 0.997 and repeatability coefficient of variation (CV) lower than 9%. The accuracy and precision were evaluated by direct injection of spiked samples at 10 and 100 microg/L obtaining recoveries between 78 and 119% with coefficients of variation below 12%. Limits of detection of 1 microg/L for diethyl phosphate (DEP), diethylthiophosphate (DETP) and diethyldithiophosphate (DEDTP) and 2 microg/L for dimethyldithiophosphate (DMDTP) were achieved, all the analytes being detected in negative ion mode. The fragmentation pathway of dialkyl phosphates allowed us the use of an additional transition for confirmation in order to improve their identification in real-world samples. The applicability of the LC/MS/MS method was demonstrated by applying it to the analysis of urine samples of farmers exposed to the organophosphorus pesticide chlorpyrifos. Good correlation between application of the product in the field (citrus orchards), concentration levels of dialkyl phosphates and levels of the chlorpyrifos-specific metabolite (1,3,5-trichloro-2-pyridinol) was obtained. 相似文献
4.
Trace amounts of diuretics were determined in human urine by hollow fiber liquid-phase microextraction (LPME) combined with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) in this study. Chromatography was performed on a C(8) reversed-phase column. A 25 microL n-octanol was used to extract analytes in urine. Extraction was optimized using a pH 2 solution spiked with 0.15 g/mL NaCl for 40 min at 40 degrees C with 1010 rpm stirring. The limits of detection of diuretics in urine were 0.3-6.8 ng/mL, and linearity range was 1-1000 ng/mL. Recoveries of spiked 50 ng/mL diuretics were 97.7-102.5%. The intra-day precision and inter-day precision were 3-18% and 4-21%, respectively. The diuretics concentration profiles in patient urine were also determined. The results of this study reveal the adequacy of LPME-LC-MS/MS method for analyzing diuretics in urine and quantification limits exceed World Anti-Doping Agency requirements. 相似文献
5.
Determination of quaternary ammonium pesticides by liquid chromatography-electrospray tandem mass spectrometry 总被引:4,自引:0,他引:4
A method for the direct determination of paraquat, diquat, chlormequat and difenzoquat in water samples, using an on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry system was developed. No sample preparation was required and the detection limits were below the European Union maximum residue levels. The chromatographic separation was performed using an XTera MS C8 column. The concentration of the ion pair reagent, the pH and the gradient elution were optimized to give high recoveries and good chromatographic resolution between quats. The detection was carried out using an ion trap as mass analyzer. Parameters such as the magnitude and duration of the resonant excitation voltage and the magnitude of the trapping RF voltage for full scan tandem mass spectrometry (MS-MS) experiments were studied to establish the optimal experimental conditions. Moreover, the accurate optimization of these parameters allowed MS-MS experiments of low mass ions, below m/z 200, providing unambiguous peak identification. Finally, the reproducibility of the proposed method was shown by good run-to-run and day-to-day precision values and its applicability to the determination of quats in drinking water was evaluated using spiked samples. 相似文献
6.
A high-performance liquid chromatography-mass spectrometry method has been developed for the simultaneous determination of native carnitine and eight acylcarnitines in urine. The procedure uses a solid-phase extraction on a cation-exchange column and the separation is performed without derivatization within 17 min on a reversed-phase C8 column in the presence of a volatile ion-pairing reagent. The detector was an ion trap mass spectrometer and quantification was carried out in the MS-MS mode. Validation was done for aqueous standards at ranges between 0.75 and 200 micromol/l, depending on the compound. Carnitine was quantified in urine and comparison with a radioenzymatic assay gave a satisfactory correlation (R2 = 0.981). The assay could be successfully applied to the diagnostic of pathological acylcarnitines profile of metabolic disorders in urines of patients suffering from different organic acidurias. 相似文献
7.
Benton CM Couchman L Marsden JT Rees DC Moniz C Lim CK 《Biomedical chromatography : BMC》2012,26(8):1033-1040
Urinary concentrations of 5-aminolaevulinic acid (ALA) and porphobilinogen (PBG) are elevated in patients with acute hepatic porphyrias, especially during acute attacks. Current assays require lengthy sample pre-treatment and derivatisation steps. We report here a rapid, sensitive and specific hydrophilic interaction liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, for the direct and simultaneous quantitation of ALA and PBG in urine following simple dilution with acetonitrile and centrifugation prior to injection. ALA and PBG were detected using selected reaction monitoring mode, following positive electrospray ionisation. Urine samples (N?=?46) from active and latent mutation-confirmed acute hepatic porphyria patients and normal subjects (N?=?45) were analysed and the results compared with those of a commercially available spectrophotometric method. The validated calibration range was 3-3000?μmol/L for ALA and 2-2000?μmol/L for PBG. For both analytes, imprecision (relative standard deviation) was less than 5% and accuracy (percentage nominal concentrations) was between 88 and 109%. The lower limit of quantitation was 0.1 μmol/L for both analytes. The calculated LC-MS/MS and spectrophotometric results from patient samples compared well [Pearson correlation (r2) of 0.99 and 0.95, for ALA and PBG, respectively]. The method was successfully applied to the measurement of ALA and PBG in urine samples for the screening, biochemical diagnosis and treatment monitoring of patients with acute hepatic porphyrias. 相似文献
8.
9.
A method was developed to determine simazine, atrazine and their metabolite, 2-chloro-4,6-diamino-1,3,5-triazine, in urine. The presence of these herbicides in urine may reflect possible exposure to pesticides. Sample preparation involved protein precipitation and solid-phase extraction. The samples were analyzed by high-performance liquid chromatography-mass spectrometry. The detection limits were 0.4 microg/l and the analytes have a linear response in the interval 6-800 microg/l. The precision of the method was reflected in the RSD of < 2.4% for the herbicides studied. Based on the detectable herbicide levels from spiked urine samples collected from unexposed volunteers, this method can be used to determine the low levels necessary for establishing reference values of the selected herbicides and the metabolite. 相似文献
10.
11.
超高效液相色谱-电喷雾电离串联质谱联用法检测茶叶中阿维菌素类药物残留 总被引:10,自引:0,他引:10
建立了采用超高效液相色谱-电喷雾电离串联质谱同时检测茶叶中爱比菌素、甲胺基阿维菌素、乙酰胺基阿维菌素、伊维菌素、多拉菌素、莫西丁克残留的方法。试样经饱和氯化钠溶液浸润后,用乙腈提取,C18固相萃取小柱净化,超高效液相色谱-电喷雾串联质谱法(UPLC/ESI-MS/MS)测定。对流动相、监测离子、校正曲线等进行了优化和探讨。6种分析物在2.0~50 μg/L范围内线性关系良好,相关系数均大于0.9920。莫西丁克在5,10,20 μg/kg,其余分析物在2,5,10 μg/kg加标水平的平均回收率为61.7%~85.4%,相对标准偏差为9.37%~17.19%。该方法可靠、稳定,可满足茶叶中阿维菌素类药物残留检测与确证的需要。 相似文献
12.
Rapid quantification of lisinopril in human plasma by liquid chromatography/tandem mass spectrometry
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers. 相似文献
13.
建立了测定植物中痕量脱落酸 (ABA) 的液相色谱-电喷雾串联质谱联用分析方法. 植物提取液先采用固相萃取 (SPE) 富集脱落酸并消除基体干扰, 然后以C18柱为固定相, V(甲醇)∶V(2 g/L甲酸水溶液)=50∶50为流动相分离脱落酸. 电喷雾(ESI)串联质谱采用负离子模式. 选择反应监测 (SRM) 模式用于脱落酸定量, 选择的离子对是263→153, 219. 脱落酸的线性范围为0.005~10 μg/mL, 检测限 (S/N=3) 为0.003 μg/mL, 加标0.02 μg和0.05 μg的回收率分别为98.3% 和103.5%. 该方法用于冬青芽中脱落酸的分析, 结果表明所建立的SPE-LC-MS/MS方法对于分析植物中的痕量脱落酸是有效的. 相似文献
14.
建立了固相萃取-超高效液相色谱-电喷雾串联质谱(SPE-UPLC-ESI MS/MS)联用方法,定量测定尿样中的麻黄碱和N-甲基麻黄碱。样品经Oasis MCX柱提取、纯化和富集后,采用电喷雾(ESI)离子源电离,正离子多反应监测(MRM)模式质谱进行定性和定量分析。麻黄碱和N-甲基麻黄碱在0.0250~2.50 μg/L质量浓度范围内线性关系良好,线性相关系数分别为0.9998和0.9992,提取回收率高于80%,提取效率的RSD小于5.0%,检出限均达到0.01 μg/L,可大大延长尿样检材中麻黄碱和N-甲基麻黄碱的检测周期。结果表明,该方法快速、准确,为尿液中痕量麻黄碱和N-甲基麻黄碱的分析提供了灵敏的分析方法。 相似文献
15.
Determination of hexabromocyclododecane diastereoisomers in air and soil by liquid chromatography-electrospray tandem mass spectrometry 总被引:2,自引:0,他引:2
Hexabromocyclododecanes (HBCDs), used as additive brominated flame retardants, are of high concern due to their widespread use and increasing levels in various environmental systems. High-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-MS/MS) was developed for the determination of HBCD diastereoisomers. A detailed study was carried out to optimize the composition of the mobile phase involving methanol/acetonitrile/water, and the values of MS/MS parameters. It was found that the mobile phase could simultaneously affect the chromatographic separation and sensitivity. The instrumental limits of detection (LODs) on column in this study were 0.5, 0.3 and 0.3 pg for alpha-HBCD, beta-HBCD and gamma-HBCD, respectively. The effects of extracted matrix components on HBCD determination were investigated by spiking air and soil sample extracts with three 13C-labelled individual stereoisomers. The results indicated that the responses of the HBCD analysis in air and soils were not significantly affected by matrix effects. The method reported here was further applied to the air and soil samples. Three HBCD diastereoisomers were detected in all the air and soil samples, with levels ranging from 1.2 to 1.8 pg/m3 and 1.7 to 5.6 ng/g dry weight, respectively. 相似文献
16.
A method has been developed and optimised for the determination of two natural estrogens, estrone (E1) and 17beta-estradiol (E2), and one synthetic estrogen, 17alpha-ethynylestradiol (EE2), in river sediments at the sub-ng/g level. This procedure includes microwave-assisted solvent extraction (MASE), solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionisation. Using sediments spiked with the three estrogens at 10 ng/g wet weight, efficient extraction (>92%) of all the three analytes was achieved by MASE, and whole-procedure recoveries ranged from 82 to 98%. Optimisation of the LC separation allowed for substantial reduction of ionisation suppression in the electrospray source to a final level of <18% suppression. Time-of-flight mass spectrometry (TOF-MS) and MS/MS were compared for the analysis of sediment extracts, with the latter technique proving to be the most selective. The method detection limits achieved by LC-MS/MS were 15, 30 and 40 pg/g for E1, E2 and EE2, respectively, which were 13-fold lower than those obtained by LC-TOF-MS. Analysis of river sediments collected from the River Ouse, UK, showed the presence of the natural estrogens at sub-ng/g level. E1 levels ranged from 0.40 ng/g (dry weight) to 3.30 ng/g while E2 levels ranged from <0.03 to 1.20 ng/g and EE2 was never detected (<0.04 ng/g). 相似文献
17.
E. N. Semenistaya N. B. Savel’eva T. G. Sobolevskii G. M. Rodchenkov 《Journal of Analytical Chemistry》2013,68(2):173-182
A method is proposed for the detection and confirmation of the presence of beta-blockers and their metabolites in fivefold diluted human urine samples by ultra performance liquid chromatography coupled with electrospay ionization tandem mass spectrometry. The limits of detection for most of compounds are 5–10 ng/mL. A substantial effect of ionization suppression was observed. The determination of metabolites and glucuronides of beta-blockers without additional derivatization and extraction is described for the first time. 相似文献
18.
Rashed MS Saadallah AA Rahbeeni Z Eyaid W Seidahmed MZ Al-Shahwan S Salih MA Osman ME Al-Amoudi M Al-Ahaidib L Jacob M 《Biomedical chromatography : BMC》2005,19(3):223-230
Molybdenum cofactor and isolated sulphite oxidase deficiencies are two related rare autosomal recessive diseases characterized by severe neurological abnormalities, dislocated lens and mental retardation. Determination of three biochemical markers S-sulphocysteine (SSC), xanthine (XAN) and hypoxanthine (HXAN) in urine is essential for a definitive diagnosis and identification of the exact defect. We developed a rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of SSC, XAN and HXAN in urine. The analysis was carried out in the negative-ion selected-reaction monitoring mode. The turnaround time for the assay was 7 min. Linear calibration curves for the three biomarkers were obtained in the range of 12-480 micromol/L. The intra- and inter-day assay variations were <2.5%. Mean recoveries of SSC, XAN and HXAN added to urine at two significantly different concentrations were in the range 94.3-107.3%. At a normal SSC urine excretion value of 3.2 micromol/mmol creatinine, the signal-to-noise ratio was 337:1. This stable isotope dilution LC-MS/MS method is specific, rapid and simple, and provides definitive diagnosis for molybdenum cofactor and isolated sulphite oxidase deficiencies in very small volumes of urine. We have identified seven new cases of isolated sulphite oxidase deficiency from four Saudi families and one Sudanese family. 相似文献
19.
Determination of abamectin and azadirachtin residues in orange samples by liquid chromatography-electrospray tandem mass spectrometry 总被引:2,自引:0,他引:2
A rapid and sensitive LC-ESI-MS-MS method has been developed for the determination of azadirachtin and abamectin residues in orange samples. Samples were extracted with acetonitrile, in a high-speed blender. After the addition of sodium acetate, an aliquot of extract was directly injected into the LC-ESI-MS-MS system. The highest sensitivity of the method was achieved under MS-MS conditions using [M+Na]+ adducts as precursor ions. Recoveries for both compoundsfrom spiked orange samples at 0.01 and 0.1 mg/kg were above 80%, with good repeatability (<10%). Method detection limits achieved (<0.007 mg/kg) were adequate for the determination of these pesticides in this kind of sample from the regulatory point of view. The importance of the solvent used for extraction, as well as the addition of sodium acetate to the extracts and the selection of adequate chromatographic conditions are discussed. 相似文献
20.
液相色谱-电喷雾串联质谱法检测鸡组织中5种聚醚类药物残留 总被引:2,自引:0,他引:2
建立了鸡组织中聚醚类药物多残留检测的高效液相色谱-电喷雾串联质谱方法。采用甲醇提取鸡组织中的拉沙洛菌素、盐霉素、莫能菌素、甲基盐霉素和马杜霉素,经硅胶柱净化,以乙腈(含0.1%甲酸)-0.1%甲酸水溶液(体积比为97:3)为流动相,Symmetry Shield RP18作为色谱分析柱,多反应监测(MRM)正离子扫描方式进行质谱检测。当5种聚醚类药物的添加水平为鸡肉0.1~1500 μg/kg、鸡肝0.2~4500 μg/kg时,平均回收率为71.6%~99.1%,日内测定的相对标准偏差(RSD)(n=5)为3.2%~10.7%,日间RSD(n=3)为4.6%~14.7%。2种鸡组织中5种聚醚类药物的定量限为0.1~1.0 μg/kg。该方法的灵敏度、准确度和精密度均符合兽药残留分析技术的要求,适用于鸡肉和鸡肝中5种聚醚类药物的多残留检测。 相似文献