1.
《Analytical letters》2012,45(16):2398-2411
In this paper, three different types of biodiesel, which were synthesized from peanut, corn, and canola oils, were characterized by positive-ion electrospray ionization (ESI) and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Different biodiesel/diesel blends containing 2–90% (V/V) of each biodiesel type were prepared and analyzed by near infrared spectroscopy (NIR). In the next step, the chemometric methods of hierarchical clusters analysis (HCA), principal component analysis (PCA), and support vector machines (SVM) were used for exploratory analysis of the different biodiesel samples, and the SVM was able to give the best classification results (correct classification of 50 peanut and 50 corn samples, and only one misclassification out of 49 canola samples). Then, partial least squares (PLS) and multivariate adaptive regression splines (MARS) models were evaluated for biodiesel quantification. Both methods were considered equivalent for quantification purposes based on the values smaller than 5% for the root mean square error of calibration (RMSEC) and root mean square of validation (RMSEP), as well as Pearson correlation coefficients of at least 0.969. The combination of NIR to the chemometric techniques of SVM and PLS/MARS was proven to be appropriate to classify and quantify biodiesel from different origins.  相似文献   

2.
This paper evaluates analytical methods based on near infrared (NIR) and middle infrared (MIR) spectroscopy and multivariate calibration to monitor the stability of biodiesel. There was a focus on three parameters: oxidative stability index, acid number and water content. Ethylic and methylic biodiesel from different feedstocks were used in experiments of accelerated aging, in order to take into account the wide variety of oilseeds and feedstocks available in Brazil. Partial least squares (PLS) and multiple linear regression (MLR) models were developed. Different pre-processing techniques and spectral variable/regions selection algorithms were evaluated. For MLR models, the successive projection algorithm (SPA) was employed. Interval PLS (iPLS) and selection of variables taking into account the significant regression coefficients were used for PLS models. Results showed that both near and middle infrared regions, and all variable selection methods tested were efficient for predicting these three important quality parameters of B100, the root mean squares error of prediction (RMSEP) values being comparable to the reproducibility of the corresponding standard method for each property investigated.  相似文献   

3.
Balabin RM  Lomakina EI 《The Analyst》2011,136(8):1703-1712
In this study, we make a general comparison of the accuracy and robustness of five multivariate calibration models: partial least squares (PLS) regression or projection to latent structures, polynomial partial least squares (Poly-PLS) regression, artificial neural networks (ANNs), and two novel techniques based on support vector machines (SVMs) for multivariate data analysis: support vector regression (SVR) and least-squares support vector machines (LS-SVMs). The comparison is based on fourteen (14) different datasets: seven sets of gasoline data (density, benzene content, and fractional composition/boiling points), two sets of ethanol gasoline fuel data (density and ethanol content), one set of diesel fuel data (total sulfur content), three sets of petroleum (crude oil) macromolecules data (weight percentages of asphaltenes, resins, and paraffins), and one set of petroleum resins data (resins content). Vibrational (near-infrared, NIR) spectroscopic data are used to predict the properties and quality coefficients of gasoline, biofuel/biodiesel, diesel fuel, and other samples of interest. The four systems presented here range greatly in composition, properties, strength of intermolecular interactions (e.g., van der Waals forces, H-bonds), colloid structure, and phase behavior. Due to the high diversity of chemical systems studied, general conclusions about SVM regression methods can be made. We try to answer the following question: to what extent can SVM-based techniques replace ANN-based approaches in real-world (industrial/scientific) applications? The results show that both SVR and LS-SVM methods are comparable to ANNs in accuracy. Due to the much higher robustness of the former, the SVM-based approaches are recommended for practical (industrial) application. This has been shown to be especially true for complicated, highly nonlinear objects.  相似文献   

4.
Near-infrared (NIR) spectroscopy, in combination with chemometrics, enable the analysis of raw materials without time-consuming sample preparation methods. The aim of our work was to estimate critical parameters in the analytical specification of oxytetracycline, and consequently the development of a method for quantification and qualification of these parameters by NIR spectroscopy. A Karl Fischer (K.F.) titration to determine the water content, a colorimetric assay method, and Fourier transform-infrared (FT-IR) spectroscopy to identify the oxytetracycline base, were used as reference methods, respectively. Multivariate calibration was performed on NIR spectral data using principal component analysis (PCA), partial least-squares (PLS 1) and principal component regression (PCR) chemometric methods. Multivariate calibration models for NIR spectroscopy have been developed. Using PCA and the Soft Independent Modelling of Class Analogy (SIMCA) approach, we established the cluster model for the determination of sample identity. PLS 1 and PCR regression methods were applied to develop the calibration models for the determination of water content and the assay of the oxytetracycline base. Comparing the PLS and PCR regression methods we found out that the PLS is better established by NIR, especially as the spectroscopic data (NIR spectra) are highly collinear and there are many wavelengths due to non-selective wavelengths. The calibration models for NIR spectroscopy are convenient alternatives to the colorimetric method and to the K.F. method, as well as to FT-IR spectroscopy, in the routine control of incoming material.  相似文献   

5.
Near-infrared (NIR) spectra in the region of 5000-4000 cm−1 with a chemometric method called searching combination moving window partial least squares (SCMWPLS) were employed to determine the concentrations of human serum albumin (HSA), γ-globulin, and glucose contained in the control serum IIB (CS IIB) solutions with various concentrations. SCMWPLS is proposed to search for the optimized combinations of informative regions, which are spectral intervals, considered containing useful information for building partial least squares (PLS) models. The informative regions can easily be found by moving window partial least squares regression (MWPLSR) method. PLS calibration models using the regions obtained by SCMWPLS were developed for HSA, γ-globulin, and glucose. These models showed good prediction with the smallest root mean square error of predictions (RMSEP), the relatively small number of PLS factors, and the highest correlation coefficients among the results achieved by using whole region and MWPLSR methods. The RMSEP values of HSA, γ-globulin, and glucose yielded by SCMWPLS were 0.0303, 0.0327, and 0.0195 g/dl, respectively. These results prove that SCMWPLS can be successfully applied to determine simultaneously the concentrations of HSA, γ-globulin, and glucose in complicated biological fluids such as CS IIB solutions by using NIR spectroscopy.  相似文献   

6.
Different calibration techniques are available for spectroscopic applications that show nonlinear behavior. This comprehensive comparative study presents a comparison of different nonlinear calibration techniques: kernel PLS (KPLS), support vector machines (SVM), least-squares SVM (LS-SVM), relevance vector machines (RVM), Gaussian process regression (GPR), artificial neural network (ANN), and Bayesian ANN (BANN). In this comparison, partial least squares (PLS) regression is used as a linear benchmark, while the relationship of the methods is considered in terms of traditional calibration by ridge regression (RR). The performance of the different methods is demonstrated by their practical applications using three real-life near infrared (NIR) data sets. Different aspects of the various approaches including computational time, model interpretability, potential over-fitting using the non-linear models on linear problems, robustness to small or medium sample sets, and robustness to pre-processing, are discussed. The results suggest that GPR and BANN are powerful and promising methods for handling linear as well as nonlinear systems, even when the data sets are moderately small. The LS-SVM is also attractive due to its good predictive performance for both linear and nonlinear calibrations.  相似文献   

7.
《Analytica chimica acta》2004,509(2):217-227
In near-infrared (NIR) measurements, some physical features of the sample can be responsible for effects like light scattering, which lead to systematic variations unrelated to the studied responses. These errors can disturb the robustness and reliability of multivariate calibration models. Several mathematical treatments are usually applied to remove systematic noise in data, being the most common derivation, standard normal variate (SNV) and multiplicative scatter correction (MSC). New mathematical treatments, such as orthogonal signal correction (OSC) and direct orthogonal signal correction (DOSC), have been developed to minimize the variability unrelated to the response in spectral data. In this work, these two new pre-processing methods were applied to a set of roasted coffee NIR spectra. A separate calibration model was developed to quantify the ash content and lipids in roasted coffee samples by PLS regression. The results provided by these correction methods were compared to those obtained with the original data and the data corrected by derivation, SNV and MSC. For both responses, OSC and DOSC treatments gave PLS calibration models with improved prediction abilities (4.9 and 3.3% RMSEP with corrected data versus 7.1 and 8.3% RMSEP with original data, respectively).  相似文献   

8.
Quantitative structure-activity relationship (QSAR) studies based on chemometric techniques are reviewed. Partial least squares (PLS) is introduced as a novel robust method to replace classical methods such as multiple linear regression (MLR). Advantages of PLS compared to MLR are illustrated with typical applications. Genetic algorithm (GA) is a novel optimization technique which can be used as a search engine in variable selection. A novel hybrid approach comprising GA and PLS for variable selection developed in our group (GAPLS) is described. The more advanced method for comparative molecular field analysis (CoMFA) modeling called GA-based region selection (GARGS) is described as well. Applications of GAPLS and GARGS to QSAR and 3D-QSAR problems are shown with some representative examples. GA can be hybridized with nonlinear modeling methods such as artificial neural networks (ANN) for providing useful tools in chemometric and QSAR.  相似文献   

9.
Abstract

Quantitative structure-activity relationship (QSAR) studies based on chemometric techniques are reviewed. Partial least squares (PLS) is introduced as a novel robust method to replace classical methods such as multiple linear regression (MLR). Advantages of PLS compared to MLR are illustrated with typical applications. Genetic algorithm (GA) is a novel optimization technique which can be used as a search engine in variable selection. A novel hybrid approach comprising GA and PLS for variable selection developed in our group (GAPLS) is described. The more advanced method for comparative molecular field analysis (CoMFA) modeling called GA-based region selection (GARGS) is described as well. Applications of GAPLS and GARGS to QSAR and 3D-QSAR problems are shown with some representative examples. GA can be hybridized with nonlinear modeling methods such as artificial neural networks (ANN) for providing useful tools in chemometric and QSAR.  相似文献   

10.
Adulteration of foods has been known to exist for a long time and various analytical tests have been reported to address this problem. Among them, authenticity of sesame oil has attracted much attention. Near-infrared (NIR) spectral quantitative detection models of sesame oil adulterated with other oils are constructed by chemometric methods, i.e., competitive adaptive reweighted sampling (CARS), elastic component regression (ECR) and partial least squares (PLS). Sixty samples adulterated with different proportions of five kinds of other oils of lower price were scanned by a Fourier-transform-NIR spectrometer and the NIR spectra were collected in 4500–10000 cm−1 region by transmission mode. All samples were divided into the training set and an independent test set. Model population analysis has also been carried out and confirms the importance of selecting representative samples. The experimental results indicate that the PLS model using only 10 variables from CARS and the ECR model show similar performance and both are superior to the full-spectrum PLS model. CARS focuses on selecting variables and ECR focuses on optimizing the parameters, implying that both roads lead to the same destination. It seems that NIR technique combined with CARS or ECR is feasible for rapidly detecting sesame oil adulterated with other vegetable oils.  相似文献   

11.
在pH1.81的Britton-Robinson(B-R)缓冲溶液中对诺氟沙星、氧氟沙星和洛美沙星三组分混合溶液进行光度测定,所得的重叠光谱数据用经典最小二乘(CLS),主成分回归(PCR),偏最小二乘(PLS)和径向基人工神经网络(RBF-ANN)方法处理和分析,结果表明RBF-ANN对合成样中三种药物浓度的预报结果...  相似文献   

12.
We present four unique prediction techniques, combined with multiple data pre-processing methods, utilizing a wide range of both oil types and oil peroxide values (PV) as well as incorporating natural aging for peroxide creation. Samples were PV assayed using a standard starch titration method, AOCS Method Cd 8-53, and used as a verified reference method for PV determination. Near-infrared (NIR) spectra were collected from each sample in two unique optical pathlengths (OPLs), 2 and 24 mm, then fused into a third distinct set. All three sets were used in partial least squares (PLS) regression, ridge regression, LASSO regression, and elastic net regression model calculation. While no individual regression model was established as the best, global models for each regression type and pre-processing method show good agreement between all regression types when performed in their optimal scenarios. Furthermore, small spectral window size boxcar averaging shows prediction accuracy improvements for edible oil PVs. Best-performing models for each regression type are: PLS regression, 25 point boxcar window fused OPL spectral information RMSEP = 2.50; ridge regression, 5 point boxcar window, 24 mm OPL, RMSEP = 2.20; LASSO raw spectral information, 24 mm OPL, RMSEP = 1.80; and elastic net, 10 point boxcar window, 24 mm OPL, RMSEP = 1.91. The results show promising advancements in the development of a full global model for PV determination of edible oils.  相似文献   

13.
This work evaluates the use of near-infrared (NIR) overtone regions to determine biodiesel content, as well potential adulteration with vegetable oil, in diesel/biodiesel blends. For this purpose, NIR spectra (12,000–6300 cm−1) were obtained using three different optical path lengths: 10 mm, 20 mm and 50 mm. Two strategies of regression with variable selection were evaluated: partial least squares (PLS) with significant regression coefficients selected by Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with wavenumber selection by successive projections algorithm (MLR/SPA). For comparison, the results obtained by using PLS full-spectrum models are also presented. In addition, the performance of models using NIR (1.0 mm optical path length, 9000–4000 cm−1) and MIR (UATR – universal attenuated total reflectance, 4000–650 cm−1) spectral regions was also investigated. The results demonstrated the potential of overtone regions with MLR/SPA regression strategy to determine biodiesel content in diesel/biodiesel blends, considering the possible presence of raw oil as a contaminant. This strategy is simple, fast and uses a fewer number of spectral variables. Considering this, the overtone regions can be useful to develop low cost instruments for quality control of diesel/biodiesel blends, considering the lower cost of optical components for this spectral region.  相似文献   

14.
The transesterification of vegetable oils, animal fats or waste oils with an alcohol (such as methanol) in the presence of a homogeneous catalyst (sodium hydroxide or methoxyde) is commonly used to produce biodiesel. The quality control of the final product is an important issue and near infrared (NIR) spectroscopy recently appears as an appealing alternative to the conventional analytical methods. The use of NIR spectroscopy for this purpose first involves the development of calibration models to relate the near infrared spectrum of biodiesel with the analytical data. The type of pre-processing technique applied to the data prior to the development of calibration may greatly influence the performance of the model. This work analyses the effect of some commonly used pre-processing techniques applied prior to partial least squares (PLS) and principal components regressions (PCR) in the quality of the calibration models developed to relate the near infrared spectrum of biodiesel and its content of methanol and water. The results confirm the importance of testing various pre-processing techniques. For the water content, the smaller validation and prediction errors were obtained by a combination of a second order Savitsky-Golay derivative followed by mean centring prior to PLS and PCR, whereas for methanol calibration the best results were obtained with a first order Savitsky-Golay derivative plus mean centring followed by the orthogonal signal correction.  相似文献   

15.
《Analytical letters》2012,45(4):687-700
In this study, simultaneous spectrophotometry determination of guaifenesin and theophylline in pharmaceuticals by chemometric approaches has been reported. Spectra of mixtures of these drugs were recorded and corresponding first derivatives were calculated. Partial least squares regression (PLS) alone and ant colony optimization (ACO) coupled with PLS were used in analysis of the data. Ant colony system (ACS) as an efficient ACO algorithm was used. In addition, ACS was combined to genetic algorithm (GA) to produce better results. The analytical performances of these chemometric methods were characterized by relative prediction errors. These methods were successfully applied to pharmaceutical formulation.  相似文献   

16.
A method for sulfur determination in diesel fuel employing near infrared spectroscopy, variable selection and multivariate calibration is described. The performances of principal component regression (PCR) and partial least square (PLS) chemometric methods were compared with those shown by multiple linear regression (MLR), performed after variable selection based on the genetic algorithm (GA) or the successive projection algorithm (SPA). Ninety seven diesel samples were divided into three sets (41 for calibration, 30 for internal validation and 26 for external validation), each of them covering the full range of sulfur concentrations (from 0.07 to 0.33% w/w). Transflectance measurements were performed from 850 to 1800 nm. Although principal component analysis identified the presence of three groups, PLS, PCR and MLR provided models whose predicting capabilities were independent of the diesel type. Calibration with PLS and PCR employing all the 454 wavelengths provided root mean square errors of prediction (RMSEP) of 0.036% and 0.043% for the validation set, respectively. The use of GA and SPA for variable selection provided calibration models based on 19 and 9 wavelengths, with a RMSEP of 0.031% (PLS-GA), 0.022% (MLR-SPA) and 0.034% (MLR-GA). As the ASTM 4294 method allows a reproducibility of 0.05%, it can be concluded that a method based on NIR spectroscopy and multivariate calibration can be employed for the determination of sulfur in diesel fuels. Furthermore, the selection of variables can provide more robust calibration models and SPA provided more parsimonious models than GA.  相似文献   

17.
In this study, the simultaneous determination of paracetamol, ibuprofen and caffeine in pharmaceuticals by chemometric approaches using UV spectrophotometry has been reported as a simple alternative to using separate models for each component. Spectra of paracetamol, ibuprofen and caffeine were recorded at several concentrations within their linear ranges and were used to compute the calibration mixture between wavelengths 200 and 400 nm at an interval of 1 nm in methanol:0.1 HCl (3:1). Partial least squares regression (PLS), genetic algorithm coupled with PLS (GA-PLS), and principal component-artificial neural network (PC-ANN) were used for chemometric analysis of data and the parameters of the chemometric procedures were optimized. The analytical performances of these chemometric methods were characterized by relative prediction errors and recoveries (%) and were compared with each other. The GA-PLS shows superiority over other applied multivariate methods due to the wavelength selection in PLS calibration using a genetic algorithm without loss of prediction capacity. Although the components show an important degree of spectral overlap, they have been determined simultaneously and rapidly requiring no separation step. These three methods were successfully applied to pharmaceutical formulation, capsule, with no interference from excipients as indicated by the recovery study results. The proposed methods are simple and rapid and can be easily used in the quality control of drugs as alternative analysis tools.  相似文献   

18.
Determination of edible oil parameters by near infrared spectrometry   总被引:6,自引:0,他引:6  
A chemometric method has been developed for the determination of acidity and peroxide index in edible oils of different types and origins by using near infrared spectroscopy (NIR) measurements. Different methods for selecting the calibration set, after an hierarchical cluster analysis, were applied. After discrimination of olive oils from maize, seed and sunflower, the prediction capabilities of partial least squares (PLS) multivariate calibration of NIR data were evaluated. Several preprocessing alternatives (first derivative, multiplicative scatter correction, vector normalization, constant offset elimination, mean centering and standard normal variate) were investigated by using the root mean square error of validation (RMSEV) and prediction (RMSEP), as control parameters. Under the best conditions studied, the validation set provides RMSEP values of 0.034 and 0.037% (w/w) for acidity in (I) olive oil group and (II) sunflower, seed and maize oils group. RMSEP values for peroxide in both sample groups, expressed as mequiv. O2 kg−1, were, respectively 1.87 and 0.79. The limit of detection of the methodology developed was 0.03% for acidity in both groups of edible oils (I and II), and 0.9 and 0.8 mequiv. O2 kg−1 for peroxide in the olive oil and other edible oils groups, respectively. In fact, the methodology developed is proposed for direct acidity quantification and for the screening of peroxide index in edible oils, requiring less than 30 s per sample without any previous treatment.  相似文献   

19.
《Analytical letters》2012,45(9):2073-2083
Abstract

A consensus regression approach based on partial least square (PLS) regression, named as cPLS, for calibrating the NIR data was investigated. In this approach, multiple independent PLS models were developed and integrated into a single consensus model. The utility and merits of the cPLS method were demonstrated by comparing its results with those from a regular PLS method in predicting moisture, oil, protein, and starch contents of corn samples using the NIR spectral data. It was found that cPLS was superior to regular PLS with respect to prediction accuracy and robustness.  相似文献   

20.
Sanz MB  Sarabia LA  Herrero A  Ortiz MC 《Talanta》2002,56(6):1039-1048
A procedure to evaluate the robustness of an analytical method when there are changes in some experimental variables, when using multivariate calibration, is proposed. The procedure consists of analysing the root mean square error of prediction (RMSEP) as a response to a Plackett–Burman experimental design, through which the influence of several experimental factors on the prediction capability of the multivariate partial least squares (PLS) models built is studied. Two different ways of analysing the experimental design response are considered: establishing the residual variance with replicates and using Lenth's method. The proposed methodology has been applied to estimate the robustness of the polarographic determination of benzaldehyde when PLS calibration is used.  相似文献   