首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
影响条纹图形拼接法测量精度的主要误差因素   总被引:1,自引:1,他引:0  
吴德柱  陈明仪 《光学学报》1998,18(11):576-1581
通过对计算机模拟和实验结果的分析表明,影响条纹图形拼接法测量精度的主要因素是子孔径面形测量精度,重叠区的大小,面形拟合阶次和拼接模式等。  相似文献   

2.
We examine the sources of error in the histogram reweighting method for Monte Carlo data analysis. We demonstrate that, in addition to the standard statistical error which has been studied elsewhere, there are two other sources of error, one arising through correlations in the reweighted samples, and one arising from the finite range of energies sampled by a simulation of finite length. We demonstrate that while the former correction is usually negligible by comparison with statistical fluctuations, the latter may not be, and give criteria for judging the range of validity of histogram extrapolations based on the size of this latter correction.  相似文献   

3.
Whole-space tabulation method (WSTM) is a technique to relate the phase of a projected grating and the coordinates at each pixel of a camera. The relation data of all the pixels are obtained in the whole-space where a reference plane is moved. The relation data are stored in tables. Thereby, WSTM is high speed and accurate shape measurement method because the coordinates are obtained by only looking up the tables without any complex calculation. Even when the brightness distribution of the projected grating is warped from a cosinusoidal wave, correct coordinates are provided. However, the WSTM needs huge memories for the phase-coordinate tables such as 10 GB in the case of a VGA image and 2000 tables at each pixel. Therefore, we developed an FPGA memory board to store the table and to refer the table in real-time. In the case of a ball grid array (BGA), it is necessary to measure the shape of the balls with high accuracy and high speed without the influence of halation. It is also necessary to measure the coplanarity of the balls without distortion. The influence of halation can be reduced with combining the 3D shape measured with several cameras set at different positions. It is easy to realize them using the WSTM. In this paper, it is confirmed that accurate shape measurements for a BGA can be performed using the WSTM with an FPGA memory board.  相似文献   

4.
相干多普勒测风激光雷达通常会采用周期图最大值法(PM)提取不同距离门信号的多普勒频移(对应风速)信息。由于噪声和相干效率的影响,个别距离门信号会出现信噪比(SNR)突然降低的情况,从而导致系统的探测概率降低,影响系统整体的探测性能。为了解决个别距离门信号多普勒频移的错误估计问题,提出了一种新的非线性自适应多普勒频移估计方法。该方法利用风速的连续性,标定错误距离门,并自适应地利用强信噪比区域的多普勒频移统计数据来弥补信噪比变差而出现的估计错误。分别利用了仿真模型和一套1.54μm全光纤相干激光雷达系统获得了风场测量数据,对比了使用该技术前后反演得到的风速趋势,证明该方法能够有效地解决上述问题。  相似文献   

5.
用微透镜阵列在单模光纤中写入长周期光纤光栅的新方法   总被引:2,自引:0,他引:2  
Tam.  HY 杜卫冲 《光学学报》1998,18(11):599-1600
报道了用微透镜阵列、几百个准分子激光脉冲有效地写入长周期光纤光栅的新方法。  相似文献   

6.
阵列相关系数比对法在中药鉴别中的应用研究   总被引:2,自引:0,他引:2  
中药材红外光谱具有“指纹”性,通过对红外特征吸收谱图的比对可达到区分和鉴别药材的目的。该研究用Visual Basic 6.0设计了中药材红外光谱阵列相关系数比对软件,建立了300多种中药药材的红外光谱数据库,将未知药材的红外光谱与数据库中药材的红外光谱进行比对,它能依11个波段两光谱相关系数的大小自动找到与库中最相似的光谱的药材,从而达到鉴别未知药材的目的。研究结果表明:在光谱数据库所包含的药材范围内,指定阵列相关系数的阈值,抓住特征波段光谱的比对,可避开CO2和H2O等外界因素对谱图的干扰,使比对结果准确可靠。该法有望成为中药材快速鉴别的一种常规手段。  相似文献   

7.
The problem of computing light scattering by cylindrical fibers with high aspect ratio in the framework of the Null‐Field method with discrete sources is treated. Numerical experiments for investigating the scattering properties of two fiber geometries are performed using distributed spherical vector wave functions as discrete sources.  相似文献   

8.
利用激光诱导击穿光谱结合标准加入法定量分析了铅蓄电池厂含铅污泥中重金属铅元素含量, 标准加入法有效避免了外标法与内标法制作标准曲线时基质不同对LIBS检测结果的影响, 且样品处理过程简单。实验采用中心波长为1 064 nm的Nd∶YAG脉冲激光器作为激发光源, 以高分辨率、宽光谱段的中阶梯光栅光谱仪和增强型电荷耦合器件为谱线分离与探测器件, 选取铅的PbⅠ: 405.78 nm特征谱线作为分析线, 以FeⅠ: 404.58 nm特征谱线作为内标线进行结果计算。预实验确定较佳的实验条件后(激光脉冲能量: 128.5 mJ, 延时: 2.5 μs, 门宽: 3 μs), 对铅蓄电池厂的未知铅泥样品中铅元素进行定量分析, 结果表明加入铅在0~25 000 mg·kg-1范围内谱线不会产生自吸收, PbⅠ: 405.78 nm信号强度与铅加入量呈很好的线性关系, 由此确定合适的铅加入量为0~25 000 mg·kg-1。在此基础上配制四个样品, 基质均为铅蓄电池厂含铅污泥, 加入铅浓度分别为5 000, 10 000, 15 000, 20 000 mg·kg-1, 每个样品设置三个平行样, 验证实验重复性及可靠性, 并与ICP-MS检测结果对比, 结果直线外推误差为-14.8%。12个样品单次计算结果误差介于为-24.6%~17.6%之间, 含铅量平均值为43 069 mg·kg-1, 相对误差为-2.44%。  相似文献   

9.
利用激光诱导击穿光谱结合标准加入法定量分析了铅蓄电池厂含铅污泥中重金属铅元素含量,标准加入法有效避免了外标法与内标法制作标准曲线时基质不同对LIBS检测结果的影响,且样品处理过程简单。实验采用中心波长为1 064 nm的Nd∶YAG脉冲激光器作为激发光源,以高分辨率、宽光谱段的中阶梯光栅光谱仪和增强型电荷耦合器件为谱线分离与探测器件,选取铅的PbⅠ:405.78 nm特征谱线作为分析线,以FeⅠ:404.58 nm特征谱线作为内标线进行结果计算。预实验确定较佳的实验条件后(激光脉冲能量:128.5 mJ,延时:2.5 μs,门宽:3 μs),对铅蓄电池厂的未知铅泥样品中铅元素进行定量分析,结果表明加入铅在0~25 000 mg·kg-1范围内谱线不会产生自吸收,PbⅠ:405.78 nm信号强度与铅加入量呈很好的线性关系,由此确定合适的铅加入量为0~25 000 mg·kg-1。在此基础上配制四个样品,基质均为铅蓄电池厂含铅污泥,加入铅浓度分别为5 000,10 000,15 000,20 000 mg·kg-1,每个样品设置三个平行样,验证实验重复性及可靠性,并与ICP-MS检测结果对比,结果直线外推误差为-14.8%。12个样品单次计算结果误差介于为-24.6%~17.6%之间,含铅量平均值为43 069 mg·kg-1,相对误差为-2.44%。  相似文献   

10.
Software estimation involves meeting a huge number of different requirements, such as resource allocation, cost estimation, effort estimation, time estimation, and the changing demands of software product customers. Numerous estimation models try to solve these problems. In our experiment, a clustering method of input values to mitigate the heterogeneous nature of selected projects was used. Additionally, homogeneity of the data was achieved with the fuzzification method, and we proposed two different activation functions inside a hidden layer, during the construction of artificial neural networks (ANNs). In this research, we present an experiment that uses two different architectures of ANNs, based on Taguchi’s orthogonal vector plans, to satisfy the set conditions, with additional methods and criteria for validation of the proposed model, in this approach. The aim of this paper is the comparative analysis of the obtained results of mean magnitude relative error (MMRE) values. At the same time, our goal is also to find a relatively simple architecture that minimizes the error value while covering a wide range of different software projects. For this purpose, six different datasets are divided into four chosen clusters. The obtained results show that the estimation of diverse projects by dividing them into clusters can contribute to an efficient, reliable, and accurate software product assessment. The contribution of this paper is in the discovered solution that enables the execution of a small number of iterations, which reduces the execution time and achieves the minimum error.  相似文献   

11.
Based on the shape invariance property we obtain exact solutions of the three-dimensional relativistic Klein Gordon equation for a charged particle moving in the presence of a certain varying magnetic field, and we also show its non-relativistic limit.  相似文献   

12.
The convective heat transfer coefficients resulting from a slot jet on a plane surface have been estimated by using the real measured temperatures in the plate and inverse method. In this study, the inverse method used the conjugate gradient method with an adjoint equation. Distributions of the local heat transfer coefficient on the impingement surface were determined for various Re and H/Dh. It was found the heat transfer coefficients generally tended to decrease with increasing separation distance and to increase with an increase in Reynolds number. This presented method is able to estimate the variation of the local Nusselt number with time.  相似文献   

13.
Based on the shape invariance property we obtain exact solutions oI the Dirac equation for an electron moving in the presence of a certain varying magnetic field, then we also show its non-relativistic limit.  相似文献   

14.
Unusual physical properties of an anisotropic liquid crystal (LC) medium, such as topological defects, elastic interaction with particles, and nonlinear electrophoresis, are ingeniously utilized to handle nanoparticles. Here, a new approach to manipulate quantum dots (QDs) using volume‐tunable and electrically movable isotropic pocket carriers in a nematic medium is demonstrated. This method is based on multiple mechanisms: spontaneous formation of QD flocs in LCs, sharp solubility contrast of QDs in nematic and isotropic phases, and biphasic dielectrophoresis in isotropic–nematic mixture. By thermally and electrically controlling the isotropic pockets containing QDs, an array of hierarchical QD clusters with the arbitrarily controllable size and location is fabricated. The phase boundary pressure squeezes the QD flocs to adhere to each other and on the substrate. The QD cluster array can be transferred to a flexible substrate, and can serve as a point light source array for display and image acquisition applications.  相似文献   

15.
Fluid-structure interaction (FSI) problems in microchannels play prominent roles in many engineering applications. The present study is an effort towards the simulation of flow in microchannel considering FSI. Top boundary of the microchannel is assumed to be rigid and the bottom boundary, which is modeled as a Bernoulli-Euler beam, is simulated by size-dependent beam elements for finite element method (FEM) based on a modified couple stress theory. The lattice Boltzmann method (LBM) using D2Q13 LB model is coupled to the FEM in order to solve fluid part of FSI problem. In the present study, the governing equations are non-dimensionalized and the set of dimensionless groups is exhibited to show their effects on micro-beam displacement. The numerical results show that the displacements of the micro-beam predicted by the size-dependent beam element are smaller than those by the classical beam element.  相似文献   

16.
In this paper, we develop a residual-based a posteriori error estimator for the time-dependent Maxwell's equations in the cold plasma. Here we consider a semi-discrete interior penalty discontinuous Galerkin (DG) method for solving the governing equations. We provide both the upper bound and lower bound analysis for the error estimator. This is the first posteriori error analysis carried out for the Maxwell's equations in dispersive media.  相似文献   

17.
Wide range of rotating machinery contains an inherent amount of unbalance which leads to increase in the vibration level and related faults. In this work, the effect of different operating conditions viz. the unbalanced weight, radius, speed and position of the rotor disc on the unbalance in rotating machine are studied experimentally and analyzed by using Response Surface Methodology (RSM). RSM is a technique which consists of mathematical and statistical methods to develop the relationship between the inputs and outputs of a system by distinct functions. L27 Orthogonal Array (OA) was developed by using Design of Experiments (DOE) according to which experimentation has been carried out. Three accelerometer sensors were mounted to record the vibration responses (accelerations) in radially vertical, horizontal and axial directions. The responses recorded as root mean square values are then analysed using RSM. The relationship between response and operating factors has been established by developing a second order, non-linear mathematical model. Analysis of variance (ANOVA) has been performed for verification of the developed mathematical models. Results obtained from the analysis show that the unbalance weight and speed are most significant operating conditions that contribute the most to the effect the unbalance has on the rotating spindle.  相似文献   

18.
In this paper, a boundary condition-enforced IBM is introduced into the LBM in order to satisfy the non-slip and temperature boundary conditions, and natural convections in a concentric isothermal annulus between a square outer cylinder and a circular inner cylinder are simulated. The obtained results show that the boundary condition-enforced method gives a better solution for the flow field and the complicated physics of the natural convections in the selected case is correctly captured. The calculated average Nusselt numbers agree well with the previous studies.  相似文献   

19.
用蒙特卡罗方法计算棒状放大器内的泵浦能量分布   总被引:6,自引:3,他引:3  
张华  徐世祥 《光学学报》1997,17(12):601-1608
建立了用蒙特卡罗和光线跟踪法计算高功率固体激光系统棒状放大器能量沉积分布的模拟程序。在本文的模型中正确考虑了光线在反射器激光棒上的多次反射,氙灯的辐射光谱以及钕玻璃的吸收光谱。计算结果与作者用阈值法测量的增益均匀性以及用哈特曼网格法测量的氙灯泵浦对激光波面畸变的影响是一致的。  相似文献   

20.
利用课题组自主研制的便携式激光诱导击穿光谱测量系统定量分析土壤及固体废弃物中四种重金属元素Pb,Cd,Cr和Cu.实验采用中心波长为1064 nm的Nd:YAG脉冲激光器作为激发光源,工作频率为3 Hz,单脉冲能量为100 mJ,脉冲宽度为6 ns;以高分辨率、宽光谱段的中阶梯光栅光谱仪和增强型电荷耦合器件为谱线分离与探测器件,探测范围为200~500 nm,分辨率为0.08~0.12 nm.为了提高光谱强度及检测灵敏度,通过半球空间约束装置对等离子进行约束,并采用多芯光纤实现多通道不同角度光谱信号收集,接收角度为45°.实验时激光重复频率为2 Hz,延时为1.5μs,门宽为1.05 ms.文章创新性地将曲线拟合代替直线拟合用于标准加入法定量分析基质未知样品中重金属元素,有效提高了测量结果的准确性,尤其是低浓度的土壤样品,直线拟合无法定量分析重金属含量,相比而言,曲线拟合相关系数更高,测量结果更接近国标方法,可以满足一级土壤污染的检测.七个土壤及固体废弃物样品检测的相对误差如下,直线拟合相对误差分别为:Pb 1.26%~79.38%,Cr-22.44%~82.06%,Cu 15.09%~190.50%,Cd 32.76%~167.96%,曲线拟合相对误差为分别Pb-4.19%~11.92%,Cr-38.31%~9.26%,Cu-7.24%~26.86%,Cd-10.52%~12.94%,相对误差平均值为10.47%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号