首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Ethylmalonic acid is a metabolic organic acid, and its accumulation in urine is diagnostic of ethylmalonic aciduria. In this study, a simple and fast method employing capillary electrophoresis equipped with capacitively coupled contactless conductivity detection was developed for the detection of ethylmalonic acid in urine samples. The optimized electrophoretic separation was performed in 50 mmol/L 2‐(N‐morpholino)ethanesulfonic acid solution, buffered at a pH of 6.5, and contained 0.13 mmol/L cetyltrimethylammonium bromide as an electroosmotic modifier. Electrophoresis was run at 28 kV in reversed polarity. The linear range of ethylmalonic acid concentration was between 1 and 100 mg/L with a regression coefficient of 0.9998. This method had good intra‐ and interday precision with <5% relative standard deviations. The detection limit (signal‐to‐noise ratio = 3) and the quantification limit (signal‐to‐noise ratio = 10) values were 0.139 and 0.466 mg/L, respectively. Using our optimized conditions, the method was successfully employed for the detection of ethylmalonic acid in urine sample of ethylmalonic aciduria patient.  相似文献   

2.
Contactless conductivity detection is successfully demonstrated for the enantiomeric separation of basic drugs and amino acids in capillary electrophoresis (CE). Derivatization of the compounds or the addition of a visualization agent as for indirect optical detection schemes were not needed. Non-charged chiral selectors were employed, hydroxypropylated cyclodextrin (CD) for the more lipophilic basic drugs and 18-crown-6-tetracarboxylic acid (18C6H4) for the amino acids. Acidic buffer solutions based on lactic or citric acid were used. The detection limits were determined as 0.3 microM for pseudoephedrine as an example of a basic drug and were in the range from 2.5 to 20 microM for the amino acids.  相似文献   

3.
Antiseptic agent carbethopendecinium bromide (septonex) was determined by capillary electrophoresis with capacitively coupled contactless conductivity detection. Optimal separation of this quaternary ammonium ion was achieved in BGE of pH 7.0 containing 30 mM 2-(N-morpholino)ethanesulfonic acid, 12.5 mg/mL of 2-hydroxypropyl-β-cyclodextrin and 20% v/v of acetonitrile. The separation was performed at 25°C in an uncoated fused silica capillary (50 μm id; total length, 60.5 cm; effective length, 50 cm) at 30 kV. Samples were injected hydrodynamically at 50 mbar for 6 s. For quantitative analysis, L-arginine (500 μg/mL) was used as internal standard. The calibration curve was rectilinear for 25-400 μg/mL of septonex (y=0.0113x-0.0063; r(2)=0.9992). The LOD was 7 μg/mL of septonex (at S/N=3). The run-to-run repeatability (n=6) was characterized by the RSDs of 0.18% for the migration time and 1.96% for the analyte/internal standard peak area ratio. Accuracy tested by recovery experiments at three concentration levels gave recoveries of 100.27-104.22% with RSD ≤2.19%. The method was successfully applied to the assay of carbethopendecinium bromide in eye drops. Quaternary ammonium ions having structure and size close to that of carbethopendecinium may not be resolved from the analyte.  相似文献   

4.
Electromembrane extraction (EME) was used as an off-line sample pre-treatment method for the determination of heavy metal cations in aqueous samples using CE with capacitively coupled contactless conductivity detection (CE-C(4) D). A short segment of porous polypropylene hollow fibre was penetrated with 1-octanol and 0.5%?v/v bis(2-ethylhexyl)phosphonic acid and constituted a low cost, single use, disposable supported liquid membrane, which selectively transported and pre-concentrated heavy metal cations into the fibre lumen filled with 100?mM acetic acid acceptor solution. Donor solutions were standard solutions and real samples dissolved in deionized water at neutral pH. At optimized EME conditions (penetration time, 5?s; applied voltage, 75?V; and stirring rate, 750?rpm), 15-42% recoveries of heavy metal cations were achieved for a 5?min extraction time. Repeatability of the EME pre-treatment was examined for six independent EME runs and ranged from 6.6 to 11.1%. Limits of detection for the EME-CE-C(4) D method ranged from 25 to 200?nM, resulting into one to two orders of magnitude improvement compared with CE-C(4) D without sample treatment. The developed EME sample pre-treatment procedure was applied to the analysis of heavy metal cations in tap water and powdered milk samples. Zinc in the real samples was identified and quantified in a background electrolyte solution consisting of 20?mM L-histidine and 30?mM acetic acid at pH 4.95 in about 3?min.  相似文献   

5.
This paper describes the determination of ciclopirox olamine in pharmaceutical formulations using capillary electrophoresis with capacitively coupled contactless conductivity detection. In an alkaline medium, ciclopirox olamine is converted into an anionic species and its detection is possible in capillary electrophoresis with capacitively coupled contactless conductivity detection without an electroosmotic flow modifier, because it is a low-mobility species. A linear working range from 2.64 to 264 μg/mL in sodium hydroxide electrolyte as well as low detection limit (0.39 μg/mL) and a good repeatability (RSD = 3.4% for 264 μg/mL ciclopirox solution (n = 10)) were achieved. It was also possible to determine olamine in its cationic form when acetic acid was used as the electrolyte solution. The results obtained include a linear range from 26.4 to 184.8 μg/mL and a detection limit of 2.6 μg/mL olamine. The proposed methods were applied to the analysis of commercial pharmaceutical products and the results were compared with the values indicated by the manufacturer as well as those obtained using a titrimetric method recommended by American Pharmacopoeia.  相似文献   

6.
A simple, rapid method using CE and microchip electrophoresis with C4D has been developed for the separation of four nonsteroidal anti-inflammatory drugs (NSAIDs) in the environmental sample. The investigated compounds were ibuprofen (IB), ketoprofen (KET), acetylsalicylic acid (ASA), and diclofenac sodium (DIC). In the present study, we applied for the first time microchip electrophoresis with C4D detection to the separation and detection of ASA, IB, DIC, and KET in the wastewater matrix. Under optimum conditions, the four NSAIDs compounds could be well separated in less than 1 min in a BGE composed of 20 mM His/15 mM Tris, pH 8.6, 2 mM hydroxypropyl-beta-cyclodextrin, and 10% methanol (v/v) at a separation voltage of 1000–1200 V. The proposed method showed excellent repeatability, good sensitivity (LODs ranging between 0.156 and 0.6 mg/L), low cost, high sample throughputs, portable instrumentation for mobile deployment, and extremely lower reagent and sample consumption. The developed method was applied to the analysis of pharmaceuticals in wastewater samples with satisfactory recoveries ranging from 62.5% to 118%.  相似文献   

7.
The association of trimethoprim and sulfamethoxazole is a very effective with antibiotic properties, and commonly used in the treatment of a variety of infections. Due to the importance in diseases treatment of humans and also of animals, the development of methods for their quantification in commercial formulations is highly desirable. In the present study, a rapid method for simultaneous determination of these compounds using CE with capacitively coupled contactless conductivity detection was developed. A favorable working region for both analytes was from 12.5 to 200 μmol/L (linear responses with R > 0.999 for N = 5). Other parameters calculated were sensitivity (1.28 ± 0.10/1.45 ± 0.11) min/(μmol L), RSD (4.5%/2.0%), and LOD (1.1/3.3) μmol/L for trimethoprim and sulfamethoxazole, respectively. Under this condition, the total run time was only 2.6 min. The proposed method was applied to the determination of trimethoprim and sulfamethoxazole in commercial samples and the results were compared to those obtained by using a HPLC pharmacopoeia method. This new method is advantageous for quality‐control analyses of trimethoprim and sulfamethoxazole in pharmaceuticals samples, because it is rapid and precise. Moreover, it is less laborious and demands minimum amounts of reagents in comparison to the recommended method.  相似文献   

8.
A novel capillary electrophoretic method for the separation of pancuronium (PM) and vecuronium (VM) ions utilizing capacitively coupled contactless conductivity detection was devised and validated. The separation was carried out in bare fused-silica capillaries (50 μm id, 75/45 cm) at 25°C. Optimal BGE was 50 mM borate buffer of pH 9.5 containing 12.5 mg/mL of (2-hydoxypropyl)-γ-CD. The samples were injected hydrodynamically at 1000 mbar for 3 s. Separation was performed at +30 kV. Under such conditions the PM and VM were base-line resolved and the separation took < 4 min. For quantification phenyltrimethylammonium iodide was used as internal standard. Calibration curves were linear for both pancuronium bromide (PMB) and vecuronium bromide (VMB) in the range 25-250 μg/mL with r> 0.9968. The limits of detection were 7 and 6?μg/mL for PMB and VMB, respectively. The accuracy tested by recovery experiment at three concentration levels of added PMB and VMB was satisfactory (95.7-102.7%, n =3, with RSD < 2.61%). The method was successfully applied to the assay of PMB and VMB in commercial injection solutions.  相似文献   

9.
Electromembrane extraction (EME) and CE with capacitively coupled contactless conductivity detection (CE‐C4D) was applied to rapid and sensitive determination of perchlorate in drinking water and environmental samples. Porous polypropylene hollow fiber impregnated with 1‐heptanol acted as a supported liquid membrane (SLM) and perchlorate was transported and preconcentrated in the fiber lumen on application of electric field. High selectivity of perchlorate determination and its baseline separation from major inorganic anions was achieved in CE‐C4D using background electrolyte solution consisting of 7.5 mM L ‐histidine and 40 mM acetic acid at pH 4.1. The analytical method showed excellent parameters in terms of reproducibility; RSD values for migration times and peak areas at a spiked concentration of 15 μg/L of perchlorate (US EPA recommended limit for drinking water) were below 0.2 and 8.7%, respectively, in all examined water samples. Linear calibration curves were obtained for perchlorate in the concentration range 1–100 μg/L (r2≥0.999) with limits of detection at 1 μg/L for tap water and at 0.25–0.35 μg/L for environmental and bottled potable water samples. Recoveries at 15 μg/L of perchlorate were between 95.9 and 106.7% with minimum and maximum recovery values for snow and bottled potable water samples, respectively.  相似文献   

10.
A method for the determination of ethambutol (EMB), a first‐line drug against tuberculosis, based on CE with capacitively coupled contactless conductivity detection is proposed. The separation of EMB and its main product of degradation were achieved in less than 3 min with a resolution of 2.0 using a BGE composed of 50 mmol/L histidine and 30 mmol/L MES, pH 6.30. By raising the pH to 8.03, the analysis time was reduced to 1.0 min, but with a significant loss of resolution (0.7). Using the best separation conditions, linearity of 0.9976 (R2, five data points), sensitivity of 1.26×10?4 V min μmol?1 L, and LOD and quantification of 23.5 and 78.3 μmol/L, respectively, were obtained. Recoveries at four levels of concentration ranged from 95 to 102% and the concentration range studied ranged from 100 to 500 μmol/L. The results obtained for the determination of EMB in pharmaceutical formulations were compared with those obtained by using CE with photometric detection.  相似文献   

11.
Law WS  Kubán P  Zhao JH  Li SF  Hauser PC 《Electrophoresis》2005,26(24):4648-4655
The separation and detection of commonly used preservatives (benzoate, sorbate) and vitamin C by both conventional CE and microchip electrophoresis with capacitively coupled contactless conductivity detection is presented. The separation was optimized by adjusting the pH-value of the buffer and the use of hydroxypropyl-beta-CD (HP-beta-CD) and CTAB as additives. For conventional CE, optimal separation conditions were achieved in a histidine/tartrate buffer at pH 6.5, containing 0.025% HP-beta-CD and 0.1 mM CTAB. LOD ranged from 0.5 to 3 mg/L (S/N = 3) and the RSDs for migration time and peak area were less than 0.1 and 2%, respectively. A considerable reduction of analysis time can be accomplished by using microchip electrophoresis without significant loss in sensitivity under optimal separation conditions. A histidine/tartrate buffer at pH 6.5, incorporating 0.06% HP-beta-CD and 0.25 mM CTAB, gave detection limits ranging between 3 and 10 mg/L and satisfactory reproducibilities of < or =0.4% for the migration time and < or =3.5% for the peak area. The methods developed are useful for the quantitative determination of food additives in real samples such as soft drinks and vitamin C tablets.  相似文献   

12.
Electromembrane extraction (EME) proved to be a simple and rapid pretreatment method for analysis of amino acids and related compounds in body fluid samples. Body fluids were acidified to the final concentration of 2.5 M acetic acid and served as donor solutions. Amino acids, present as cations in the donor solutions, migrated through a supported liquid membrane (SLM) composed of 1-ethyl-2-nitrobenzene/bis-(2-ethylhexyl)phosphonic acid (85:15 (v/v)) into the lumen of a porous polypropylene hollow fiber (HF) on application of electric field. The HF was filled with 2.5 M acetic acid serving as the acceptor solution. Matrix components in body fluids were efficiently retained on the SLM and did not interfere with subsequent analysis. Capillary electrophoresis with capacitively coupled contactless conductivity detection was used for determination of 17 underivatized amino acids in background electrolyte solution consisting of 2.5 M acetic acid. Parameters of EME, such as composition of SLM, pH and composition of donor and acceptor solution, agitation speed, extraction voltage, and extraction time were studied in detail. At optimized conditions, repeatability of migration times and peak areas of 17 amino acids was better than 0.3% and 13%, respectively, calibration curves were linear in a range of two orders of magnitude (r(2)=0.9968-0.9993) and limits of detection ranged from 0.15 to 10 μM. Endogenous concentrations of 12 amino acids were determined in EME treated human serum, plasma, and whole blood. The method was also suitable for simple and rapid pretreatment and determination of elevated concentrations of selected amino acids, which are markers of severe inborn metabolic disorders.  相似文献   

13.
A commercial system that is comprised of a CE coupled to an ESI triple quadrupole mass spectrometer was equipped with two capacitively coupled contactless conductivity detectors (C4Ds). The first C4D was positioned inside the original cartridge, and the second C4D was positioned as close as possible to the ESI probe entrance by using a 3D‐printed support. The C4Ds electropherograms were matched to the ESI‐MS electropherogram by correcting their timescales by the factor LT/LD, where LT and LD are the total capillary length and the length until the C4D, respectively. A general approach for method development supporting the simultaneous conductivity and MS detection is discussed, while application examples are introduced. These examples include the use of C4D as a simple device that dismiss the use of an EOF marker, a low‐selectivity detector that continuously provide information about unexpected features of the sample, and even a detector that can be more sensitive than ESI‐MS. The C4D used in this setup proved to have a smaller contribution to the peak broadening than ESI‐MS, which allowed that a C4D, positioned at 12 cm from the inlet of an 80‐cm‐long capillary, could be used to foresee position and shape of the peaks being formed 6.8 times slower at the ESI‐MS electropherogram.  相似文献   

14.
Capillary zone electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE‐C4D) has been employed for the determination of atenolol and amiloride in pharmaceutical formulations. Acetic acid (150 mm ) was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature and injection time) was studied. Non‐UV‐absorbing L‐valine was used as internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28°C, 25 kV and using hydrodynamic injection (25 s). The separation was effected in an uncoated fused‐silica capillary (75 μm, i.d. × 52 cm). The CE‐C4D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 5–250 μg/mL for the studied analytes. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol and amiloride in different pharmaceutical tablet formulations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Fluoroacetate is a highly toxic species naturally found in plants and in commercial products (compound 1080) for population control of several undesirable animal species. However, it is non-selective and toxic to many other animals including humans, and thus its detection is very important for forensic purposes. This paper presents a sensitive and fast method for the determination of fluoroacetate in blood serum using capillary electrophoresis with capacitively coupled contactless conductivity detection. Serum blood samples were treated with ethanol to remove proteins. The samples were analyzed in BGE containing 15 mmol/L histidine and 30 mmol/L gluconic acid (pH 3.85). The calibration curve was linear up to 75 μmol/L (R2 =0.9995 for N=12). The detection limit in the blood serum was 0.15 mg/kg, which is smaller than the lethal dose for humans and other animals. Fluoride, a metabolite of the fluoroacetate defluorination, could also be detected for levels greater than 20 μmol/L, when polybrene was used for reversion of the EOF. CTAB and didecyldimethylammonium bromide are not useful for this task because of the severe reduction of the fluoride level. However, no interference was observed for fluoroacetate.  相似文献   

16.
Micro-electrodialysis (μED) and CE were combined for rapid pretreatment and subsequent determination of inorganic cations in biological samples. Combination of μED with CE greatly improved the analytical performance of the latter as the adsorption of high molecular weight compounds present in real samples on the inner capillary wall was eliminated. Fifty microliter of 80-fold diluted human body fluids such as plasma, serum and whole blood was used in the donor compartment of the μED system requiring less than 1?μL of the original body fluid per analysis. Inorganic cations that migrated through a cellulose acetate dialysis membrane with molecular weight cut-off value of 500?Da were collected in the acceptor solution and were then analyzed using CE-C?D. Baseline separation of inorganic cations was achieved in a BGE solution consisting of 12.5?mM maleic acid, 15?mM L-arginine and 3?mM 18-crown-6 at pH 5.5. Repeatability of the CE-C?D method was better than 0.5% and 2.5% for migration times and peak areas, respectively; limits of detection of all inorganic cations in the presence of 2?mM excess of Na(+) were around 1?μM and calibration curves were linear with correlation coefficients better than 0.998. Repeatability of the sample pretreatment procedure was calculated for six independent electrodialysis runs of artificial and real samples and was better than 11.8%. Recovery values between 96.3 and 110% were achieved for optimized electrodialysis conditions of standard solutions and real samples; lifetime of the dialysis membranes for pretreatment of real samples was estimated to 100 runs.  相似文献   

17.
A method to determine five fluoroquinolones (FQs), namely, rufloxacin (RUF), ciprofloxacin (CIP), enrofloxacin (ENO), gatifloxacin (GAT) and moxifloxacin (MOX), in acidic buffer by capillary electrophoresis (CE)-capacitively coupled contactless conductivity detection (C4D) technique is presented. Separation was carried out in a fused-silica capillary (42 cm × 50 μm) using a buffer composed of 10 mM tartaric acid, 14 mM sodium acetate and 15% (v/v) methanol at pH 3.8. The RSDs of the migration times and peak areas were 0.65% and 12.3% (intraday), 1.28% and 8.8% (interday), respectively. CE-C4D in combination with liquid–liquid extraction (LLE) as clean-up and preconcentration procedure, allows detection of the FQs in fortified chicken muscle samples with detection limits of 6.8–11.7 ng/g. This method shows potential in rapid determination of FQs in samples with complex matrix.  相似文献   

18.
Capacitively coupled contactless conductivity detection (C4D) has appeared as a powerful technique for the detection of compounds lacking chromogenic or fluorogenic group. Since our last review (Biomedical Chromatography 2014; 28 : 1502–1506) several new capillary electrophoresis (CE)‐C4D methods have been reported. This review provides an update of the most recent utilization of CE‐C4D in the field of pharmaceutical, biomedical and food analysis covering the period from February 2014 to October 2016. The use of CE with C4D in the pharmaceutical field has been shown in many papers. Examples illustrate the applicability of CE‐C4D in the fields of pharmaceutical, biomedical and food analysis. Finally, general conclusions and perspectives are provided.  相似文献   

19.
Enantioseparation and determination of chiral drugs are of vital importance in biochemical and pharmaceutical research due to the different biological activity, mechanism, and toxicity of individual enantiomers. As a second-generation H(1)-antagonist, cetirizine's pharmaceutical activity is mainly derived from the levocetirizine while the dextro-enantiomer is ineffective and even associated with side effects. Herein, the enantiomers of cetirizine were separated by capillary electrophoresis and identified by electronic circular dichroism. Satisfactory linear relationship was found between the circular dichroism signal at λmax and the electrophoretic peak area difference in the nonracemic mixture of enantiomers. It made possible identification and quantification of cetirizine enantiomers independent of single enantiomer standards. The method's feasibility was demonstrated on the enantiomeric excess experiments of oral drugs measured in human blank urine. Additionally, the separation and determination of cetirizine in human urine after administration were also realized by capillary electrophoresis, indicating the method was sensitive enough for pharmacokinetic study.  相似文献   

20.
A method was developed to determine traces of trifluoroacetic acid as impurity in synthetic or semi-synthetic drugs as antibiotics, macropeptides, etc. Capillary electrophoresis in combination with capacitively coupled contactless conductivity detection (CE-C4D) was used due to lack of UV absorbance property of trifluoroacetic acid (TFA). The optimized method took less than 1 min with good linearity (R2 = 0.9995) for trifluoroacetic acid concentration from 2 to 100 ppm. It also has a good repeatability expressed by the relative standard deviation (% RSD) which is 1.2 and 2.1% for intraday and interday precision, respectively, at 50 ppm TFA, and good sensitivity with 0.34 ppm, 1.2 ppm LOD and LOQ, respectively. In addition, the content of TFA in synthetic drug, was determined using the validated method which gave good linearity (R2 = 0.9996) for trifluoroacetic acid spiked into drug in a concentration range of 2-80 ppm, with good intraday repeatability of 2.0%.The analysis is performed in a background electrolyte composed of 20 mM morpholinoethane-sulfonic acid (Mes) and 20 mM l-histidine (l-His) pH 6.1. Cetyltrimethylammonium bromide (CTAB) was added as flow modifier in a concentration (0.2 mM) lower than the critical micellar concentration. Ammonium formate 6 ppm was used as internal standard. The applied voltage was 30 kV in reverse polarity. A fused silica capillary with 75 μm internal diameter and total length 47 cm (31 cm to C4D detector and 37 cm to DAD detector) was used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号