首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Constant energy synchronous luminescence spectroscopy is extended to low temperature conditions for the determination of polynuclear aromatic hydrocarbons. Low-temperature constant energy synchronous luminescence spectroscopy implements a constant energy difference between monochromators as each is scanned through the spectral region of interest. The major advantage of this development is the optimization of parameter selection used in each determination. While this investigation was performed at 77 K, theoretical considerations are extended to 4 K conditions. Application to multicomponent samples is also demonstrated.  相似文献   

2.
3.
Trace elements in oil can be determined by adsorption of the oil sample onto magnesium oxide followed by thermal degradation of the organic material. The resulting powder is easily pressed into a pellet suitable for x-ray spectrometric analysis. The lower limit of detection depends upon the trace impurities in the magnesium oxide and is a few μg g?1 for most elements determined.  相似文献   

4.
5.
Crude oil fingerprints were obtained from four crude oils by laser desorption/ionization mass spectrometry (LDI-MS) using a silver nitrate cationization reagent. Replicate analyses produced spectral data with a large number of features for each sample (>11,000 m/z values) which were statistically analyzed to extract useful information for their differentiation. Individual characteristic features from the data set were identified by a false discovery rate based feature selection procedure based on the analysis of variance models. The selected features were, in turn, evaluated using classification models. A substantially reduced set of 23 features was obtained through this procedure. One oil sample containing a high ratio of saturated/aromatic hydrocarbon content was easily distinguished from the others using this reduced set. The other three samples were more difficult to distinguish by LDI-MS using a silver cationization reagent; however, a minimal number of significant features were still identified for this purpose. Focus is placed on presenting this multivariate statistical method as a rapid and simple analytical procedure for classifying and distinguishing complex mixtures.  相似文献   

6.
A rapid and simple fractionation procedure using solid-phase extraction (SPE) cartridges was developed for an accurate determination of aliphatic and polycyclic aromatic hydrocarbons in petroleum residues and further application in chemical fingerprinting of oil spills by gas chromatography-mass spectrometry (GC-MS). Among the adsorbents evaluated, SiO2/C3-CN exhibited the best selectivity, providing, by elution with n-hexane (4 ml) and n-hexane-CH2Cl2 (1:1) (5 ml), two well-resolved aliphatic and aromatic hydrocarbon fractions, with recoveries of 97 +/- 7.2 and 99.7 +/- 13.9%, respectively. The SPE fractionation procedure was compared with the conventional silica-alumina adsorption chromatography showing similar results but practical advantages in terms of reproducibility, analysis time, solvent reduction and cost. Moreover, is particularly suitable for routine analysis with a high sample throughput. The developed methodology was tested in the characterization of fuel-oil samples collected along the Spanish north-west coast, after the Prestige oil spill accident.  相似文献   

7.
Total luminescence and synchronous fluorescence spectroscopies were tested as regards their ability to differentiate edible from lampante virgin olive oils. Total luminescence spectra were recorded by measuring the emission spectra in the range 350-720 nm at excitation wavelengths from 320 to 535 nm. The synchronous fluorescence spectra of 41 edible and 32 lampante virgin olive oils were acquired by synchronous scanning the excitation and emission monochromator maintained at an offset value of 80 nm. Classification of virgin olive oils based on their synchronous fluorescence spectra was performed by hierarchical cluster analysis and principal component analysis using the spectral range of 429-545 nm. Principal component analysis provided better discrimination between the two classes, without any classification error, while hierarchical cluster analysis allowed 97.3% correct classification. These results indicate the capability of fluorescence techniques to differentiate virgin olive oils according to their quality.  相似文献   

8.
Pavon JM  de Torres AG  Pozo ME 《Talanta》1990,37(4):385-391
The simultaneous determination of gallium and aluminium by using conventional fluorimetry and derivative synchronous fluorescence spectrometry has been studied. These determinations are based on the formation of fluorescent complexes of gallium and aluminium with salicylaldehyde carbohydrazone (SACH). In the conventional method, two samples are analysed under different analytical conditions, and the results are evaluated by solving a system of two simultaneous equations. In the derivative synchronous method (at pH = 2.6, in an ethanol-water medium containing 72% of ethanol), the following conditions are used: a constant wavelength difference of 20 nm between the monochromator settings, a time-constant of 1.5 sec, a scan-speed of 120 nm/min, and a derivative wavelength difference of 10 nm; gallium can be determined in the range 7-38 ng/ml, and aluminium between 6 and 45 ng/ml. The synchronous method shows more advantages, and has been used in the determination of both metal ions in diverse biological samples (animal tissues and human serum) with good results.  相似文献   

9.
Oil samples from Recôncavo basin (NE Brazil), previously analyzed by traditional techniques such as gas chromatography coupled to tandem mass spectrometry, were evaluated using comprehensive two‐dimensional gas chromatography coupled to quadrupole mass spectrometry and comprehensive two‐dimensional gas chromatography coupled to tandem mass spectrometry along with simplified methods of samples preparation to evaluate the differences and advantages of these analytical techniques to better understand the development of the organic matter in this basin without altering the normal distribution of the compounds in the samples. As a result, the geochemical parameters calculated by comprehensive two‐dimensional gas chromatography coupled to tandem mass spectrometry described better the origin, maturity, and biodegradation of both samples probably by increased selectivity, resolution, and sensitivity inherent of the multidimensional technique. Additionally, the detection of the compounds such as, the C(14α‐) homo‐26‐nor‐17α‐hopane series, diamoretanes, nor‐spergulanes, C19–C26 A‐nor‐steranes and 4α‐methylsteranes resolved and detected by comprehensive two‐dimensional gas chromatography coupled to tandem mass spectrometry were key to classify and differentiate these lacustrine samples according to their maturity and deposition conditions.  相似文献   

10.
A simple, fast and sensitive direct method for the simultaneous determination of Cr and Fe in crude oil samples is proposed using high-resolution continuum source graphite furnace atomic absorption spectrometry. No sample preparation is used except for a 10-minute homogenization in an ultrasonic bath. Aliquots of 0.1–4 mg of the samples are weighed onto solid sampling platforms and analyzed directly using aqueous standards for calibration. The simultaneous determination was possible because there is a secondary Fe line at 358.120 nm in the vicinity of the most sensitive Cr line at 357.868 nm, and both absorption lines were within the wavelength interval covered by the linear charge-coupled device array detector. It has also been of advantage that the sensitivity ratio between the two analytical lines corresponded roughly to the concentration ratio of the two elements found in crude oil, and that both analytes have very similar volatility, so that no compromises had to be made regarding pyrolysis and atomization temperatures. Two oil reference materials have been analyzed and the results were in agreement with the certified or reported values. Characteristic masses of 3.6 pg and 0.5 ng were obtained for Cr and Fe, respectively. The limits of detection (3σ, n = 10) were 1 µg kg− 1 for Cr and 0.6 mg kg− 1 for Fe, and the precision, expressed as the relative standard deviation, ranged from 4 to 20%, which is often acceptable for a rapid direct analytical procedure. Five crude oils samples were analyzed.  相似文献   

11.
12.
Hegazi E  Hamdan A 《Talanta》2002,56(6):989-995
Time-resolved fluorescence (TRF) spectra of six crude oils from the eastern province of Saudi Arabia were excited using a pulsed laser radiation at 250 nm and measured at specific time gates (TG) within the leading and trailing edges of the laser temporal pulse. The spectra showed the presence of a shoulder near 380 nm that systematically decreased in intensity from high-grade to low-grade crudes, and also from earlier to later TGs. The intensities of these shoulders are shown to be useful in estimating the grades of crude oils, particularly when the TRF spectra are measured at TGs within the leading edge of the laser temporal pulse. Contour diagrams depicting the shapes of the TRF spectra as function of TG (within the leading and trailing edges) are also presented to serve as true fingerprints of the crudes.  相似文献   

13.
Because of the associated experimental difficulties, natural gas hydrate behavior in black oil is poorly understood despite its grave importance in deep-water flow assurance. Since the hydrate cannot be visually observed in black oil, traditional methods often rely on gas pressure changes to monitor hydrate formation and dissociation. Because gases have to diffuse through the liquid phase for hydrate behavior to create pressure responses, the complication of gas mass transfer is involved and hydrate behavior is only indirectly observed. This pressure monitoring technique encounters difficulties when the oil phase is too viscous, the amount of water is too small, or the gas phase is absent. In this work we employ proton nuclear magnetic resonance (NMR) spectroscopy to observe directly the liquid-to-solid conversion of the water component in black oil emulsions. The technique relies on two facts. The first, well-known, is that water becomes essentially invisible to liquid state NMR as it becomes immobile, as in hydrate or ice formation. The second, our recent finding, is that in high magnetic fields of sufficient homogeneity, it is possible to distinguish water from black oil spectrally by their chemical shifts. By following changes in the area of the water peak, the process of hydrate conversion can be measured, and, at lower temperatures, the formation of ice. Taking only seconds to accomplish, this measurement is nearly direct in contrast to conventional techniques that measure the pressure changes of the whole system and assume these changes represent formation or dissociation of hydrates - rather than simply changes in solubility. This new technique clearly can provide accurate hydrate thermodynamic data in black oils. Because the technique measures the total mobile water with rapidity, extensions should prove valuable in studying the dynamics of phase transitions in emulsions.  相似文献   

14.
There is a growing need to develop analytical methods that can distinguish compounds found within industrially derived oil sands process water (OSPW) from those derived from natural weathering of oil sands deposits. This is a difficult challenge as possible leakage beyond tailings pond containments will probably be in the form of mixtures of water-soluble organics that may be similar to those leaching naturally into aquatic environments. We have evaluated the potential of negative ion electrospray ionization high-resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) for comparing oil sands polar organics from tailing ponds, interceptor wells, groundwater, river and lake surface waters. Principal component analysis was performed for all species observed. which included the O(2) class (often assumed to be monocarbxoylic naphthenic acids) along with a wide range of other species including humic substances in the river and lake samples: O(n) where n=1-16; NO(n) and N(2)O(n) where n=1-13; and O(n)S and O(n)S(2) where n=1-10 and 1-8, respectively. A broad range of species was investigated because classical naphthenic acids can be a small fraction of the 'organics' detected in the polar fraction of OSPW, river water and groundwater. Aquatic toxicity and environmental chemistry are attributed to the total organics (not only the classical naphthenic acids). The distributions of the oil sands polar organics, particularly the sulfur-containing species, O(n)S and O(n)S(2), may have potential for distinguishing sources of OSPW. The ratios of species containing O(n) along with nitrogen-containing species: NO(n), and N(2)O(n), were useful for differentiating organic components derived from OSPW from those found in river and lake waters. Further application of the FTICRMS technique for a diverse range of OSPW of varying ages and composition, as well as the surrounding groundwater wells, may be critical in assessing whether leakage from industrial sources to natural waters is occurring.  相似文献   

15.
A method was developed for the determination of trace elements in crude oil by inductively coupled plasma mass spectrometry (ICP-MS) after sample dissolution in toluene and subsequent ultrasonic nebulization (USN). Carbon build-up at the interface and ion lenses was minimized by optimization of the argon to oxygen ratio in the plasma and by the desolvating action of the USN. The analyte addition technique, combined with internal standardization (115In), was the only calibration procedure capable to correct properly for signal suppression, especially observed in solutions with higher concentrations of asphaltenes. Analytical curves with good linearity (r2>0.99), and solution detection limits (LOD–3σ) of 0.1 μg l−1 for V, Ni, Co, Y, Mo, Cd, Ba and La, and in the range of 0.1–1 μg l−1 for Al, Ti, Fe, Zn, Sr, Ag, Sn and Pb were obtained. Method validation was performed by analyzing two certified reference materials. For National Institute for Standards and Technology (NIST) 1634c (V, Ni, Co), accuracy was approximately 10%, similar as observed for other 12 elements in NIST 1084a. Asphaltenes were separated from the oil bulk of crude oil samples from the Potiguar Basin (Brazil) using precipitation in heptane. The heptane-soluble fraction (maltenes) was separated by elution chromatography into three sub-fractions: (1) saturated and low molecular mass (MM) aromatics, (2) aromatics and low MM polar compounds, and (3) high MM polar compounds (resins). Trace elements were determined in these fractions after dissolution in toluene, by USN–ICP-MS. Mass balance calculations showed a significant increase of most elements (10–30 times) in the asphaltenic fraction, and in minor proportions in fraction 3, compared to the crude oil samples. Comparison with microwave-assisted acid decomposition showed good agreement, validating the proposed methodology and emphasizing its applicability for routine analysis of crude oil and other toluene soluble petroleum products.  相似文献   

16.
A literature review on the determination of trace elements in crude oil and heavy molecular mass fractions (saturates, aromatics, resins and asphaltenes) by ICP-MS, ICP OES and AAS is presented. Metal occurrences, forms and distributions are examined as well as their implications in terms of reservoir geochemistry, oil refining and environment. The particular analytical challenges for the determination of metals in these complex matrices by spectrochemical techniques are discussed. Sample preparation based on ashing, microwave-assisted digestion and combustion decomposition procedures is noted as robust and long used. However, the introduction of non-aqueous solvents and micro-emulsions into inductively coupled plasmas is cited as a new trend for achieving rapid and accurate analysis. Separation procedures for operationally defined fractions in crude oil are more systematically applied for the observation of metal distributions and their implications. Chemical speciation is of growing interest, achieved by the coupling of high efficiency separation techniques (e.g., HPLC and GC) to ICP-MS instrumentation, which allows the simultaneous determination of multiple organometallic species of geochemical and environmental importance.  相似文献   

17.
Vale MG  Silva MM  Damin IC  Sanches Filho PJ  Welz B 《Talanta》2008,74(5):1385-1391
In recent work, it has been shown that electrothermal atomic absorption spectrometry (ET AAS) can be used to differentiate between volatile and non-volatile nickel and vanadium compounds in crude oil. In the present work, the distribution of these two groups of compounds over different fractions of crude oil was investigated. For this purpose two crude oil samples were separated in two steps: firstly, the asphaltenes were precipitated with n-heptane, and secondly, the maltenes were loaded on a silica column and eluted with solvents of increasing polarity. The four fractions of maltenes eluted from silica column were: F1, saturated and light aromatics; F2, polyaromatics; F3, resins; and F4, polar compounds. Fractions F1 and F2 were further investigated using gas chromatography, and all fractions were characterized by CHN analysis, confirming the increase of aromatics in the fractions 2, 3, 4 and asphaltenes. For the determination of Ni and V by ET AAS, oil-in-water emulsions were prepared. The speciation analysis was carried out measuring without chemical modifier (stable compounds) and with 20 μg palladium (total Ni and V) and the volatile fraction was calculated by difference. The limits of detection were 0.02 μg g−1 and 0.06 μg g−1, for Ni and V, respectively, based on an emulsion of 2 g of oil in 10 mL. The volatile species of Ni and V were associated with fractions F3 and F4, while only thermally stable Ni and V was precipitated in part together with the asphaltenes.  相似文献   

18.
Introduction: Identification of Oroxylum indicum and Scutellaria baicalensis provides an interesting challenge in selection of biomarker compound to be used in routine analysis. Both plants have similar phytochemical profile and are rich sources of flavones and flavone glycosides. The objective of this study was to prepare the chemical fingerprinting of O. indicum bark and S. baicalensis roots using the liquid chromatography and mass spectroscopy in single chromatographic method. Materials and methods: Extracts prepared using various solvent systems (methanol, aqueous methanol, chloroform, hexane, and water) of both plants were analyzed using C18 reverse phase column with solvent system containing acetonitrile and 0.1% formic acid. Major flavonoids were identified based on mass spectra, fragmentation pattern, and UV spectra. Results: In this article, well-resolved high-performance liquid chromatographic (HPLC) separation in both plant extracts was obtained and chemical fingerprints for both plant extracts were established and flavonoids present (baicalin, oroxylin A-7-O-glucuronide, chrysin-7-O-glucuronide, baicalein, chrysin, oroxylin-A, wogonin, skullcap flavone II) were identified as possible biomarkers. Conclusion: Mass spectrometry coupled with HPLC can be a tool for fingerprinting of various natural products used in dietary supplement industry. The fingerprint developed in the article can be used for quality evaluation as well as identifying possible adulteration of extracts of both the plants.  相似文献   

19.
20.
The aim of this study was to investigate the potential use of a direct headspace-mass spectrometry electronic nose instrument (MS e_nose) combined with chemometrics as rapid, objective and low cost technique to measure aroma properties in Australian Riesling wines. Commercial bottled Riesling wines were analyzed using a MS e_nose instrument and by a sensory panel. The MS e_nose data generated were analyzed using principal components analysis (PCA) and partial least squares (PLS1) regression using full cross validation (leave one out method). Calibration models between MS e_nose data and aroma properties were developed using partial least squares (PLS1) regression, yielding coefficients of correlation in calibration (R) and root mean square error of cross validation of 0.75 (RMSECV: 0.85) for estery, 0.89 (RMSECV: 0.94) for perfume floral, 0.82 (RMSECV: 0.62) for lemon, 0.82 (RMSECV: 0.32) for stewed apple, 0.67 (RMSECV: 0.99) for passion fruit and 0.90 (RMSECV: 0.86) for honey, respectively. The relative benefits of using MS e_nose will provide capability for rapid screening of wines before sensory analysis. However, the basic deficiency of this technique is lack of possible identification and quantitative determination of individual compounds responsible for the different aroma notes in the wine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号