首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and rapid liquid chromatographic/tandem mass spectrometric method was developed and validated for the determination of sertraline in human plasma. The analyte and internal standard (IS, diphenhydramine) were extracted with 3 mL of diethyl ether/dichloromethane (2:1, v/v) from 0.25 mL plasma, then separated on a Zorbax Eclipse XDB C18 column using methanol/water/formic acid (75:25:0.1, v/v/v) as the mobile phase. The triple quadrupole mass spectrometry was applied via an atmospheric pressure chemical ionization (APCI) source for detection. The fragmentation pattern of the protonated sertraline was elucidated with the aid of product mass spectra of isotopologous peaks. Quantification was performed using selected reaction monitoring of the transitions of m/z 306 --> 159 for sertraline and m/z 256 --> 167 for the IS. The method was linear over the concentration range of 0.10-100 ng/mL. The intra-day and inter-day precisions, expressed by relative standard deviation, were both less than 6.7%. Assay accuracies were within +/-6.9% as terms of relative error. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.10 ng/mL with a precision of 8.3% and an accuracy of 9.6%. The validated method has been successfully applied for the pharmacokinetic study and bioequivalence evaluation of sertraline in 18 healthy volunteers after a single oral administration of 50 mg sertraline hydrochloride tablets.  相似文献   

2.
A method using high-performance liquid chromatography (HPLC) and atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) was established for the detection of 6-(methylsulfinyl)hexyl isothiocyanate (6-MITC) and its conjugate with N-acetyl-L-cysteine (NAC). The optimal chromatographic conditions were obtained on an ODS column (150 x 4.6 mm, 3 microm) with the column temperature at 37 degrees C. The mobile phase consisted of a methanol-0.1% trifluoroacetic acid (TFA) mixture (50 : 50, v/v), and the flow rate was 0.3 ml/min. The detection wavelength was set at 220 nm. The identities of the peaks were accomplished by comparing retention times (tR), UV and mass data. All calibration curves showed good linear regression (correlation coefficients for 6-MITC and NAC>0.999) within test ranges. The developed method provided satisfactory precision calculated as percent coefficient of variation with overall intra-day and inter-day variations of less than 5% (4.1 and 4.9% for 6-MITC; 4.2 and 4.9% for NAC). Both 6-MITC and NAC had good responses in the positive APCI and formed strong [M+H]+ ions in the full scan spectra at an m/z of 206 and 164, respectively. The presence of the [M+H]+ ion for the 6-MITC/NAC conjugate was also observed at an m/z of 369. To our best knowledge, this is the first report that describes the formation of the 6-MITC/NAC conjugate and its detection method by HPLC-MS.  相似文献   

3.
4.
In time-of-flight secondary ion mass spectrometry (ToF-SIMS), the choice of primary ion used for analysis can influence the resulting mass spectrum. This is because different primary ion types can produce different fragmentation pathways. In this study, analysis of single-component protein monolayers were performed using monatomic, tri-atomic, and polyatomic primary ion sources. Eight primary ions (Cs(+), Au(+), Au(3) (+), Bi(+), Bi(3) (+), Bi(3) (++), C(60) (+)) were used to examine to the low mass (m/z < 200) fragmentation patterns from five different proteins (bovine serum albumin, bovine serum fibrinogen, bovine immunoglobulin G and chicken egg white lysozyme) adsorbed onto mica surfaces. Principal component analysis (PCA) processing of the ToF-SIMS data showed that variation in peak intensity caused by the primary ions was greater than differences in protein composition. The spectra generated by Cs(+), Au(+) and Bi(+) primary ions were similar, but the spectra generated by monatomic, tri-atomic and polyatomic primary ion ions varied significantly. C(60) primary ions increased fragmentation of the adsorbed proteins in the m/z < 200 region, resulting in more intense low m/z peaks. Thus, comparison of data obtained by one primary ion species with that obtained by another primary ion species should be done with caution. However, for the spectra generated using a given primary ion beam, discrimination between the spectra of different proteins followed similar trends. Therefore, a PCA model of proteins created with a given ion source should only be applied to datasets obtained using the same ion source. The type of information obtained from PCA depended on the peak set used. When only amino acid peaks were used, PCA was able to identify the relationship between proteins by their amino acid composition. When all peaks from m/z 12-200 were used, PCA separated proteins based on a ratio of C(4)H(8)N(+) to K(+) peak intensities. This ratio correlated with the thickness of the protein films and Bi(1) (+) primary ions produced the most surface sensitive spectra.  相似文献   

5.
Zhou Y  Luo S  Kong Y 《色谱》2012,30(2):207-210
建立了固相萃取-气相色谱-质谱联用(SPE-GC-MS)检测地沟油样品中胆固醇的分析方法。样品用硅胶固相萃取小柱前处理净化,先用20 mL含0.6%乙醚的正己烷溶液淋洗,再用10 mL含15%乙醚的正己烷溶液洗脱,胆固醇萃取率达97%。净化后的样品用配备电子轰击离子源的气相色谱-质谱联用仪进行测定,以保留时间和特征碎片离子定性,在选择离子监测模式下用外标法定量,选择离子为m/z 213、275、301、368、386,目标离子为m/z 386,参考离子为m/z 213和275。不同加标水平下的加标回收率为91.7%~101%,相对标准偏差(RSD)小于6%,检出限为0.01 mg/L。胆固醇质量浓度在0.24~6.0 mg/L范围内有良好的线性关系(相关系数为0.9996)。该法可精确检测油脂中胆固醇的含量,检测结果可作为判断其中是否掺有地沟油的依据之一。  相似文献   

6.
The positive ion electrospray mass spectra of [M+H](+) and the negative ion electrospray mass spectra of [M-H](-) ions of selected pyroglutamate containing peptides both provide sequencing data. The negative ion spectra show the normal alpha and beta backbone cleavages in addition to delta and gamma backbone cleavages initiated by the side chains of Glu and Phe residues. For example, the [M-H](-) ion of pGlu Pro Gln Val Phe Val-NH(2) shows delta and gamma peaks at m/z 224 (delta, Gln3), 244 (gamma, Phe4), 451 (delta, Phe4), 471 (gamma, Gln3). Some of the negative ion spectra show unusual grandaughter peaks that originate by alpha and beta, or delta and gamma backbone cleavages of a beta(1) cleavage ion.  相似文献   

7.
A liquid chromatography-electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous quantitation of nicorandil and its denitrated metabolite, N-(2-hydroxyethyl)-nicotinamide, in rat plasma. After a liquid-liquid extraction step, chromatographic separation was performed on a ShinPack C(18) column with an isocratic mobile phase composed of methanol and 2 mM aqueous ammonium acetate containing 0.03% (v/v) formic acid (33:67 v/v). Procainamide was used as an internal standard (IS). Selected reaction monitoring was performed using the transitions m/z 212 → m/z 135, m/z 166 → m/z 106 and m/z 236 → m/z 163 to quantify nicorandil, its denitrated metabolite and IS, respectively. Calibration curves were constructed over the range of 5-15,000 ng.ml(-1) for both nicorandil and its metabolite. The mean relative standard deviation (RSD%) values for the intra-run precision were 5.4% and 7.3% and for the inter-run precision were 8.5% and 7.3% for nicorandil and its metabolite, respectively. The mean accuracy values were 100% and 95% for nicorandil and its metabolite, respectively. No matrix effect was detected in the samples. The validated method was successfully applied to a pharmacokinetic study after per os administration of nicorandil in rats.  相似文献   

8.
王东  秦峰  陈凌云  郝彧  张轶  李发美 《色谱》2008,26(3):327-330
建立了超高效液相色谱-质谱/质谱联用法(UPLC-MS/MS)测定人血浆中辛伐他汀的浓度。血浆样品经乙醚-正己烷-异丙醇(体积比为80∶20∶3)提取,以洛伐他汀为内标,采用ACQUITY UPLCTM BEH C18柱(50 mm×2.1 mm,1.7 μm)分离,以乙腈-10 mmol/L乙酸铵水溶液(体积比为85∶15)为流动相,流速为0.25 mL/min,通过电喷雾离子化,采用多反应监测(MRM)方式进行正离子检测。线性范围为0.051~20.4 ng/mL,日内及日间测定的相对标准偏差不高于10%,平均回收率为91.6%。方法灵敏度高,分析速度快,操作简便,适用于辛伐他汀药物动力学和生物等效性研究。  相似文献   

9.
An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R'- and R,S'-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm x 2.1mm), using an isocratic mobile phase of methanol:ammonium acetate (10mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R'-fenoterol, m/z 318.1 for R,R'-methoxyfenoterol, and m/z 339.2 for R,S'-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5-100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration-time profiles of drugs after oral administration to rats of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol.  相似文献   

10.
A novel analytical method has been developed for the determination of 14 trace chlorophenols in clam tissues by ion chromatography (IC) coupled with atmospheric pressure chemical ionization mass spectrometry (APCI-MS) in the negative mode. The method comprised a fast ultrasound-assisted extraction using a mixture of methanol/water (4:1v/v) containing 5% triethylamine (TEA) as extraction solvent, solid-phase extraction with an Oasis HLB cartridge and gradient separation using KOH/acetonitrile at a flow rate of 1.0 mL/min on an IonPac AG11 guard column (50 mm x 4.0 mm I.D.) and an IonPac AS11 analytical column (250 mm x 4.0 mm I.D.). The molecular ions m/z [M-H](-) 127, 129; 161, 163; 195, 197 and 263, 265, 267 were selected for quantification in the selected ion monitoring (SIM) mode for monochlorophenols (MCPs), dichlorophenols (DCPs), trichlorophenols (TCPs) and pentachlorophenol (PCP), respectively. The average recoveries of the objective compounds spiked in clam tissues were between 80.2% and 98.2%. Within-day and day-to-day relative standard deviations were less than 12.6% and 13.2%, respectively. The optimum IC-APCI-MS conditions were successfully applied to the analyses of 14 trace chlorophenols in clam tissues.  相似文献   

11.
A sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of sodium cromoglycate (SCG) in human plasma after a nasal dose of 10.4 mg sodium cromoglycate nasal spray, using pravastatin sodium as the internal standard. The method was validated over a linear range of 0.300-20.0 ng/mL. SCG and I.S. were extracted from 1.0 mL of heparinized plasma by C(18) solid-phase extraction cartridges using methanol as eluting solvent. The dried residue was reconstituted with 100 microL of mobile phase, and 10 microL was injected onto the LC-MS/MS system. Chromatographic separation was achieved on a C(18) column (250 x 4.6 mm i.d., 5 microm particle size) with a mobile phase of methanol-acetonitrile-water (containing 2 mmol/L ammonium acetate; 42.5:42.5:15, v/v/v) at a flow rate of 0.4 mL/min. The analytes were detected with a triple quad LC-MS/MS using ESI with positive ionization. Ions monitored in the multiple reaction monitoring mode were m/z 469.0 (precursor ion) to m/z 245.0 (product ion) for SCG and m/z 447.2 (precursor ion) to m/z327.1 (product ion) for pravastatin sodium (internal standard) The average recovery of SCG from human plasma was 94.88% and the lower limit of quantitation was 0.3 ng/mL. Results from a 3-day validation study demonstrated excellent precision and accuracy across the calibration range of 0.3-20 ng/mL. The method was successfully applied to the pharmacokinetic study of SCG in healthy Chinese volunteers. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg.  相似文献   

13.
A selective, sensitive and high-throughput ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method has been developed and validated for the quantification of HIV-protease inhibitors ritonavir (RTV), lopinavir (LPV) and indinavir (IDV) in human plasma. Sample clean-up involved protein precipitation of both drugs and fluconazole used as internal standard from 100 μL human plasma. All the analytes were chromatographically separated on a Waters Acquity UPLC BEH C18 (2.1 × 50 mm, 1.7 μm particle size) analytical column using 0.1% formic acid and methanol (40:60, v/v) as the mobile phase. The parent → product ion transitions for ritonavir (m/z 721.40→ 296.10), lopinavir (m/z 629.40→ 447.40) and indinavir (m/z 614.4→ 421.0) IS (m/z 307.10 → 220.10) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive ion mode. The method was validated over the concentration range of 30-15,000 ng/mL for LPV and IDV and 3-1500 ng/mL for RTV. The method was successfully applied to a pilot bioequivalence study in 36 healthy human subjects after oral administration of lopinavir 200 mg and ritonavir 50 mg tablet formulation under fasting conditions.  相似文献   

14.
Betahistine is widely used for the treatment of vertigo. Owing to first‐pass metabolism, 2‐pyridyl acetic acid (2PAA, major metabolite of betahistine) was considered as surrogate for quantitation. A specific and sensitive LC–MS/MS method was developed and validated for quantitation of 2PAA using turbo‐ion spray in a positive ion mode. A solid‐phase extraction was employed for the extraction of 2PAA and 2PAA d6 (IS) from human plasma. Chromatographic separation of analytes was achieved using an ACE CN, 5 μm (50 × 4.6 mm) column with a gradient mobile phase comprising acetonitrile–methanol (90:10% v /v) and 0.7% v/v formic acid in 0.5 mm ammonium trifluoroacetate in purified water (100% v/v). The retention times of 1.15 and 1.17 min for 2PAA and internal standard, respectively, were achieved. Quantitation of 2PAA and internal standard was achieved by monitoring multiple reaction monitoring transition pairs (m /z 138.1 to m /z 92.0 and m /z 142.1 to m /z 96.1, respectively). The developed method was validated for various parameters. The calibration curves of 2PAA showed linearity from 5.0 to 1500 ng/mL, with a lower limit of quantitation of 5.0 ng/mL. The bias and precision for inter‐ and intra‐batch assays were <10%. The developed method was used to support clinical sample analysis.  相似文献   

15.
The fragment ion formation characteristics of the radical anions generated from hexahydro-1,3,5-trinitrotriazine (RDX) and its three nitroso metabolites were studied using GC/MS with negative chemical ionization (NCI) to understand the fragmentation mechanisms responsible for the formation of the most abundant ions observed in their NCI mass spectra. Ab initio and density functional theory calculations were used to calculate relative free energies for different fragment ion structures suggested by the m/z values of the most abundant ions observed in the NCI mass spectra. The NCI mass spectra of the four nitramines are dominated by ions formed by the cleavage of nitrogen-nitrogen and carbon-nitrogen bonds in the atrazine ring. The most abundant anions in the NCI mass spectra of these nitramines have the general formulas C(2)H(4)N(3)O (m/z 86) and C(2)H(4)N(3)O(2) (m/z 102). The analyses of isotope-labeled standards indicate that these two ions are formed by neutral losses that include two exocylic nitrogens and one atrazine ring nitrogen. Our calculations and observations of the nitramine mass spectra suggest that the m/z 86 and m/z 102 ions are formed from either the (M--NO)(-) or (M--NO(2))(-) fragment anions by a single fragmentation reaction producing neutral losses of CH(2)N(2)O or CH(2)N(2)O(2) rather than a set of sequential reactions involving neutral losses of HNO(2) or HNO and HCN.  相似文献   

16.
Simultaneous analyses of synthetic iminodipeptides containing an N-terminal proline or a C-terminal proline have been demonstrated using liquid chromatography-mass spectrometry with an atmospheric pressure ionization interface system. The separation of iminodipeptides was carried out on a reversed-phase high-performance liquid chromatographic column using 0.1% aqueous trifluoroacetic acid-methanol (75:25, v/v, pH 2.0) as mobile phase. Very intense protonated molecular ions [M + H]+ of various synthetic iminodipeptides, Pro-Gly, Gly-Pro, Pro-Ala, Ala-Pro, Pro-Val, Val-Pro, Pro-Leu and Leu-Pro, were observed. Pro-Gly (Pro-X) and Gly-Pro (X-Pro) have the same protonated molecular ion (m/z 173), but the peaks of these compounds on the mass chromatograms were clearly distinguished by the differences of the retention times and mass spectra. The synthetic iminodipeptides containing an N-terminal proline added to urine samples from a patient with prolidase deficiency were also distinguished from iminodipeptides containing a C-terminal proline in urine samples from a patient with prolidase deficiency by scanning the [M + H]+ ion of each iminodipeptide. We established the method to measure simultaneously the various iminodipeptides containing an N-terminal or a C-terminal proline in biological samples.  相似文献   

17.
串联质谱法快速分析皮革中五氯酚残留   总被引:3,自引:1,他引:2  
建立了皮革样品中五氯酚的串联质谱分析方法,以m/z266为母离子,碰撞电压为0.8V,以子离子n/z230为定量离子,外标法定量。线性范围为0.1 ̄10.0mg/L,检出限为0.005mg/kg,回收率为85.4% ̄102.5%,相对标准偏差为2.55% ̄3.55%。方法具有快速、准确的特点。  相似文献   

18.
潘胜东  陈晓红  何仟  李晓海  王立  周健  金米聪 《色谱》2017,35(12):1245-1250
建立了超高效液相色谱-高分辨质谱(UPLC-HRMS)鉴定泥鳅体内五氯酚代谢物五氯酚磺酸酯的方法。将在低浓度五氯酚下暴露的泥鳅样品粉碎,采用含8%(体积分数)三乙胺的70%(体积分数)乙腈水溶液提取,经混合阴离子交换小柱萃取净化,在ACQUITY BEH C18色谱柱(100 mm×2.1 mm,1.7μm)上分离,采用电喷雾负离子(ESI-)一级质谱全扫描加数据依赖的二级质谱扫描(full mass-ddMS2)模式测定,获得代谢物的准分子离子、同位素离子和二级质谱碎片离子的精确质量数。结果表明,五氯酚在泥鳅体内的代谢以磺化为主,没有发现羟基化和葡萄糖醛酸化。代谢物主要为五氯酚磺酸酯,其含量随着暴露时间(t)的延长逐渐增加,当暴露时间为36 h时达到峰值,随后逐渐减小,当t≥120 h时,五氯酚磺酸酯含量基本维持不变。该方法可用于生物体内五氯酚的代谢研究。  相似文献   

19.
For human urine beryllium (Be), each sample (500 microl) was diluted (1+1) with Nash reagent (containing 0.2% (v/v) acetylacetone and 2.0 M ammonium acetate buffer at pH 6.0) and then a 20-microl volume of Triton X-100 (0.4%, v/v) aqueous solution was added. An aliquot (10 microl) of the diluted urine mixture was introduced into a graphite cuvette and was atomized according to a temperature program. The method detection limit (MDL, 3sigma) for Be was 0.37 microg/l in the undiluted urine sample and the calibration graph was linear up to 65.0 microg/l. Calibration graphs were prepared by the standard addition method. Accuracies of 98.6-102% were obtained when testing standard reference material (SRM 2670) freeze dried human urine samples. Precision (relative standard deviation, RSD) for urine Be was < or = 2.3% (withinrun, n = 5) and was < or = 3.0% (between-run, n = 3). For human urine and serum selenium (Se), samples (100 microl) were diluted with HNO3 (0.2%, v/v) to make a (1+1) dilution for urine analysis or a (1+4) dilution for serum analysis. An additional aliquot (10 microl) of Triton X-100 (0.1%, v/v) was added to each 200 microl of (1+1) diluted urine (or 20 microl of the Triton X-100 was added to each 500 microl of (1+4) diluted serum) sample. After the diluted sample mixture (10 microl) was introduced into a graphite cuvette, the corresponding chemical modifier (10 microl, containing Ni2+ + Pd + NH4NO3 in HNO3 (0.2%, v/v)) was added to it and the mixture was atomized. The MDL (3sigma) for Se in urine and in serum was 4.4 and 21.4 microg/l in undiluted sample, respectively, and the calibration graphs were linear up to 150 and 400 microg/l. Accuracies of urine Se were 98.9 - 99.4% by testing SRM 2670 (NIST) urine standards with RSD (between-run, n = 3) within 2.9%; and that of serum Se was 97.2% when testing a certified second-generation human serum (No. 29, #664) with RSD (between-run, n = 3) of 1.4%. The proposed method can be applied easily, directly, and accurately to the measurement of Be and Se in real samples (including six urine Se and four serum Se from patients of Blackfoot Disease in Taiwan).  相似文献   

20.
A method for the comprehensive profiling of intact glucosinolates (GLSs), major and minor, occurring in leaves and seeds of rocket salad (Eruca sativa L.) is presented using optimized reversed-phase liquid chromatography (RP-LC) with electrospray ionization (ESI) ion trap mass spectrometry (ITMS). ESI-ITMS in the negative mode was confirmed to be very suitable to analyze these compounds in crude extracts. After extraction from the plant material with methanol/water (70:30 v/v) at 70 degrees C, the analytes of interest were separated on a C18 column using an eluent acidified with formic acid (0.1%) and modified with acetonitrile. All the GLSs found in leaves of rocket salad gave good signals corresponding to the deprotonated precursor ion, [M-H]-. Although the mass spectra also exhibited an analytically important non-covalent adduct ion at [2M-H]-, the structures of glucosinolates were confirmed by extensive sequential MS analysis, thereby substantially improving the identification of unknown compounds. The results obtained not only revealed in leaves of E. sativa at least twelve species of GLSs including seven aliphatic compounds (glucoraphanin with [M-H]- at m/z ratio of 436, glucoerucin at m/z 420, 4-mercaptobutyl-GLS at m/z 406, progoitrin/epiprogoitrin at m/z 388, sinigrin at m/z 358, 4-methylpentyl- and n-hexyl-GLS at m/z 402) and three indole glucosinolates (i.e., three N-heterocyclic compounds: 4-hydroxyglucobrassicin and 5-hydroxyglucobrassicin at m/z 463, and 4-methoxy-glucobrassicin at m/z 477), but also two structurally related compounds containing one intermolecular disulfide linkage (4-(beta-D-glucopyranosyldisulfanyl)butyl-GLS at m/z 600 and a dimeric 4-mercaptobutyl-GLS at m/z 811). This latter symmetric disulfide was previously considered as an artefact formed during extraction of GLSs from vegetative tissues. Glucosinolates were detected in the leaves with a wide range of contents (10-200 micromol/g) and a great variation in the composition. Only three GLSs were identified in seeds of rocket salad, namely glucoraphanin, glucoerucin and 4-methoxyglucobrassicin. As expected, the most abundant GLS in seeds is glucoerucin. The feasibility of the strategy was also demonstrated using a rapeseed extract of certified reference material (BCR367R). The results indicated the usefulness of this method for a rapid, sensitive and comprehensive profiling of the GLS family naturally occurring in extracts of crude plant matter.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号