共查询到20条相似文献,搜索用时 15 毫秒
1.
The use of olaquindox (OLA) as an additive in animal feedstuffs has been prohibited in the European Union and many other countries.
In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for determination
of OLA in animal feed samples was developed. OLA was activated by N′N-carbonyldiimidazole and coupled with bovine serum albumin (BSA) and ovalbumin (OVA). It was found that the sensitivity and
specificity of the two antisera were very similar, with the IC50 values of 16 ng mL−1 and 19 ng mL−1, respectively. Cross-reactivity was less than 35% for four structurally related compounds and no recognition of five other
antibiotics was observed. The better antiserum I was selected for further experiments, for example testing stability, solvent
effect, accuracy, and precision. The IC50 value for eight standard curves was in the range 12–18 ng mL−1 and the LOD at a signal-to-noise ratio of 3 (S/N = 3) was 0.31 ± 0.11 ng mL−1. The ELISA tolerated 5% methanol without significant influence on IC50 value. The recoveries of spiked OLA in five different animal feed types including auxin, pig complex feed, fish complex feed,
broiler concentrated feed, and pig premix feed were in the range 88.3–119.0% and the intra-assay relative standard deviation
(RSD) was within 4.7–33.5% (n = 3). The ELISA for unspiked feed samples was confirmed by high-performance liquid chromatography (HPLC), with a high correlation
coefficient of 0.9862 (n = 5). The proposed ELISA could be a feasible quantitative/screening method for OLA analysis in feed samples with the properties
of high sensitivity, specificity, simplicity of sample pretreatment, high sample throughput, and low expense.
Figure Polyclonal antibody based ELISA for detection of olaquindox 相似文献
2.
分别将酮洛芬与牛血清白蛋白(BSA)及卵清蛋白(OVA)偶联制得免疫原和包被原,经过免疫新西兰白兔制备多克隆抗体,抗体经纯化后效价为1:128000。使用自制的抗体,建立了测定酮洛芬的间接竞争酶联免疫吸附(ic-ELISA)新方法。ic-ELISA的线性范围为0.010~10.0μg/L,IC50为0.235μg/L,最低检测限为0.0040μg/L,线性回归方程为y=-22.97ρ+104.5(R2=0.980),与布洛芬、双氯酚酸的交叉反应率均小于4%,方法可用于水体中酮洛芬的检测。 相似文献
3.
Huihua Qu Xueqian Wang Baoping Qu Hui Kong Yue Zhang Wenchao Shan Jinjun Cheng Qingguo Wang Yan Zhao 《Analytica chimica acta》2016
Among the currently used immunoassay techniques, sandwich ELISA exhibits higher specificity, lower cross-reactivity, and a wider working range compared to the corresponding competitive assays. However, it is difficult to obtain a pair of antibodies that can simultaneously bind to two epitopes of a molecule with a molecular weight of less than 1000 Da. Naringin (Nar) is a flavonoid with a molecular mass of 580 Da. The main aim of this study was to develop a sandwich ELISA for detecting Nar. Two hybridomas secreting anti-Nar monoclonal antibodies (mAbs) were produced by fusing splenocytes from a mouse immunised against Nar-bovine serum albumin (BSA) conjugated with a hypoxanthine–aminopterin–thymidine (HAT)-sensitive mouse myeloma cell line; a sandwich ELISA for detecting Nar was developed using these two well-characterised anti-Nar mAbs. The performance of the sandwich assay was further evaluated by limit of detection (LOD), limit of quantification (LOQ), recovery, and interference analyses. A dose-response curve to Nar was obtained with an LOD of 6.78 ng mL−1 and an LOQ of 13.47 ng mL−1. The inter-assay and intra-assay coefficients of variation were 4.32% and 7.48%, respectively. The recovery rate of Nar from concentrated Fructus aurantii granules was 83.63%. A high correlation was obtained between HPLC and sandwich ELISA. These results demonstrate that the sandwich ELISA method has higher specificity for Nar than indirect competitive ELISA. 相似文献
4.
Soybean protein has long been recognized as a source of dietary allergens for humans and animals with β-conglycinin being the major allergen. This paper presents a sandwich enzyme-linked immunosorbent assay (ELISA) that allows for the detection of trace amount of β-conglycinin in soybean and soybean products. In the sandwich ELISA, mouse anti-β-conglycinin monoclonal antibody (Mab 5C5) was used as coating antibody, and rabbit anti-β-conglycinin polyclonal antibody (Pab) was used as secondary antibody. The assay showed high specificity for β-conglycinin with minimum cross-reactions with other soy proteins. The practical working range for the determination of β-conglycinin using the developed assay was 3–100 ng mL−1 and the limit of determination (LOD) was 1.63 ng mL−1. The recoveries of β-conglycinin in spiked soybean samples were between 88.1% and 106.6% with relative standard deviation less than 8.9% (intra-day) and 13.1% (inter-day). The developed method was used to analyze 469 soybean seed samples from different sources as well as five soybean products treated with different processing techniques. The data showed that the concentration of β-conglycinin decreased significantly after processing, especially for soybean protein isolation, where the concentration of β-conglycinin dropped to nearly zero. The assay provides a specific and sensitive method for the screening of β-conglycinin and allows for further investigation into hypersensitive mechanisms of soybean proteins and development of soybean processing techniques to reduce their negative effects. 相似文献
5.
3-Succinylaconitine was conjugated with bovine serum albumin (BSA) for use as an immunogen for the preparation of a monoclonal antibody (MAb) against aconitine (Aco). Splenocytes from mice immunized with the Aco-BSA conjugate were fused with an aminopterin-sensitive mouse myeloma cell line, P3-X63-Ag8-653, and a hybridoma secreting a MAb against Aco was successfully obtained. The MAb cross-reacted with mesaconitine, hypaconitine and jesaconitine, which are Aco-type alkaloids, but not with any other compounds examined. The full measurement range of an enzyme-linked immunosorbent assay (ELISA) developed using the new MAb extended from 100 ng mL−1 to 1.5 μg mL−1 of Aco. The concentrations of Aco-type alkaloids in various Aconiti radixes assayed using the new ELISA method showed good agreement with previous reports. 相似文献
6.
A new competitive enzyme-linked immunosorbent assay (ELISA) for determination of estrogenic bisphenols 总被引:8,自引:0,他引:8
Bisphenol A and other hydroxylated diphenylalkanes (generally known as bisphenols) have been identified as potential estrogenic substances. In this paper, a specific polyclonal antibody was produced against these compounds by immunization of rabbits with a conjugate of 4,4-bis (4-hydroxyphenyl) valeric acid and bovine serum albumin (BHPVA-BSA). The polyclonal antibody showed specific recognition of the bisphenol structure, while the cross reactions of other common phenolic compounds such as phenol, hydroquinol and p-hydroxybenzoic acid were all lower than 1%. The linear range of bisphenol A calibration curve was 1–10 000 ng ml−1. Real water samples and mouse serum samples were spiked with known amount of bisphenol A and measured by the competitive ELISA. Recoveries were between 92 and 105%. The detection limits were found to be 0.1 ng ml−1 for real water samples and 2 ng ml−1 for serum samples. The method is very useful for monitoring bisphenol compounds in environmental and biological samples. 相似文献
7.
Chuan-Lai Xu Chi-fang Pen Kai Hao Zheng-yu Jin Xiao-gang Chu 《International journal of environmental analytical chemistry》2013,93(11):819-832
19-Nortestosterone (17β-NT) was oximated by carboxymethoxylamine and then coupled with bovine serum albumin (BSA) in a mixed-anhydride reaction in order to produce an antibody. The conjugate rate of 17β-NT and BSA was estimated to be 24 by ultraviolet spectrophotometry. Polyclonal antibody of 17β-NT was acquired from the animal immunized with the conjugate. Through an indirect enzyme-linked immunosorbent assay (ELISA), which demonstrated that the synthesis of immunogen was successful, the titre of antiserum was found to be 6.4?×?105. Based on the purified antibody, a competitive indirect ELISA was developed. ELISA revealed that the limit of detection (LOD) was 0.07?ng?g?1, the recovery (in edible tissues) was 71–89%, and the working range was 0.05–31.25?ng?g?1. The preliminary evaluation of assay performance through specificity, sensitivity, precision, and accuracy revealed that this ELISA method could be used in the practical detection of 17β-NT in tissue samples. Moreover, this method was compared with high-performance liquid chromatography tandem mass spectrometry, for which the transition for quantification of 17β-NT was 275.4/109.1. 相似文献
8.
Zachariasova M Hajslova J Kostelanska M Poustka J Krplova A Cuhra P Hochel I 《Analytica chimica acta》2008,625(1):77-86
Enzyme-linked immunosorbent assays (ELISAs) are often employed for the control of deoxynivalenol (DON) in barley and other intermediates involved in beer production chain. Because of the occurrence of high levels of DON-3-glucoside (DON-3-Glc) in malt and beer that have been reported for the first time in our earlier study, research focused on the accuracy of DON determination by immunoassays in cereal-based matrices has been initiated. DON-3-Glc was strongly cross-reacting in all examined commercial ELISA test kits (Ridascreen® DON (R-Biopharm), Veratox 5/5 DON® (Neogen Corporation), Deoxynivalenol EIA (Euro-Diagnostica), and AgraQuant® DON Assay 0.25/5.0 Test Kit (Romer Labs). The highest overestimation in beer analysis, up to 1000%, when taking the DON content determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) as a reference method, was obtained by AgraQuant assay. Besides of DON-3-Glc and 3- and 15-acetyldeoxynivalenol (ADONs), also other, not known yet, matrix components contributed to false positive results. Similar phenomenon, although in a lesser extent due to lower content of these substances, was observed for using ELISA in the analysis of wheat. The relationship between a way of sample handling and DON overestimation was demonstrated; higher ELISA response was measured in an aqueous extract compared to that prepared by acetonitrile-water (84:16, v/v). Most of cross-reacting co-extracts were removed by MycoSep™# 226 cartridge, what leads us to the hypothesis on the presence of currently unknown cross-reactive species. 相似文献
9.
Papaverine (1-(3,4-dimethoxybenzyl)-6,7-dimethoxyisoquinoline, PAP) is a member of the benzylisoquinoline sub-group of the opium alkaloids. It has been widely used for treating diseases like pulmonary arterial embolism and renal or biliary colic. In this paper, a specific conjugate of mono-demethylated papaverine-O-carboxylmethyl ether (MDMPAP-O-CME) and bovine serum albumin (BSA) was synthesized and used as the complete antigen (PAP-BSA), with which we successfully obtained a high-titer anti-PAP polyclonal antibody (pAb) by immunization of rabbits. The anti-PAP pAb showed high affinity to papaverine with an affinity constant (Kaff) of 7.3 × 107 L/mol. With this antibody, we established a sensitive immunochemical method for the determination of papaverine based on indirect competitive enzyme-linked immunosorbent assay (ELISA). The optimal concentrations of the coated antigen (PAP-OVA) and purified pAb used in the ELISA were 5 and 1.2 μg/mL, respectively. The cross reactivity of other benzylisoquinoline derived substances, including 1-(3,4-dihydroxybenzyl)-7-hydroxy-6-methoxy-isoquinoline (6-methoxy-papaveroline, MPAPO), morphine (MP) and codeine (CD) were all lower than 1%. The linear range of the calibration curve was 0.1-1000 ng/mL. Normal human serum samples were spiked with known amount of papaverine and measured by the ELISA. Recoveries were between 102% and 105%. Papaverine content in a commercial papaverine hydrochloride injection sample was also determined using the established ELISA. Compared with the results given by the control experiment of HPLC, the recoveries of ELISA to detect injection samples were 102-110%. The limits of detection for synthetic serum samples and injection samples of papaverine hydrochloride were 0.25 and 0.06 ng/mL, respectively. 相似文献
10.
Gorawit Yusakul Orapin Udomsin Thaweesak Juengwatanatrakul Hiroyuki Tanaka Chaiyo Chaichantipyuth Waraporn Putalun 《Analytica chimica acta》2013
Pueraria candollei associated preparation is widely applied in folk Thai medicine for rejuvenating purpose in aged people, which correlated with its pharmacological activities reported by pre-clinical and clinical trials. Therefore, standardized products of this plant are needed by consumers and health care personnel. Miroestrol, a potent and stable phytoestrogen in P. candollei, exhibited potential to be biomarker for quality control of P. candollei samples in research or industrial levels. Indirect competitive enzyme-linked immunosorbant assay (ELISA) for miroestrol determination was developed and validated by using polyclonal antibody from rabbit immunization. The polyclonal antibody recognized specifically to miroestrol, which exhibited cross-reactivity to deoxymiroestrol and isomiroestrol with 6.68% and 1.05%, respectively. The linearity range of measurement was 0.73–3000 ng mL−1, which coefficient of variation (CV) of both intra- and inter-plate determination was less than 5%. With spiked samples of known amount miroestrol, the percentages of recovery were 98.80–104.37% and 98.31–106.69% in P. candollei and its involved product samples, respectively. Validated ELISA was comparable with published HPLC method (R2 = 0.9996) (Yusakul et al. [18]) in samples with various miroestrol contents. For application, the P. candollei involved preparations contained miroestrol 0.695 ± 0.037–12.108 ± 0.285 μg g−1 dry wt. The developed ELISA was high performance for miroestrol determination, which could be applied for P. candollei quality control in research fields and industrial productions. 相似文献
11.
Hesp BR Harrison JC Selwood AI Holland PT Kerr DS 《Analytical and bioanalytical chemistry》2005,383(5):783-786
In 1987 a large-scale incident of human poisoning in Canada was traced to commercial mussels contaminated with domoic acid
(DOM). Since then, routine screening of shellfish domoic acid content has been carried out using a variety of assays, with
liquid chromatography using ultraviolet absorbance detection (LC–UV) or mass spectrometric detection (LC–MS) being the currently
accepted standard methodologies. Recently, a highly specific competitive enzyme-linked immunosorbent assay (cELISA) has been
developed for the detection and analysis of DOM in commercial shellfish, but its accuracy relative to LC methods has not been
independently verified in mammalian tissues. In this study we demonstrate that measurement of rat serum DOM concentration
by cELISA gives a good correlation (r
2=0.993) across a broad range of concentrations when compared to LC–MS analysis, with only a small (15%) overestimation of
sample DOM content. In addition, we have developed an extraction method for analysis of DOM in rat brain by cELISA which yields
complete recovery across a range of sample dilutions. 相似文献
12.
Development of an enzyme‐linked immunosorbent assay and immunoaffinity chromatography for glycyrrhizic acid using an anti‐glycyrrhizic acid monoclonal antibody 下载免费PDF全文
Wenhao Zeng Yan Zhao Wenchao Shan Xueqian Wang Qingguo Wang Yan Zhao 《Journal of separation science》2015,38(13):2363-2370
In this work, a new monoclonal antibody specific for glycyrrhizic acid was prepared and characterized. A hybridoma secreting an anti‐glycyrrhizic acid monoclonal antibody was produced by fusing splenocytes from a mouse immunized against a glycyrrhizic acid–bovine serum albumin conjugate with the hypoxanthine–aminopterin–thymidine‐sensitive mouse myeloma cell line (Sp2/0‐Ag14). Subsequently, an indirect, competitive enzyme‐linked immunosorbent assay for glycyrrhizic acid was developed using the monoclonal antibody. In this assay, we detected an effective measuring range of 78.12–2500 ng/mL. Both intra‐assay and inter‐assay repeatability and precision were achieved, with relative standard deviations lower than 10%. In addition, glycyrrhizic acid levels in both formulated Chinese medicines and biological samples were determined with high sensitivity and efficiency. We then successfully developed a reliable immunoaffinity chromatography to separate glycyrrhizic acid completely from its parent medicine. These methods will contribute to further research investigations to better understand the interactions of glycyrrhizic acid with other drugs in the complex system of traditional Chinese medicine. 相似文献
13.
Chan-Yuan YAO Jin-Yi YANG Zhen-Lin XU Hong WANG Hong-Tao LEI Yuan-Ming SUN Yuan-Xin TIAN Yu-Dong SHEN 《分析化学》2018,46(8):1275-1281
A specific polyclonal antibody was prepared based on a new hapten with stable structure. Based on this, an indirect competitive enzyme-linked immunosorbent assay (icELISA) was established for determination of tylosin residues in food and environmental samples. The experimental conditions were optimized as follows: the coating antigen and antibody were respectively diluted by 6000 times and 2000 times, and the competitive reaction time was 40 min. Under the optimized conditions, the method showed a detection limit of 0.07 ng mL?1, an IC50 of 1.39 ng mL?1 and a linear range of 0.17–11.0 ng mL?1. The recoveries of spiked raw milk and water samples were ranged from 78.4% to 105.6%, with the RSDs of less than 15%. Good correlation between icELISA and HPLC method was obtained for spiked samples (R2 = 0.97). This method was suitable for the determination of tylosin residues in milk and water samples. 相似文献
14.
A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodies 总被引:1,自引:0,他引:1
Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria (blue-green algae), and microcystin-leucine-arginine (MC-LR) is among the most frequent and most toxic microcystin congeners. In this study, a free amino group was introduced to MC-LR at its seventh amino acid residue with 2-mercaptoethylamine, and the product aminoethyl-MC-LR was coupled to bovine serum albumin (BSA) and horseradish peroxidise (HRP) by glutaraldehyde to be complete antigen (MC-LR-BSA) and labelled hapten (MC-LR-HRP), respectively. Polyclonal antibodies against MC-LR were generated by immunization with MC-LR-BSA. A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was established to detect the MCs in waters, which showed a good cross-reactivity with MC-LR, MC-RR, MC-YR, MC-LF, MC-LW and nodularin, and have a detection limit for MC-LR 0.12 μg L−1, the 50% inhibition concentration (IC50) for MC-LR was 0.63 ± 0.06 μg L−1 and the quantitative detection range was from 0.17 to 2.32 μg L−1, the analysis result of water samples showed good recovery and reliability. So the comprehensive and reliable dc-ELISA will well potentially suit for sensitive analysis for total MCs in drinking as well as resource water samples. 相似文献
15.
Five different haptens of the N-methylcarbamate insecticide metolcarb were designed and synthesized. All of the haptens were conjugated with ovalbumin (OVA) for the coating antigen, and one hapten containing all of the structure of metolcarb was conjugated with bovine serum albumin (BSA) for the immunogen. Two polyclonal antisera were raised against the BSA conjugate, and ten antibody/coating conjugate combinations were selected for studies of assay sensitivity and specificity for metolcarb. A class-specific combination was found, with the I50 of the assay ranged from 0.64 to 20.98 μg mL−1 for seven tested N-methylcarbamate insecticides except for pirimicarb. Considering titer, I50 and cross-reactivity of all combinations of antibody/coating conjugate, a competitive indirect enzyme-linked immunosorbent assay (ELISA) in a homologous system, whose limit of detection (LoD) reached 1.4 ng mL−1, was presented. The results of competitive ELISAs indicated that coating hapten structure can significantly affect not only assay sensitivity but also its specificity. 相似文献
16.
本研究报道一种高灵敏度的测定自来水和表面水中药物残留双氯芬酸钠含量的间接酶联吸附分析法(ELISA)。在包被抗原为20μg/L,抗体为1∶20000倍稀释,辣根过氧化物酶-羊抗兔IgG为1∶20000倍稀释的优化条件下,双氯芬酸钠的检出限(LOD)为0.004μg/L~0.008μg/L,IC50值(标准曲线中吸光度抑制至最大吸光度值的50%时所对应的待测物浓度)为0.03μg/L~0.12μg/L。双氯芬酸钠在自来水中和表面水中的回收率分别为96%和113%。表面水存在一定的基体效应,但仅需要简单过滤稀释就可以消除。 相似文献
17.
In order to establish ELISA (enzyme-linked immunosorbent assay) method to detect Total E. coli in water environment, E. coli multi-characters antigens in water environment were prepared according to the characters of kinds of E. coli serotypes, including antigen of whole cell, antigen of disrupted whole cell, somatic antigen, flagellar antigen and fimbrial antigen. Total E. coli polyclonal antibodies were obtained from the New Zealand rabbits immunized with these five antigens, respectively. Antibodies generated in this research are with high titers and good purity, can conjugate with antigens, specifically, stably and strongly. Indirect ELISA shows the titers of antibody of whole cell and antibody of disrupted whole cell are both over 1 × 105. The cross-reactivity of the antibody is from 12 to 30% which indicate the specificity of the antibody against Total E. coli. Based on these antibodies, we established indirect ELISA method to detect Total E. coli in water environment. The matrix effects were studied and the results show that there is no significant influence by all the factors. The ELISA result shows that the detection limitation could be 104 CFU (colony forming units) L−1. The indirect ELISA method developed in this study is well suited for Total E. coli analysis in real water samples as a rapid screen method. 相似文献
18.
Loop-mediated isothermal amplification in conjunction with enzyme-linked immunosorbent assay (LAMP-ELISA) provides a sensitive, specific and cost-effective method for detection of etiological causes of infections. The present study developed a reliable LAMP-ELISA diagnostic kit for identification of Salmonella serogroup D strains and evaluated its potential use in the detection of Salmonella serovars Enteritidis and Typhi. The LAMP-ELISA assay used a serogroup D/A-specific primer set to amplify a region of the prt gene, followed by hybridization of the digoxigenin-labeled products to a highly specific oligonucleotide probe for exact identification of serogroup D serovars. Among the bacteria tested, a positive reaction was only observed for strains belong to Salmonella serogroup D. The detection limit of the LAMP-ELISA assay was 4 CFU per tube, which was lower than PCR-ELISA assay with the same target gene (50 CFU per tube). Finally, the technique was successfully applied to an artificially contaminated meat sample with a detection limit 103 CFU mL−1, which was 10 times more sensitive than PCR-ELISA. Overall, the LAMP-ELISA assay could be used as a sensitive alternative method to PCR-ELISA for the specific detection of Salmonella serogroup D serovars in routine food microbiology or clinical laboratories worldwide. 相似文献
19.
Jing-Wei Sun Bing Liu Yan Zhang Shuo Wang 《Analytical and bioanalytical chemistry》2009,394(8):2223-2230
The development of a direct competitive enzyme-linked immunosorbent assay based on polyclonal antibodies for N-methylcarbamate insecticide metolcarb is described. Two new haptens for the metolcarb were designed and synthesized. Both
haptens were conjugated with keyhole limpet hemocyanin to form the immunogens. Four rabbits were immunized with the immunogens
for production of polyclonal antibodies against metolcarb. Antisera titers were tested on the homologous coating antigens
using a noncompetitive indirect enzyme-linked immunosorbent assay. The high titer antisera were used to develop the direct
competitive enzyme-linked immunosorbent assay for the detection of metolcarb. The antibody–antigen combination with the highest
selectivity for metolcarb was further optimized and its tolerance to changes in chemical conditions (ionic strength, pH value,
and organic solvent) was studied. Under optimum conditions, the sensitivity and the limit of detection were determined to
be 22 μg L−1 and 1.2 μg L−1 respectively. Determination of metolcarb in fruit juices and vegetables was accomplished by simple, rapid, and efficient
extraction methods. Recoveries of metolcarb from spiked samples ranged from 80.5% to 109.5%. Validation of the developed immunosorbent
assay was conducted by comparison of results from high-performance liquid chromatography. The correlation between the data
obtained using developed immunosorbent assay and high-performance liquid chromatography was high (R
2 = 0.9884). Therefore, the developed immunosorbent assay in this study was suitable for the rapid quantitative determination
of metolcarb in agricultural products. 相似文献
20.
A simple competitive enzyme-linked immunosorbent assay (cELISA) was established for rapid measurement of secretory immunoglobulin A (sIgA) in saliva. The method was based on competitive reaction between the immobilized IgA and free IgA in the solution for the limited amount of horseradish peroxidase-conjugated rabbit anti-human IgA. In comparison with the conventionally used Sandwich ELISA, the cELISA is simpler, low-cost, and shows better reproducibility since it is not affected by the variation of capture antibodies from different batches. The assay time was also significantly reduced from more than 5 h to less than 3 h. Different curve-fitting models were compared, among which the fully specified logit-log model gave the best results. The linear working range and limit of detection were found to be 0.1-100 μg mL−1 and 0.05 μg mL−1, respectively. Matrix effects of saliva samples were investigated and a reasonable range of dilution factors were proposed. The developed method offers a very practical approach for high-throughput measurement of sIgA in saliva samples. 相似文献