首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOF-MS) was applied to the trace analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). To determine the optimum wavelength for analysis of PCDD/Fs, the wavelength of the femtosecond laser utilized for multiphoton ionization was converted to near-ultraviolet status using stimulated Raman scattering. A femtosecond laser emitting at 300 nm completely eliminated the background signal arising from the bleeding compounds generated from a stationary phase of the capillary column in GC.  相似文献   

2.
3.
For this study, multiphoton ionization/mass spectrometry using an ultraviolet (UV) femtosecond laser was employed for the trace analysis of organic compounds. Some of the molecules, such as dioxins, contain several chlorine atoms and have short excited-state lifetimes due to a "heavy atom" effect. A UV femtosecond laser is, then, useful for efficient resonance excitation and subsequent ionization. A technique of multiphoton ionization using an extremely short laser pulse (e.g., <10 fs), referred to as "impulsive ionization," may have a potential for use in fragmentation-free ionization, thus providing information on molecular weight in mass spectrometry.  相似文献   

4.
A gas chromatography-tandem quadrupole mass spectrometry (GC-MS/MS) method for the determination of twelve priority pesticides, and transformation products (e.g. metabolites) specified in the EU Baby Food Directive 2003/13/EC is described. Prior to GC-MS/MS analysis, co-extractives were removed from acetonitrile extracts using dispersive solid phase extraction with octadecyl (200 mg) and primary secondary amine (50 mg) sorbents. The clean up proved essential for the satisfactory long-term chromatographic performance during the analysis of a range of representative commercially pre-prepared baby food samples. Extracts spiked with pesticides at 1-8 microg kg(-1), yielded average recoveries in the range 60-113% with relative standard deviations less than 28%.  相似文献   

5.
The effect of solvent on the solution inlet/laser vaporization technique for multiphoton ionization/time-of-flight mass spectrometry (MPI/TOF-MS) was examined. In this technique, a sample of dibenzofuran, dissolved in an organic solvent, is introduced underneath the nozzle for jet expansion through a narrow capillary, at the end of which a glass frit is formed to vaporize the solvent and to deposit the analyte for laser vaporization. The ion signal, consisting of irregular peaks, is increased by the introduction of a laser pulse for vaporization, when methanol is used as a solvent. This can be attributed to local boiling of the solution at the surface of the frit due to the volatile nature of methanol. When glycerin was added to the methanol, the irregular peaks were substantially decreased. However, an increase in signal intensity was not observed by laser vaporization when the glycerin content was increased to 50%. In the case of n-nonane, which is currently used as a solvent for dissolving dioxin standards, no irregular peaks were observed and the signal intensity was increased by laser vaporization.  相似文献   

6.
This work reports a rapid, specific and sensitive multi-residue method based on the Quick Easy Cheap Effective Rugged and Safe (QuEChERS) sample preparation method and gas chromatography with mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM) using one quantification ion and two identification ions for the routine analysis of 203 pesticides in rice paddies. Analyses of fortified rice paddy samples were performed at different levels (0.05, 0.20 and 0.50 mg kg−1). Mean recoveries from five replicates ranged from 75% to 115%, with coefficients of variation lower than 17%. The limit of quantification was in the range of 0.002-0.05 mg kg−1 for the pesticides. 1040 rice paddy samples were analyzed for method application.  相似文献   

7.
Analysis of environmental samples usually requires time consuming sample preparation and clean-up procedures prior to instrumental detection. Faster analysis requires an enhanced instrumental selectivity in order to reduce the necessary clean-up effort. In this context we present a novel concept for coupling gas chromartography/mass spectrometry (GC-MS) with high resolution UV spectoscopy to increase selectivity. We use UV-laser induced, resonance-enhanced multi-photon ionization (REMPI)as a compound specifie ion source for time-of-flight mass spectrometry (TOFMS). The REMPI ionization involves the UV absorption spectroscopy into the ionization process as an aditional analytical dimension. The heart of the GC-REMPI-TOFMS coupling is a specially designed valve, which repetitively (20 Hz) expands the chromatographic eluent as short supersonic jet gas pulses (≈ 150 μs duration) into the vacuum of the mass specrtrometer. The sample molecules are cooled down to temperatures of 10-40 K within the jet expansion. Under these conditions, UV absorption spectriscopy (i.e. REMPi spectroscopy) becomes highly compound selective, even able to distinguish isomeric compounds. The ions formed by REMPI ionization are mass analyzed in the TOFMS. Thus the GC-REMPI-TOFMS coupling presented here is actually a three-dimensional analytical instrument, providing gas chromatographic (retention time) as well as mass spectrometric (molecular mass) and UV -spectroscopic (excitation laser wavelength) selectivity. In combination with gas phase sampling and concentration techniques for semi-volatile organic air pollutants based, e.g., on silicone rubber traps the GC-LAMS technique can be a powerful tool for fast environmental target analysis, e.g. for industrial emission control purposes.  相似文献   

8.
Accurate isotope ratio measurements are of high importance in various scientific fields, ranging from radio isotope geochronology of solids to studies of element isotopes fractionated by living organisms. Instrument limitations, such as unresolved isobaric inferences in the mass spectra, or cosampling of the material of interest together with the matrix material may reduce the quality of isotope measurements. Here, we describe a method for accurate isotope ratio measurements using our laser ablation ionization time‐of‐flight mass spectrometer (LIMS) that is designed for in situ planetary research. The method is based on chemical depth profiling that allows for identifying micrometer scale inclusions embedded in surrounding rocks with different composition inside the bulk of the sample. The data used for precise isotope measurements are improved using a spectrum cleaning procedure that ensures removal of low quality spectra. Furthermore, correlation of isotopes of an element is used to identify and reject the data points that, for example, do not belong to the species of interest. The measurements were conducted using IR femtosecond laser irradiation focused on the sample surface to a spot size of ~12 μm. Material removal was conducted for a predefined number of laser shots, and time‐of‐flight mass spectra were recorded for each of the ablated layers. Measurements were conducted on NIST SRM 986 Ni isotope standard, trevorite mineral, and micrometer‐sized inclusions embedded in aragonite. Our measurements demonstrate that element isotope ratios can be measured with accuracies and precision at the permille level, exemplified by the analysis of B, Mg, and Ni element isotopes. The method applied will be used for in situ investigation of samples on planetary surfaces, for accurate quantification of element fractionation induced by, for example, past or present life or by geochemical processes.  相似文献   

9.
A wide-scope screening method was developed for the detection of pesticides in fruit and vegetables. The method was based on gas chromatography coupled to a hybrid quadrupole time-of-flight mass spectrometer with an atmospheric pressure chemical ionization source (GC-(APCI)QTOF MS). A non-target acquisition was performed through two alternating scan events: one at low collision energy and another at a higher collision energy ramp (MSE). In this way, both protonated molecule and/or molecular ion together with fragment ions were obtained in a single run. Validation was performed according to SANCO/12571/2013 by analysing 20 samples (10 different commodities in duplicate), fortified with a test set of 132 pesticides at 0.01, 0.05 and 0.20 mg kg−1. For screening, the detection was based on one diagnostic ion (in most cases the protonated molecule). Overall, at the 0.01 mg kg−1 level, 89% of the 2620 fortifications made were detected. The screening detection limit for individual pesticides was 0.01 mg kg−1 for 77% of the pesticides investigated. The possibilities for identification according to the SANCO criteria, requiring two ions with a mass accuracy ≤±5 ppm and an ion-ratio deviation ≤±30%, were investigated. At the 0.01 mg kg−1 level, identification was possible for 70% of the pesticides detected during screening. This increased to 87% and 93% at the 0.05 and 0.20 mg kg−1 level, respectively. Insufficient sensitivity for the second ion was the main reason for the inability to identify detected pesticides, followed by deviations in mass accuracy and ion ratios.  相似文献   

10.
A laser can be used for the selective excitation and subsequent ionization of a molecule with an absorption band at the laser wavelength. This technique of multiphoton ionization (MPI), when combined with time-of-flight mass spectrometry (TOF-MS), permits the efficient detection of induced ions in mass analysis. This combination of MPI/TOF-MS can be coupled with gas chromatography (GC) to achieve even more enhanced selectivity. Thus, GC/MPI/TOF-MS can be employed for trace analysis of samples containing numerous chemical species. A variety of laser sources have been used for this purpose. Since molecules that are classified as environmental pollutants frequently contain chlorine and bromine atoms, the lifetime of the excited state can be decreased by energy transfer from the singlet to triplet levels by spin–orbit interaction. A high-power femtosecond laser with a pulse width shorter than the lifetime of the analyte molecule provides femtogram or even subfemtogram detection limits, which have not yet been achieved using the most sensitive high-resolution double-focus sector-type mass spectrometers. Numerous environmental pollutants such as dioxins in soils and pesticides in foods have been successfully quantified using GC/MPI/TOF-MS, and this technique has proven itself to be a useful and practical method for trace analysis.
Figure
Analytical instrument for laser ionization mass spectrometry  相似文献   

11.
A gas chromatography/mass spectrometry (GC/MS) method for determination of nine N-nitrosamines (NAs) in water is described. Two ionization modes, electron impact (EI) and chemical ionization (CI) with methanol, as well as different ion analysis techniques, i.e. full scan, selected ion storage (SIS) and tandem mass spectrometry (MS/MS) were tested. Chemical ionization followed by SIS resulted the mass spectrometric method of choice, with detection limits in the range of 1-2ng/L. Solid Phase Extraction (SPE) with coconut charcoal cartridges was applied to extract NAs from real samples, according EPA Method 521. Drinking water samples were collected from seven surface- and two groundwater treatment plants. Three surface water treatment plants were sampled before and after addition of O(3)/ClO(2) to observe the effect of disinfection on NAs' formation. N-nitrosodiethylamine (NDEA), n-nitrosodipropylamine (NDPA), n-nitrosomorpholine (NMOR) and n-nitrosodibutylamine (NDBA) were found up to concentrations exceeding three times the risk level of 10ng/L set by the California Department of Public Health. Because dermal adsorption has been recently indicated as a new contamination route of exposure to NAs for people who practice swimming activity, water samples from five swimming pools in the Bologna (Italy) area were collected. N-nitrosopyrrolidine (NPYR) was detected in all samples at concentrations larger than 50ng/L, likely as a disinfection by-product from the amino acid precursor proline, a main constituent of skin collagen.  相似文献   

12.
Shen CY  Cao XW  Shen WJ  Jiang Y  Zhao ZY  Wu B  Yu KY  Liu H  Lian HZ 《Talanta》2011,84(1):141-147
An analytical method with the technique of QuEChERS (quick, easy, cheap, effective, rugged and safe) and gas chromatography (GC)/mass spectrometry (MS) in negative chemical ionization (NCI) has been developed for the determination of 17 pyrethroid pesticide residues in troublesome matrices, including garlic, onion, spring onion and chili. Pyrethroid residues were extracted with acidified acetonitrile saturated by hexane. After a modified QuEChERS clean-up step, the extract was analyzed by GC-NCI/MS in selected ion monitoring (SIM) mode. An isotope internal standard of trans-cypermethrin-D6 was employed for quantitation. Chromatograms of pyrethroids obtained in all these matrices were relatively clean and without obvious interference. The limits of detection (LODs) ranged from 0.02 to 6 μg kg−1 and recovery yields were from 54.0% to 129.8% at three spiked levels (20, 40 and 60 μg kg−1 for chili, and 10, 20 and 30 μg kg−1 for others) in four different matrices depending on the compounds determined. The relative standard deviations (RSDs) were all below 14%. Isomerization enhancement of pyrethroids in chili extract was observed and preliminarily explained, especially for acrinathrin and deltamethrin.  相似文献   

13.
A multiresidue method for the determination of more than 80 pesticides in water has been developed and validated. The proposed method is based on SPE followed by GC coupled to MS/MS. Different variables affecting SPE procedure, such as cartridges, sample volume and solvents were studied, and mass spectrometric conditions were optimised in order to increase selectivity and sensitivity. Calibration curves were linear over the range of 0.03-0.5 microg/L. Recoveries were in the range of 70-110% and repeatability was below 20% for the lowest calibration point. LODs ranged from 0.001 to 0.025 microg/L and LOQs from 0.003 to 0.076 microg/L. Finally, the method was successfully applied to the analysis of water samples from southeast of Spain.  相似文献   

14.
Structural studies of the high molecular mass (HMM) glutenin subunits 1Bx7 (from cvs Hereward and Galatea) and 1Bx20 (from cv. Bidi17) of bread wheat were conducted using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and reversed-phase high-performance liquid chromatography/electrospray ionization mass spectrometry (RP-HPLC/ESI-MS). For all three proteins, MALDI-TOFMS analysis showed that the isolated fractions contained a second component with a mass about 650 Da lower than the major component. The testing and correction of the gene-derived amino acid sequences of the three proteins were performed by direct MALDI-TOFMS analysis of their tryptic peptide mixture. Analysis of the digest was performed by recording several MALDI mass spectra of the mixture at low, medium and high mass ranges, optimizing the matrix and the acquisition parameters for each mass range. Complementary data were obtained by RP-HPLC/ESI-MS analysis of the tryptic digest. This resulted in coverage of about 98% of the sequences. In contrast to the gene-derived data, the results obtained demonstrate the insertion of the sequence QPGQGQ between Trp716 and Gln717 of subunit 1Bx7 (cv. Galatea) and a possible single amino acid substitution within the T20 peptide of subunit 1Bx20. Moreover, the mass spectrometric data demonstrated that the lower mass components present in all the fractions correspond to the major components but lack about six amino acid residues, which are probably lost from the protein C-terminus. Finally, the results obtained provide evidence for the lack of glycosylation or other post-translational modifications of these subunits.  相似文献   

15.
N-(Dicyclohexyl)acetylpiperidine-4-benzylidene-4-carboxylic acid (1) is an excellent in vitro inhibitor of 5 alpha-reductase (5 alpha R). Compound 1 showed, however, much lower inhibition activity of 5 alpha R in vivo than in vitro, which might be caused by poor membrane permeability. The methyl ester of 1 (1a) was therefore tested as a model prodrug to see if it has better permeability properties than the corresponding acid 1. It was also monitored that this methyl ester was cleaved into the active compound 1 within the DU145 cells. Quantitative matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) methods were established with reliable linearity factors (0.996 for MALDI-TOFMS and 0.998 for HPLC/MS/MS) and reproducibility (relative standard deviation = 6.5% for MALDI-TOFMS and 2.8% for HPLC/MS/MS). The samples for MS analysis were effectively prepared from the cell homogenates using solid-phase extraction, with a high recovery of 90% on average. The intracellular amount of 1a (1.7 nmol) was much higher than that of 1 (0.032 nmol) in DU145 cells after 6 h of incubation. After incubation with the ester (1a), the cleaved acid (1) was detected within the cells. The concentration of acid 1 (0.045 nmol) in this experiment was higher than the acid content (0.032 nmol) after direct incubation with 1. Surprisingly, high amounts of the cleaved compound 1 were found outside the cells after 6 h of incubation with 1a.  相似文献   

16.
A sensitive and specific method for the determination of memantine in human plasma is presented. Memantine was extracted from plasma and derivatized to the pentafluorobenzoyl derivative in a one-step procedure avoiding any sample concentration steps. Amantadine was used as an internal standard. The compounds were measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further processing. Using this detection mode, the fragment ions at m/z 353 and 325 were obtained at high relative abundance. Calibration graphs were linear over the range 0.117-30 ng ml(-1). At the limit of quantification (LOQ), the inter-assay precision was 2.00% and the intra-assay variability was 3.22%. The accuracy at the LOQ showed deviations of -1.42% (intra-assay) and -2.47% (inter-assay). The method is rugged, rapid and robust and was applied to the batch determination of memantine during pharmacokinetic profiling of the drug.  相似文献   

17.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was used in conjunction with size exclusion chromatography (SEC) to investigate a model polyester system based on phthalic anhydride–1,2-propylene glycol. The polyesters were synthesized with a 30% molar excess of glycol, with kinetic samples being removed during different intervals of the polyesterification reaction. SEC was used to track the course of the reaction by determining the molecular weight and molecular weight distributions before subsequent off-line coupling with MALDI-TOF MS as a selective detection method to determine the chemical composition, identify the functionality type distributions as well as assist in assigning structural conformations. Mass spectrometry analysis proved to be a highly effective tool to facilitate the identification of the narrowly dispersed fractions obtained from the chromatographic separations as well as serve as a core method to investigate the heterogeneous nature of the bulk kinetic samples. Through the hyphenation of these sophisticated polymer characterization techniques, information on the molecular heterogeneity of the model polyesters, showing a complex variety of possible distributions, was obtained.  相似文献   

18.
Two model peptides, des-Arg1-bradykinin (DAB) and bradykinin (B), were cationized by Ag+ after their separation by reversed-phase liquid chromatography (RPLC) prior to mass spectrometry (MS). Silver nitrate solution was used as a post-column reagent. The RPLC and MS experimental conditions were optimized using flow injection in order to obtain sufficiently abundant silver adducts to permit MS/MS experiments. The use of water-methanol with 0.1% formic acid as mobile phase allowed a good chromatographic separation of the two peptides with a polymeric stationary phase and sufficiently abundant silver-containing adducts, [M + Ag + H]2+ and [M + 2Ag]2+. The gas-phase dissociation of [DAB + Ag + H]2+ and [DAB + 2Ag]2+ led to interpretable mass spectra during the on-line cationization experiment. Most of the ions obtained by dissociating [DAB + Ag + H]2+ and [DAB + 2Ag]2+ species are silver-containing ions but the ions produced depend on the parent. The ions coming from the dissociation of the doubly charged silver adducts [DAB + Ag + H]2+ or [DAB + 2Ag]2+ are of interest compared with those coming from the singly charged silver species or doubly charged protonated species. The fragmentation of the doubly charged silver adducts provides ions over the entire mass range. Although the presence of several prolines in des-Arg1-bradykinin prevents the formation of some expected ions, the observation of triplets [an-H + Ag]+, [bn-H + Ag]+ and [bn + OH + Ag]+ produced by the dissociation of on-line Ag(+)-cationized peptides could contribute to greater success of automatic sequencing of peptides.  相似文献   

19.
Summary Liquid chromatography-mass spectrometry (LC-MS) with atmospheric pressure chemical ionization (APCI), and gas chromatography-mass spectrometry (GC-MS) with electron impact ionization (EI), are compared for the determination of eight pesticides in oranges. Seven of the selected pesticides, chlorpyriphos, chlorpyriphos-methyl, imazalil, α and β-endosulfan, endosulfan sulphate and dicofol, are commonly determined by GC whereas one, thiabendazole, can only be directly determined by LC. Primary ions [M-H] or [M-Cl+O] are obtained using LC-APCI-MS in negative ionization (NI) mode. In contrast, a high degree of fragmentation is reported with GC-MS. Both techniques were applied to oranges, which had been previously extracted with ethyl acetate and anhydrous sodium sulphate. The data indicate equivalent detection limits that range from 0.01 to 0.1 mgkg−1 and similar degree of specificity. Mean recoveries ranged from 82% for α-endosulfant to 96% for imazalil, with relative standard deviation ranging from 7 to 17%.  相似文献   

20.
Two different analytical approaches, direct exposure electron ionization mass spectrometry (DE-MS) and gas chromatography/mass spectrometry (GC/MS), were compared in a study of archaeological resinous materials. DE-MS was found to be an efficient fingerprinting tool for the fast screening of organic archaeological samples and for providing information on the major components. GC/MS appeared to be more efficient in unravelling the sample composition at a molecular level, despite the long analysis time and the need for a wet chemical pretreatment. Both procedures were applied to characterize the organic material present as coatings in Roman and Egyptian amphorae. DE-MS successfully identified abietanic compounds, hence a diterpenic resinous material could be identified and its degree of oxidation assessed. GC/MS enabled us to identify dehydroabietic acid, 7-oxodehydroabietic acid, 15-hydroxy-7-oxodehydroabietic acid, 15-hydroxydehydroabietic acid, retene, tetrahydroretene, norabietatriene, norabietatetraene and methyl dehydroabietate. These oxidized and aromatized abietanes provided evidence that the amphorae examined were waterproofed with a pitch produced from resinous wood of plants from the Pinaceae family. The chemometric evaluation of the GC/MS data highlighted significant chemical differences between the pitches found in the two archaeological sites, basically related to differences in the production techniques of the materials and in their degradation pathways.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号