首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Canagliflozin is a newly approved drug for type II diabetes mellitus. A full stability study of canagliflozin was performed following international conference on harmonization strategies. The drug was stable against all conditions except oxidation where only one degradation product was separated and structurally elucidated using mass spectrometry and infrared spectroscopy. A green high‐performance thin‐layer chromatographic densitometric determination was developed and validated for the accurate quantification of canagliflozin and its main oxidative degradation product. Separation was performed on high‐performance aluminum plates precoated with silica gel using acetone/ethanol (80:20, v/v) as a developing system and scanning at 290 nm. Retardation factor values were 0.64 and 0.81 and linearity ranges were 0.4–3.6 and 0.2–3.2 μg/band for the drug and the degradation product, respectively. It was a matter of interest to use green solvents with no harmful effects on the environment. The comparison between the proposed and the reported high‐performance liquid chromatography method regarding greenness profile showed that the proposed method was greener and so could be used as an alternative method to the reported one with no environmental harm. Method validity was tested as per international conference on harmonization and method utility was verified by application to Invokana® tablets.  相似文献   

2.
Clenbuterol screening of bovines is done by analysis of urine, for monitoring living animals, and liver, for monitoring animals after slaughter. ELISA has generally been used as the main method for these purposes. Nevertheless, in Europe, methods must be validated according to Commission Decision (EC) 657/2007 criteria, i.e. by use of reference materials. Production of “in house” reference materials is a possibility, but the homogeneity, storage temperature, and period of stability of these materials must be investigated in the laboratory itself. This paper reports GC–MS evaluation of an “in-house”-produced batch of aliquots of bovine urine and liver, fortified with 10.0 ng/ml and 10.0 ng/g clenbuterol, respectively, and stored at ?20 °C and at ?60 °C. For urine stored for 20 weeks at ?20 °C and at 60 °C the stability of clenbuterol was proved at the 95% confidence level. For liver, however, it was demonstrated at the same confidence level that clenbuterol was highly unstable during storage for 20 weeks at either of the temperatures studied.  相似文献   

3.
This paper presents a general screening method, based on liquid chromatography/mass spectrometry (LC/MS), for the simultaneous detection in human urine of 72 xenobiotics (21 diuretics, 16 synthetic glucocorticoids, 17 beta-adrenergic drugs, 10 stimulants, 5 anti-oestrogens and 3 anabolic steroids), excreted free or as glucuro-conjugates in urine. Although the method has been specifically designed and evaluated in view of its potential application to anti-doping analyses, it can also be effective in other areas of analytical toxicology. Sample preparation was based on two liquid/liquid separation steps (performed at alkaline and at acid pH, respectively) of hydrolyzed human urine, and then an assay by LC/MS-MS in positive and negative ionization mode using an electrospray ionization source (ESI) and multiple reaction monitoring (MRM) as the acquisition mode. The overall time needed for an LC run was less than 15 minutes. All compounds showed good reproducibility in terms of both the retention times (CV%<1) and the relative abundances of the diagnostic transitions (CV%<10). The limits of detection (LOD) were in the range of 1–50 ng/mL for glucocorticoids, anti-oestrogens and steroids, and 50–500 ng/mL for diuretics, beta-adrenergic drugs and stimulants, thus satisfying the minimum required performance limits (MRPL) set by the World Anti-Doping Agency (WADA) for the accredited anti-doping laboratories.  相似文献   

4.
Within the scope of research for target and non-target LC–MS/MS analysis of membrane degradation products of polymer electrolyte membrane fuel cells, a systematic method development for the separation of structurally similar compounds was performed by phase optimized liquid chromatography. Five different stationary phases with different selectivities were used. Isocratic separation for 4-hydroxybenzoic acid, isophthalic acid, terephthalic acid, 4-hydroxybenzaldehyde and 4-formylbenzoic acid was achieved on a C18 and a Phenyl phase. Using the PRISMA model the separation efficiency was optimized. This was achieved on a serially connected mixed stationary phase composed of 30 mm C18, 150 mm Phenyl and 60 mm C30. For the LC–MS screening of unknown degradation products from polymer electrolyte membranes in the product water of a fuel cell, a solvent gradient is mandatory for less polar or later eluting compounds. By means of 4-mercaptobenzoic acid it could be shown that a solvent gradient can be applied in order to elute later eluting compounds in a short time. The adaptability of this method for the qualitative analysis by target and non-target LC–MS/MS screening has been shown by means of 4-hydroxybenzoic acid. The combination of solvent gradient and isocratic conditions makes this approach attractive for the purpose of a screening method for known and unknown analytes in a water sample.  相似文献   

5.
6.
The development of a simple and sensitive analytical approach that combines multiple monolithic fiber solid‐phase microextraction with liquid desorption followed by high‐performance liquid chromatography with diode array detection is proposed for the determination of trace levels of seven steroid sex hormones (estriol, 17β‐estradiol, testosterone, ethinylestradiol, estrone, progesterone and mestranol) in water and urine matrices. To extract the target analytes effectively, multiple monolithic fiber solid‐phase microextraction based on a polymeric ionic liquid was used to concentrate hormones. Several key extraction parameters including desorption solvent, extraction and desorption time, pH value and ionic strength in sample matrix were investigated in detail. Under the optimal experimental conditions, the limits of detection were found to be in the range of 0.027–0.12 μg/L. The linear range was 0.10–200 μg/L for 17β‐estradiol, 0.25–200 μg/L estriol, ethinylestradiol and estrone, and 0.50–200 μg/L for the other hormones. Satisfactory linearities were achieved for analytes with the correlation coefficients above 0.99. Acceptable method reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations of both less than 8%. The enrichment factors ranged from 54‐ to 74‐fold. Finally, the proposed method was successfully applied to the analysis of steroid sex hormones in environmental water samples and human urines with spiking recoveries ranged from 75.6 to 116%.  相似文献   

7.
A stability‐indicating reverse‐phase high‐performance liquid chromatography–mass spectrometric method was developed and validated for the assay of metaxalone through forced degradation under acidic, alkaline, photo, oxidative and peroxide stress conditions. Separation of degradation products was accomplished on a reverse‐phase Phenomenex C18 (250 × 4.6 mm, 5 µm) column thermostated at 25°C using 10 mM aqueous ammonium acetate: methanol (35:65 v/v) as mobile phase in an isocratic mode of elution. The eluents were detected at 275 nm by photo diode array detector and mass detectors connected in series. Two unknown base hydrolysis products of metaxalone were identified and characterized as (a) methyl 3‐(3,5‐dimethylphenoxy)‐2‐hydroxypropylcarbamate and (b) 1‐(3,5‐dimethylphenoxy)‐3‐aminopropan‐2‐ol by MS, 1H NMR and FTIR spectroscopy. The method was validated as per International Conference on Harmonization guidelines and metaxalone was selectively determined in presence of its degradation impurities, demonstrating its stability‐indicating nature. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
The gas chromatography mass spectrometry (GC–MS) deconvolution reporting software (DRS) from Agilent Technologies has been evaluated for its ability as a screening tool to detect a large number of pesticides in incurred and fortified samples extracted with acetone/dichloromethane/light petroleum (Mini-Luke method). The detection of pesticides is based on fixed retention times using retention time locking (RTL) and full scan mass spectral comparison with a partly customer built automated mass spectral deconvolution and identification system (AMDIS) database. The GC–MS was equipped with a programmable temperature vaporising (PTV) injector system which enables more sample to be injected. In a blind study of 52 real samples a total number of 158 incurred pesticides were found. In addition to the 85 pesticides found by manual interpretation of GC–NPD/ECD chromatograms, the DRS revealed 73 more pesticides (+46%). The DRS system also shows its potential to discover pesticides which are normally not searched for (EPN in long beans from Thailand). A spiking experiment was performed to blank matrices of apple, orange and lettuce with 177 different pesticides at concentration levels 0.02 and 0.1 mg/kg. The samples were analysed on GC–MS full scan and the AMDIS match factor was used as a mass spectral quality criterion. The threshold level of the AMDIS match factor was set at 20 to eliminate most of the false positives. AMDIS match factors from 20 up to 69 are regarded only as indication of a positive hit and must be followed by manual interpretation. Pesticides giving AMDIS match factors at ≥70 are regarded as identified. To simplify and decrease the large amount of data generated at each concentration level, the AMDIS match factors ≥20 was averaged (mean AMF) for each pesticide including the commodities and their replicates. Among 177 different pesticides spiked at 0.02 and 0.1 mg/kg level, the percentage of mean AMF values ≥70 were 23% and 80%, respectively. For 531 individual detections of pesticides (177 pesticides × 3 replicates) giving AMDIS match factor 20 in apple, orange and lettuce, the detection rates at 0.02 mg/kg were 71%, 63% and 72%, respectively. For the 0.1 mg/kg level the detection rates were 89%, 85% and 89%, respectively. In real samples some manual interpretation must be performed in addition. However, screening by GC–MS/DRS is about 5–10 times faster compared to screening with GC–NPD/ECD because the time used for manual interpretation is much shorter and there is no need for re-injection on GC–MS for the identification of suspect peaks found on GC–NPD/ECD.  相似文献   

9.
This study proposes a new approach to the optimization of the extraction of the volatile fraction of plant matrices using the headspace solid-phase microextraction (HS-SPME) technique. The optimization focused on the extraction time and temperature using a CAR/DVB/PDMS 50/30 μm SPME fiber and 100mg of a mixture of plants as the sample in a 15-mL vial. The extraction time (10-60 min) and temperature (5-60 °C) were optimized by means of a central composite design. The chromatogram was divided into four groups of peaks based on the elution temperature to provide a better understanding of the influence of the extraction parameters on the extraction efficiency considering compounds with different volatilities/polarities. In view of the different optimum extraction time and temperature conditions obtained for each group, a new approach based on the use of two extraction temperatures in the same procedure is proposed. The optimum conditions were achieved by extracting for 30 min with a sample temperature of 60 °C followed by a further 15 min at 5 °C. The proposed method was compared with the optimized conventional method based on a single extraction temperature (45 min of extraction at 50 °C) by submitting five samples to both procedures. The proposed method led to better results in all cases, considering as the response both peak area and the number of identified peaks. The newly proposed optimization approach provided an excellent alternative procedure to extract analytes with quite different volatilities in the same procedure.  相似文献   

10.
The proposed research, presents the synthesis, characterization, and photocatalytic accomplishment of ZnO nanoplate (ZnOs) modified with activated carbon derived from Konar bark. The obtained nanocomposite (photocatalyst) was characterized by scanning electron microscopy (SEM), X‐ray diffraction (XRD), Raman spectroscopy, X‐ray photoelectron spectroscopy (XPS), and Brunauer–Emmett–Teller (BET). First, the ZnO photocatalyst and activated carbon (AC) were prepared separately; then, the ZnO photocatalyst was modified with activated carbon. Various parameters namely pH, degradation time, and photocatalyst dose were optimized and studied in multivariate method by design expert7 software. The synergic efficiency of ZnO‐AC (adsorbent/photocatalyst) exhibited a good rate of ciprofloxacin (CIP) removal under visible irradiation. In addition, first pseudo order kinetic and isotherms equations were calculated. Moreover, the identification of degradation products was performed by ultra performance liquid chromatography‐tandem mass spectrometer (UPLC‐MS/MS). It is for the first time that a ZnO photocatalyst modified with activated carbon (ZnO‐AC) applied for CIP degradation.  相似文献   

11.
《Analytical letters》2012,45(1):18-28
A simple and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous analysis of three tropane alkaloids in blood and urine. After 1 mL of a blood or urine sample was extracted using a liquid–liquid extraction method with ethyl acetate at pH 8 and homatropine as the internal standard, the tropane alkaloids were separated. An Allure PFP propyl column (50 mm × 2.1 mm, 5 µm) separated the tropane alkaloids using an acetonitrile-buffer solution (20 mmol/L ammonium acetate and 0.1% formic acid, pH 4) (70:30) as the mobile phase at a flow-rate of 0.2 mL/min in isocratic mode, with the LC-MS/MS in the positive ionization mode. For each compound, detection was related to two daughter ions (scopolamine: m/z 304.4 → 138.1 and 155.9; atropine: m/z 290.3 → 124.0 and 93.1; anisodamine: m/z 306.3 → 140.1 and 91.1; and homatropine: m/z 276.3 → 124.3 and 142.1). The tropane alkaloids exhibited excellent linearity in the range of 0.05–100 ng/mL in blood and 0.2–100 ng/mL in urine, with a limit of detection range from 0.02 to 0.05 ng/mL for biological materials. The extraction recoveries of atropine, scopolamine, and anisodamine were more than 53% in the blood and urine; the interday and intraday RSDs were less than 10%; the within-day and between-day accuracy were between ?9.8% and +8.8%. The present method is simple and rapid, as shown by its application to a clinical case. This method is useful for routine analysis of tropane alkaloids in cases of suspected tropane alkaloid poisoning.  相似文献   

12.
Notoginsenoside Fc, a protopanaxadiol‐type saponin, shows multi‐pharmacological activities. Chemical stability evaluation plays a crucial role in drug development. In this study, the forced degradation behavior of Notoginsenoside Fc was investigated under hydrolytic and oxidative conditions. A specific ultra high performance liquid chromatography with quadrupole time‐of‐flight mass spectrometry was developed for the separation, identification, and characterization of the degradation products of Notoginsenoside Fc. Fifty potential degradation products were formed via deglycosylation, dehydration, hydration, isomerization, side‐chain cleaving, oxidation, and superoxidation. Notoginsenoside Fc was subjected to different pH solutions, temperatures, and time periods to assess its stability. A sensitive ultra high performance liquid chromatography‐tandem mass spectrometry was developed for the quantification of Notoginsenoside Fc, notoginsenoside ST‐4, notoginsenoside Ft1, and relative quantification of notoginsenoside Ft2, 20(R)‐notoginsenoside Ft2, notoginsenoside SFt3, and notoginsenoside SFt4. The assay was linear over the concentration range (R> 0.997) with the lowest limit of quantification of 0.02 μg/mL for Notoginsenoside Fc, Notoginsenoside ST‐4, and Notoginsenoside Ft1. The intra‐day precision, inter‐day precision, and accuracy of the three analytes were within accepted levels. The degradation kinetics of Notoginsenoside Fc in pH 1 and 3 solutions fits to first‐ and second‐order kinetics, respectively. The degradation of Notoginsenoside Fc is pH‐, temperature‐, and time‐dependent.  相似文献   

13.
A method of detecting and quantifying dehydroepiandrosterone (DHEA) sulfate, corticosteroids, and androgens has been developed. All of the compounds were first extracted from urine using solid phase extraction (SPE), enzymatically hydrolyzed, and separated into three samples using a second SPE. A DHEA sulfate sample was acetylated and re-extracted using SPE for purification before analysis. Corticosteroid samples were oxidized and re-extracted using liquid/liquid extraction for analysis. Androgen samples were acetylated and re-extracted using SPE prior to analysis. The extraction and analysis methods were investigated and optimized. Analyses were performed with gas chromatography/mass spectrometry (GC/MS) and gas chromatography/flame ionization detection (GC/FID). The entire procedure was then applied to the study of urine profiles of healthy volunteers and patients treated with corticosteroids. The results showed that the quantities of androgens found in patient urines were lower than in those of healthy volunteers. In addition, other metabolites were detected in patient urines.  相似文献   

14.
A capillary zone electrophoresis (CZE) method with ultraviolet-visible detection has been established and validated for the determination of five phenothiazines: thiazinamium methylsulfate, promazine hydrochloride, chlorpromazine hydrochloride, thioridazine hydrochloride, and promethazine hydrochloride in human urine. Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using a buffer containing 150 mM tris(hydroxymethyl)aminomethane and 25% acetonitrile at pH 8.2, with temperature and voltage of 25 degrees C and 20 kV, respectively. Naphazoline hydrochloride was used as an internal standard. Field-amplified sample injection (FASI) has been applied to improve the sensitivity of the detection. Considering the influence of parameters affecting the on-line preconcentration (nature of preinjection plug, sample solvent composition, injection times, and injection voltage) and due to the significant interactions among them, in this paper we propose for the first time the application of a multivariate approach to carry out the study. The optimized conditions were as follows: preinjection plug of water for 7 s at 50 mbar, electrokinetic injection for 40 s at 6.2 kV, and 32 microm of H3PO4 in the sample solvent. Also, a solid-phase extraction (SPE) procedure is developed to obtain low detection limits and an adequate selectivity for urine samples. The combination of SPE and FASI-CZE-UV allows adequate linearities and recoveries, low detection limits (from 2 to 5 ng/mL), and satisfactory precisions (3.0-7.2% for an intermediate RSD %).  相似文献   

15.
Fabric phase sorptive extraction (FPSE) is a new, yet very promising member of the sorbent-based sorptive microextraction family. It has simultaneously improved both the extraction sensitivity and the speed of the extraction by incorporating high volume of sol–gel hybrid inorganic–organic sorbents into permeable fabric substrates. The advantages of FPSE have been investigated for the determination of four non-steroidal anti-inflammatory drugs, ibuprofen, naproxen, ketoprofen and diclofenac, in environmental water samples in combination with gas chromatography–mass spectrometry. Initially, the significance of several parameters affecting FPSE: sorbent chemistry, matrix pH and ionic strength were investigated using a mixed level factorial design (31 × 22). Then, other important parameters e.g., sample volume, extraction kinetics, desorption time and volume were also carefully studied and optimized. Due to the high sorbent loading on the FPSE substrate in the form of ultra-thin coating and the open geometry of the microextraction device, higher mass transfer of the target analytes occurs at a faster rate, leading to high enrichment factors in a relatively short period of time (equilibrium times: 45–100 min). Under optimal operational conditions, the limits of detection (S/N = 3) were found to be in the range of 0.8 ng L−1 to 5 ng L−1. The enrichment factors ranged from 162 to 418 with absolute extraction efficiencies varied from 27 to 70%, and a good trueness (82–116% relative recoveries) indicating that the proposed method can be readily deployed to routine environmental pollution monitoring. The proposed method was successfully applied to the analysis of target analytes in two influent and effluent samples from a wastewater treatment plant and two river water samples in Spain.  相似文献   

16.
A validated stability‐indicating HPLC method was established, and comprehensive stress testing of ivabradine, a cardiotonic drug, was carried out as per ICH guidelines. Ivabradine was subjected to acidic, basic and neutral hydrolysis, oxidation, photolysis and thermal stress conditions, and the resulting degradation products were investigated by LC‐PDA and LC‐HR‐MS/MS. The drug was found to degrade in acid and base hydrolysis. An efficient and selective stability assay method was developed on Phenomenex Luna C18 (250 × 4.6 mm, 5.0 µm) column using ammonium formate (10 mM, pH 3.0) and acetonitrile as mobile phase at 30 °C in gradient elution mode. The flow rate was 0.7 ml/min and detection wavelength was 286 nm. A total of five degradation products (I‐1 to I‐5) were identified and characterized by LC‐HR‐MS/MS in combination with accurate mass measurements. The drug exhibited different degradation behaviour in HCl and H2SO4 hydrolysis conditions. It is a unique example where two of the five degradation products in HCl hydrolysis were absent in H2SO4 acid hydrolysis. The present study provides guidance to revise the stress test for the determination of inherent stability of drugs containing lactam moiety under hydrolytic conditions. Most probable mechanisms for the formation of degradation products have been proposed on the basis of a comparison of the fragmentation pattern of the drug and its degradation products. In silico toxicity revealed that the degradation products ( I‐2 to I‐5 ) were found to be severe irritants in case of ocular irritancy. The analytical assay method was validated with respect to specificity, linearity, range, precision, accuracy and robustness. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
An ion mobility spectrometer equipped with an ultraviolet lamp was used for the qualitative and quantitative determination of acetone in urine samples. This analyte can be used as a biomarker for some fat metabolism-related diseases in humans and cows. Samples require no pretreatment other than warming at 80 °C for 5 min, after which an N2 stream is used to drive volatile analytes to the ion mobility spectrometer. The precision of the ensuing method, expressed as relative standard deviation (%RSD), is better in all cases than 6.7% for peak height and calculated at three levels of concentration. The analyte concentration range studied was from 5 to 80 mg L−1, its limit of detection in the aqueous matrix 3 mg L−1 and recoveries from spiked urine samples 109 ± 3%. The calculated reduced mobility for acetone in the urine samples, 1.75 ± 0.04 cm2 V−1 s−1, was similar to previously reported values. Also, the results were consistent with those provided by test strips used for reference. The proposed method provides a new vanguard screening system for determining acetone in urine samples.  相似文献   

18.
Stimulants are banned by the World Anti-Doping Agency (WADA) if used “in competition”. Being the analysis of stimulants presently carried out on urine samples only, it might be useful, for a better interpretation of analytical data, to discriminate between an early intake of the substance and an administration specifically aimed to improve the sport performance. The purpose of the study was to investigate the differences, in terms of excretion/disappearance of drugs, between urine and oral fluid, a sample that can reflect plasmatic concentrations.Oral fluid and urine samples were collected following oral administration of the following stimulants: modafinil (100 mg), selegiline (10 mg), crotetamide/cropropamide (50 mg each), pentetrazol (100 mg), ephedrine (12 mg), sibutramine (10 mg), mate de coca (a dose containing about 3 mg of cocaine); analysis of drugs/metabolites was carried out by gas chromatography/mass spectrometry (GC/MS) in both body fluids.Our results show that both the absolute concentrations and their variation as a function of time, in urine and in oral fluid, are generally markedly different, being the drugs eliminated from urine much more slowly than from oral fluid. Our results also suggest that the analysis of oral fluid could be used to successfully complement the data obtained from urine for “in competition” anti-doping tests; in all those cases in which the metabolite(s) concentration of a substance in urine is very low and the parent compound is not detected, it is indeed impossible, relying on urinary data only, to discriminate between recent administrations of small doses and remote administrations of higher doses.  相似文献   

19.
Salbutamol is commonly used in asthma treatment, being considered a short‐effect bronchodilator. This drug poses special interest in certain fields of chemical analysis, such as food, clinical and doping analyses, in which it needs to be analyzed with quantitative precision and accuracy. Salbutamol, however, is known to degrade under certain conditions and this is critical if quantitative results must be generated. The present work aimed to investigate salbutamol extraction from urine samples, to determine whether salbutamol is unstable in other solvents as well as in urine samples, to elucidate the structures of the possible degradation products and to validate an analytical method using the extraction procedure evaluated. Stability investigations were performed in urine at different pH values, in methanol and acetone at different temperatures. Semi‐preparative liquid chromatography was performed for the isolation of degradation products, and gas chromatography coupled to mass spectrometry as well as nuclear magnetic resonance were used for identification. Three unreported methylation products were detected in methanolic solutions and had their structures elucidated. Urine samples showed a reduction in salbutamol concentration of up to 25.8% after 5 weeks. These results show that special care must be taken regarding salbutamol quantitative analyses, since degradation either in standard solutions or in urine could lead to incorrect values. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents a capillary electrophoresis method, developed for the detection, in human urine, of beta‐adrenergic agents and phenolalkylamines. The electrophoretic separation is achieved in less than 10 min and is based on the use of CEofix kit, for the dynamic capillary coating. The effects of accelerator buffer pH and separation voltage were investigated. The optimum buffer pH was found to be 2.5 for beta2‐agonists and 6.2 for beta‐blockers and phenoalkylamines with a separation voltage of 15 kV. Urine samples spiked with the compounds here studied were treated according to the standard procedure (SPE and evaporation to dryness) and analyzed by CE interfaced with an UV diode‐array, set at 195 and 210 nm. The quantitative validation results, obtained analyzing samples at three different concentrations, show a good precision of peak areas that do not exceed 5% for intra‐day assays and 10% for inter‐day assays. Good linearity (r2 > 0.995) was obtained within the 50–500 ng/mL concentration range. The qualitative validation data show a relative migration times (MTs) variation lower than 1%. The analytes were clearly distinguishable in urine, with LOD and LOQ in the range of 10–80 and 40–100 ng/mL, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号