首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
An off-line column preconcentration technique using a micro-column of 2,6 diacetylpyridine functionalized Amberlite XAD-4 with inductively coupled plasma mass spectrometry (ICP-MS) as a means of detection has been developed. The aim of the method was to determine rare earth elements (REEs) (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) in seawater. Sample solutions (2–10 mL) were passed through the column which was then washed with ultra-pure water to remove residual matrix. The adsorbed cations on the resin were eluted by using 2 mL of 0.1 mol L−1 HNO3 containing 10 ng mL−1 indium as an internal standard. The eluent was analyzed for the metal concentrations using ICP-MS. Sample pH as well as the sample and eluent flow rates were optimized. The sorption capacity of resin was determined by the batch process, by equilibrating 0.05 g of the resin with solutions of 50 mL of 25 mg L−1 of individual metal ions for 4 h at pH 6.0 at 26 °C. The sorption capacities for the resin were found to range between 47.3 μmol g−1 (for Lu) and 136.7 μmol g−1 (for Gd). Limits of detection (3σ), without any preconcentration, ranged from 2 ng L−1 to 10.3 ng L−1 (for Tm and Lu respectively). The proposed method was applied to the determination of REEs in seawater and tap water samples.  相似文献   

2.
A simple and sensitive method for the determination of dimethylsulfide (DMS) and dimethylselenide (DMSe) employing a gas chromatograph–photoionization detector with headspace sampling (HS-GC-PID) was developed. Parameters affecting the HS-GC-PID sensitivity including matrix effect, heating temperature, extraction time and carrier gas flow-rate were optimized. The matrix effect was required for standard addition calibration method for quantification purposes. The method has been validated when rectilinear relationship was between the concentrations of analytes and peak area in the range of 0.2–50 ng mL− 1 for DMSe and 0.5–100 ng mL− 1 for DMS, the correlation coefficients were from 0.995–0.998, and the limits of detection for DMS and DMSe were 25 pg mL− 1 and 48 pg mL− 1, respectively. The proposed method was further applied to quantification of DMS and DMSe in urine samples.  相似文献   

3.
In the present study, a three phase-based hollow fiber protected liquid-phase microextraction (HF-LPME) method combined with high-performance liquid chromatography (HPLC) for the determination of salicylates in environmental waters was developed. The HF-LPME procedure was optimized by an L16(45) orthogonal array experimental design (OAD) with five factors at four levels. Under the optimal extraction condition (pHs of donor and receiving phases of 3.0 and 6.2, respectively, extraction time of 45 min, stirring speed of 1000 rpm, and salt addition of 20% (w/v)), salicylates could be determined in a linear range from 0.025 to 1.0 μg mL−1 with a good correlation (r2 > 0.9930). The limits of detection (LODs) ranged between 0.6 ng mL−1 and 1.2 ng mL−1 for the target analytes. The relative standard deviations (RSDs) of intra-day and inter-day were in the range of 0.64–14.58% and 0.16–15.45%, respectively. This procedure afforded a convenient, sensitive, accurate and cost-saving operation with high extraction efficiency for the model analytes. The method was applied satisfactorily to the determination of salicylates in two environmental waters.  相似文献   

4.
A sensitive competitive flow injection chemiluminescence (CL-FIA) immunoassay for immunoglobulin G (IgG) was developed using gold nanoparticle as CL label. In the configuration, anti-IgG antibody was immobilized on a glass capillary column surface by 3-(aminopropyl)-triethoxysilane and glutaraldehyde to form immunoaffinity column. Analyte IgG and gold nanoparticle labeled IgG were passed through the immunoaffinity column mounted in a flow system and competed for the surface-confined anti-IgG antibody. CL emission was generated from the reaction between luminol and hydrogen peroxide in the presence of Au (III), generated from chemically oxidative dissolution of gold nanoparticle by an injection of 0.10 mol L−1 HCl–0.10 mol L−1 NaCl solution containing 0.10 mmol L−1 Br2. The concentration of analyte IgG was inversely related to the amount of bound gold nanoparticle labeled IgG and the CL intensity was linear with the concentration of analyte IgG from 1.0 ng mL−1 to 40 ng mL−1 with a detection limit of 5.2 × 10−10 g mL−1. The whole assay time including the injections and washing steps was only 30 min for one sample, which was competitive with CL immunoassays based on a gold nanoparticle label and magnetic separation. This work demonstrates that the CL immunoassay incorporation of nanoparticle label and flow injection is promising for clinical assay with sensitivity and high-speed.  相似文献   

5.
The sublingual combination of buprenorphine and naloxone (Suboxone®) and Methadone Maintenance Therapy have been found effective in treating heroin addiction. A new analytical method suitable for the simultaneous determination of buprenorphine, norbuprenorphine, methadone and naloxone in human plasma by means of liquid chromatography with coulometric detection has been developed. The chromatographic separation was achieved with a phosphate buffer–acetonitrile mixture as the mobile phase on a cyano column. The monitoring cell of the coulometric detector was set at an oxidation potential of +0.600 V. A rapid clean-up procedure of the biological samples using a microextraction by packed sorbent technique has been implemented, employing a C8 sorbent inserted into a syringe needle. The extraction yield values were satisfactory for all analytes (>85%). The calibration curves were linear over a range of 0.25–20.0 ng mL−1 for buprenorphine and norbuprenorphine, 3.0–1000.0 ng mL−1 for methadone and 0.13–10.0 ng mL−1 for naloxone. The sensitivity was also high with limits of detection of 0.08 ng mL−1 for both buprenorphine and norbuprenorphine, 0.9 ng mL−1 for methadone and 0.04 ng mL−1 for naloxone. The intraday and interday precision data were always satisfactory.The method was successfully applied to plasma samples obtained from former heroin addicts treated with opioid replacement therapy.  相似文献   

6.
The effect of silver colloidal nanoparticles (AgNPs) on the luminol–isoniazid system was investigated. It was found that AgNPs could act as a nanocatalyst on the luminol–isoniazid system to generate chemiluminescence (CL). The CL emission spectrum of the luminol–isoniazid–AgNPs system showed a peak with a maximum at 425 nm. It was suggested that the luminophor species was the excited state 3-aminophthalate. The reduction of dissolved O2 to H2O2 by isoniazid and decomposition of H2O2 to the oxygen-related radicals were attributed to the catalytic effect of AgNPs. Under optimized conditions, the CL signal intensity was linear with the isoniazid concentration in the range of 10–1000 ng mL− 1, with the correlation coefficient of 0.9996. The limit of detection was 2.7 ng mL− 1 isoniazid. The relative standard deviations for seven repeated measurements of 60 and 200 ng mL− 1 isoniazid were 1.4 and 2.4%, respectively. The effect of potent interfering compounds on the CL signal intensity of the proposed luminol–isoniazid–AgNPs system was investigated. The proposed method was successfully applied to the determination of isoniazid in a pharmaceutical sample.  相似文献   

7.
An analytical method for the quantification of thyroid hormones (3,5,3′,5′-tetraiodo-l-thyronine, 3,3′,5-triiodo-l-thyronine, 3,3′,5′-triiodothyronine, 3,5-diiodothyronine, 3,3′-diiodothyronine) in different water matrices has been developed. The method, consisting of solid phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS/MS), was validated for tap and surface water as well as raw and treated waste water. The limits of quantifications (LOQs) were lowest in tap water, where they ranged from 1.1 to 13.3 ng L−1, and highest in raw wastewater (10.5–84.9 ng L−1). Of the target analytes 3,5,3′,5′-tetraiodo-l-thyronine (T4) could be quantified in the influent and effluent of a waste water treatment plant (WWTP) in Finland. The study showed that despite a relatively high removal rate during treatment (66%), part of the incoming T4 will reach the aquatic environment and, due to the high endocrine activity of this compound, further studies are needed in order to assess its environmental fate and impact on natural ecosystems.  相似文献   

8.
A new type of composite material based on carbon nanotubes (CNTs) and sol–gel chemistry was prepared and used as sorbent for needle trap device (NTD). The synthesized composite was prepared in a way to disperse CNTs molecules in a sol–gel polymeric network. CNT/silica composites with different CNT doping levels were successfully prepared, and the extraction capability of each composite was evaluated. Effects of surfactant and the oxidation duration of CNTs on the extraction efficiency of synthesized composites were also investigated. The applicability of the synthesized sorbent was examined by developing a method based on needle trap extraction (NTE) and gas chromatography mass spectrometry detection (GC–MS) for the determination of polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Important parameters influencing the extraction process were optimized and an extraction time of 30 min at 50 °C and sampling flow rate of 2.5 mL min−1 gave maximum peak area, when NaCl (15%, w/v) was added to the aqueous sample. The linearity for acenaphthene, acenaphthylene and fluorene was in the concentration range of 0.01–20 ng mL−1 and for naphthalene and anthracene was in the range of 0.1–50 ng mL−1. Limits of detection was 0.001 ng mL−1, for acenaphthene, acenaphthylene and fluorene, and 0.01 ng mL−1, for naphthalene and anthracene using time-scheduled selected ion monitoring (SIM) mode, and the RSD% values (n = 3) were all below 11.2% at the 1 ng mL−1 level. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples were from 73.8 to 113.8%.  相似文献   

9.
A novel method, termed ionic liquid cold-induced aggregation dispersive liquid–liquid microextraction (IL-CIA-DLLME), combined with high-performance liquid chromatography (HPLC) was developed for the determination of three phthalate esters in water samples. Several important parameters influencing the IL-CIA-DLLME extraction efficiency, such as the type of extraction and disperser solvent, the volume of extraction and disperser solvent, temperature, extraction time and salt effect, were investigated. Under optimal extraction conditions, the enrichment factors and extraction recoveries ranged from 174 to 212 and 69.9 to 84.8%, respectively. Excellent linearity with coefficients of correlation from 0.9968 to 0.9994 was observed in the concentration range of 2–100 ng mL−1. The repeatability of the proposed method expressed as relative standard deviations ranged from 2.2 to 3.7% (n = 5). Limits of detection were between 0.68 and 1.36 ng mL−1. Good relative recoveries for phthalate esters in tap, bottled mineral and river water samples were obtained in the ranges of 91.5–98.1%, 92.4–99.2% and 90.1–96.8%, respectively. Thus, the proposed method has excellent potential for the determination of phthalate esters in the environmental field.  相似文献   

10.
A method based on immersed solid-phase microextraction (SPME) and gas chromatography mass spectrometry detection (GC-MS) for the determination of organophosphorous pesticides (OPPs) in aqueous samples was developed. A sol-gel based coating fiber was prepared using 3-(trimethoxysilylpropyl) amine as precursor. The synthesized fiber was prepared in a way to impart polar moiety into the coating network and would be more suitable for extracting polar and semi-polar organic pollutants. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 30 °C gave maximum peak area, when NaCl (20% w/v) was added to the aqueous sample. The linearity for disulfoton, phorate and sulfotep was in the concentration range of 0.01 to 5 ng mL− 1 and for parathion and O,O,O-triethylthiphosphate was in the range of 0.01 to 50 ng mL− 1. Limits of detection ranged from 1 ng L− 1, for parathion, to 0.05 ng L− 1, for disulfoton using time-scheduled selected ion monitoring (SIM) mode, and the RSD% values were all below 10.5% at the 1 ng mL− 1 level. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples were from 80 to 115%.  相似文献   

11.
Han J  Wang Y  Yu C  Li C  Yan Y  Liu Y  Wang L 《Analytica chimica acta》2011,(2):138-145
Ionic liquid–salt aqueous two-phase flotation (ILATPF) is a novel, green, non-toxic and sensitive samples pretreatment technique. ILATPF coupled with high-performance liquid chromatography (HPLC) was developed for the analysis of chloramphenicol, which combines ionic liquid aqueous two-phase system (ILATPS) based on imidazolium ionic liquid (1-butyl-3-methylimidazolium chloride, [C4mim]Cl) and inorganic salt (K2HPO4) with solvent sublation. In ILATPF systems, phase behaviors of the ILATPF were studied for different types of ionic liquids and salts. The sublation efficiency of chloramphenicol in [C4mim]Cl–K2HPO4 ILATPF was influenced by the types of salts, concentration of K2HPO4 in aqueous solution, solution pH, nitrogen flow rate, sublation time and the amount of [C4mim]Cl. Under the optimum conditions, the average sublation efficiency is up to 98.5%. The mechanism of ILATPF contains two principal processes. One is the mechanism of IL–salt ILATPS formation, the other is solvent sublation. This method was practical when applied to the analysis of chloramphenicol in lake water, feed water, milk, and honey samples with the linear range of 0.5–500 ng mL−1. The method yielded limit of detection (LOD) of 0.1 ng mL−1 and limit of quantification (LOQ) of 0.3 ng mL−1. The recovery of CAP was 97.1–101.9% from aqueous samples of environmental and food samples by the proposed method. Compared with liquid–liquid extraction, solvent sublation and ionic liquid aqueous two-phase extraction, ILATPF can not only separate and concentrate chloramphenicol with high sublation efficiency, but also efficiently reduce the wastage of IL. This novel technique is much simpler and more environmentally friendly and is suggested to have important applications for the concentration and separation of other small biomolecules.  相似文献   

12.
Guangshu Zhai 《Talanta》2009,77(4):1273-1033
A novel on-line coupled HPLC-hydride generation (HG)-ICP/MS system was developed for rapid, direct and sensitive speciation of methyltins in seawater without any pretreatment step. Methyltin compounds were separated by reversed phase HPLC, and then on-line reacted with potassium borohydride and acetic acid to generate volatile hydride products. The volatile derivatization products were separated in the spray chamber of ICP/MS and then introduced into ICP/MS by argon gas for detection. Monomethyltin (MMT), dimethyltin (DMT) and trimethyltin (TMT) were baseline separated in less than 15 min by reversed phase HPLC. The influence of KBH4 concentration and type of acid on the system performance was investigated and optimized. Calibration curves, based on peak heights against concentration, were linear in the range of 0.5-50 ng (Sn) mL−1 of methyltins with correlation coefficients of 0.9990, 0.9990 and 0.9996 for MMT, DMT and TMT, respectively. The relative standard deviations measured at 10 ng (Sn) mL−1 for these three methyltins were in the range of 0.6-1.4% (n = 5), and the calculated detection limits (S/N = 3) for MMT, DMT and TMT were 0.266, 0.095 and 0.039 ng (Sn) mL−1, respectively. This method was successfully applied to the speciation of methyltins in seawater with spiked recovery in the range of 95.4-106.9%. MMT and DMT were detected in all the seawater samples with concentrations in the range of 1.0-1.5 and 0.30-0.57 ng (Sn) mL−1 for MMT and DMT, respectively.  相似文献   

13.
The nickel–aluminum layered double hydroxide (Ni–Al LDH) was synthesized by a simple co-precipitation method with controlled pH and followed by hydrothermal treatment. The obtained nano-structured inorganic material was employed, for the first time, as a new solid-phase extraction (SPE) sorbent for the extraction and pre-concentration of trace levels of fluoride ions from aqueous solutions. An indirect method was used for monitoring of extracted fluoride ions. The method is based on the quenching effect of extracted fluoride ions upon the fluorescence intensity of Al–oxine complex via the forming of AlF63−, which was determined spectrofluorometrically at λem = 510 nm with excitation at λex = 404 nm. The effect of several parameters such as type of interlayer anion in Ni–Al LDH structure, pH, sample flow rate, elution conditions, amount of nano-sorbent, sample volume and co-existing ions on the extraction efficiency of the analyte were investigated. The results showed that fluoride ions could be retained on the Ni–Al (NO3) LDH at pH 6.0 and stripped by 1.2 mL of 3.0 mol L−1 NaOH. In the optimum experimental conditions, the limit of detection (3 s) and enrichment factor were 9.0 ng mL−1 and 50, respectively. The optimized method was successfully applied to the determination of fluoride concentration in various water samples. The results obtained from the proposed method were successfully compared with those provided by standard SPADNS method.  相似文献   

14.
A novel and efficient analytical methodology is proposed for extracting and preconcentrating polybrominated diphenyl ethers (PBDEs) from samples of environmental interest prior gas chromatography–mass spectrometry (GC–MS) analysis. It is based on the induction of micellar organized medium by using a non-ionic surfactant (Triton X-114) to extract the target PBDEs. To enable coupling the efficient extracting technique with GC analysis, ultrasound-assisted back-extraction (UABE) into an organic solvent was required. Several factors, including surfactant type and concentration, equilibration temperature and time, ionic strength, pH and buffers nature and concentration were studied and optimized over the extraction efficiency of the proposed technique. Under optimal experimental conditions, the target analytes were quantitatively extracted achieving an enrichment factor of 250 when 10 mL aliquot of ultrapure water spiked with PBDE-standard mixture (10 pg mL−1 each PBDE) was extracted. Method detection limits (MDLs) calculated with aqueous PBDEs solutions as three times the signal-to-noise ratio (S/N), ranged from 1 to 2 pg mL−1 with RSDs values ≤8.5% (n = 5). The coefficients of estimation of the calibration curves obtained following the proposed methodology were ≥0.9987 and linear range of all PBDEs was 4–150 pg mL−1. The proposed methodology was validated by carrying out a recovery study by spiking the samples at two different concentration levels of PBDEs (10 and 50 pg mL−1 for waters samples). Recoveries values in the range of 96–106% for water samples were obtained showing satisfactory robustness of the method for analyzing PBDEs in water samples. The proposed methodology was applied for the analysis of PBDEs: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153) in water samples, including drinking, lake, river water and soil samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

15.
Hemimicelles of tetradecanoate chemisorbed onto magnetic nanoparticles (MNPs) are here proposed as a sorbent for the single-step extraction and cleanup of bisphenol A (BPA) in soft drinks. The purpose of this work was to develop a simple, rapid and low-cost sample treatment suitable to assess the human exposure to BPA from this type of high consumption food. The nanoparticles were easily coated by mixing commercially available magnetite of 20–30 nm mean particle diameter with tetradecanoate at 85 °C for 30 min. The extraction/cleanup procedure involved stirring the samples (3 mL) with 200 mg of tetradecanoate-coated MNPs for 20 min, isolating the sorbent with a Nd–Fe–B magnet and eluting BPA with methanol. The extraction efficiency was not influenced by salt concentrations up to 1 M and pH values over the range 4–9. No cleanup of the extracts was needed, and the method proved matrix-independent. The extracts were analyzed by liquid chromatography, electrospray ionization tandem mass spectrometry. Quantitation was performed by internal standard calibration using BPA-13C12. The limit of quantitation obtained for the method, 0.03 ng mL−1, was below the usual range of concentrations reported for BPA in soft drinks (0.1–3.4 ng mL−1). The proposed method was successfully applied to the determination of BPA in different samples acquired from various supermarkets in southern Spain; the concentrations found ranged from 0.066 to 1.08 ng mL−1. Recoveries from samples spiked with 0.33 ng mL−1 of BPA ranged from 91% to 105% with relative standard deviations from 3% to 8%.  相似文献   

16.
A new procedure, based on hollow fiber supported liquid membrane preconcentration coupled with graphite furnace atomic absorption spectrometry (GFAAS) detection, was developed for the determination of trace Cd in seawater samples. With 1-octanol that contained a mixture of dithizone (carrier) and oleic acid immobilized in the pores of the polypropylene hollow fiber as a liquid membrane, Cd was selectively extracted from water samples into 0.05 M HNO3 that filled the lumen of the hollow fiber as a stripping solution. The main extraction related parameters were optimized, and the effects of salinity and some coexisting interferants were also evaluated. Under the optimum extraction conditions, an enrichment factor of 387 was obtained for a 100-mL sample solution. In combination with graphite furnace atomic absorption spectrometry, a very low detection limit (0.8 ng L− 1) and a relative standard deviation (2.5% at 50 ng L− 1 level) were achieved. Five seawater samples were analyzed by the proposed method without dilution, with detected Cd concentration in the range of 56.4–264.8 ng L− 1 and the relative spiked recoveries over 89%. For comparison, these samples were also analyzed by the Inductively Coupled Plasma Mass Spectrometry (ICP-MS) method after a 10-fold dilution for matrix effect elimination. Statistical analysis with a one-way ANOVA shows no significant differences (at 0.05 level) between the results obtained by the proposed and ICP-MS methods. Additionally, analysis of certified reference materials (GBW (E) 080040) shows good agreement with the certified value. These results indicate that this present method is very sensitive and reliable, and can effectively eliminate complex matrix interferences in seawater samples.  相似文献   

17.
Hexanal and heptanal are endogenous aldehydes coming from membrane lipid oxidation, found in lung cancer patients’ blood, and suggested as lung tumor biomarkers. Here the urinary matrix was investigated instead of blood and the difficulties related to the determination of endogenous substances in biological matrices were faced by developing an external calibration HS-SPME/GC/MS method. The methodology was validated according to international validation procedures and it was verified analyzing unknown biological samples from cancer patients and healthy subjects. Percentage accuracy and precision, ranging from −11.25 to 10.85% and from 0.45 to 4.46%, respectively, were obtained, together with limits of detection (LODs) and lower limits of quantification (LLOQs) of 0.11 and 0.23 pg μL−1 for hexanal and of 0.10 and 0.21 pg μL−1 for heptanal. Analytes percentage recoveries (66.3%, hexanal and 70.5%, heptanal) and stability were evaluated. No analytes degradation was found at room temperature, while the remarkable analytes loss found after 1 month storage suggests analyzing biological samples within a week from storage. Results coming from the analysis of unknown biological samples showed no evident differences of heptanal urinary excretion between lung cancer patients and healthy subjects (0.22–0.95 and 0.21–0.69 pg μL−1, respectively), while hexanal urinary concentrations in cancer patients (0.24–4.36 pg μL−1) were slightly higher than those found in control group ones (0.23–1.26 pg μL−1). The obtained results highly suggest to do further investigations in order to collect statistically significant biological data to discriminate between the pathological state of lung cancer patients and physiological conditions of healthy subjects, using the simple, rapid and cheap method here reported for the quantification of urinary aldehydes.  相似文献   

18.
A simple, efficient, innovative and environmentally friendly analytical technique was successfully applied for the first time for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) from water samples. The PBDEs selected for this work were those most commonly found in the literature in natural water samples: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153). The extracted PBDEs were separated and determined by gas chromatography–mass spectrometry (GC–MS). The extraction/preconcentration technique is based on ultrasound-assisted emulsification-microextraction (USAEME) of a water-immiscible solvent in an aqueous medium. Several variables including, solvent type, extraction time, extraction temperature and matrix modifiers were studied and optimized over the relative response the target analytes. Chloroform was used as extraction solvent in the USAEME technique. Under optimum conditions, the target analytes were quantitatively extracted achieving enrichment factors (EF) higher than 319. The detection limits (LODs) of the analytes for the preconcentration of 10 mL sample volume were within the range 1–2 pg mL−1. The relative standard deviations (RSD) for five replicates at 10 pg mL−1 concentration level were <10.3%. The calibration graphs were linear within the concentration range of 5–5000 pg mL−1 for BDE-47 and BDE-100; and 5–10,000 pg mL−1 for BDE-99 and BDE-153, respectively. The coefficients of estimation were ≥0.9985. Validation of the methodology was performed by standard addition method at two concentration levels (10 and 50 pg mL−1). Recovery values were ≥96%, which showed a successful robustness of the analytical methodology for determination of picogram per milliliter of PBDEs in water samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

19.
We describe the development of a liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometric (LC/NI-APPI/MS/MS) method for the simultaneous determination of tetrabromobisphenol A (TBBP-A) and five polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100, BDE-153 and BDE-154) in water. A mobile phase methanol/acetone/water was used, where acetone acts also as dopant. NI-APPI produced precursor ions corresponding to [M−H] for TBBP-A, [M−Br+O], and [M−2Br+O] for the BDE congeners studied. Each compound was quantified operating in multiple reaction monitoring mode. Linearity was observed in the range 0.025–10 ng injected for all compounds. Coefficients of determination R2 ranged from 0.9934 to 0.9982. BDEs were poorly retained by solid-phase extraction (SPE) from river water and sewage treatment plant effluent, thus liquid–liquid extraction (LLE) by n-hexane should be used for these samples. The recoveries of TBBP-A and PBDEs from tap water (SPE), river water and industrial wastewater (LLE) were in the range of 81–88%, 78–92%, and 43–99%, respectively, with relative standard deviations below 17%. The limits of detection, based on signal-to-noise ratio of 3, ranged from 0.004 to 0.1 ng injected, and method quantification limits were 0.2–3.3 ng L−1 but BDE47 (20.3 ng L−1). Only TBBP-A was found in a treated industrial sewage at 4 ng L−1, while BDE-99 and BDE-100 were detected on suspended solids.  相似文献   

20.
Three complexes of composition [CrL(X)3], where L = 4′-(2-pyridyl)-2,2′:6′,2″-terpyridine and X = Cl, N3, NCS are synthesized. They are characterized by IR, UV–Vis, fluorescence, EPR spectroscopic, and X-ray crystallographic studies. Structural studies reveal that the Cr(III) ion is coordinated by three N atoms of L in a meridional fashion. The three anions occupy the other three coordination sites completing the mer-N3Cl3 (1) and mer-N3N3 (2 and 3), distorted octahedral geometry. The Cr–N2 has a shorter length than the Cr–N1 and Cr–N3 distances and the order Cr–N(NCS) < Cr–N(N3) < Cr–Cl is observed. They exhibit some of the d–d transitions in the visible and intra-ligand transitions in the UV regions. The lowest energy d–d transition follows the trend [CrLCl3] < [CrL(N3)3] < [CrL(NCS)3] consistent with the spectrochemical series. In DMF, they exhibit fluorescence having π → π character. All the complexes show a rhombic splitting as well as zero-field splitting (zfs) in X-band EPR spectra at 77 K.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏