首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Spin echo formation in magnetic field gradients in the presence of fast stochastic motion is studied for hyperpolarized 3He gas at different diffusivities. The fast translational motion leads to frequency shifts already during echo formation, which can be described analytically for a linear gradient. Despite complete signal loss at the position of the spin echo itself, considerable intensity can be preserved at an earlier time (sqrt[2]tau rather than 2tau, where tau is the pulse delay). Hence, the phenomenon is designated as a pseudo spin echo.  相似文献   

2.
The amplitudes of gradient-echoes produced using static field gradients are sensitive to diffusion of tissue water during the echo evolution time. Gradient-echoes have been used to produce MR images in which image intensity is proportional to the self-diffusion coefficient of water. However, such measurements are subject to error due to the presence of background magnetic field gradients caused by variations in local magnetic susceptibility. These local gradients add to the applied gradients. The use of radiofrequency (RF) gradients to produce gradient-echoes may avoid this problem. The RF magnetic field is orthogonal to the offset field produced by local magnetic susceptibility gradients. Thus, the effect of the local gradients on RF gradient-echo amplitude is small if the RF field is strong enough to minimize resonance offset effects. The effects of susceptibility gradients can be further reduced by storing magnetization longitudinally during the echo evolution period. A water phantom was used to evaluate the effects of background gradients on the amplitudes of RF gradient-echoes. A surface coil was used to produce an RF gradient of between 1.3 and 1.6 gauss/cm. Gradient-echoes were detected with and without a 0.16 gauss/cm static magnetic field gradient applied along the same direction as the RF gradient. The background static field gradient had no significant effect on the decay of RF gradient-echo amplitude as a function of echo evolution time. In contrast, the effect of the background gradient on echoes produced using a 1.6 gauss/cm static field gradient is calculated to be significant. This analysis suggests that RF gradient-echoes can produce MR images in which signal intensity is a function of the self-diffusion coefficient of water, but is not significantly affected by background gradients.  相似文献   

3.
When fluid saturated porous media are subjected to an applied uniform magnetic field, an internal magnetic field, inside the pore space, is induced due to magnetic susceptibility differences between the pore-filling fluid and the solid matrix. The microscopic distribution of the internal magnetic field, and its gradients, was simulated based on the thin-section pore structure of a sedimentary rock. The simulation results were verified experimentally. We show that the 'decay due to diffusion in internal field' magnetic resonance technique may be applied to measure the pore size distribution in partially saturated porous media. For the first time, we have observed that the internal magnetic field and its gradients in porous rocks have a Lorentzian distribution, with an average gradient value of zero. The Lorentzian distribution of internal magnetic field arises from the large susceptibility contrast and an intrinsic disordered pore structure in these porous media. We confirm that the single exponential magnetic resonance free induction decay commonly observed in fluid saturated porous media arises from a Lorentzian internal field distribution. A linear relationship between the magnetic resonance linewidth, and the product of the susceptibility difference in the porous media and the applied magnetic field, is observed through simulation and experiment.  相似文献   

4.
Nuclear magnetic resonance for cultural heritage   总被引:2,自引:0,他引:2  
Nuclear magnetic resonance (NMR) portable devices are now being used for nondestructive in situ analysis of water content, pore space structure and protective treatment performance in porous media in the field of cultural heritage. It is a standard procedure to invert T(1) and T(2) relaxation data of fully water-saturated samples to get "pore size" distributions, but the use of T(2) requires great caution. It is well known that dephasing effects due to water molecule diffusion in a magnetic field gradient can affect transverse relaxation data, even if the smallest experimentally available half echo time tau is used in Carr-Purcell-Meiboom-Gill experiments. When a portable single-sided NMR apparatus is used, large field gradients due to the instrument, at the scale of the sample, are thought to be the dominant dephasing cause. In this paper, T(1) and T(2) (at different tau values) distributions were measured in natural (Lecce stone) and artificial (brick samples coming from the Greek-Roman Theatre of Taormina) porous media of interest for cultural heritage by a standard laboratory instrument and a portable device. While T(1) distributions do not show any appreciable effect from inhomogeneous fields, T(2) distributions can show strong effects, and a procedure is presented based on the dependence of 1/T(2) on tau to separate pore-scale gradient effects from sample-scale gradient effects. Unexpectedly, the gradient at the pore scale can be, in some cases, strong enough to make negligible the effects of gradients at the sample scale of the single-sided device.  相似文献   

5.
With a proper timing of pi pulses, it is possible to reduce the effect of the static internal magnetic field gradient on the measurement of diffusion with the pulsed gradient spin echo (PGSE). A pulse sequence that in the first order eliminates the effect of weak internal static gradients in a standard PGSE experiment is introduced. The method should be applied in the cases, where strong and short magnetic gradient pulses are used to investigate the motion of liquid in heterogeneous samples with large susceptibility differences such as porous media.  相似文献   

6.
Internal magnetic gradient plays a significant role in Nuclear Magnetic Resonance (NMR) measurements of fluid saturated porous media. The quantitative characterization and application of this physical phenomenon could effectively improve the accuracy of NMR measurements and interpretations. In this paper, by using the equivalent magnetic dipole method, the three-dimensional distribution of internal induced magnetic field and its gradients in the randomly packed water saturated glass beads are quantitatively characterized. By simulating the diffusive motion of water molecules in porous media with random walk method, the computational dephasing effects equation related to internal gradients is deduced. Thereafter, the echo amplitudes are obtained and the corresponding T 2-G spectrum is also inverted. For the sake of verifying the simulation results, an experiment is carried out using the Halbach core analyzing system (B 0=0.18 T, G=2.3 T/m) to detect the induced internal field and gradients. The simulation results indicate the equivalent internal gradient is a distribution of 0.12–0.3 T/m, which matched well with the experimental results.  相似文献   

7.
A new stimulated echo based pulsed gradient spin-echo sequence, MAG-PGSTE, has been developed for the determination of self-diffusion in magnetically inhomogeneous samples. The sequence was tested on two glass bead samples (i.e., 212-300 and <106 microm glass bead packs). The MAG-PGSTE sequence was compared to the MAGSTE (or MPFG) (P.Z. Sun, J.G. Seland, D. Cory, Background gradient suppression in pulsed gradient stimulated echo measurements, J. Magn. Reson. 161 (2003) 168-173; P.Z. Sun, S.A. Smith, J. Zhou, Analysis of the magic asymmetric gradient stimulated echo sequence with shaped gradients, J. Magn. Reson. 171 (2004) 324-329; P.Z. Sun, Improved diffusion measurement in heterogeneous systems using the magic asymmetric gradient stimulated echo (MAGSTE) technique, J. Magn. Reson. 187 (2007) 177-183; P. Galvosas, F. Stallmach, J. K?rger, Background gradient suppression in stimulated echo NMR diffusion studies using magic pulsed field gradient ratios, J. Magn. Reson. 166 (2004) 164-173, P. Galvosas, PFG NMR-Diffusionsuntersuchungen mit ultra-hohen gepulsten magnetischen Feldgradienten an mikropor?sen Materialien, Ph.D. Thesis, Universit?t Leipzig, 2003, P.Z. Sun, Nuclear Magnetic Resonance Microscopy and Diffusion, Ph.D. Thesis, Massachusetts Institute of Technology, 2003] sequence and Cotts 13-interval [R.M. Cotts, M.J.R. Hoch, T. Sun, J.T. Marker, Pulsed field gradient stimulated echo methods for improved NMR diffusion measurements in heterogeneous systems, J. Magn. Reson. 83 (1989) 252-266] sequence using both glass bead samples. The MAG-PGSTE and MAGSTE (or MPFG) sequences outperformed the Cotts 13-interval sequence in the measurement of diffusion coefficients; more interestingly, for the sample with higher background gradients (i.e., the <106 microm glass bead sample), the MAG-PGSTE sequence provided higher signal-to-noise ratios and thus better diffusion measurements than the MAGSTE and Cotts 13-interval sequences. In addition, the MAG-PGSTE sequence provided good characterization of the surface-to-volume ratio for the glass bead samples.  相似文献   

8.
Pulsed field gradient (PFG) NMR diffusion measurements in heterogeneous media may lead to erroneous results due to the disturbing influence of internal magnetic field gradients. Here, we present a simple theoretical model which allows one to interpret data obtained by stimulated spin echo PFG NMR in the presence of spatially varying internal field gradients. Using the results of this theory, the genuine self-diffusion coefficients in heterogeneous media may be extrapolated from the dependence of the apparent diffusivities on the dephasing time of the simulated echo PFG NMR sequence. Experimental evidence that such extrapolation yields satisfactory results for self-diffusion of hexadecane in natural sediments (sand) and of n-octanol in doped MgO pastes is provided.  相似文献   

9.
We present a detailed comparison between the theoretically computed spin echo decay of a fluid-saturated periodic porous medium with strong internal field gradients and that obtained from various approximations using the free diffusion formula which is strictly valid only for infinite uniform fluids. The theoretical computation of the spin echo amplitude was carried out by using the diffusion eigenstates in Fourier representation, and the internal field gradients induced by magnetic susceptibility contrast were calculated by using a two-component composite theory. The comparison allows us to have an assessment of the regime of validity of various approximations for a periodic porous medium where a rigorous theoretical computation of the enhanced transverse relaxation due to magnetic susceptibility contrast induced field heterogeneity is possible.  相似文献   

10.
By evaluating the spin echo attenuation for a generalized 13-interval PFG NMR sequence consisting of pulsed field gradients with four different effective intensities (F(p/r) and G(p/r)), magic pulsed field gradient (MPFG) ratios for the prepare (G(p)/F(p)) and the read (G(r)/F(r)) interval are derived, which suppress the cross term between background field gradients and the pulsed field gradients even in the cases where the background field gradients may change during the z-store interval of the pulse sequence. These MPFG ratios depend only on the timing of the pulsed gradients in the pulse sequence and allow a convenient experimental approach to background gradient suppression in NMR diffusion studies with heterogeneous systems, where the local properties of the (internal) background gradients are often unknown. If the pulsed field gradients are centered in the tau-intervals between the pi and pi/2 rf pulses, these two MPFG ratios coincide to eta=G(p/r)/F(p/r)=1-8/[1+(1/3)(delta/tau)(2)]. Since the width of the pulsed field gradients (delta) is bounded by 0< or =delta< or =tau, eta can only be in the range of 5< or =-eta< or =7. The predicted suppression of the unwanted cross terms is demonstrated experimentally using time-dependent external gradients which are controlled in the NMR experiment as well as spatially dependent internal background gradients generated by the magnetic properties of the sample itself. The theoretical and experimental results confirm and extend the approach of Sun et al. (J. Magn. Reson. 161 (2003) 168), who recently introduced a 13-interval type PFG NMR sequence with two asymmetric pulsed magnetic field gradients suitable to suppress unwanted cross terms with spatially dependent background field gradients.  相似文献   

11.
Diffusion measurements in heterogeneous media may contain a significant source of error, the influence of the coupling between the applied and internal magnetic field gradients on the attenuation of the NMR signal. The application of bipolar magnetic field gradients has been introduced to suppress this error. The basic assumption for the successful removal of the coupling is that the diffusing molecules are experiencing a constant internal gradient during the experiment. We will provide theoretical and experimental evidence that the application of bipolar magnetic field gradients may fail to suppress the effect from all the cross terms between internal and applied gradients effectively at long observation times. It will be shown experimentally that a successful suppression of the cross terms is strongly dependent on the observation time, and on the tau value in the bipolar pulsed field gradient stimulated echo experiment. Copyright 2000 Academic Press.  相似文献   

12.
For a liquid sample with unrestricted diffusion in a constant magnetic field gradient g, the increase R in R2=1/T2 for CPMG measurements is 1/3(taugammag)2D, where gamma is magnetogyric ratio, tau is the half the echo spacing TE, and D is the diffusion constant. For measurements on samples of porous media with pore fluids and without externally applied gradients there may still be significant pore-scale local inhomogeneous fields due to susceptibility differences, whose contributions to R2 depend on tau. Here, diffusion is not unrestricted nor is the field gradient constant. One class of approaches to this problem is to use an "effective gradient" or some kind of average gradient. Then, R2 is often plotted against tau2, with the effective gradient determined from the slope of some of the early points. In many cases, a replot of R2 against tau instead of tau2 shows a substantial straight-line interval, often including the earliest available points. In earlier work [G.C. Borgia, R.J.S. Brown, P. Fantazzini, Phys. Rev. E 51 (1995) 2104; R.J.S. Brown, P. Fantazzini, Phys. Rev. B 47 (1993) 14823] these features were noted, and attention was called to the fact that very large changes in field and gradient are likely for a small part of the pore fluid over distances very much smaller than pore dimensions. A truncated Cauchy-Lorentz (C-L) distribution of local fields in the pore space was used to explain observations, giving reduced effects of diffusion because of the averaging properties of the C-L distribution, the truncation being at approximately +/-1/2chiB0, where chi is the susceptibility difference. It was also noted that, when there is a narrow range of pore size a, over a range of about 40 of the parameter xi=1/3chinua2/D, where nu is the frequency, R2 does not depend much on pore size a nor on diffusion constant D. Examples are shown where plots of R2 vs tau show better linear fits to the data for small tau values than do plots vs tau2. The present work shows that, if both grain-scale and sample-scale gradients are present for samples with narrow ranges of T2, it may be possible to identify the separate effects with the linear and quadratic coefficients in a second-order polynomial fit to the early data points. Of course, many porous media have wide pore size and T2 distributions and hence wide ranges of xi. For some of these wide distributions we have plotted R2 vs tau for signal percentiles, normalized to total signal for shortest tau, again showing initially linear tau-dependence even when available data do not cover the longest and/or shortest T2 values for alltau values. For the examples presented, both the intercepts and the initial slopes of the plots of R2 vs tau increase systematically with signal percentile, starting at smallest R2.  相似文献   

13.
Kaolin clay samples were mixed with various amounts of Fe2O3 powder. The influence of this magnetic impurity on NMR relaxation and diffusion measurements on the water in this porous material was investigated. The NMR relaxation measurements showed a nearly mono-exponential decay, leading to the conclusion that the pore size distribution of the clay samples is either narrow and/or that the pores are interconnected very well. Both the longitudinal and the transverse relaxation rate depend linearly on the concentration of the Fe2O3 impurity. The NMR diffusion measurements revealed that the Fe2O3 causes internal magnetic field gradients that largely exceed the maximum external gradient that could be applied by our NMR apparatus (0.3 T/m). Additional SQUID measurements yielded the magnetization and magnetic susceptibility of the samples at the magnetic field strength used in the NMR measurements (0.8 T). A theoretical estimate of the internal magnetic field gradients leads to the conclusion that the water in the porous clay samples cannot be described by the commonly observed motional averaging regime. Probably an intermediate or a localization regime is induced by the large internal gradients, which are estimated to be on the order of 1 to 10 T/m in the pore volume and may exceed 1000 T/m at the pore surface.  相似文献   

14.
The diffusion-dependent decay of spin-echo signals from samples distributed over non-uniform field gradients is analyzed. This decay deviates from the linear semilogarithmic dependencies on t3 or t obtained, respectively, in Hahn spin-echo or Carr-Purcell echo trains from spins in constant field gradients. It is demonstrated here that when the average diffusion distance is small compared to the spatial variation of the gradient, the spin-echo decay can be modeled by a simple superposition of signals from a large number of microdomains, each characterized by a different gradient. This is illustrated by two examples, a water sample in a deliberately created quadratic variation of the external field, and a saturated water/ sand mixture with large internal field gradients.  相似文献   

15.
Diffusion of precessing spins through a constant field gradient is well-known to produce two distinctive features: an exp(-bt(3)) decay of the echo amplitude in response to two pulses and a much slower decay of the Carr-Purcell echo train. These features will appear whenever the spin frequency is described by a continuous random-walk. The present work shows that this may also occur in the presence of motions with long correlation times tau(c)-continuous Gaussian frequency noise with an exponential autocorrelation has the correct properties over time durations smaller than tau(c). Thus, time-cubed echo decays will occur in situations other than physical diffusion. The decay rate of the Carr-Purcell echo train is shown to vary with the pulse spacing tau whenever the correlation time tau(c) is long; the slower Carr-Purcell decay compared to the two-pulse echo decay is not unique to diffusion. Simulations are presented that display time-cubed decays. The simulations confirm two important criteria: the echo time must be less than tau(c) and the frequency noise must consist of nearly continuous variations, as opposed to step-like changes. These criteria define the range of physical parameters for which time-cubed decays will be observable.  相似文献   

16.
A suitably matched combination of unidirectional gradient pulses of the radio frequency amplitude B(1) and of the main magnetic field B(0) produces an unconventional type of spin echo, the nutation echo. The echo signal becomes volume selective if the gradients to be matched are inhomogeneously distributed in space. An example is a combination of a constant B(0) gradient and the inhomogeneous B(1) gradient of a surface coil. We suggest a method for localized NMR on this basis. Nutation echoes can also be used to map the spatial distribution of B(1) gradients of an arbitrary radio frequency coil geometry with the aid of a small probe sample. Copyright 2000 Academic Press.  相似文献   

17.
Diffusion in porous media has been used as a probe of pore geometry in various NMR techniques. We will examine the effect of time-dependent diffusion in CPMG by showing that the diffusion time in CPMG is approximately the echo time, even in grossly inhomogeneous magnetic fields. Extension of the diffusion time in modified CPMG sequences is discussed. Diffusion in the susceptibility-contrast induced internal field is discussed as a means to probe pore size and pore shape. Finally, we present the general concept of two-dimensional relaxation-type experiments for study of molecules, fluids, materials and their dynamics that are characterized by spin relaxation and diffusion.  相似文献   

18.
Carr-Purcell-Meiboom-Gill train of radiofrequency pulses applied to spins in the constant magnetic field gradient is an efficient variant of the modulated magnetic field gradient spin echo method, which provides information about molecular diffusion in the frequency-domain instead in the time-domain as with the two-pulse gradient spin echo. The frequency range of novel technique is broad enough to sample the power spectrum of displacement fluctuation in water-saturated pulverized silica (SiO(2)) and provides comprehensive information about the molecular restricted motion as well as about the structure of medium.  相似文献   

19.
We present a new method for observing fluid diffusion in a porous medium. The method employs 2D exchange spectroscopy for molecules diffusing in the presence of local magnetic field inhomogeneities, in our case distilled water in various sized glass bead packs. Our experiment involves an acquisition and evolution time domain with the two Fourier domains corresponding to the spectral distribution of local fields. We show that exchange in the internal magnetic field can be seen in a 2D spectrum with a characteristic time on the order of that required to diffuse 0.15 sphere diameters with similar behavior found for computer simulations. The method is potentially useful for studying the internal migrations in more complicated systems such as sandstones or other porous media.  相似文献   

20.
Nuclear magnetic resonance (NMR) plays a significant role in porous media analysis and petroleum exploration, but its response is significantly influenced by the internal magnetic field gradient in fluid saturated porous medium, which obviously limits the accuracy of rock core analysis and logging interpretation. The influential factors of the internal magnetic field gradient in formation and its influences on NMR response are studied in this paper, based on NMR mechanism through one- and two-dimensional core NMR experiments. The results indicate that the internal magnetic field gradient is positively correlated with the static magnetic field strength and the magnetic susceptibility difference between pore fluid and solid grains, while it presents negative correlation with pore radius. The internal magnetic field gradient produces an additional diffusion relaxation in hydrogen relaxation system and accelerates the attenuation of magnetization vector. As a result, T2 spectrum shifts to the left and NMR porosity and diffusion coefficient of the fluid could be inaccurate. This research sets a foundation for the NMR porosity correction and fluid distribution on T2-G maps based on the internal magnetic field gradient correction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号