首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

2.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

3.
Metformin is an antihyperglycemic drug that exhibits some antioxidant properties. HO*-induced oxidation of metformin was studied in aqueous solution, in both aerated and deaerated conditions. Gamma radiolysis of water was used to generate HO* free radicals, capable of initiating one-electron oxidation of metformin. Oxidation end-products were identified by direct infusion mass spectrometry (MS) and high-performance liquid chromatography/mass spectrometry (HPLC/MSn): for every product, structure elucidation was based on its mass (simple mass spectra confirmed by HPLC/MS). In addition, fragmentation spectra (MS2, MS3 and MS4) and the determination of deuterium-hydrogen exchange sites provided valuable information allowing the complete identification of some of the end-products. At low radiation dose, four products were identified as primary ones, since they result from the direct attack of HO* radicals on metformin. These primary oxidation end-products were identified respectively as hydroperoxide of metformin, covalent dimer of metformin, methylbiguanide and 2-amino-4-imino-5-methyl-1,3,5-triazine. At high radiation dose, seven other products were identified as secondary ones, resulting from the HO*-induced oxidation of the primary end-products. A reaction scheme was postulated for the interpretation of the results.  相似文献   

4.
A sensitive high‐performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for measuring vinorelbine was developed. A 100 µL aliquot of plasma was spiked with deuterium‐labeled internal standard and subjected to solid‐phase extraction using an Oasis HLB μ‐elution plate. Two microliters of the extracted samples was directly injected into LC/MS/MS. Chromatographic separation was achieved on a Capcell Pak C18 UG column (2 × 75 mm) with a gradient elution of methanol (mobile phase B) against 0.05% formic acid in aqueous 10 mm ammonium formate (mobile phase A). The LC flow rate was set to 0.28 mL/min and the gradient (solvent B concentration) was processed from 40 to 90%. In mass spectrometric detection, observation of the reaction from a double‐charged precursor ion [M + 2H]2+ (m/z 390) to product ion m/z 122 provided very high sensitivity. The method was validated with a lower limit of detection of 0.2 ng/mL with 0.1 mL of plasma, and the method was used to determine the plasma pharmacokinetics of vinorelbine in dogs. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of alpha-,beta-arteether (alpha-,beta-AE) and its metabolite alpha-dihydroartemisinin (DHA) in monkey plasma using the propyl ether analogue of beta-arteether (PE) as an internal standard. The method involves a simple two-step liquid-liquid extraction with hexane. The analytes were chromatographed on a C(18) reversed-phase chromatographic column by isocratic elution with methanol-ammonium acetate buffer (pH 4) (92 : 8, v/v) and analysed by mass spectrometry in the multiple reaction monitoring mode. The chromatographic run time was 7 min and the weighted (1/x(2)) calibration curves were linear over the range 0.78-200 ng ml(-1). The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in monkey plasma were 0.39 and 0.78 ng ml(-1) respectively for all the analytes. The intra- and inter-batch precision and accuracy were found to be well within acceptable limits (<15%). All three analytes were stable even after three freeze-thaw cycles (deviation < 15%). The average absolute recoveries of alpha-,beta-AE, DHA and PE, used as an internal standard, from spiked plasma samples were 85.85 +/- 6.56, 70.10 +/- 7.06, 54.37 +/- 3.39 and 93.90 +/- 6.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of alpha-,beta-AE and DHA in rhesus monkeys.  相似文献   

6.
Two model peptides, des-Arg1-bradykinin (DAB) and bradykinin (B), were cationized by Ag+ after their separation by reversed-phase liquid chromatography (RPLC) prior to mass spectrometry (MS). Silver nitrate solution was used as a post-column reagent. The RPLC and MS experimental conditions were optimized using flow injection in order to obtain sufficiently abundant silver adducts to permit MS/MS experiments. The use of water-methanol with 0.1% formic acid as mobile phase allowed a good chromatographic separation of the two peptides with a polymeric stationary phase and sufficiently abundant silver-containing adducts, [M + Ag + H]2+ and [M + 2Ag]2+. The gas-phase dissociation of [DAB + Ag + H]2+ and [DAB + 2Ag]2+ led to interpretable mass spectra during the on-line cationization experiment. Most of the ions obtained by dissociating [DAB + Ag + H]2+ and [DAB + 2Ag]2+ species are silver-containing ions but the ions produced depend on the parent. The ions coming from the dissociation of the doubly charged silver adducts [DAB + Ag + H]2+ or [DAB + 2Ag]2+ are of interest compared with those coming from the singly charged silver species or doubly charged protonated species. The fragmentation of the doubly charged silver adducts provides ions over the entire mass range. Although the presence of several prolines in des-Arg1-bradykinin prevents the formation of some expected ions, the observation of triplets [an-H + Ag]+, [bn-H + Ag]+ and [bn + OH + Ag]+ produced by the dissociation of on-line Ag(+)-cationized peptides could contribute to greater success of automatic sequencing of peptides.  相似文献   

7.
Liquid chromatography coupled with ionspray mass spectrometry in the tandem mode (LC/MS/MS) with negative ion detection was used for the identification of a variety of phenolic compounds in a cocoa sample. Gradient elution with water and acetonitrile, both containing 0.1% HCOOH, was used. Standard solutions of 31 phenolic compounds, including benzoic and cinnamic acids and flavonoid compounds, were studied in the negative ion mode using MS/MS product ion scans. At low collisional activation, the deprotonated molecule [M - H](-) was observed for all the compounds studied. For cinnamic and benzoic acids, losses of CO(2) or formation of [M - CH(3)](-*) in the case of methoxylated compounds were observed. However, for flavonol and flavone glycosides, the spectra present both the deprotonated molecule [M - H](-) of the glycoside and the ion corresponding to the deprotonated aglycone [A - H](-). The latter ion is formed by loss of the rhamnose, glucose, galactose or arabinose residue from the glycosides. Different fragmentation patterns were observed in MS/MS experiments for flavone-C-glycosides which showed fragmentation in the sugar part. Fragmentation of aglycones provided characteristic ions for each family of flavonoids. The optimum LC/MS/MS conditions were applied to the characterization of a cocoa sample that had been subjected to an extraction/clean-up procedure which involved chromatography on Sephadex LH20 and thin-layer chromatographic monitoring. In addition to compounds described in the literature, such as epicatechin and catechin, quercetin, isoquercitrin (quercetin-3-O-glucoside) and quercetin-3-O-arabinose, other compounds were identified for the first time in cocoa samples, such as hyperoside (quercetin-3-O-galactoside), naringenin, luteolin, apigenin and some O-glucosides and C-glucosides of these compounds.  相似文献   

8.
The histidine-containing dipeptides carnosine (CAR) and structurally related anserine (ANS) and homocarnosine (HCAR), widely distributed in vertebrate organisms, have recently been proposed as endogenous quenchers for highly cytotoxic alpha,beta-unsaturated aldehydes generated by peroxidation. A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay was developed and validated for the simultaneous determination of these peptides in biological matrices in order to establish their plasma/tissue distribution. Samples (plasma or tissue homogenates from male rats) were prepared by protein precipitation with HClO(4) (1 : 1, v/v) containing H-Tyr-His-OH as internal standard. The supernatant was separated on a Phenomenex Sinergy polar-RP column with a mobile phase of water-acetonitrile-heptafluorobutyric acid (9 : 1 : 0.01, v/v/v) at a flow-rate of 0.2 ml min(-1), with a run time of 10 min. Detection was effected on an ion trap mass spectrometer equipped with an electrospray ionization interface operating in positive ionization mode. The acquisitions were in the multiple reaction monitoring mode using the following precursor --> product ion combinations: H-Tyr-His-OH (internal standard) m/z 319 --> 301; CAR m/z 227 --> 210 + 209; ANS m/z 241 --> 224 + 197 + 170; HCAR m/z 241 --> 156. The method was validated over the concentration range 15-1000 nmol g(-1) and the limit of quantification (LOQ) and limit of detection (LOD) were 12.5 and 4.2 pmol injected, respectively. The intra- and inter-day precisions were <10% (< or =17.47% at the LOQ) and the intra- and inter-assay accuracies were within +/-10% for all concentrations. The mapping profile in rat tissue gave the following results: the highest concentrations of CAR and ANS were found in skeletal muscles (soleus, gastrocnemius, tibialis), followed by the heart, cerebellum and brain (ANS below the LOQ). HCAR was found only in the brain and cerebellum. No histidine-containing dipeptides were detectable in plasma, liver, kidney and lung.  相似文献   

9.
The relationships between the ionization profile, sensitivity, and structures of 64 exogenous anabolic steroids (groups I–IV) was investigated under electrospray ionization (ESI) conditions. The target analytes were ionized as [M + H]+ or [M + H–nH2O]+ in the positive mode, and these ions were used as precursor ions for selected reaction monitoring analysis. The collision energy and Q3 ions were optimized based on the sensitivity and selectivity. The limits of detection (LODs) were 0.05–20 ng/mL for the 64 steroids. The LODs for 38 compounds, 14 compounds and 12 compounds were in the range of 0.05–1, 2–5 and 10–20 ng/mL, respectively. Steroids including the conjugated keto‐functional group at C3 showed good proton affinity and stability, and generated the [M + H]+ ion as the most abundant precursor ion. In addition, the LODs of steroids using the [M + H]+ ion as the precursor ion were mostly distributed at low concentrations. In contrast, steroids containing conjugated/unconjugated hydroxyl functional groups at C3 generated [M + H ? H2O]+ or [M + H ? 2H2O]+ ions, and these steroids showed relatively high LODs owing to poor stability and multiple ion formation. An LC‐MS/MS method based on the present ionization profile was developed and validated for the determination of 78 steroids (groups I–V) in human urine. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
Analytical methods were developed for atorvastatin, novobiocin and roxithromycin using microbore liquid chromatography/electrospray ionization tandem mass spectrometry (microbore LC/ESI-MS/MS) in positive and negative voltage switching mode. Atorvastatin and roxithromycin require the positive-ion mode, whereas the negative-ion mode is required for the determination of novobiocin. Using the positive and negative voltage switching function, the three analytes were determined with one injection, and the time required was half that required using separately run positive- and negative-ion modes, without any reduction in sensitivity. A microbore LC column (100 x 1.0 mm i.d.) was chosen for chromatographic separation with mobile phase solvents acetonitrile and 10 mM aqueous ammonium acetate. The flow-rate was 0.1 ml min(-1) and the injection volume was 1 micro l. The analytes were quantified in the multiple reaction monitoring mode with external standards. By switching the positive and negative voltage, the three analytes were determined with a 4 min chromatographic run and with instrumental detection limits of 1-3 pg. This analytical method, using a microbore LC column combined with solid-phase extraction, was applied successfully to the determination of trace levels of the above pharmaceuticals in aqueous samples. Atorvastatin was detected in a sewage treatment plant final effluent.  相似文献   

11.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

12.
An integrated method of liquid chromatography-heated electrospray ionization/tandem mass spectrometry was evaluated for high throughput screening of various abused drugs in urine. Chromatographic analysis was performed on a C18 reverse phase column using a linear gradient of 10 mM ammonium acetate containing 0.1% formic acid-methanol as mobile phase and the total separation time was 7 min. A simple and rapid sample preparation method used was by passing urine samples through a 0.22 μm PVDF syringe filter. The detection limits of the studied abused drugs in urine were from 0.6 ng mL−1 (ketamine) to 9.0 ng mL−1 (norcodeine). According to the results, the linear range was from 1 to 1200 ng mL−1 with relative standard deviation (R.S.D.s) value below 14.8% (intra-day) and 24.6% (inter-day). The feasibility of applying the proposed method to determine various abused drugs in real samples was examined by analyzing urine samples from drug-abused suspects. The abused drugs including ketamines and amphetamines were detected in suspected urine samples. The results demonstrate the suitability of LC-HESI-MS/MS for high throughput screening of the various abused drugs in urine.  相似文献   

13.
The effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of drug molecules in liquid chromatographic/ionspray tandem mass spectrometric (LC/MS/MS) determination were evaluated for simvastatin (SV) and its hydroxy acid (SVA). The objective was to improve further the sensitivity for SV by overcoming the unfavorable condition caused by the formation of multiple major adduct ions and multiple major fragment ions when using ammonium as LC mobile phase buffer. Mobile phases (70:30 acetonitrile-buffer, 2 mM, pH 4.5) with buffers made from ammonium, hydrazine or alkyl (methyl, ethyl, dimethyl or trimethyl)-substituted ammonium acetate were evaluated. Q1 scan and product ion scan spectra were obtained for SV in each of the mobile phases under optimized conditions. The results showed that, with the alkylammonium buffers, the alkylammonium-adducted SV was observed as the only major molecular ion, while the formation of other adduct ions ([M + H](+), [M + Na](+) and [M + K](+)) was successfully suppressed. On the other hand, product ion spectra with a single major fragment ion were not observed for any of the alkylammonium-adducted SVs. The affinity of the alkylammoniums to SV and the basicity of the alkylamines are believed to be factors influencing the formation and abundance of molecular and fragment ions, respectively. Methylammonium acetate provided the most favorable condition among all the buffers evaluated and improved the sensitivity several-fold for SV in LC/MS/MS quantitation compared with that obtained using ammonium acetate buffer. Better precision for SV in both Q1 and SRM scans was observed when using methylammonium buffer compared with those using ammonium buffer. The mobile phase buffer contents did not seem to affect the ionization, fragmentation and chromatography of SVA. The results of this evaluation can be applied to similar situations with other organic molecules in ionspray LC/MS/MS determination.  相似文献   

14.
A liquid chromatographic/tandem mass spectrometric method is described for the determination of phencyclidine (PCP) in small volumes of rat serum (e.g. 50 microl). Samples were extracted using a mixed-mode strong cation-exchange column and then separated isocratically using a narrow-bore (2.1 mm i.d.) 3 microm Hypersil phenyl column and a mobile phase consisting of an ammonium formate buffer (pH 2.7) with 60% (v/v) methanol. Detection was accomplished using positive ion electrospray ionization in the multiple reaction monitoring mode. Mass spectra were obtained and peaks were observed at an m/z (% abundance) of 244 (100), 159 (25), and 86 (89). Tandem mass spectra were also obtained from the m/z 244 precursor ion with peaks observed at m/z 159 (100), 86 (96), and 91 (11). Optimum serum PCP sensitivity and precision were obtained at a transition of m/z 244 --> 159. Matrix-associated ion suppression did not significantly affect the accuracy (100-112%) or precision (CV < or =8%) of the assay. The lower limit of quantitation was 1 ng ml(-1) in 50 microl of serum. The method was used to study the serum pharmacokinetics of PCP in rats after an intravenous bolus dose of PCP.  相似文献   

15.
A mass spectrometric-based procedure for anthocyanin profiling was set up to distinguish authentic Vitis vinifera from hybrid red grapevine cultivars. 3-O-Monoglucoside and the related acetyl-, p-coumaryl- and caffeoyl-monoglucoside anthocyanins occurred only in Vitis vinifera, whereas 3,5-O-diglucoside and the substituted acetyl-, p-coumaryl-, feruloyl- and caffeoyl-diglucoside anthocyanins were the additional pigments in hybrid grapevines. The procedure was applied expressly to identify red grape cultivars based on the anthocyanin chemo-type determination. In particular, a red grape cultivar, having 3,5-O-diglucoside anthocyanins and a novel class of anthocyanin monoglucosides, such as cyanidin-3-O-, cyanidin-3-O-(6-O-acetyl)- and cyanidin-3-O-(6-O-p-coumaryl)pentoside, was classified as hybrid. A second vine cultivar, characterized exclusively by 3-O-monoglucoside anthocyanins, was included among the Vitis vinifera species. Anthocyanin profiling by mass spectrometry could represent the core of a chemotaxonomic procedure for distinguishing American and European grapevines based on the identification of post-synthetic anthocyanidin modification.  相似文献   

16.
A liquid chromatographic/electrospray ionization tandem mass spectrometric method for the quantification of the synthetic opiate buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine-3-beta-D-glucuronide (BUP-3-G) and norbuprenorphine-3-beta-D-glucuronide (NBUP-3-G) in human plasma was developed and validated. Identification and quantification were based on the following transitions: m/z 468 to 396 and 414 for BUP, m/z 414 to 326 and 340 for NBUP, m/z 644 to 468 for BUP-3-G and m/z 590 to 414 for NBUP-3-G. Calibration by linear regression analysis utilized deuteratated internal standards and a weighting factor of 1/x. The method was accurate and precise across a linear dynamic range of 0.6-50.0 ng ml(-1). Pretreatment of plasma samples using solid-phase extraction was sufficient to limit matrix suppression to <30% for all four analytes. The method proved to be suitable for the quantification of BUP and the related metabolites in plasma samples collected from BUP-maintained study participants.  相似文献   

17.
The aim of this study was to develop a rapid and sensitive method for the quantification of cefquinome in animal plasma and bronchoalveolar lavage (BAL) fluid using high-performance liquid chromatography combined with electrospray tandem mass spectrometry (LC-ESI-MS/MS). Cefadroxil is used as internal standard. For plasma, the sample preparation includes a simple deproteinization step with a Microcon filter. This allows detecting the unbound cefquinome concentration, which is correlated with the concentration in other body fluids, such as BAL fluid. To be able to detect the total plasma concentration, deproteinization with acetonitrile, followed by a back-extraction of actonitrile with dichloromethane was performed. The BAL fluid is centrifuged to precipitate floating particles. Chromatographic separation is achieved on a PLRP-S column using 0.005% formic acid and methanol as mobile phase. For plasma, good linearity was observed in the range of 5-2500 ng ml(-1) for both the unbound and total concentration. The response in BAL fluid was linear in the range of 4-1000 ng ml(-1). The limit of quantification (LOQ) was set at 5.00 ng ml(-1) for plasma and at 4.00 ng ml(-1) for BAL fluid. The limit of detection (LOD) was 3.12 ng ml(-1) and 0.41 ng ml(-1) for the unbound and total concentration in plasma, respectively, and was 1.43 ng ml(-1) for BAL fluid. The method was shown to be of use in a pharmacokinetic study in pigs, where the correlation between cefquinome concentrations in plasma and BAL fluid of pigs was studied.  相似文献   

18.
Pigments are among the most important components of historical paintings and textiles and their nature provides the unique character of color. They can be divided into two main groups: inorganic and organic, extracted from plants or animals. Their identification is a necessary stage in the conservation of art objects. Reversed-phase liquid chromatography with electrospray ionization mass spectrometry (ESI-MS) and UV/visible spectrophotometric methods were elaborated for the identification of indigoid (indigo, indirubin, isoindigo, isoindirubin) color components of natural dyestuffs and their natural or synthetic precursors (indican, isatin, indoxyl, 2-indolinone). ES-MS offers detection limits in the range 0.03-5.00 microg ml(-1) for the color compounds examined. The method developed made it possible to identify indigo and its isomers in genuine Indian indigo, indigo from woad and Tyrian Purple. It was applied to the identification of natural dyes on fiber from a 19th century Japanese tapestry, 'Cranes in the landscape'. A procedure based on freezing and grinding of a sample before the extraction of dyes from the textile was developed. The components of the extract obtained were identified after acidic hydrolysis as indigotin and methylene blue.  相似文献   

19.
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.  相似文献   

20.
The proanthocyanidins in three foods (pinto beans, plums and cinnamon) were studied with electrospray ionization (ESI) mass spectrometry (MS) in the negative mode following separation by normal-phase high-performance liquid chromatography. The MS/MS analysis demonstrated that the major ions derived from heterocyclic ring fission and retro-Diels-Alder reaction of flavan-3-ol provided information about the hydroxylation pattern and type of interflavan bond. The connection sequence of the oligomers was identified through diagnostic ions derived from quinone methide (QM) cleavage of the interflavan bond. Novel heterogeneous B-type proanthocyanidins containing (epi)afzelechin as subunits were identified in pinto beans. Proanthocyanidins with interestingly different A-type linkages were identified in plums and cinnamon. In efforts aimed at extending the identification capacity of ESI-MS to polymers, we found that the polymeric procyanidins fragmented readily instead of forming multiply charged ions in the negative ESI mode. Fragmentation patterns were proposed based on our data obtained by ESI-MS/MS and ESI time-of-flight MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号