首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cinobufacini injection, prepared from the skin of Bufo bufo gargarizans Cantor, has presented its significant effects on the treatment of hepatitis and various cancers in the clinic. However, as an unclear complex chemical system, the optimization of its quality control markers has been a long‐term challenge. In present study, a feasible strategy integrated markers screening, determination, and statistical analysis was efficiently proposed, especially for the undefined Chinese medicine injections. First, rapid separation LC‐quadrupole‐TOF‐MS method was applied in the identification of 19 major compounds in the cinobufacini injection for the first time. Further, nine high‐level contents active compounds were selected as quality control markers for the quantification analysis. An acceptable and validated determination method was established in 17 batches of cinobufacini injection by HPLC‐photodiode array detection method, including linear regression relationship (r2, 0.9996–1), precisions (RSD, 0.02–1.35%), repeatability (RSD, 0.05–1.97%), stability (RSD, 0.1–3.85%), and recovery (95.88–104.89%). Each analyte was detected at its maximum ultraviolet spectra wavelength. Finally, based on the quantification results, principal component analysis was performed on the quality assessment of cinobufacini injections. This three‐step strategy provides a newly feasible solution for the quality control of Chinese medicine injections.  相似文献   

2.
A method of ultra-performance liquid chromatography combined with electrospray ionization triple quadrupole tandem mass spectrometry (UPLC-ESI-MS/MS) has been established for simultaneous determination of major disialoganglioside 3 (GD3) and monosialoganglioside 3 (GM3) in infant formulas and whey protein concentrates. Gangliosides were extracted by using the technique of Svennerholm and Fredman and then cleaned up with OASIS HLB solid-phase extraction (SPE) cartridges. The various molecular species of gangliosides were separated on an Acquity UPLC BEH C8 column and analyzed under the negative ion mode. GD3 and GM3 were rapidly quantified using internal standard (IS) method. The developed method was further validated by determining the linearity, average recovery, sensitivity (limit of quantification), and precision. The results presented high correlation coefficients (R(2) > 0.993) of the selected 16 gangliosides molecular species and provided the respective linear ranges. The limit of quantification was 0.325-0.734 mg/100 g for eight molecular species of GD3 and 0.008-0.312 mg/100 g for eight molecular species of GM3, respectively. The reasonable average recoveries (81-95%) and precision (relative standard deviation [RSD] ≤15%) were also demonstrated in three different spiked levels. This new method would be very useful in the quantitative determination of gangliosides in infant formulas and whey protein concentrates.  相似文献   

3.
Cinobufacini injection is commonly used in the clinical treatment of tumors and hepatitis B, but the quality is uneven. Currently, the main focus of its quality assessment is on steroids and alkaloids. Based on a previous study, we screened four peptides with high reproducibility, responsiveness, and specificity. This research was the first to develop an ultra-high-performance liquid chromatography/triple quadrupole mass spectrometry approach for evaluating the quality of cinobufacini preparations from the peptide perspective. In this study, we have identified 230 peptides in cinobufacini injection by Q-Exactive mass spectrometry, which contains species-specific peptides. Then, we used ultra-high-performance liquid chromatography/triple quadrupole mass spectrometry to establish a quantitative method for species-specific peptides and carried out method validation. The result revealed that four peptides were linear in a specific range, and had great reproducibility, accuracy, and stability. Eventually, we evaluated the quality of eight batches of cinobufacini injections and 26 batches of toad skins using the total content of target peptides as the criterion. The outcomes demonstrated that the quality of cinobufacini injection is generally stable and the toad skin from Shandong is of the best quality. In conclusion, the quantitative approach that focuses on peptides will offer innovative perspectives on assessing the quality of cinobufacini preparations.  相似文献   

4.
Cinobufacini injection that comes from the water extract of Bufo bufo gargarizans Cantor skin is widely used for cancer treatment in China. Peptide is one of its major types of constituents, however the biological effects and content of this injection are little reported. In present study, the analgesic effect of peptides was determined and evaluated by in‐vivo models. To characterize and quantitatively analyze these peptides, a reliable and efficient method combining size exclusion chromatography and matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry with amino acid analysis was developed. The peptides presented as a series of analogs with similar molecular weights mostly ranging from 2 to 8 kDa. The amino acid analysis by gas chromatography mass spectrometry (GC‐MS) was developed to determine both free and combined amino acids (FAA and CAA) in cinobufacini injection. This method achieved good linearity (R2, 0.9909–0.9999) and low limit of detection and quantification. FAA and CAA samples were efficiently analyzed by modified Phenomenex EZ: faast procedure. For the sample analysis, the method showed good repeatability (relative standard deviation, RSD ≤ 10%). For most FAA and CAA the mean recoveries were >80% with RSD <10%. The GC‐MS based method is useful for quality assurance of both FAA and CAA in cinobufacini injection. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
在碱性条件下,头孢他啶对金纳米粒子催化高锰酸钾氧化鲁米诺化学发光体系的发光强度具有明显的增敏作用,基于此建立了一种测定头孢他啶的化学发光方法.在优化实验条件下,用该法测定头孢他啶的线性范围为3.0×10-5~5.0×10-2 g/L,检出限为1.0×10-5 g/L,相对标准偏差为2.0%(ρ=4.0×10-3 g/L...  相似文献   

6.
Fung YS  Lau KM 《Electrophoresis》2001,22(11):2251-2259
A new capillary electrophoresis (CE) procedure was developed for simultaneous determination of ten oxoanions (CrO4(2-), SeO4(2-), MoO4(2-), WO4(2-), VO4(3-), SeO3(2-), As04(3-), TeO3(2-), TeO4(2-), and AsO3(3-)) which were baseline-separated from each other and from the interfering UV absorbing anions (NO3- and NO2-) commonly found in environmental water samples. The new background electrolyte system developed contained 5 mM potassium phosphate and 0.007 mM octadecyltrimethylammonium hydroxide, pH 11.2. The optimized working conditions were electrokinetic sampling at -5 kV for 10 s, running voltage at -15 kV with 5 microA current, and detection wavelength at 205 nm. No interference was observed for non-UV-absorbing anions and UV-absorbing anions up to 20 and 10 times higher concentrations respectively. The speed of analysis was fast, with a complete CE run within 6 min. Wide linear ranges (1-2,000 microg/L), good repeatability in migration time (relative standard deviation RSD 0.55-2.8%), satisfactory precision in peak area (RSD 3.8-5.6%) and peak height (RSD 3.9-5.3%) measurement, and detection limits (1-25 microg/L) sufficiently sensitive to detect oxoanions found in environmental water samples were obtained. The reliability of the CE procedure developed had been established by recovery test and parallel method determination using atomic absoprtion spectrophotometry for real river water sample.  相似文献   

7.
离子色谱法测定醇胺脱硫溶液中热稳定盐   总被引:1,自引:0,他引:1  
Tang F  Wang Y  Luo Q  Tang M  Chen G 《色谱》2012,30(4):378-383
为了控制热稳定盐(HSS)对天然气净化装置造成的危害,建立了一种同时检测醇胺脱硫溶液中的乙酸根离子、甲酸根离子、氯离子、硫酸根离子、草酸根离子、硫代硫酸根离子和硫氰酸根离子的离子色谱方法。该方法利用膜过滤、反相固相萃取和稀释3个步骤对工业样品进行前处理,采用氢氧化钾梯度淋洗和电导检测的方式,实现了7种离子的分离与检测。方法的线性范围为0.01~0.5 mmol/L,检出限(以信噪比(S/N)为3计)小于0.1 mg/L,回收率为80.0%~100.3%。在5个不同添加浓度下分别测定了上述7个离子,色谱峰面积的重复性良好(相对标准偏差(RSD, n=10)为0.94%~3.99%。通过3个实验室比对试验,表明该方法再现性良好,色谱峰面积的RSD小于5%。应用该方法成功地检测了8家天然气净化厂、3家石油炼厂和1家煤制油工厂的脱硫溶液样品中的HSS,并连续监测某天然气净化装置15 d。该方法具有良好的可靠性和实用性。  相似文献   

8.
We developed CZE with indirect UV detection for the determination of phosphate in seawater using transient ITP as an on-line concentration procedure. The following optimum conditions were established: BGE, 5 mM 2,6-pyridinedicarboxylic acid (PDC) containing 0.01% hydroxypropylmethylcellulose (HPMC) adjusted to pH 3.5; detection wavelength, 200 nm; vacuum injection period of sample, 3 s (45 nL); terminating ion solution, 500 mM MES adjusted to pH 4.0; vacuum injection period of the terminating ion solution, 30 s (450 nL); applied voltage, 30 kV with the sample inlet side as the cathode. The LOD for phosphate was 16 microg/L (PO(3-)(4) -P) at S/N of 3. The respective values of the RSD of the peak area, peak height, and migration time for phosphate were 2.6, 2.3, and 0.34%. The proposed method was applied to the determination of phosphate in a seawater certified reference material for nutrients, MOOS-1, distributed by the National Research Council of Canada (NRC). The results were very similar to certified values. The method was also applied to the determination of phosphate in coastal seawaters. The results agreed with those obtained using a conventional spectrophotometric method.  相似文献   

9.
A quantitative analysis was developed for eight acidic and neutral preservatives in foods and daily necessities using the inline dialysis-IC combined with hydrophobic anion-exchange separation. The eight preservatives were dialyzed by inline dialysis and separated on a hydrophobic anion exchange column. Under the optimized separation conditions, the detection limits (S/N = 3) for the eight preservatives were from 0.08 to 0.66 mg L(-1), moreover, a good linearity (R(2) > 0.998) for each preservative was obtained in the range to 100 mg L(-1). Although the dialysis rate of the neutral preservatives was not so high, a good repeatability (RSD, n = 8) of less than 1.5% for the eight preservatives was obtained. The inline dialysis-IC method was applied to the determination of the preservatives in foods and daily necessities. The preservatives were quantified without any interference. The proposed method will be useful for the determination of the preservatives in foods and daily necessities containing high concentration matrices.  相似文献   

10.
On the basis of the chromogenic reaction of chromium(VI) with 1,5-diphenylcarbohydrazide (DPC) on the surface of Polysorb C-18 beads and the sequential injection renewable surface technique (SI-RST), a highly sensitive reflect spectrophotometric method for the determination of chromium(III) and chromium(VI) was proposed. Considerations of system and flow cell design, and factors that influence the determination performance were discussed. With 300 microl of sample loaded and 0.6 mg of beads trapped, the linear response range was 0.02 - 0.5 mg l(-1) Cr(VI) with a detection limit (3 sigma) of 2.4 microg l(-1) Cr(VI). The method achieves a precision of 1.3% RSD (n = 11) and a throughput of 53 samples per hour. The determination of Cr(III) was based on the same reaction for the determination of Cr(VI) after being oxidized by (NH4)2S2O8. The precision of the oxidation method was evaluated using a 0.2 mg l(-1) Cr(III) standard, yielding an RSD of 2.5% (n = 11). The average recovery of Cr(III) oxidized was tested to be 99.1%. The proposed method was used in the simultaneous determination of Cr(VI) and Cr(III) in water samples, and the error was less than 3%.  相似文献   

11.
Fung YS  Lau KM 《Electrophoresis》2003,24(18):3224-3232
To meet the need for a new and validated analytical method for simultaneous determination of inorganic and organic acid anions in beverage drinks, a capillary zone electrophoresis (CZE) procedure had been developed based on a new background electrolyte (BGE) system containing 3 mmol/L 1,3,5-benzenetricarboxylic acid (BTA), 15 mmol/L tris(hydroxymethyl)aminomethane and 1.5 mmol/L tetraethylenepentamine (TEPA) at pH 8.4. Baseline separation of anions commonly found in beverage drinks could be achieved in less than 14 min with indirect UV detection at 240 nm. Comigration problems for hydroxycarboxylic acids could be solved using TEPA as BGE additive. The results indicate excellent repeatability for migration time (RSD, 0.27-0.67%, n = 5) and good precision for both peak height (RSD, 3.2-4.2%, n = 5) and peak area (RSD, 3.1-4.5%, n = 5). Under the optimized conditions and using corrected peak area for quantitation, an excellent linear dynamic range (with correlation coefficient > 0.997 in a concentration range from 0.005 to 2.0 mmol/L) and low detection limit (1-4 micro mol/L) were obtained for all the anions investigated. The applicability and reliability of the CE procedure developed were established by parallel method determination using established ion chromatography procedure for the analysis of inorganic and organic acid anions in orange juice and wine samples. Our CZE procedure provided a sensitive and economic technique for simultaneous determination of inorganic and organic acid anions in orange juice, red and white wine samples.  相似文献   

12.
A rapid and accurate method using reversed-phase liquid chromatography-tandem mass spectrometry interfaced with electrospray was developed for determination of acrylamide in cooked food samples. A simplified sample treatment procedure using an extraction step with acidified water without cleanup was developed. A C18 column with an aqueous formic acid-methanol mixture as the mobile phase was used under isocratic conditions. The method was validated in-house for robustness, limits of detection (LOD) and quantitation (LOQ), linearity, recovery, and accuracy both on standard and baked-product and potato flour matrixes. Good results in the low ppb level were obtained for LOD (< 15 microg/kg) and LOQ (< 25 microg/kg) of acrylamide in samples. Excellent linearity (r2 = 0.999-1.000) was established over 2 orders of magnitude by performing statistical tests. The absence of both constant and proportional systematic errors demonstrated good method accuracy. Excellent results were obtained for intraday repeatability (RSD < 1.5%) and between-day precision (RSD < 5%). Extraction recoveries from food products were calculated in the 97 +/- 3-99 +/- 2% (n = 6) range with a labeled internal standard (13C3-acrylamide). The applicability of the method to determination of acrylamide in cooked food products was demonstrated.  相似文献   

13.
用螯合树脂作吸附剂,流动注射法分离富集烧碱中铁、镍、铜,火焰原子吸收光度法测定,在120h^-1、60h^-1的采样频率下,三种元素富集倍数分别为6.5,13.5,14。方法用于工业烧碱中铁、镍、铜测定,回收率分别为96.2%、96.4%和97.4%,RSD分别为2.5%、3.6%和3.5%。  相似文献   

14.
We have developed and validated a CE-MS/MS method using an in-line SPE device (analyte concentrator, AC) to determine eight quinolones of veterinary use whose maximum residue levels in animal edible tissues are established by the EU Council Regulation 2377/90, i.e., danofloxacin, sarafloxacin, ciprofloxacin, marbofloxacin, enrofloxacin, difloxacin, oxolinic acid, and flumequine. Different parameters affecting the AC performance, such as its design (in this case frit-free), the kind of sorbent (Oasis MCX), sample pH, volume, and composition of the elution plug and injection time were studied. The method was validated using standard solutions obtaining LODs between 17 and 59 ng/L. Finally, a pressurized liquid extraction (PLE) method was developed to determine these antibiotics in chicken muscle samples. The whole analytical method was validated in terms of linearity (r2 >or= 0.992), recoveries (63-112%), repeatability and intermediate precision (RSD 相似文献   

15.
A liquid chromatographic method with luminescence detection for the determination of eight phenolic compounds is reported. The method involves postcolumn derivatization with terbium(III). This derivatization is based on the reaction between phenolics and terbium(III) to form luminescent chelates, which were determined at lamda ex 295 and lamda em 545 nm using the fluorescence mode. The long wavelength emission of lanthanide chelates can minimize interferences from background sample matrix, which usually emit at shorter wavelengths. Also, the chromatographic separation allows the individual determination of phenolics, which cannot be done using the direct measurement of the fluorescence of their corresponding terbium chelates. Dynamic ranges of the calibration graphs and detection limits, obtained with standard solutions of analytes were (microg/mL): gallic acid (0.9-40, 0.3), protocatechuic acid (0.05-7, 0.016), catechin (0.2-40, 0.07), vanillic acid (0.25-40, 0.08), p-hydroxybenzoic acid (0.8-40, 0.25), syringic acid (0.17-40, 0.05), epicatechin (0.3-40, 0.09) and salicylic acid (0.07-12, 0.02). The precision was established at two concentration levels of each analyte and expressed as the percentage of RSD with values ranging between 1.0 and 6.5%. The practical usefulness of the method was demonstrated by the analysis of white wine samples, which were diluted two-fold and directly injected into the chromatographic system. The recovery values obtained ranged between 93.3 and 108.0%.  相似文献   

16.
Fung YF  Lau KM 《Electrophoresis》2001,22(11):2192-2200
A new analytical procedure is developed using a strong complexing agent, 1,10-phenanthroline (Phen), for direct UV detection of Zn, Mn, Cu, Co, Cd, and Fe at microg/L concentrations in environmental water samples. The metal chelates formed showed different electrophoretic mobilities and solved the comigration problem for capillary electrophoresis (CE) separation of free metal ions. To obtain stable metal-Phen chelates during the capillary zone electrophoresis (CZE) run, both pre-column and on-column complexation are required and threefold excess of Phen over metal ions should be added to the sample. The optimized background electrolyte (BGE) consists of 30 mM hydroxylamine hydrochloride and 0.1% methanol at pH 3.6. Under hydrodynamic sampling, CE run at + 20 kV in 65 cm x 0.05 mm ID fused-silica column with detection at 265 nm, baseline separation, satisfactory working ranges (10 microg/L to 5.5 mg/L), sensitive detection limits (1-3 microg/L), good repeatability for migration times (relative standard deviation, RSD 0.36-0.81%, n = 5), peak area (RSD 3.2-4.2%, n = 5) and peak height (RSD 3.2-4.5%, n = 5) were obtained for the metal cations investigated. The reliability of the method was established by parallel determination using the inductively coupled plasma-atomic emission spectrometry (ICP-AES) method giving results within statistical variation. The procedure developed is shown to provide a quick, sensitive, precise, and economic method for simultaneous determination of metal cations that can form stable chelates with Phen.  相似文献   

17.
高效液相色谱法同时测定血清和尿中厚朴酚与和厚朴酚   总被引:4,自引:0,他引:4  
袁成  杜昆  朱丽青  王景祥 《色谱》2000,18(3):229-231
 建立了大鼠服用厚朴提取物后的血清中及尿中厚朴酚与和厚朴酚的高效液相色谱测定法。色谱柱填料为SpherisorbC18,流动相为甲醇-水-冰醋酸(体积比为70∶30∶1),UV检测波长为294nm,灵敏度0.005AUFS。样品用甲醇沉淀蛋白,上清液酸化后用乙酸乙酯-乙醚萃取,然后测定其中的药物浓度。血清和尿中的药物浓度与峰面积的线性关系良好,线性范围分别为0.05~2mg/L(厚朴酚)、0.025~1mg/L(和厚朴酚);精密度和重现性良好。血清中厚朴酚与和厚朴酚的平均加样回收率分别为95.6%(RSD=3.85%)和93.8%(RSD=3.95%),尿中分别为96.0%(RSD=3.83%)和94.9%(RSD=3.54%)。  相似文献   

18.
A simple, reliable and effective gas chromatography coupled with flame ionization detection method was developed for the simultaneous determination of eight components (α‐pinene, β‐pinene, myrcene, limonene, terpinen‐4‐ol, α‐terpineol, bornyl acetate and methyl‐n‐nonylketone) in Chinese medicine Houttuynia cordata and its injection. The chromatographic separation of all eight components, including undecylene as internal standard was performed on a DB‐1 column (30 m×0.25 mm, 0.25 μm). Excellent linear behaviors including herb and injection over the investigated concentration ranges were observed with the values of r2 higher than 0.9990 for all analytes. Satisfactory intra‐day and inter‐day precisions were achieved with RSD less than 2% and the average recoveries for all analytes at three different concentrations obtained were in the range of 93.4–104.4%, with RSD ranging from 1.3 to 4.1%. The proposed method was successfully applied in the simultaneous determination of these active components in H. cordata and H. cordata injection (HCI), including the intermediate product of HCI in productive process, from different pharmaceutical factories and different production batches, indicating that the method in this paper was particularly suitable for the routine analysis of HCI and its quality control in productive process.  相似文献   

19.
Deng X  Liang G  Chen J  Qi M  Xie P 《Journal of chromatography. A》2011,1218(24):3791-3798
Production and fate of taste and odor (T&O) compounds in natural waters are a pressing environmental issue. Simultaneous determination of these complex compounds (covering a wide range of boiling points) has been difficult. A simple and sensitive method for the determination of eight malodors products of cyanobacterial blooms was developed using automatic purge and trap (P&T) coupled with gas chromatography-mass spectrometry (GC-MS). This extraction and concentration technique is solvent-free. Dimethylsulfide (DMS), dimethyltrisulfide (DMTS), 2-isopropyl-3-methoxypyrazine (IPMP), 2-isobutyl-3-methoxypyrazine (IBMP), 2-methylisoborneol (MIB), β-cyclocitral, geosmin (GSM) and β-ionone were separated within 15.3 min. P&T uses trap #07 and high-purity nitrogen purge gas. The calibration curves of the eight odors show good linearity in the range of 1-500 ng/L with a correlation coefficient above 0.999 (levels=8) and with residuals ranging from approximately 83% to 124%. The limits of detection (LOD) (S/N=3) are all below 1.5 ng/L that of GSM is even lower at 0.08 ng/L. The relative standard deviations (RSD) are between 3.38% and 8.59% (n=5) and recoveries of the analytes from water samples of a eutrophic lake are between 80.54% and 114.91%. This method could be widely employed for monitoring these eight odors in natural waters.  相似文献   

20.
On-column complexation of metal ions with 2,6-pyridinedicarboxylate (2,6-PDC) to form anionic complexes enabled their separation by capillary zone electrophoresis with direct UV detection at 214 nm. Nine metal ions, Cu2+, Zn2+, Ni2+, Cd2+ Mn2+, Pb2+, Fe3+, Al3+ and Ca2+, were determined in less than 7 min using 10 mM 2.6-PDC solution containing 0.75 mM tetradecyltrimethylammonium bromide at pH 4.0. Satisfactory working ranges (20-300 microM), detection limits (3-10 microM) and good repeatability of the peak areas (RSD 2.1-4.2%, n=5) were obtained using hydrodynamic injection (30 s). The proposed method was used successfully for the determination of Mn2+, Fe3+, Al3+ and Ca2+ in groundwaters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏