首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The main factors affecting the mesopore porosity of methacrylate-ester based monolithic columns were investigated. We prepared 40 monolithic capillary columns with porosity controlled by varying the proportions of butyl methacrylate (BMA) and ethylene dimethacrylate (EDMA) monomers and of 1,4-butanediol (BUT) and 1-propanol (PROP) as the porogen solvent in the polymerisation mixtures by thermally initiated in situ polymerisation in fused-silica capillaries. Using mixture design software, we systematically varied the composition of the polymerisation mixtures to find significant factors affecting mesopore formation. Multivariate analysis of the experimental data obtained for the fabricated columns yielded a model for prediction of the mesopore porosity in monolithic beds as a function of the composition of the polymerisation mixture used to prepare polymethacrylate monolithic capillary columns. The mean absolute deviation of predicted porosities is 0.029 for most of the columns, with only eight columns showing deviations exceeding 0.050. The main factor affecting the mesopore porosity proved to be the combination of the concentration of hydrophobic monomer (BMA) and the concentration of the less-polar solvent, 1-propanol, in the porogen mixture. The proportion of mesopores in the monolithic capillary columns increases with increasing concentration of 1-propanol and with decreasing concentration ratios of the cross-linker (EDMA) to monomer (BMA) and of BUT to PROP porogenic solvents.  相似文献   

2.
Butyl methacrylate monolithic columns in 320 microm i.d. fused silica capillaries for reversed-phase capillary liquid chromatography were prepared by radical polymerization initiated thermally with azobisisobutyronitrile (AIBN). Polymerization mixture contained butyl methacrylate (BMA) as the function monomer and ethylene dimethacrylate (EDMA) as the crosslinking agent with 1,4-butanediol and 1-propanol as a binary porogen solvent. Ratio of 1,4-butanediol to 1-propanol in the porogen solvent was optimized regarding the monolithic column efficiency and performance. Total porosity, column permeability, separation impedance, Walters hydrophobicity index, retention factors, peak asymmetry factors, height equivalents to a theoretical plate and peak resolutions were used for characterization of the prepared monolithic columns. The polymerization mixture consisting of 17.8% of BMA, 21.8% of EDMA, 18.0% of 1,4-butanediol, 42.0% of 1-propanol and 0.4% AIBN generated monolithic columns of the best performance having a sufficient permeability and the lowest separation impedance. It was also demonstrated that monolithic columns of this composition exhibited good preparation reproducibility and an excellent pressure resistance when applied in capillary liquid chromatography.  相似文献   

3.
Preparation of organic polymer monolithic columns in fused silica capillaries was aimed at fast gradient separation of proteins. For this purpose, polymerization in situ procedure was optimized, using ethylene dimetacrylate and butyl metacrylate monomers with azobisisobutyronitrile as initiator of the polymerization reaction in presence of non-aqueous porogen solvent mixtures composed of 1-propanol and 1,4-butanediol. The separation of proteins in totally monolithic capillary columns was compared with the chromatography on a new type of "hybrid interparticle monolithic" capillary columns, prepared by in situ polymerization in capillary packed with superficially porous spherical beds, 37-50 microm. The "hybrid" columns showed excellent stability and improved hydrodynamic flow properties with respect to the "totally" monolithic capillary columns. The separation selectivity is similar in the two types of columns. The nature of the superficially porous layer (bare silica or bonded C18 ligands) affects the separation selectivity less significantly than the porosity (density) of the monolithic moiety in the interparticle space, controlled by the composition of the polymerization mixture. The retention behaviour of proteins on all prepared columns is consistent with the reversed-phase gradient elution theory.  相似文献   

4.
A novel monolithic capillary column (530 microm i.d.) was prepared for capillary liquid chromatography (CLC) by in situ copolymerization of octyl methacrylate (MAOE) and ethylene dimethacrylate (EDMA) in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of the contents of the porogen solvent, EDMA and the various concentration ratios of 1-propanol to 1,4-butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of monolithic capillary columns were characterized by SEM and mercury intrusion porosimetry, respectively. Chromatographic evaluations of the columns were performed under CLC mode. The results showed that good permeability and stability can be obtained under optimal experimental conditions. The separation results of some acid, neutral and basic analytes demonstrated the hydrophobicity and low affinity to basic analytes of the new column. Three metal ions, i.e. Mg(II), Zn(II) and Cd(II) were also separated under ion-pair mode on the new monolithic capillary column and the results were acceptable.  相似文献   

5.
Yu C  Svec F  Fréchet JM 《Electrophoresis》2000,21(1):120-127
Photoinitiated free radical polymerization has been used for the preparation of porous polymer monoliths within UV transparent fused silica capillaries and quartz tubes. These formats were used as models for the preparation of the separation media within channels of microfabricated devices. A mixture of ethylene dimethacrylate, butyl methacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid was polymerized in the presence of a porogenic solvent consisting of 1-propanol, 1,4-butanediol, and water at room temperature under UV irradiation. Modification of the porogen composition enables the tailoring of pore size within the broad range from ca. 100 to 4000 nm. Scanning electron micrographs confirmed the homogeneity of the porous structure of the materials prepared, even in a quartz tube with a diameter as large as 4 mm. Separation properties of the resulting capillary columns were tested in capillary electrochromatography (CEC) mode using a mixture of thiourea and eight aromatic compounds. Plate number as high as 210 000 plates/m were found for a capillary column with optimized porous properties. The monolithic columns were also able to separate mixtures of peptides.  相似文献   

6.
Monolithic capillary columns have been prepared in fused‐silica capillaries by radical co‐polymerization of ethylene dimethacrylate and butyl methacrylate in the presence of porogen solvent mixtures containing various concentration ratios of 1‐propanol, 1,4‐butanediol, and water with azobisisobutyronitrile as the initiator of the polymerization reaction. The through pores in organic polymer monolithic columns can be characterized by “equivalent permeability particle size”, and the mesopores with stagnant mobile phase by “equivalent dispersion particle size”. Increasing the concentration of propanol in the polymerization mixture diminishes the pore volume and size in the monolithic media and improves the column efficiency, at a cost of decreasing permeability. Organic polymer monolithic capillary columns show similar retention behaviour to packed alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have different methylene selectivities. Higher concentrations of propanol in the polymerization mixture increase the lipophilic character of the monolithic stationary phases. Best efficiencies and separation selectivities were found for monolithic columns prepared using 62–64% propanol in the porogen solvent mixture. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra‐column contributions.  相似文献   

7.
Monolithic capillary columns for hydrophobic interaction chromatography (HIC) have been prepared by thermally initiated, single-step in situ polymerization of mixtures of monovinyl monomers including butyl methacrylate and/or 2-hydroxyethyl methacrylate, with a divinyl crosslinker glycerol dimethacrylate or 1,4-butanediol dimethacrylate using two different porogen systems. Two porogenic solvent mixtures were used; one "hydrophilic", consisting of water, butanediol, and propanol, and one "hydrophobic," comprising dodecanol and cyclohexanol. The porous structures of the monoliths were characterized and their performance was demonstrated with a separation of a mixture of myoglobin, ribonuclease A, and lysozyme under conditions typical of HIC.  相似文献   

8.
Organic polymer monolithic capillary columns were prepared in fused-silica capillaries by radical co-polymerization of ethylene dimethacrylate and butyl methacrylate monomers with azobisisobutyronitrile as initiator of the polymerization reaction in the presence of various amounts of porogenic solvent mixtures and different concentration ratios of monomers and 1-propanol, 1,4-butanediol, and water. The chromatographic properties of the organic polymer monolithic columns were compared with those of commercial silica-based particulate and monolithic capillary and analytical HPLC columns. The tests included the determination of H-u curves, column permeabilities, pore distribution by inversed-SEC measurements, methylene and polar selectivities, and polar interactions with naphthalenesulphonic acid test samples. Organic polymer monolithic capillary columns show similar retention behaviour to chemically bonded alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have lower methylene selectivities and do not show polar interactions with sulphonic acids. The commercial capillary and analytical silica gel-based monolithic columns showed similar selectivities and provided symmetrical peaks, indicating no significant surface heterogeneities. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra-column contributions. With 0.3 mm ID capillary columns, corrections for extra-column volume contributions are sufficient, but to obtain true information on the efficiency of 0.1 mm ID capillary columns, the experimental bandwidths should be corrected for extra-column contributions to peak broadening.  相似文献   

9.
The in situ preparation of monolithic capillary columns comprising copolymers of butyl methacrylate with ethylene dimethacrylate, diethylene glycol dimethacrylate, triethylene glycol dimethacrylate, and pentaerythritol tetraacrylate using thermal polymerization within 250 microm ID capillaries and their application for micro-HPLC separations of proteins has been studied. For all crosslinkers, optimization of the porogenic mixture consisting of 1-propanol and 1,4-butanediol yielded monoliths with pore sizes above 1 microm suitable for rapid separations at low back pressure. Very good separations were achieved for a protein mixture consisting of ribonuclease A, cytochrome c, myoglobin, and ovalbumin with all tested columns.  相似文献   

10.
This work describes the fabrication of long chain alkyl methacrylate monolithic materials for use as stationary phases in capillary liquid chromatography. After capillary inner wall surface activation with 3-(trimethoxysilyl)propyl methacrylate, monoliths were formed by copolymerization of either lauryl or stearyl methacrylate (LMA or SMA) with ethylene dimethacrylate (EDMA) as crosslinker, in the presence of azobisisobutyronitrile (AIBN) as initiator and a mixture of porogenic solvents including water, 1-propanol and 1,4-butanediol. The composition of the polymerization mixture was changed in terms of monomer, crosslinker and porogen ratio composition, in order to compare the influence of these parameters. The monoliths were prepared in 320 ??m i.d. and 200 mm length capillaries. The column morphology was characterized by optical microscopy and scanning electron microscopy (SEM). Total porosity and permeability of each column were calculated using uracil as unretained material by measuring the pressure drop across the columns as a function of linear velocity. The microglobule average size for each column was also determined using Hagen?CPoiseuille equation and compared with the SEM images. As expected, a decrease of the porogen to monomer ratio corresponded to smaller microglobules and a lower total porosity. The columns were then chromatographically evaluated; good results were obtained when these capillaries were used to separate mixtures of phenols, aromatics and drug compounds.  相似文献   

11.
Monolithic capillary columns (320 microm I.D.) were prepared for capillary liquid chromatography (CLC) by radical polymerization of butylmethacrylate (BMA) and ethylenedimethacrylate (EDMA) in the presence of a porogen solvent containing propan-1-ol, butane-1,4-diol and water. The influence of the contents of the porogen solvent and EDMA in the polymerization mixture on the monolith porosity and column efficiency was investigated. The composition of the polymerization mixture was optimized to attain a minimum HETP of the order of tens of microm for test compounds with various polarities. The separation performance and selectivity of the most efficient monolithic column prepared was characterized by van Deemter curves, peak asymmetry factors and Walters hydrophobicity and silanol indices. It was demonstrated that the 320-microm I.D. monolithic column exhibited CLC separation performance similar to that observed for 100- and 150-microm I.D. monolithic columns reported in the literature; moreover, the 320-microm I.D. column was easier to operate in CLC and exhibited a higher sample loadability.  相似文献   

12.
Organic monolithic stationary phases for CEC were synthesized in situ in fused-silica capillaries. Polymerization mixtures were composed of butyl methacrylate, ethylene dimethacrylate, and [2-(methacryloyloxy)ethyl]trimethyl ammonium chloride in the presence of a porogenic solvent, using ammonium peroxodisulfate as chemical initiator, and N,N,N',N'-tetramethylethylenediamine to activate the reaction. The influence of the amount of initiator, temperature, and composition of porogenic solvent on the physical and chromatographic properties of monolithic stationary phases has been investigated. A minimum plate height of 14.5 microm was obtained at 18 wt% of 1,4-butanediol in the polymerization mixture. The produced monolithic stationary phases exhibited a good repeatability and batch-to-batch and mixture-to-mixture reproducibility, with RSD values below 5.6% in the electrochromatographic parameters studied. A comparison with columns prepared by thermal initiation with alpha,alpha'-azobisisobutyronitrile (AIBN) was also performed. The most efficient column initiated with peroxodisulfate showed better efficiencies and selectivities than that prepared with AIBN at the same composition mixture.  相似文献   

13.
A polymethacrylate‐based strong cation‐exchange capillary monolithic column was prepared by in‐situ copolymerization for the fast separation of proteins. Glycidyl methacrylate (GMA) was used as monomer, ethylenedimethacrylate (EDMA) as cross link agent and the mixture of 1‐propanol, 1,4‐butanediol and water as porogen solvent. The monolith was sulfonated using 1 mol/L Na2SO3 based on a ring opening of epoxides. The influences of the contents of the porogen solvent and GMA and the various concentration ratios of 1‐propanol to 1,4‐butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of the monolith were characterized by SEM and mercury intrusion porosimetry, respectively. Using only 1.5 cm length of this monolithic capillary column, four kinds of proteins, trypsin, cytochrome C, lysozyme (egg white) and egg albumin, were successfully separated from each other in 5 min at a high flow rate of 110 mm/s.  相似文献   

14.
Fused-silica capillary columns (100 μm I.D.) englobing a porous monolithic stationary phase were prepared by in situ copolymerization of 2-ethylhexyl methacrylate, ethylene glycol dimethacrylate and 2-acrylamido-2-methylpropanesulfonic acid (AMPS) in the presence of a porogenic mixture containing 1-propanol, 1,4 butanediol and water. The influence of the monomers ratio and the porogen solvent composition as well as the content of AMPS in the polymerization mixture on column total porosity and efficiency was investigated to attain minimum HETP values for the reversed-phase capillary electrochromatography separation of bioflavonoids. For the most promising column, the van Deemter plots, in both μ-HPLC and CEC, were also evaluated. In CEC the reduced plate height was found almost constant (1.6–2.0) within the range of linear mobile phase velocity between 0.2–2.0 mm s−1. The chemical and mechanical stabilities of the monolithic column over a wide range of buffer pH (2-10) and time were satisfactory. Furthermore, the effects of mobile phase parameters, such as buffer concentration and organic modifier content, on the electroosmotic flow were studied systematically. CEC separations of standard mixtures of polyphenols, including flavonols, flavanones and flavanones-7-O-glycosides, were accomplished in less than 8 min. The CEC separation of the major flavanone glycoside constituents in the extract from a freshly squeezed grapefruit juice was also reported.  相似文献   

15.
The enantioseparation of 2-aryloxypropionic acids by capillary electrochromatography was tested on columns with a monolithic stationary phase prepared from silanized fused-silica capillaries (100 microm I.D.) by in situ copolymerization of glycidyl methacrylate, ethylene glycol dimethacrylate and methyl methacrylate in the presence of formamide and 1-propanol as the porogen solvents. The porous chiral monolithic stationary phases were prepared by reaction of the epoxy-groups at the surface of the monolith with (+)-1-(4-aminobutyl)-(5R,8S,10R)-terguride. To attain the minimum HETP values for the enantiodiscrimination of 2-phenoxypropionic acid, the influence of the composition of polymerization solution on column total porosity and efficiency was investigated. Optimum mobile phase conditions were found for all analytes tested using acetonitrile-methanol mixtures containing triethylamine and acetic acid as the buffer components. Furthermore, the chemical and mechanical stabilities of the columns were satisfactory, allowing hundreds of analyses.  相似文献   

16.
反相毛细管整体柱的制备及其在多肽混合物分离中的应用   总被引:3,自引:3,他引:0  
谢晶鑫  毕开顺  钱小红  张养军 《色谱》2009,27(2):186-190
采用甲基丙烯酸月桂酯为基础功能单体,乙二醇二甲基丙烯酸酯为交联剂,正十二醇、1,4-丁二醇及二甲基亚砜为致孔剂,在内径为75 μm的石英毛细管内制备了具有良好机械性能及化学稳定性的反相毛细管整体柱。考察了致孔剂的种类、比例以及交联剂在单体混合物中的比例对柱压和分离效果的影响;以单体15%、交联剂15%、致孔剂70%(均为质量分数)作为优化配方,在70 ℃条件下反应24 h;并对所合成的毛细管整体柱进行了电镜表征,测试了流速、柱长与柱压的关系。结果表明,毛细管整体柱的通透性良好,可通过延长柱长的方法提高分离效果。将所制备的毛细管整体柱装于纳升级高效液相色谱仪上进行牛血清白蛋白及血浆样本的胰蛋白酶酶切液的分离,获得了比较理想的分离效果。  相似文献   

17.
Modern rigid porous polymer monoliths were conceived as a new class of stationary phases in classical columns in the early 1990s and later extended to the capillary format. These monolithic materials are typically prepared using a simple molding process carried out within the confines of the capillary. Polymerization of a mixture comprising monomers, initiator, and porogenic solvent affords macroporous materials with large through-pores that enable applications in a rapid flow-through mode. Since all the mobile phase must flow through the monolith, convection considerably accelerates mass transport within the monolithic separation medium and improves the separations. As a result, monolithic columns perform well even at very high flow rates. Various mechanisms including thermally and UV initiated free radical polymerization as well as ring opening metathesis copolymerizations were demonstrated for the preparation of monolithic capillary columns. The versatility of these preparation techniques was demonstrated by their use with hydrophobic (styrene, divinylbenzene, butyl methacrylate, ethylene dimethacrylate), hydrophilic (2-hydroxyethyl methacrylate, methacrylamide, methylenebisacrylamide), ionizable (vinylsulfonic acid, 2-acrylamido-2-methyl-propanesulfonic acid), and tailor-made (norborn-2-ene, 1,4,4a,5,8,8a-hexahydro-1,4,5,8-exo,endo-dimethanonaphthalene) monomers. Variation of polymerization conditions enables control of the porous properties of the monolith over a broad range and mediates the hydrodynamic properties of the monolithic columns. The applications of polymer-based monolithic capillary columns are demonstrated for numerous separations in the microHPLC mode.  相似文献   

18.
This work describes the preparation of polymer based monolithic materials and their use as stationary phases in capillary liquid chromatography. Multi-walled carbon nanotubes (MWCNT) were incorporated into a mixture containing benzyl methacrylate (BMA) and ethylene dimethacrylate (EDMA) as co-monomers. The optimized porogenic mixture was a ternary solution composed of cyclohexanol, 1,4-butandiol and butanol which resulted in a stable and homogeneous suspension. Six capillary columns with increasing amounts of MWCNT, from 0 to 0.4 mg mL(-1), were prepared by thermal polymerization in 0.32 mm (i.d.) and 150 mm length fused silica tubing. The chromatographic evaluation showed that the synthesized monolithic beds were mechanically stable while their porosity and permeability increased with the MWCNT content. The prepared capillary columns were tested for the separation of mixtures of ketones and phenols at an optimum flow rate of 2 μL min(-1). The results showed that incorporation of MWCNT slightly affected the retention while it enhanced the column efficiency by increasing the column efficiency by a factor of up to 9. This effect corresponded also to an improved resolution and full separation of the solutes.  相似文献   

19.
Monolithic capillary columns based on pentaerythritol triacrylate and pentaerythritol tetraacrylate were synthesized using different compositions of polymerization mixtures and different polymerization conditions. The impact of porogen type and porogen/monomer ratio on the porosity of synthesized monoliths was investigated. Porogen type appears to be the main factor influencing the separating properties of the monolithic sorbent. Using optimal polymerization conditions (porogen type, porogen/monomer ratio, reaction temperature, time etc.) monoliths with a porous structure optimized for polymer separations can be obtained. The monolithic capillary columns containing porous sorbents with optimized porosity are capable of separating 10 to 12 polystyrene standards in one chromatographic run utilizing both size exclusion chromatography and hydrodynamic chromatography separation mechanisms.  相似文献   

20.
Two methacrylate-based monolithic columns, one with a negatively charged group (sulfonic group) and another with a new monomer N,N-dimethylamino ethyl acrylate (DMAEA), were prepared and tested for the separation of basic compounds by CEC. This new monolithic stationary phase was prepared by the in situ polymerization of DMAEA with butyl methacrylate and ethylene dimethacrylate, using a ternary porogenic solvent consisting of water, 1-propanol and 1,4-butanediol. The performance of this column was evaluated by means of the analysis of a family of heterocyclic amines. Separation conditions such as pH, amount of organic modifier, ionic strength and elution mode (normal or counterdirectional flow) were studied. At the optimal running electrolyte composition, and using the counterdirectional mode, symmetrical electrochromatographic peaks were obtained, with the number of theoretical plates up to 30,000 and a good resolution between closely related peaks. The 2-acrylamido-2-methyl-1-propane-sulfonic acid column was used for CEC-MS, taking advantage of the compatibility of its elution mode (normal flow) with the MS coupling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号