首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel interface that allows normal-phase liquid chromatography to be coupled with electrospray ionization (ESI) is reported. A make-up solution of 60 mM ammonium acetate in methanol, infused at a 5 microl min(-1) flow-rate at the tip of the electrospray probe, provides a sheath liquid which is poorly miscible with the chromatographic effluent, but promotes efficient ionization of the targeted analytes. Protonated molecules generated in the ESI source were subjected to tandem mass spectrometric experiments in a triple-quadrupole mass spectrometer. The main fragmentation reactions were characterized for each analyte and specific mass spectral transitions were used to acquire chromatographic data in the multiple reaction monitoring detection mode. Results obtained during optimization of the sheath liquid composition and flow-rate suggest that the electrospray process was mainly under the control of the make-up solution, and that it forms an external charged layer around a neutral chromatographic mobile phase core. This sheath liquid interface was implemented for the analysis of some neoflavonoid compounds and its performance was evaluated. Limits of detection were established for calophillolide, inophyllum B, inophyllum P and inophyllum C at 100, 25, 15 and 100 ng ml(-1), respectively.  相似文献   

2.
A method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed for the determination of basal acetylcholine (ACh) in microdialysate from the striatum of freely moving rats. A microdialysis probe was surgically implanted into the striatum of the rats and Ringer's solution was used as the perfusion medium at a flow rate of 2 microL per minute. The samples were then analyzed off-line by LC/MS/MS experiments. The separation of ACh and choline (Ch) was carried out using reverse phase ion pair liquid chromatography with heptafluorobutyric acid as a volatile ion pairing reagent. Analytes were detected by electrospray ionization tandem mass spectrometry in the positive ion mode. The detection limit for ACh was 1.4 fmol on column, which is at least three times lower than previously reported. Three quaternary ammonium compounds in the rat brain microdialysate were also identified by tandem mass spectrometry experiments in which the unknown mass spectra were compared with standard reference compounds. These compounds were identified as carnitine, acetylcarnitine and (3-carboxypropyl)trimethylammonium. This is the first known report of the compound (3-carboxypropyl)trimethylammonium being found in rat brain.  相似文献   

3.
A liquid chromatographic/tandem mass spectrometric method was developed and validated for the determination of chloramphenicol (CAP) in royal jelly. Royal jelly samples were first denatured with lead acetate solution, and the CAP was extracted with solid-phase extraction before separation by liquid chromatography. A triple-quadrupole mass spectrometer operated in the negative electrospray ionization and selected-reaction monitoring mode was used for the detection of CAP. For method validation, royal jelly samples were fortified at CAP levels between 0.1 and 10.0 microg/kg; at these levels, recovery values (internal standard-corrected) ranged from 93.3 to 105.0%, and the within-laboratory reproducibility (relative standard deviation) was < or = 9.1%. The decision limit was 0.07 microg/kg, and the detection capability was 0.1 microg/kg.  相似文献   

4.
建立了蜂蜜样品中15种喹诺酮类兽药残留的超高效液相色谱-串联质谱检测方法。蜂蜜样品用磷酸盐缓冲溶液溶解提取后,用Oasis HLB固相萃取柱净化,超高效液相-电喷雾串联四级杆质谱检测,外标法定量。测定时用Acquity UPLC BEHC18色谱柱(50 mm×2.1 mm,1.7μm)分离,体积分数0.1%甲酸溶液-乙腈系统梯度洗脱,质谱测定采用多重反应监测(MRM)模式。15种喹诺酮类兽药的检出限均低于或等于1.0 ng/mL,回收率均在78.6%~112.9%范围内,相对标准偏差均在10%范围内。该方法各项指标均能满足国内外各项法规的要求,可用于蜂蜜样品中喹诺酮类药物残留的定量和定性检测。  相似文献   

5.
A novel liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed for the trace residue determination of chloramphenicol (CAP) in bee pollen. CAP was extracted from bee pollen with a mixture of methanol and 1% metaphosphoric acid solution, followed by a 2-stage solid-phase extraction enrichment and cleanup. The first stage involved a polymeric cartridge, and the second stage involved an alumina neutral cartridge. The LC separation was performed on a C18 column with 10 mM ammonium formate-acetonitrile (7 + 3) as the mobile phase and MS detection with negative-ion electrospray ionization. CAP-d5 was used as the internal standard. The method was validated according to Commission Decision 2002/657/EC. The calibration curves were linear between 0.1 and 5.0 ng/mL, and overall recoveries ranged from 98 to 113%. Decision limits (CCalpha) ranged from 0.05 to 0.07 microg/kg, and detection capabilities (CCbeta) ranged from 0.08 to 0.12 microg/kg. The developed method was applied to 11 samples.  相似文献   

6.
A liquid chromatography/mass spectrometry (LC/MS) method for the analysis of complex mixtures of nucleoside mono-, di- and triphosphates has been developed. A short capillary column (35mm x 0.3mm i.d.) was operated under ion-pair high-performance liquid chromatography conditions and hyphenated to (negative) electrospray (tandem) mass spectrometry. As such, the separation of 12 nucleotides was performed by a binary gradient elution using CH(3)OH/H(2)O and N,N-dimethylhexylamine (N,N-DMHA) as ion-pairing agent. The influence of different N,N-DMHA concentrations on the chromatographic and mass spectrometric performance was evaluated to achieve optimal LC/MS conditions. In addition it was demonstrated that a controlled admission of ammonium dihydrogen phosphate (NH(4)H(2)PO(4)) improved both chromatographic performance and mass spectrometric detection. Because the system was hyphenated to an orthogonal designed electrospray interface (Z-spraytrade mark), long acquisition times were possible without loss of sensitivity.  相似文献   

7.
A novel method was developed for the analysis of molecular species in neutral lipid classes, using separation by normal phase high-performance liquid chromatography, followed by detection by evaporative light-scattering and electrospray ionization tandem mass spectrometry. Monoacid standards, i.e. sterol esters, triacylglycerols, fatty acids, diacylglycerols, free sterols and monoacylglycerols, were separated to baseline on microbore 3 μm-silica gel columns. Complete or partial separation of molecular species in each lipid class permitted identification by automatic tandem mass spectrometry of ammonium adducts, produced via positive electrospray ionization. After optimization of the method, separation and identification of molecular species of various lipid classes was comprehensively tested by analysis of neutral lipids from the free lipid extract of maize flour.  相似文献   

8.
A liquid chromatography/tandem mass spectrometry method was developed for the simultaneous determination of aflatoxins (B(1), B(2), G(1), G(2)), ochratoxin A, fumonisins (B(1), B(2)), deoxynivalenol, zearalenone, T-2 and HT-2 toxins in maize. A double extraction approach, using a phosphate-buffered solution followed by methanol, was applied to achieve effective co-extraction of the 11 mycotoxins under investigation having quite different polarities and chemical structures. A new multitoxin immunoaffinity column containing antibodies for all these mycotoxins was used to clean up the extract. Detection and quantification of the 11 mycotoxins were performed by reversed-phase liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry (LC/ESI-MS/MS) using, as chromatographic mobile phase, a linear gradient of methanol/water containing 0.5% acetic acid and 1 mM ammonium acetate. Method performances were quite satisfactory for all tested mycotoxins at contamination levels close to or below the relevant EU maximum permitted or recommended levels. Limits of detection in maize ranged from 0.3 to 4.2 microg/kg. Recoveries higher than 79% were obtained for all tested mycotoxins with relative standard deviations less than 13%.  相似文献   

9.
A sensitive, rapid and simple liquid chromatography–electrospray ionization mass spectrometry (LC‐ESI‐MS/MS) method was developed for the quantitative determination of cyclobenzaprine in human plasma, to study the pharmacokinetic behavior of cyclobenzaprine capsule in healthy Chinese volunteers. With escitalopram as the internal standard (IS), sample pretreatment involved a one‐step liquid–liquid extraction using saturated sodium carbonate solution and hexane–diethyl ether (3:1, v/v). The separation was performed on an Ultimate XB‐CN column (150 × 2.1 mm, 5 µm). Isocratic elution was applied using acetonitrile–water (40:60, v/v) containing 10 m M ammonium acetate and 0.1% formic acid. The detection was carried out on a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. The ion‐pairs including m/z 276.2–216.2 for cyclobenzaprine and m/z 325.2–109.1 for IS were used for monitoring. Linear calibration curves were obtained over the range of 0.049–29.81 ng/mL with the lower limit of quantification at 0.049 ng/mL. The intra‐ and inter‐day precision showed ≤6.5% relative standard deviation. The established method laid the groundwork for follow‐up studies and provided basis for the clinical administration of cyclobenzaprine. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
建立了快速检测尿液和血浆中河豚毒素的亲水液相色谱三重四极杆质谱联用分析方法.样品经乙腈沉淀、TSK-gel Amide-80亲水色谱柱分离后,采用电喷雾串联质谱多反应监测(MRM)模式检测,基体匹配标准外标法定量.尿液和血浆样品的线性范围分别为3~500 μg/L和1~200 μg/L,加标回收率分别为96%~108%和100%~105%,相对标准偏差小于9%和16%(n=6),样品的检出限分别为1.0和0.3 μg/L(S/N=3).本方法简单、快速、灵敏、特异性强.  相似文献   

11.
In this study, an automated on-line solid-phase extraction coupled to fast liquid chromatography–tandem mass spectrometry (on-line SPE fast LC–MS/MS) method was developed for the simultaneous analysis of bisphenol A (BPA), bisphenol F (BPF), bisphenol E (BPE), bisphenol B (BPB) and bisphenol S (BPS) in canned soft drinks without any previous sample treatment. A C18 (12 μm particle size) loading column was used for the SPE on-line preconcentration before the liquid chromatography baseline separation of bisphenol compounds using a C18 Fused-Core™ (50 mm × 2.1 mm i.d.) column, which took less than 3 min. Gradient elution and heated electrospray were used to reduce matrix effect and improve ionization efficiency. To select the most intense and selective transitions, fragmentation studies were performed by multiple-stage mass spectrometry in an ion trap mass analyzer and tandem mass spectrometry in a triple quadrupole instrument, this latter instrument being used for quantitation in SRM mode. Quality parameters of the method were established and we obtained a simple, fast, reproducible (RSD values lower than 10%) and accurate (precision higher than 93%) method for the analysis of bisphenols in canned soft drinks at the ng L−1 level using matrix-matched calibration.  相似文献   

12.
A fast, sensitive and specific high-performance liquid chromatography tandem mass spectrometry method was developed for simultaneous determination of metformin and rosiglitazone in human plasma. With phenformin as an internal standard, the analysis was carried out on a C(18) column (50 mm × 2.1 mm, 3.5 μm) using a mobile phase consisting of acetonitrile-10 mM ammonium acetate (20:80, v/v). The detection was performed by tandem mass spectrometry via electrospray ionization. Linear calibration curves were obtained in the concentration of 1.054-263.5 ng/mL for rosiglitazone and 4.040-5050 ng/mL for metformin. The method was applicable to clinical pharmacokinetic study of metformin and rosiglitazone in healthy volunteers following oral administration.  相似文献   

13.
A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.  相似文献   

14.
A liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay was developed and validated to determine valproic acid in human plasma. The method involved a solid-phase extraction of valproic acid and betamethasone valerate, an internal standard, from plasma and detection using an LC-MS/MS system with electrospray ionization source in negative ion mode. Separation was achieved within 3 min on a non-porous silica column with mobile phase containing ammonium acetate and methanol. Multiple reaction monitoring was utilized for detection monitoring at 142.89-142.89 for valproic acid and 457.21-457.21 for the internal standard. The calibration curve for valproic acid was linear over the range of 0.5-150 microg/mL. The limit of detection was 0.17 microg/mL and the lower limit of quantification was 0.5 microg/mL, when 0.2 mL plasma was used for extraction. The percentage coefficient of validation for accuracy and precision (inter- and intra-day) for this method was less than 9.5% with recovery ranging from 82.3 to 86.9% for valproic acid.  相似文献   

15.
张明  唐访良  俞雅雲  陈峰  徐建芬  叶永根 《色谱》2014,32(5):472-476
建立了固相萃取-超高效液相色谱-电喷雾串联三重四极杆质谱联用技术分析水中16种全氟有机化合物的高通量检测方法。样品经WAX固相萃取柱富集和净化后,采用Waters ACQUITY UPLCTM BEH C18色谱柱,含2 mmol/L乙酸铵的甲醇和含2 mmol/L乙酸铵的水作为流动相进行梯度洗脱,质谱采用电喷雾负离子电离,多反应监测模式检测。16种全氟有机化合物在0.5~100 μg/L或1.0~100 μg/L浓度范围内线性关系良好,相关系数为0.9987~0.9999,方法的检出限为0.06~0.46 ng/L;高、中、低3个添加水平的回收率为67.6%~103%,相对标准偏差为2.94%~12.0%。结果表明,该方法灵敏、准确且检测范围广,分析速度快,是一种适于实际水样中全氟有机化合物检测分析的方法。  相似文献   

16.
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of trantinterol enantiomers in rat plasma. Diphenhydramine was employed as the internal standard. The plasma samples were prepared using liquid-liquid extraction with n-hexane-dichloromethane-isopropanol (20:10:1, v/v/v) as the extractant. Trantinterol enantiomers after pre-column derivatization using diacetyl-l-tartaric anhydride (DATAAN) were separated on a C18 column using a gradient solvent programme. The mobile phase was composed of 3 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curve for each enantiomer was obtained in the concentration range of 1-80 ng/mL, with limit of quantification (LOQ) of 1 ng/mL. The intra- and inter- precision (R.S.D.) values were below 9.6% and accuracy (R.E.) was from −2.4 to 6.2% at all quality control (QC) levels. The developed method was applied to the enantioselective pharmacokinetic study of trantinterol in rats.  相似文献   

17.
A reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (HPLC/ESI-MS) method has been developed to conclusively differentiate the epimers betamethasone and dexamethasone and various esterification products (betamethasone and dexamethasone 21-acetate, betamethasone and dexamethasone 21-phosphate, betamethasone 17-valerate, betamethasone 21-valerate and betamethasone 17,21-dipropionate) in counterfeit drugs. Good separation with baseline resolution of all epimers or isomers was obtained on a Zorbax Eclipse XDB or Luna C8 column, using a step gradient with mobile phases of 0.05 M ammonium acetate and acetonitrile. Betamethasones can also be distinguished by the relative abundance of their m/z 279 ion in the positive electrospray tandem mass spectra. The LC/MS or LC/MS/MS method developed was successfully applied to the analysis of drug product samples, i.e. creams and tablets.  相似文献   

18.
A new method for the simultaneous qualitative and quantitative determination of alkyl benzyl and dialkyl quaternary ammonium compounds (QACs) has been developed. Analysis is by reversed-phase high-performance liquid chromatography coupled with electrospray ionisation mass spectrometry. QACs are extremely amenable to the electrospray ionisation technique (limit of detection of BAC C12 homologue 3 ng ml(-1)). The selectivity of mass spectrometric detection allows simultaneous determination of benzyl and dialkyl dimethyl ammonium compounds. The method was successfully applied to the analysis of real samples (occupational hygiene sampling devices, products and swimming pool water). Structural information was obtained by MS-MS and cone voltage ion dissociation techniques. Ion dissociation enabled the structural elucidation of an unknown quaternary ammonium compound present in a commercial formulation.  相似文献   

19.
A sensitive and specific method was developed and validated for the determination of mitiglinide in human plasma using liquid chromatographic separation with electrospray ionization tandem mass spectrometric detection. Acidified plasma samples were extracted with ethyl acetate. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C(18) column with a mobile phase of methanol-10 mm ammonium acetate solution at a flow rate of 0.3 mL/min. Analytes were detected with an Agilent 6410 Triple qudrupole mass spectrometer equipped with an electrospray ionization source in positive multiple reaction monitoring mode: m/z 316.2 (precursor ion) to 298.2 (product ion) for mitiglinide and m/z 318.2 (precursor ion) to 120.2 (product ion) for the internal standard. This method was validated over a linear range of 0.5-4000 ng/mL for mitiglinide in human plasma. The lower limit of quantification (LLOQ) was 0.5 ng/mL, while a relative standard deviation (RSD) was less than 3.9%. The intra- and inter-run precision (as RSD, %) obtained from three validation runs were all less than 15%. The validated method was successfully used to analyze human plasma samples for application in pharmacokinetic studies.  相似文献   

20.
A sensitive liquid chromatography/electrospray ionisation tandem mass spectrometric (LC/ESI-MS/MS) method was developed for the analysis of acetylcholine and choline in microdialysis samples. A Ringer's solution that contains high (150 mM) concentrations of inorganic salts was used to extract acetylcholine and choline from a rat or mouse brain. The separation of acetylcholine, choline, an internal standard acetyl-beta-methylcholine, endogenous compounds and inorganic cations was achieved with hydrophilic interaction chromatography using a diol column. The eluent consisted of 20 mM ammonium formate (pH 3.3) and acetonitrile (20:80) which is favourable for the ESI process. Limits of detection (signal-to-noise (S/N) ratio = 3) of 0.02 nM (0.2 fmol) for acetylcholine and 1 nM (10 fmol) for choline were observed using standards diluted in Ringer's solution. A good linearity was obtained from the limit of quantitation: 0.1 nM (S/N ratio = 10) to 50 nM (r = 0.999) for acetylcholine and within the concentration range of 100-3500 nM (r = 0.998) for choline. The between-day repeatability of the method was good; RSD was 3.1% at 1 nM level of acetylcholine and 3.5% at 1000 nM level of choline. The recoveries for addition of 1 or 2.5 nM acetylcholine and 0.2 or 1 microM choline in microdialysis balancing samples were between 93 and 101% indicating that no suppressing endogenous compounds were co-eluting with acetylcholine or choline. The developed method was applied to the analysis of microdialysis balancing samples collected from rat and mouse brains.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏