首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry experiments can differ markedly between instruments. There have been a number of attempts to standardise the production of product ion spectra; however, a consensus on the most appropriate approach to the reproducible production of spectra has yet to be reached. We have previously reported the comparison of product ion spectra on a number of different types of instruments - a triple quadrupole, two ion traps and a Fourier transform ion cyclotron resonance mass spectrometer (Bristow AWT, Webb KS, Lubben AT, Halket JM. Rapid Commun. Mass Spectrom. 2004; 18: 1). The study showed that a high degree of reproducibility was achievable. The goal of this study was to improve the comparability and reproducibility of CID product ion mass spectra produced in different laboratories and using different instruments. This was carried out experimentally by defining a spectral calibration point on each mass spectrometer for product ion formation. The long-term goal is the development of a universal (instrument independent) product ion mass spectral library for the identification of unknowns.The spectra of 48 compounds have been recorded on eleven mass spectrometers: six ion traps, two triple quadrupoles, a hybrid triple quadrupole, and two quadrupole time-of-flight instruments. Initially, 4371 spectral comparisons were carried out using the data from eleven instruments and the degree of reproducibility was evaluated. A blind trial has also been carried out to assess the reproducibility of spectra obtained during LC/MS/MS.The results suggest a degree of reproducibility across all instrument types using the tuning point technique. The reproducibility of the product ion spectra is increased when comparing the tandem in time type instruments and the tandem in space instruments as two separate groups. This may allow the production of a more limited, yet useful, screening library for LC/MS/MS identification using instruments of the same type from different manufacturers.  相似文献   

2.
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) library which contains over 5,600 spectra of 1,253 compounds relevant in clinical and forensic toxicology has been developed using a hybrid tandem mass spectrometer with a linear ion trap. Pure compound solutions—in some cases solutions made of tablets—were prepared and 1 to 2,000 ng of each compound were injected into the system using standard reversed-phase analytical columns with gradient elution. To obtain maximum mass spectral information enhanced product ion spectra were acquired with positive and/or negative ionization at low, medium, and high collision energies and additionally applying collision energy spread. In this mode, all product ions generated by the different collision energies are trapped in the linear ion trap prior to their detection. The applicability of the library for other types of hybrid tandem mass spectrometers with a linear ion trap of the same manufacturer as well as a standard triple-quadrupole tandem mass spectrometer has been investigated with a selection of compounds. The spectra of the developed library can be used to create methods for target analysis, either screening methods or quantitative procedures by generating transitions for multiple reaction monitoring. For those procedures, suitable transitions and convenient collision energies are selected from the library. It also has been utilized to identify compounds with a multi target screening approach for clinical and forensic toxicology with a standardized and automated system. The novel aspects compared to our former library produced with a standard triple-quadrupole mass spectrometer are the enlargement of the ESI-MS/MS library and the additional acquisition of spectra with collision energy spread.  相似文献   

3.
A library of negative ion electrospray ionization mass spectra and tandem mass spectra (MS/MS) of sulfonated dyes has been developed for fast identification purposes. The uniform protocol has been elaborated and applied to the measurements of more than 50 anionic dyes. Three collision energies are selected in our protocol which ensures that at least one of them provides a suitable ratio of product ions to the precursor ion. The robustness is investigated with altered values of tuning parameters (e.g. the pressure of the nebulizing gas, the temperature and the flow rate of drying gas, and the mobile phase composition). The results of the inter-laboratory comparison of product ion mass spectra recorded on seven different tandem mass spectrometers (three ion traps, two triple quadrupoles and two hybrid quadrupole time of flight instruments) are presented for four representative anionic dyes--azo dye Acid Red 118, anthraquinone dye Acid Violet 43, triphenylmethane dye Acid Blue 1 and Al(III) metal-complex azo dye. The fragmentation patterns are almost identical for all tandem mass analyzers, only the ratios of product ions differ somewhat which confirms the possibility of spectra transfer among different mass analyzers with the goal of library formation.  相似文献   

4.
An automated liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method is presented for the screening and confirmation of 16 beta-blocking drugs in clinical and autopsy urine samples. The described method involved C(18) solid phase extraction, LC separation and MS analysis on a triple-stage quadrupole mass analyser. Samples were initially pre-screened for the presence of any beta-blocking drugs using LC/MS with selected ion monitoring. Any compounds tentatively identified as beta-blocking drugs on the basis of their LC retention time and protonated molecular ion were then automatedly subjected to a second analysis in which the relevant MS/MS product ion mass spectra were acquired. These product ion mass spectra were then automatically searched against a 400-substance mass spectral library containing previously acquired beta-blocking drugs. The results demonstrated that library search of beta-blocking drugs in urine with MS/MS product ion mass spectra was more reliable and produced fewer false negatives than library searching with mass spectra derived from single-stage quadrupole MS. The limits of identification in the MS/MS product ion scan ranged from 0.02 mg l(-1) for carvedilol to 1.2 mg l(-1) for pindolol, the majority of the values being below 0.2 mg l(-1).  相似文献   

5.
Mass spectral libraries provide a tool for identifying unknown compounds using both molecular weight and fragmentation information. Mass spectrometers with electrospray ionisation (ESI) and atmospheric chemical ionisation (ApCI) sources have the capability to produce data of this type using in-source collisionally induced dissociation (CID), and in-source CID libraries can be created. Due to the variation in electrospray source design from different instrument manufacturers, the production of reproducible in-source CID spectra that can be used in libraries for all instrument types is not a trivial task. To date, the evaluation of the production of in-source CID libraries has tended to focus on similar instruments from one manufacturer. The studies have also tended to focus on specific compound classes, with a limited molecular weight range.This report describes the findings from the investigation of protocols for the creation of mass spectral libraries using ESI in-source CID on six instruments from four different manufacturers. The overall goal was to create a spectral library for the identification of unknowns. The library could then be applied across all manufacturers' electrospray instruments.Two different experimental protocols were attempted. The first used a tuning compound to establish standard ESI source conditions, with fixed fragmentation potentials. The second involved the attenuation of the [M + H](+) ion to a known degree. A diverse range of compounds (pharmaceutical, photographic, pesticides) was tested to establish the reproducibility of the spectra on the six instruments. Both protocols produced spectra on the various instruments that in many cases were very similar. In other examples, the spectra differed not only in their relative ion abundances, but also in terms of the spectral content. Important observations regarding the effect of ion source design are also reported.The degree of spectral reproducibility was calculated off-line by comparing the five most abundant ions (20% for each ion that matches) from each spectrum on each instrument. This approach was adopted, as we do not possess a software package that met our requirements for spectral comparison. Match factors (% fit) were calculated by comparing each spectrum against the spectra recorded for the same compound and then for all other compounds, on each instrument. The % fit values derived by the off-line approach gave a clear view of the spectral reproducibility from instrument to instrument and also discriminated the spectra of the various compounds from each other. The applicability of this approach was tested using a blind trial in which several compounds were presented as unknowns, their in-source CID spectra recorded and the five-ion approach used for identification.  相似文献   

6.
A protocol for establishing standard instrument conditions for measurement of product ion MS/MS spectra from parent ions produced by electron ionization is presented. Within this protocol, the ion at m/z 231 (C5F9 +) from perfluorokerosene or perfluorotributylamine is selected as the parent ion and subjected to collision-induced dissociation. The relative intensities of product ions at m/z 69, 131, and 181 are monitored as a function of collision energy while keeping the target gas pressure constant within the range of 10?4–10?6 torr (measured), or a beam attenuation of approximately 30-70%. The collision energy at which the ion intensities for product ions at m/z 69 and 181 are equal is defined as the calibration point at that collision gas pressure; the intensity of the ion at m/z 131 is very close to this value as well. Electron ionization MS/MS spectra taken at the calibration point using two different multiquadrupole instruments show good reproducibility for several test compounds. The high degree of similarity may aid in the establishment of a MS/MS spectral library.  相似文献   

7.
Searchable MS/MS spectra libraries, constructed using the results of liquid chromatography coupled with electrospray ionization (ESI) tandem mass spectrometry (LC/MS/MS) with data-dependent acquisition on an ion trap mass spectrometer, are presented with regard to the identification and confirmation of a variety of closely related flavonoids in a set of biological samples. Flavonoids were found to exhibit a maximum amount of structurally specific MS/MS spectra at 45% of normalized collision energy on the instrument used, without wideband activation. These MS/MS spectra were then searched automatically against a 297-substance MS/MS library that contains many previously acquired spectra of standard flavonoids. The possible applications of this powerful technique to biological samples are also discussed. Daidzein and genistein were identified through the MS/MS spectra library while searching through LC/MS/MS data for plant and microbial extracts. Moreover, these compounds proved completely distinguishable from other flavonoids of closely related structures in the MS/MS spectra library, using the NIST MS search program. The applicability of the library-searchable spectra at low concentrations was demonstrated by successful identification of daidzein and genistein at 0.05 and 0.5 microg/mL, respectively.  相似文献   

8.
A library consisting of 3766 MS(n) spectra of 1743 compounds, including 3126 MS2 spectra acquired mainly using ion trap (IT) and triple-quadrupole (QqQ) instruments, was composed of numerous collections/sources. Ionization techniques were mainly electrospray ionization and also atmospheric pressure chemical ionization and chemical ionization. The library was tested for the performance in identification of unknowns, and in this context this work is believed to be the largest of all known tests of product-ion mass spectral libraries. The MS2 spectra of the same compounds from different collections were in turn divided into spectra of 'unknown' and reference compounds. For each particular compound, library searches were performed resulting in selection by taking into account the best matches for each spectral collection/source. Within each collection/source, replicate MS2 spectra differed in the collision energy used. Overall, there were up to 950 search results giving the best match factors and their ranks in corresponding hit lists. In general, the correct answers were obtained as the 1st rank in up to 60% of the search results when retrieved with (on average) 2.2 'unknown' and 6.2 reference replicates per compound. With two or more replicates of both 'unknown' and reference spectra (the average numbers of replicates were 4.0 and 7.8, respectively), the fraction of correct answers in the 1st rank increased to 77%. This value is close to the performance of established electron ionization mass spectra libraries (up to 79%) found by other workers. The hypothesis that MS2 spectra better match reference spectra acquired using the same type of tandem mass spectrometer (IT or QqQ) was neither strongly proved nor rejected here. The present work shows that MS2 spectral libraries containing sufficiently numerous different entries for each compound are sufficiently efficient for identification of unknowns and suitable for use with different tandem mass spectrometers.  相似文献   

9.
A new multi-target screening (MTS) procedure for drugs in blood and urine for toxicological analysis has been developed using a hybrid triple-quadrupole linear ion trap mass spectrometer (QTrap) for the fast detection and identification of 301 forensically important drugs, e.g. tranquilizers (benzodiazepines), hypnotics, drugs of abuse (opiates, cocaine, amphetamines, cannabinoids), antidepressants, neuroleptics, and some cardiac drugs, in one single liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. Samples were extracted either with liquid-liquid extraction or solid-phase extraction. A multiple reaction monitoring (MRM) as survey scan and an enhanced product ion (EPI) scan as dependent scan were performed in an information-dependent acquisition (IDA) experiment. Finally, drug identification was carried out by library search with a newly developed MS/MS library based on EPI spectra at three different collision energies in positive mode. The advantage of this newly developed method is the possibility to detect and identify 301 drugs in one single LC/MS/MS run.  相似文献   

10.
In contrast to libraries with highly reproducible gas chromatography electron ionization mass spectra, current liquid chromatography (LC–MS) libraries are limited to specific instrument types. Therefore, the aim of the study was to prove whether a recently developed linear ion trap (LIT) LC–MSn screening approach and reference library can be transferred to an LC–MS/MS system with a quadrupole‐LIT hybrid mass analyzer using SmileMS, a sophisticated search algorithm. The LIT reference library was built with MS² and MS³ wideband spectra recorded on a ThermoFisher LXQ LIT with electrospray ionization in positive mode and full‐scan data‐dependent acquisition (DDA). Collision parameter optimizations, including different scan types and energies, were performed on an Applied Biosystems QTRAP 4000 system using electrospray ionization in positive mode and full‐scan DDA. Modified library sets were generated to improve the detection of a compound by the used search algorithm. Additionally, 100 authentic human urine samples were screened by both systems for proof of applicability. In the applicability study, 533 compounds were detected by the LXQ and 477 by the QTRAP system using enhanced product ion scan and a modified database. The presented data showed that the LIT screening approach and reference library could be used successfully on a QTRAP instrument with some limitations. These should be overcome by further optimizations regarding DDA settings for better sensitivity and further library modifications to reduce spectra mismatches. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including “tandem-in-time” instruments; this is due to the coverage of a large range of different collision energy settings—including the very low range—which is an outstanding characteristics of the MSforID library.  相似文献   

12.
The gingerols, including [6]-, [8]-, and [10]-gingerols, a series of chemical homologs differentiated by the length of their unbranched alkyl chains, have been identified as major active components in fresh ginger rhizome. The purpose of this study was to investigate the utility of ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) as an online tool to identify and quantify these compounds in raw or processed ginger rhizome samples. Negative mode electrospray ionization (ESI) was used in MS, MS/MS and MS(n) experiments in quadrupole ion trap instruments from two different manufacturers and in high-resolution and accurate mass MS and MS/MS experiments in a Fourier transform ion cyclotron resonance mass spectrometer to elucidate the ionization and fragmentation mechanisms of these compounds in these instruments. Positive mode ESI, which generated many more fragment ions in full scan MS even under gentle ionization conditions, was also used in LC/MS and MS/MS experiments and in direct infusion MS and MS/MS experiments. Consistent and predictable ionization and fragmentation behaviors were observed for all gingerols when analyzed in the same instrument. Instruments from different manufacturers, however, had different ionization mechanisms. The major difference between instruments was their ability to form covalent dimer adducts of the gingerols. Subsequent fragmentation patterns of the precursor ions were essentially identical. These results clearly demonstrate that LC/MS instruments produce data that cannot necessarily be replicated in other laboratories, especially if those laboratories do not have the same instrument model from the same manufacturer. This presents major problems for metabolite target analysis, metabolic profiling and metabolomics investigations, which would benefit from LC/MS mass spectrum libraries as they do from GC/MS mass spectrum libraries, because such libraries may not be valid across platforms.  相似文献   

13.
The development, verification, and comparison study between LC-MS libraries for two manufacturers’ instruments and a verified protocol are discussed. Compounds in the libraries are among those considered by the U.S. EPA Office of Water as threats to drinking water including pesticides, drugs of abuse, and pharmaceuticals. The LC-MS library protocol was verified through an inter-laboratory study that involved Federal, State, and private laboratories. The results demonstrated that the libraries are transferable between the same manufacturer's product line, and have applicability between manufacturers. Although ion abundance ratios within mass spectra were shown to be different between the manufacturers’ instruments, the NIST search engine match probability was at 96% or greater for 64 out of 67 compounds evaluated.  相似文献   

14.
Structurally-related alkaloids were analyzed by electrospray ionization/multiple stage mass spectrometry (ESI/MS n ) at varying collision energies to demonstrate a conceptual algorithm, precursor ion fingerprinting (PIF). PIF is a new approach for interpreting and library-searching ESI mass spectra predicated on the precursor ions of structurally-related compounds and their matching product ion spectra. Multiple-stage mass spectra were compiled and constructed into “spectral trees” that illustrated the compounds’ product ion spectra in their respective mass spectral stages. The precursor ions of these alkaloids were characterized and their spectral trees incorporated into an MS n library. These data will be used to construct a universal, searchable, and transferable library of MS n spectra. In addition, PIF will generate a proposed structural arrangement utilizing previously characterized ion structures, which will assist in the identification of unknown compounds.  相似文献   

15.
Tandem mass spectral libraries are versatile tools for small molecular identification finding application in forensic science, doping control, drug monitoring, food and environmental analysis, as well as metabolomics. Two important libraries are the ‘Wiley Registry of Tandem Mass Spectral Data, MSforID’ (Wiley Registry MSMS) and the collection of MS/MS spectra part of the 2011 edition of the ‘NIST/NIH/EPA Mass Spectral Library’ (NIST 11 MSMS). Herein, the sensitivity and robustness of the Wiley Registry MSMS were evaluated using spectra extracted from the NIST 11 MSMS library. The sample set was found to be heterogeneous in terms of mass spectral resolution, type of CID, as well as applied collision energies. Nevertheless, sensitive compound identification with a true positive identification rate ≥95% was possible using either the MSforID Search program or the NIST MS Search program 2.0g for matching. To rate the performance of the Wiley Registry MSMS, cross‐validation experiments were repeated using subcollections of NIST 11 MSMS as reference library and spectra extracted from the Wiley Registry MSMS as positive controls. Unexpectedly, with both search algorithms tested, correct results were obtained in less than 88% of cases. We examined possible causes for the results of the cross validation study. The large number of precursor ions represented by a single tandem mass spectrum only was identified as the basic cause for the comparably lower sensitivity of the NIST library. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry can yield important structural information on organic compounds which can aid in their identification. However, differences in experimental conditions may have a strong effect on the degree of product ion formation and therefore on the features observed in product ion spectra. For this reason, a common approach for library building is the acquisition of several spectra, typically between 5 and 10, each at a different collision energy level. In this study, the use of an alternative approach was investigated, where a tuning point protocol was applied to tune the instruments in an attempt to standardise CID conditions prior to data acquisition. With this approach, the acquisition of a single mass spectrum was sufficient. The stability of the tuning point was investigated and the choice of a commercially available search package to assess spectral comparability was discussed. Finally, the product ion spectra of 33 compounds were acquired on twelve tandem-in-space instruments, including nine triple quadrupoles, one hybrid triple quadrupole linear ion trap and two quadrupole time-of-flight mass spectrometers, resulting in 2178 spectral comparisons being carried out. The results from the spectral comparisons suggest that the use of a tuning point enables the standardisation of the experimental conditions that affect the degree of product ion formation. Indeed, 84.5% of the comparisons demonstrated a good degree of spectral agreement with match scores greater than 700, which we believe is the minimum score for a tentative library match.  相似文献   

17.
Automatic function switching has been investigated for high-throughput protein identification and sequencing of peptides using direct infusion of tryptic digests on a quadrupole time-of-flight instrument. The increase in speed and the high quality of data make it a favourable technique for tandem mass spectrometry when compared to manual selection of each precursor ion; these advantages are not restricted to combined LC/MS/MS analyses for which the automatic function-switching mode was originally developed. This mode was compared to analyses performed using a slow scan of the quadrupole analyzer with repeated recording of product ion spectra. For the specific purpose of generating product ion data for sequence determination (as opposed to surveying all precursors of a selected product ion), the automatic function-switching mode was, as expected, markedly superior with respect to speed of analysis and quality of data. Furthermore, the automatic function-switching mode provides greater versatility with respect to selection of optimal collision energies.  相似文献   

18.
Liquid chromatography/ultraviolet (LC/UV) and mass spectrometry/mass spectrometry (MS/MS) libraries containing 39 phenolic compounds were established by coupling a LC and an ion trap MS with an electrospray ionization (ESI) source, operated in negative ion mode. As a result, the deprotonated [M-H]- molecule was observed for all the analyzed compounds. Using MS/MS hydroxybenzoic acid and hydroxycinnamic acids showed a loss of CO2 and production of a [M-H-44]- fragment and as expected, the UV spectra of these two compounds were affected by their chemical structures. For flavonol and flavonol glycosides, the spectra of their glycosides and aglycones produced deprotonated [M-H]- and [A-H]- species, respectively, and their UV spectra each presented two major absorption peaks. The UV spectra and MS/MS data of flavan-3-ols and stilbenes were also investigated. Using the optimized LC/MS/MS analytical conditions, the phenolic extracts from six representative wine samples were analyzed and 31 phenolic compounds were detected, 26 of which were identified by searching the LC/UV and MS/MS libraries. Finally, the presence of phenolic compounds was confirmed in different wine samples using the LC/UV and LC/MS/MS libraries.  相似文献   

19.
The inter‐instrument and inter‐laboratory transferability of a tandem mass spectral reference library originally built on a quadrupole‐quadrupole‐time‐of‐flight instrument was examined. The library consisted of 3759 MS/MS spectra collected from 402 reference compounds applying several different collision‐energy values for fragmentation. In the course of the multicenter study, 22 test compounds were sent to three different laboratories, where 418 tandem mass spectra were acquired using four different instruments from two manufacturers. The study covered the following types of tandem mass spectrometers: quadrupole‐quadrupole‐time‐of‐flight, quadrupole‐quadrupole‐linear ion trap, quadrupole‐quadrupole‐quadrupole, and linear ion trap‐Fourier transform ion cyclotron resonance mass spectrometer. In each participating laboratory, optimized instrumental parameters were gathered solely from routinely applied workflows. No standardization procedure was applied to increase the inter‐instrument comparability of MS/MS spectra. The acquired tandem mass spectra were matched against the established reference library using a sophisticated matching algorithm, which is presented in detail in a companion paper. Correct answers, meaning that the correct compound was retrieved as top hit, were obtained in 98.1% of cases. For the remaining 1.9% of spectra, the correct compound was matched at second rank. The observed high percentage of correct assignments clearly suggests that the developed mass spectral library search approach is to a large extent platform independent. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Mass spectral libraries represent versatile tools for the identification of small bioorganic molecules. Libraries based on electron impact spectra are rated robust and transferable. Tandem mass spectral libraries are often considered to work properly only on the instrument that has been used to build the library. An exception from that rule is the ‘Wiley Registry of Tandem Mass Spectral Data, MSforID’. In various studies with data sets from different kinds of tandem mass spectrometric instruments, the outstanding sensitivity and robustness of this tandem mass spectral library search approach was demonstrated. The instrumental platforms tested, however, mainly included various tandem‐in‐space instruments. Herein, the results of a multicenter study with a focus on upfront and tandem‐in‐time fragmentation are presented. Five laboratories participated and provided fragment ion mass spectra from the following types of mass spectrometers: time‐of‐flight (TOF), quadrupole–hexapole–TOF, linear ion trap (LIT), 3‐D ion trap and LIT–Orbitrap. A total number of 1231 fragment ion mass spectra were collected from 20 test compounds (amiloride, buphenin, cinchocaine, cyclizine, desipramine, dihydroergotamine, dyxirazine, dosulepin, ergotamine, ethambutol, etofylline, mefruside, metoclopramide, phenazone, phentermine, phenytoin, sulfamethoxazole, sulfamoxole, sulthiame and tetracycline) on seven electrospray ionization instruments using 18 different instrumental configurations for fragmentation. For 1222 spectra (99.3%), the correct compound was retrieved as the best matching compound. Classified matches (matches with ‘relative average match probability’ >40.0) were obtained for 1207 spectra (98.1%). This high percentage of correct identifications clearly supports the hypothesis that the tandem mass spectral library approach tested is a robust and universal identification tool. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏