首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was calculated from the solution to the Bloch equations and was utilized to determine the contrast behavior of a lesion/liver model. Theoretical and experimental results were consistent with each other. With the TI chosen to suppress the fat signal, optimization of the excitation pulse flip angle results in an increase in lesion/liver contrast or allows reduction in imaging time which, in turn, can be traded for an increased number of averages. This, in normal volunteers, improved spleen/liver contrast-to-noise ratio (9.0 vs. 5.7, n = 8, p less than 0.01) and suppressed respiratory ghosts by 33% (p less than 0.01). Reducing or increasing the inversion pulse from 180 degrees results in shorter TI needed to null the signal from the tissue of interest. Although this decreases the contrast-to-noise ratio, it can substantially increase the number of sections which can be imaged per given TR in conventional IR imaging or during breathold in the snapshot IR (turboFLASH) technique. Thus, the optimization of RF pulses is useful in obtaining faster IR images, increasing the contrast and/or increasing the number of imaging planes.  相似文献   

2.
A study was undertaken to assess the use of excitation flip angles greater than 90° for T1 weighted spin-echo (SE) imaging with a single 180° refocusing pulse and short TR values. Theoretical predictions of signal intensity for SE images with excitation pulse angles of 90–180° were calculated based on the Bloch equations and then measured experimentally from MR images of MnCl2 phantoms of various concentrations. Liver signal-to-noise ratios (SNR) and liver-spleen contrast-to-noise ratios (CNR) were measured from breathhold MR images of the upper abdomen in 16 patients using 90 and 110° excitation flip angles. The theoretical predictions showed significant improvements in SNR with excitation flip angles >90°, which were more pronounced at small TR values. The phantom studies showed reasonably good agreement with the theoretical predictions in correlating the excitation pulse angle with signal intensity. In the human imaging studies, the 110° excitation pulse angle resulted in a 7.4% (p < .01) increase in liver SNR and an 8.2% (p = .2) increase in liver-spleen CNR compared to the 90° pulse angle at TR = 275 ms. Increased signal intensity resulting from the use of large flip angle excitation pulses with a single echo SE pulse sequence was predicted and confirmed experimentally in phantoms and humans.  相似文献   

3.
The purpose of this study was to evaluate the alterations of diluted molarity of contrast media to emit the maximum signal intensity by changing the parameters of pulse sequences. The phantom was developed by diluting the magnetic resonance imaging (MRI) T1 contrast medium. The phantom images were obtained by 1.5 and 3.0 T MRI systems. We conducted Pearson’s analysis to reveal the correlation of the signal-to-noise ratio (SNR)90%, the change of the concentration range of the contrast media which shows over 90% SNR, with changing the parameters of T1 effect pulse sequences in both 1.5 and 3.0 T imaging. As the flip angle increased, the SNR increased for all contrast media in magnetization-prepared rapid gradient echo and two-dimensional fast low angle shot pulse sequences at 1.5 and 3.0 T. Although the SNR increased until 30°, the SNR was almost the same over 30° in volumetric interpolated breath-hold examination at 1.5 and 3.0 T. The minimum contrast molarity of the representing SNR90% was decreased according to the increasing time to repeat in spin echo. The present study revealed that the high concentration technique of contrast media on three pulse sequences (VIBE, MPRAGE, and 2D FLASH) could be useful to obtain images with better SNR.  相似文献   

4.
在反转恢复测试中磁化矢量的演化特征:辐射阻尼效应   总被引:1,自引:0,他引:1  
在强辐射阻尼存在下,水样(90% H2O in D2O)的反转恢复实验表明:当两脉冲的相位相差180°且反转脉冲角<180°时,或两脉冲相位一致但反转脉冲角>180°时,在检测期观测到的信号强度将不发生从负极大值到正极大值的突变;在同样的条件下,如果存在频率偏置,信号强度存在波动,即beating效应.只有当两脉冲的相位一致而反转脉冲角<180°时,或两脉冲的相位相差180°但反转脉冲角>180°时,在检测期信号强度才发生突变,即jumping效应.这些现象都可通过辐射阻尼理论予以合理地解释.另外,在检测期当磁化矢量运动到-z轴附近(对应于τ=Trdln{tan[(π±δ)/2]}),信号强度与理论预计的偏差实际上与T1弛豫效应有关.  相似文献   

5.
Stimulated-echo acquisition mode (STEAM) is a key pulse sequences in MRI in general, and in cardiac imaging in particular. Fat suppression is an important feature in cardiac imaging to improve visualization and eliminate off-resonance and chemical-shift artifacts. Nevertheless, fat suppression comes at the expense of reduced temporal resolution and signal-to-noise ratio (SNR). The purpose of this study is to develop an efficient fat suppression method (Spectrally-Presaturated Modulation) for STEAM-based sequences to enable imaging with high temporal-resolution, high SNR, and no increase in scan time. The developed method is based on saturating the fat magnetization prior to applying STEAM modulation; therefore, only the water-content of the tissues is modulated by the sequence, resulting in fat-suppressed images without the need to run the fat suppression module during image acquisition. The potential significance of the proposed method is presented in two STEAM-based cardiac MRI applications: complementary spatial-modulation of magnetization (CSPAMM), and black-blood cine imaging. Phantom and in vivo experiments are conducted to evaluate the developed technique and compare it to the commonly implemented chemical-shift selective (CHESS) and water-excitation using spectral-spatial selective pulses (SSSP) fat suppression techniques. The results from the phantom and in vivo experiments show superior performance of the proposed method compared to the CHESS and SSSP techniques in terms of temporal resolution and SNR. In conclusion, the developed fat suppression technique results in enhanced image quality of STEAM-based images, especially in cardiac applications, where high temporal-resolution is imperative for accurate measurement of functional parameters and improved performance of image analysis algorithms.  相似文献   

6.
Conventional "proton density" and "T2-weighted" spin-echo images are susceptible to motion induced artifact, which is exacerbated by lipid signals. Gradient moment nulling can reduce motion artifact but lengthens the minimum TE, degrading the "proton density" contrast. We designed a pulse sequence capable of optimizing proton density and T2-weighted contrast while suppressing lipid signals and motion induced artifacts. Proton density weighting was obtained by rapid readout gradient reversal immediately after the excitation RF pulse, within a conventional spin-echo sequence. By analyzing the behavior of the macroscopic magnetization and optimizing excitation flip angle, we suppressed T1 contribution to the image, thereby enhancing proton density and T2-weighted contrast with a two- to four-fold reduction of repetition time. This permitted an increased number of averages to be used, reducing motion induced artifacts. Fat suppression in the presence of motion was investigated in two groups of 8 volunteers each by (i) modified Dixon technique, (ii) selective excitation, and (iii) hybrid of both. Elimination of fat signal by the first technique was relatively uniform across the field of view, but it did not fully suppress the ghosts originating from fat motion. Selective excitation, while sensitive to the main field inhomogeneity, largely eliminated the ghosts (0.21 +/- 0.05 vs. 0.29 +/- 0.06, p less than 0.01). The hybrid of both techniques combined with bandwidth optimization, however, showed the best results (0.17 +/- 0.04, p less than 0.001). Variable flip-angle imaging allows optimization of image contrast which, along with averaging and effective fat suppression, significantly improves gradient- and spin-echo imaging, particularly in the presence of motion.  相似文献   

7.
Relaxation effects in the quantification of fat using gradient echo imaging   总被引:4,自引:0,他引:4  
Quantification of fat has been investigated using images acquired from multiple gradient echoes. The evolution of the signal with echo time and flip angle was measured in phantoms of known fat and water composition and in 21 research subjects with fatty liver. Data were compared to different models of the signal equation, in which each model makes different assumptions about the T1 and/or T2* relaxation effects. A range of T1, T2*, fat fraction and number of echoes was investigated to cover situations of relevance to clinical imaging. Results indicate that quantification is most accurate at low flip angles (to minimize T1 effects) with a small number of echoes (to minimize spectral broadening effects). At short echo times, the spectral broadening effects manifest as a short apparent T2 for the fat component.  相似文献   

8.
A new periodic pulse sequence employing weak excitation is presented. This type of sequence drives the system into a steady-state with periodic time evolution from which the data can be reconstructed to a spectrum. It is demonstrated that the frequency response of such a sequence can be analyzed using perturbation methods and linear system analysis. A mathematical framework is proposed allowing the frequency response to be tailored by weighting a periodic flip function. The weak excitation level used implies very low specific absorption rates while generating a highly frequency selective signal in the order of 1/T2 with signal strengths comparable to those obtainable with conventional large flip angle balanced steady-state free precession techniques. The concept is illustrated with phantom experiments and in vivo feasibility of water fat separation is shown on human knee images.  相似文献   

9.
The three-dimension Fast Low Angle SHot Magnetic Resonance Imaging (3D FLASH) sequence has been widely adopted in medical diagnostic imaging because of its availability, simplicity, and high spatial resolution. To improve the quality of structural brain images acquired with the 3D FLASH sequence, we developed a parameter optimization scheme and image inhomogeneity correction methods. The optimal imaging parameters were determined by maximizing gray-matter and white-matter CNR efficiency. Compared to protocols based on published parameters, applying the proposed optimal imaging parameters increased CNR efficiency by > 10%. Image inhomogeneity, including signal and CNR inhomogeneity, was corrected by the choice of an optimal flip angle, estimated transmit function, and estimated receive sensitivity. As a result, our optimization and image inhomogeneity correction greatly improved the quality of images acquired with the 3D FLASH sequence.  相似文献   

10.
A new method of solvent suppression is described, based on presaturation in combination with volume selection; the name “FLIPSY” is proposed for this sequence. A low-flip-angle pulse is used for excitation, immediately followed by two 180° pulses, each of which is independently phase cycled through Exorcycle. The phase-cycled inversion pulses achieve volume selection in a way similar to the widely used 1D NOESY sequence, thereby largely eliminating any residual “hump” signal from the solvent. The two 180° pulses combine to produce a net 360° rotation forzmagnetization and either a 180° or a 360° rotation for transverse magnetization, depending on the step in the phase cycle. This allows the overall flip angle of the sequence to be controlled by adjusting the length of the initial excitation pulse. It is demonstrated that this property allows one to choose freely a suitable compromise between signal strength and integral accuracy when using FLIPSY, just as when using single-pulse excitation. Such a choice cannot be made when using 1D NOESY, since the effective flip angle in that experiment is always 90°. The application of FLIPSY to recording LC-NMR spectra is demonstrated.  相似文献   

11.
The osteochondral junction (OCJ) of the knee joint is comprised of multiple tissue components, including a portion of the deep layer cartilage, calcified cartilage, and subchondral bone. The OCJ is of increasing radiological interest as it may be relevant in the early pathogenesis of osteoarthritis (OA). Due to its short transverse relaxation, the OCJ is invisible to clinical MR sequences. The purpose of this study was to develop a fast 3D T1-weighted ultrashort echo time cones sequence with fat saturation (FS-UTE-Cones) for high resolution and high contrast imaging of the OCJ on a clinical 3T scanner. First, numerical simulations were performed to investigate how the flip angle affected the signal intensities and contrasts of both short and long T1 tissues. The results from these simulations demonstrated that higher short T1 contrast could be achieved with higher flip angle. Next, T1 relaxation was measured for the different layers of a human patellar cartilage sample, and the results showed that the deepest layer had a significantly shorter T1 value than other layers. Finally, a healthy knee joint was scanned with different flip angles and the OCJ was highlighted in the T1-weighted FS-UTE-Cones sequence using a flip angle greater than 20°. The clinical T2-weighted and proton density-weighted FSE sequences were also included for comparison, revealing a dark OCJ region. Representative T1-weighted FS-UTE-Cones images of the whole knee of a healthy volunteer showed high signal intensity bands in the OCJ regions of the patella, femur, and tibia. On the other hand, T1-weighted FS-UTE-Cones imaging of the knee joints of OA patients revealed regions with reduction or loss of these high signal intensity bands in the OCJ regions, indicating abnormal OCJ tissue composition. The proposed 3D T1-weighted FS-UTE-Cones sequence with a 3-min scan time may be very useful for demonstrating the involvement of the OCJ regions in early OA.  相似文献   

12.
A retrospective analysis of clinical imaging using 2DFT SSFP at 0.14 T is presented. The technique's potential for tissue characterization and its utility for clinical diagnosis were tested by both in vitro measurements of various tissues and in vivo clinical images. Different pulse angles not only influenced image contrast, but also helped characterize lesions, particularly those containing fat. In addition, the pulse angle changed the signal from venous flow perpendicular to the imaged slice. The slow flow sensitivity of the 2DFT SSFP technique was demonstrated in the detection of CSF motion. Rapid SSFP offers flow sensitivity and adequate lesion detecting ability, along with high patient throughput.  相似文献   

13.
An action of radiation force induced by ultrasonic beam in waterlike media such as biological tissues (where the shear modulus is small as compared to the bulk compressibility) is considered. A new, nondissipative mechanism of generation of shear displacement due to a smooth (nonreflecting) medium inhomogeneity is suggested, and the corresponding medium displacement is evaluated. It is shown that a linear primary acoustic field in nondissipative, isotropic elastic medium cannot excite a nonpotential radiation force and, hence, a shear motion, whereas even smooth inhomogeneity makes this effect possible. An example is considered showing that the generated displacement pulse can be significantly longer than the primary ultrasound pulse. It is noted that, unlike the dissipative effect, the nondissipative action on a localized inhomogeneity (such as a lesion in a tissue) changes its sign along the beam axis, thus stretching or compressing the focus area.  相似文献   

14.
The origin of spin locking image artifacts in the presence of B(0) and B(1) magnetic field imperfections is shown theoretically using the Bloch equations and experimentally at low (omega(1) < Delta omega(0)), intermediate (omega(1) approximately Delta omega(0)) and high (omega(1) > Delta omega(0)) spin locking field strengths. At low spin locking fields, the magnetization is shown to oscillate about an effective field in the rotating frame causing signature banding artifacts in the image. At high spin lock fields, the effect of the resonance offset Deltao mega(0) is quenched, but imperfections in the flip angle cause oscillations about the omega(1) field. A new pulse sequence is presented that consists of an integrated spin echo and spin lock experiment followed by magnetization storage along the -z-axis. It is shown that this sequence almost entirely eliminates banding artifacts from both types of field inhomogeneities at all spin locking field strengths. The sequence was used to obtain artifact free images of agarose in inhomogeneous B(0) and B(1) fields, off-resonance spins in fat and in vivo human brain images at 3 T. The new pulse sequence can be used to probe very low frequency (0-400 Hz) dynamic and static interactions in tissues without contaminating B(0) and B(1) field artifacts.  相似文献   

15.
Factors influencing contrast in fast spin-echo MR imaging.   总被引:5,自引:0,他引:5  
Multi-echo pulse sequences for producing T2-weighted images in much reduced imaging times have recently been developed for routine clinical use. A number of recent articles have described the contrast obtained with fast spin-echo (FSE) sequences and have generally indicated that they depict tissues very similarly to conventional spin-echo (SE) imaging. There are, however, some important differences in contrast between some tissues in FSE images. This work presents a detailed study of the contrast obtained with FSE imaging sequences and examines the image sequence and tissue parameters which influence contrast. The use of multiple refocusing pulses produces several subtle effects not seen in conventional SE imaging sequences, and in this study the precise nature and extent of such effects are described. The relative contributions to image contrast of magnetization transfer, the decoupling of J-modulation effects, the production of stimulated echoes and direct saturation effects, of diffusion and of the effects of the differential attenuation of different spatial frequencies, are each quantified. The mechanisms responsible for the brighter fat signal seen in FSE images, as well as the loss of signal from some other tissues, are explained. Computer simulations, phantom experiments, and clinical images are all used to support the conclusions.  相似文献   

16.
Non-invasive in vivo marbling quantification helps owners to choose the optimum nutritional management for growing cattle and buyers to more precisely evaluate grown cattle at auctions. When using time-domain proton nuclear magnetic resonance (NMR) relaxometry, it is possible to quantify muscle and fat separately by taking advantage of the difference in the spin–spin relaxation time (T2) between water molecules in muscles and fat molecules, which would contribute to the non-invasive and objective determination of marbling scores. With this in mind, we developed a prototype NMR scanner (4.1 MHz for protons) using an original single-sided magnetic circuit and a plane radio frequency (RF) coil for use in the non-invasive quantification of water and fat in live cattle. The sensed region of the developed scanner is compact and almost cubical (19 × 19 × 16 mm3) while the investigation depth (the distance from the RF coil to the center of the sensed region) has been lengthened to 30 mm, which is sufficient for the in vivo trapezius muscle measurement of live cattle. Measurements of 17 samples of beef meat blocks kept at 39 °C were taken in a laboratory to successfully obtain the calibration lines used to convert the NMR signals into water and fat weight fractions at correlation coefficients in excess of 0.9. We also showed that each meat sample could be measured in about 10 s with a measurement error as small as approximately 10 wt%. Accordingly, we believe that our prototype scanner would be useful for in vivo marbling measurements of live cattle trapezius muscles.  相似文献   

17.
This work explores slice profile effects in 2D slice-selective gradient-echo MRI of hyperpolarized nuclei. Two different sequences were investigated: a Spoiled Gradient Echo sequence with variable flip angle (SPGR-VFA) and a balanced Steady-State Free Precession (SSFP) sequence. It is shown that in SPGR-VFA the distribution of flip angles across the slice present in any realistically shaped radiofrequency (RF) pulse leads to large excess signal from the slice edges in later RF views, which results in an undesired non-constant total transverse magnetization, potentially exceeding the initial value by almost 300% for the last RF pulse. A method to reduce this unwanted effect is demonstrated, based on dynamic scaling of the slice selection gradient. SSFP sequences with small to moderate flip angles (<40°) are also shown to preserve the slice profile better than the most commonly used SPGR sequence with constant flip angle (SPGR-CFA). For higher flip angles, the slice profile in SSFP evolves in a manner similar to SPGR-CFA, with depletion of polarization in the center of the slice.  相似文献   

18.
Significant artifacts arise in T(1rho)-weighted imaging when nutation angles suffer small deviations from their expected values. These artifacts vary with spin-locking time and amplitude, severely limiting attempts to perform quantitative imaging or measurement of T(1rho) relaxation times. A theoretical model explaining the origin of these artifacts is presented in the context of a T(1rho)-prepared fast spin-echo imaging sequence. Experimentally obtained artifacts are compared to those predicted by theory and related to B(1) inhomogeneity. Finally, a "self-compensating" spin-locking preparatory pulse cluster is presented, in which the second half of the spin-locking pulse is phase-shifted by 180 degrees. Use of this pulse sequence maintains relatively uniform signal intensity despite large variations in flip angle, greatly reducing artifacts in T(1rho)-weighted imaging.  相似文献   

19.
BackgroundIn B1 encoded MRI, a realistic non-linear phase RF encoding coil will generate an inhomogeneous B1 field that leads to spatially dependent flip angles. The non-linearity of the B1 phase gradient can be compensated for in the reconstruction, but B1 inhomogeneity remains a problem. The effect of B1 inhomogeneity on tip angles for conventional, B0 encoded MRI, may be minimized using composite pulses. The objective of this study was to explore the feasibility of using composite pulses with non-linear RF phase encoding coils and to identify the most appropriate composite pulse scheme.MethodsRF encoded signals were simulated via the Bloch equation for various symmetric, asymmetric and antisymmetric composite pulses. The simulated signals were reconstructed using a constrained least squares method.ResultsRoot mean square reconstruction errors varied from 6% (for an asymmetric composite pulse) to 9.7% (for an antisymmetric composite pulse).ConclusionAn asymmetric composite pulse scheme created images with fewer artifacts than other composite pulse schemes in inhomogeneous B0 and B1 fields making it the best choice for decreasing the effects of spatially varying flip angles. This is contrary to the conclusion that antisymmetric composite pulses are the best ones to use for spin echo sequences in conventional, B0 encoded, MRI.  相似文献   

20.
程峰  王育竹 《中国物理 B》2012,21(7):70309-070309
We analysed the influence of inhomogenous microwave field on the coherence of atom ensembles. Two methods were proposed to suppress the dephasing generated by the inhomogenous Rabi frequency. One of them was realized by spin echo, and the other one was based on the identical spin rotation effect. The results of calculation showed that the contrast of signal acquired in experiment can be improved by the two methods. Their advantages and drawbacks were discussed. We hope they could be used to improve the contrast of experimental signal in the situation that the microwave fields are very inhomogenous. Finally, we discussed the case of continuous working microwave field and showed that the dipole force raised with the inhomogeneity can be eased by spin flip.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号