首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Tian K  Qi S  Cheng Y  Chen X  Hu Z 《Journal of chromatography. A》2005,1078(1-2):181-187
In this paper, a micellar electrokinetic chromatographic (MEKC) method using ionic liquid as modifier for the quantification of the active components of lignans found in the medicinal herbs Schisandra species was developed for the first time. Preliminary investigations employing sodium dodecyl sulfate (SDS) as surfactant did not lead to the necessary resolution of the studied compounds, the addition of ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM-BF4) to the SDS micellar system resulted in the complete separation of all the compounds. The effects on the separation by several parameters such as BMIM-BF4 and SDS concentration, applied voltage, background electrolyte pH and concentration, were evaluated. Under the optimal conditions (5 mM borate-5 mM phosphate buffer in the presence of 20 mM SDS and 10 mM BMIM-BF4, pH 9.2, applied voltage 25 kV and detection at 254 nm), the method successfully applied to the determination of lignans in extracts of Schisandra chinensis (Turcz.) Baill. and Schisandra henryi C.B. Clarke in less than 13 min. The separation mechanism was also discussed.  相似文献   

2.
A micellar electrokinetic chromatography method was developed to simultaneously analyse commonly used food additives. The additive mixture, comprising propyl gallate, octyl gallate, dodecyl gallate, butylated hydroxyanisole, butylated hydroxytoluene, tertiary butylhydroquinone, p-hydroxybenzoic acid methyl ester, p-hydroxybenzoic acid ethyl ester, benzoic acid, sorbic acid, saccharin, aspartame and acesulfame-K, was not resolved using single surfactant micellar systems consisting of sodium dodecyl sulfate (SDS), sodium cholate (SC) or sodium deoxycholate (SDC). The separation of these additives using mixed micellar systems, involving SDS/SC, SDS/SDC and SC/SDC, was investigated. Organic solvents were added to the mixed micellar phases to optimise the separation. The mixture was successfully separated using a 20 mM borate buffer with 35 mM SC, 15 mM SDS and 10% methanol added at pH 9.3. Additives in cola beverages and low-joule jam were investigated and quantified using this method.  相似文献   

3.
Capillary electrophoresis with UV detection was used to separate tramadol (TR), a centrally acting analgesic, and its five phase I (M1, M2, M3, M4, M5) and three phase II metabolites (glucuronides of M1, M4 and M5). Several factors were evaluated in optimisation of the separation: pH and composition of the background electrolyte and the influence of a micellar modifier, sodium dodecyl sulfate. Baseline separation of TR and all the analytes was obtained with use of 65 mM tetraborate electrolyte solution at pH 10.65. The lowest concentrations of the analytes that could be detected were below 1 microM for the O-methylated, below 2 microM for the phenolic and ca. 7 microM for the glucuronide metabolites. The suitability of the method for screening of real samples was tested with an authentic urine sample collected after a single oral dose (50 mg) of TR. After purification and five-fold concentration of the sample (solid-phase extraction with Oasis MCX cartridges), the parent drug TR and its metabolites M1, M1G, M5 and M5G were easily detected, in comparison with standards, in an interference-free area of the electropherogram. Diastereomeric separation of TR glucuronides in in vitro samples was achieved with 10 mM ammonium acetate-100 mM formic acid electrolyte solution at pH 2.75 and with basic micellar 25 mM tetraborate-70 mM SDS electrolyte solution at pH 10.45. Both separations showed that glucuronidation in vitro produces glucuronide diastereomers in different amounts. The authentic TR urine sample was also analysed by micellar method, but unambiguous identification of the glucuronide diastereomers was not achieved owing to many interferences.  相似文献   

4.
The separation of four benzodiazepines (Flurazepam, Flunitrazepam, Clobazam and Clorazepate) in pharmaceutical products by micellar electrokinetic chromatography (MEKC) is described. It was carried out at 25 degrees C and 25 kV by using a 57 cm (50 cm to the detector)x75 mum i.d. fused silica capillary and a 15 mM borate buffer (pH 9.2), 35 mM sodium dodecylsulfate (SDS) and 35 mM sodium deoxycholate water solution. Under these conditions, the analysis was performed in 8 min with acceptable limits of quantification (between 3 and 5 mg l(-1)). The method has been applied for quantifying these benzodiazepines in serum and different commercial formulations with recoveries near 100%.  相似文献   

5.
Two capillary electrophoretic methods, a micellar electrokinetic electrophoretic (MEKC) one and a capillary zone electrophoretic (CZE) one, were developed for the separation of 12 constituents in Artemisiae Capillaris Herba. Detection at 254 nm with 20 mM sodium dodecyl sulfate and 20 mM sodium borate buffer (pH 9.82) in MEKC or with 25 mM sodium borate and 6.75 mg/ml 2,3,6-tri-O-methyl-beta-cyclodextrin buffer in CZE was found to be the most suitable approach for this analysis. Within 42 min, the MEKC method could successfully separate 12 authentic constituents, whereof chlorogenic acid, however, appeared as a broad and split peak, and capillarisin and chlorogenic acid overlapped partially with other coexisting substances in crude extract of the herb. The CZE method could completely overcome these problems and was used to determine the amounts of capillarisin, chlorogenic acid, scopoletin and caffeic acid in the extract. The effect of buffers on the constituent separation and the validation of the two methods were discussed.  相似文献   

6.
Meng P  Fang N  Wang M  Liu H  Chen DD 《Electrophoresis》2006,27(16):3210-3217
Cation-selective exhaustive injection (CSEI) is used as an on-line concentration method for the high-sensitivity analysis of illicit amphetamines using CE. Optimum conditions for the determination of amphetamine, methamphetamine and methylenedioxy-methamphetamine were investigated. Sodium dodecyl sulfate (25 mM) in 100 mM phosphate buffer (pH 2.9) with 20% methanol as organic additive was used as the background electrolyte for CE separation. The LOD, based on an S/N of 3:1, was about 0.01 microg/mL using normal capillary micellar electrokinetic chromatography, while by using CSEI in combination with micellar sweeping the sensitivity increased up to 1000-fold with the LOD lower than 50 pg/mL. The reproducibility of CSEI combined with micellar sweeping for analyzing amphetamines was satisfactory (relative standard deviation around 10% by using area ratios against an internal standard). This method is highly sensitive and can be used to analyze trace amount amphetamines in human hair.  相似文献   

7.
Gong S  Liu F  Li W  Gao F  Gao C  Liao Y  Liu H 《Journal of chromatography. A》2006,1121(2):274-279
In this study, the separation of 13 homologous stick-like hydrophobic solutes, i.e., biphenyl nitrile derivatives, by organic-solvent-based micellar electrokinetic chromatography (MEKC) was investigated in terms of separation medium composition, species and concentration of surfactant, other additives, separation voltage and temperature. The results showed that the 13 strong hydrophobic compounds were baseline separated in 25 min with a repeatability of less than 1.3% (RSD) for migration time. The separation medium was a mixture of methanol, 2-propanol and water (58.5:10:31.5), containing 150 mM cetyltrimethylammonium bromide (CTAB) and 20 mM sodium borate. Variety of solvent composition, temperature and applied voltage all showed remarkable effect on the separation. The organic-solvent-based MEKC method proved to be superior to the aqueous MEKC and microemulsion electrokinetic chromatography (MEEKC) methods for the separation of strongly hydrophobic compounds.  相似文献   

8.
In order to use micellar electrokinetic chromatography to determine the proteolytic activity of different proteinases simultaneously present in physiological fluids, the technique must be able to separate mixtures of substrates with closely related structures. In an attempt to determine the best electrophoretic conditions for resolving six p-nitroanilide peptides used as synthetic substrates of the elastolytic enzymes (human neutrophil elastase, cathepsin G, Pseudomonas aeruginosa elastase) most commonly involved in pulmonary diseases, we investigated the efficiency of ionic and nonionic surfactants in achieving the separation of this complex mixture. The results presented here show that, of all the electrophoretic systems tested, 30 mM sodium tetraborate, pH 9.3, containing 25 mM Brij 35 as micellar agent offered the best performance; the separation efficiency of peptides is greater than that obtained with other reagents and all peaks are baseline resolved and unambiguously identifiable. Analysis of the micelle-solute interaction with the surfactants investigated allowed better definition of the mechanism involved in the distribution of these peptides to the micelles and identification of some structural features that determined the magnitude of the micelle peptide complex formation.  相似文献   

9.
Protamines are a group of highly basic peptides that are sometimes added to insulin formulations to prolong the pharmacological action. In this study, different methods were investigated to identify protamine in insulin formulations. Capillary electrophoresis in aqueous and non‐aqueous media was tested to separate these peptides with very close amino acid sequences. Different buffers (phosphate or formate, both acidified) and various additives (principally negatively charged and neutral surfactants) were investigated to optimize peptide separation. Finally, a micellar electrokinetic capillary chromatography method using a capillary of 120 cm effective length and an aqueous background electrolyte made up of 100 mM phosphate buffer (pH 2) and 50 mM Thesit® gave the best results, providing the separation of the four major protamine peptides within 25 min.  相似文献   

10.
This study details the development and validation of an optimized method with micellar electrokinetic chromatography for the analysis of clindamycin. The method uses a mixed micellar phase containing anionic sodium dodecylsulfate (SDS) and non ionic Brij 35 on an untreated fused-silica capillary. The influences of buffer concentration, pH, SDS, Brij 35 and organic modifier were investigated. Special attention was given to the role of the non ionic Brij 35 in the mixed micellar system. Optimization with a central composite design resulted in optimal separation conditions: background electrolyte containing 25 mM sodium tetraborate pH 7.75, 90 mM SDS, 14 mM Brij 35 and 21% acetonitrile. The applied voltage was 15 kV and the capillary temperature 15 degrees C. The method was robust and gave good linearity and repeatability. The limits of detection and quantitation were 0.05 and 0.15%, respectively, relative to a 2.5 mg/ml clindamycin solution. Two commercial bulk products were analysed with this system.  相似文献   

11.
A new chiral derivatizing reagent, dehydroabietylisothiocyante (DHAIC), was synthesized and used for the enantiomeric separation of chiral compounds in capillary electrophoresis (CE). The synthetic route to obtain DHAIC is described. The separation conditions for the chiral separation of several chiral compounds, such as protein amino acids and chiral drug DOPA were optimized. Best results for the chiral separation of DHAIC derivatized amino acids and DOPA were obtained in a running buffer consisted of 50 mM borate (pH 9.5), 5 mM sodium dodecyl sulphate (SDS) and 20% acetonitrile for amino acids and 60 mM Na2HPO4 (pH 8.0), 17 mM SDS and 25% acetonitrile for DOPA. Under the conditions studied, chiral separation of five amino acids including Ser, Val, Ala, Thr, Cys and a chiral drug DOPA as their diastereomeric DHAIC derivatives has been achieved by micellar electrokinetic chromatography (MEKC).  相似文献   

12.
A method for quantifying of ethinylestradiol (ETE) and levo-norgestrel (LEV) in pharmaceutical products by micellar electrokinetic chromatography (MEKC) is described. The separation was carried out at 25 degrees C and 25 kV, using a 20 mM borate buffer (pH 9.2), 15 mM sodium dodecylsulfate (SDS) in 30% acetonitrile/water (v/v). Under these conditions the analysis takes about 7 min. The method has been applied for quantifying both compounds in six different commercial contraceptives and the proposed method gave good results when compared with a reference liquid chromatographic (LC) method.  相似文献   

13.
The separation of the six pyrethrin esters in a technical pyrethrum extract (Riedel-de-Ha?n, Cresent Chemical Co. Inc. Hauppauge, NY, USA) by micellar electrokinetic chromatography (MEKC) using both sodium dodecyl sulfate (SDS) and a polymerized surfactant as pseudo-stationary phases has been investigated and optimized. Parameters such as pH, SDS and polymerized sodium N-undecyl sulfate (poly-SUS) concentration, type and concentration of background electrolyte and organic modifier, as well as the acetonitrile/water ratio in the sample were studied to optimize the resolution, efficiency, and analysis time. An optimized separation of the six pyrethrin esters was achieved in 25 min with 25 mM Tris, buffered at pH 9, containing 30 mM SDS, 25% (v/v) acetonitrile, and an equal volume ratio of acetonitrile/water sample matrix at a voltage of 25 kV. The use of 0.5% (w/v) poly-SUS enhanced resolution of the pyrethrin esters and shortened the total analysis time from 25 to 20 min, compared to the SDS mediated separation. The optimized MEKC results are compared to the HPLC separation of these esters and show an improvement in efficiency and total analysis time.  相似文献   

14.
Ligand-exchange micellar electrokinetic capillary chromatography was used for the chiral resolution of underivatized and dansyl amino acid enantiomers simultaneously. The separation was achieved by chiral copper(II)-L-valine complexes incorporated in micelles of sodium dodecyl sulfate (SDS). The enantioresolution was strongly affected by SDS and a concentration of 20 mM SDS was shown to be necessary for the separation. Other impacting factors were investigated including pH, the molar ratio of copper(II) to L-valine and the total concentration of complex. Using the proposed method, 11 different dansyl amino acids and two underivatized amino acids were separated successfully with a running electrolyte of 20 mM NH4OAc, 4 mM CuSO4, 8 mM L-valine and 20 mM SDS at pH 9.0 in less than 25 min. Experiments were also performed with other amino acid ligands in order to vary the stability and the sterical arrangement of the copper(II) complexes and the possible chiral recognition mechanism was also discussed briefly.  相似文献   

15.
A method for determining Diazepam and its associated compounds in pharmaceutical products by micellar electrokinetic chromatography (MEKC) is described. The separation was carried out at 30?°C and 25 kV, using a 25 mM borate buffer (pH 9.6) and 35 mM sodium dodecylsulfate (SDS) water solution. Under these conditions the analysis was carried out within 12 min with acceptable limits of detection and quantification. The method has been applied for quantifying Diazepam in different commercial formulations when it is the active drug and when it is employed associated with other drugs (Nortriptyline, Pyridoxine hydrochloride and Sulpiride).  相似文献   

16.
CE methods have been developed for the analysis of organic and peroxide-based explosives. These methods have been developed for deployment on portable, in-field instrumentation for rapid screening. Both classes of compounds are neutral and were separated using micellar electrokinetic chromatography (MEKC). The effects of sample composition, separation temperature, and background electrolyte composition were investigated. The optimised separation conditions (25 mM sodium tetraborate, 75 mM sodium dodecyl sulfate at 25 °C, detection at 200 nm) were applied to the separation of 25 organic explosives in 17 min, with very high efficiency (typically greater than 300,000 plates m−1) and high sensitivity (LOD typically less than 0.5 mg L−1; around 1–1.5 μM). A MEKC method was also developed for peroxide-based explosives (10 mM sodium tetraborate, 100 mM sodium dodecyl sulfate at 25 °C, detection at 200 nm). UV detection provided LODs between 5.5 and 45.0 mg L−1 (or 31.2–304 μM), which is comparable to results achieved using liquid chromatography. Importantly, no sample pre-treatment or post-column reaction was necessary and the peroxide-based explosives were not decomposed to hydrogen peroxide. Both MEKC methods have been applied to pre-blast analysis and for the detection of post-blast residues recovered from controlled, small scale detonations of organic and peroxide-based explosive devices.  相似文献   

17.
Freed AL  Lunte SM 《Electrophoresis》2000,21(10):1992-1996
This paper describes the development of analytical methodology for the separation of naphthalene-2,3-dicarboxaldehyde (NDA)-derivatized substance P (CBI-SP) and five lysine-containing metabolites by micellar electrokinetic chromatography (MEKC). The effect of surfactant composition and organic modifiers on the separation was investigated. The final separation buffer consisted of 80 mM sodium cholate in 50 mM N-tris (hydroxymethyl)methyl-2-aminoethanesulfonic acid (TES), pH 7. All six lysine-containing peptides were separated under these conditions.  相似文献   

18.
Orthogonal design has been applied to the optimization of separation and determination of dauricine and daurisoline in Rhizoma Menispermi and its herbal medicine by micellar electrokinetic capillary chromatography. Operational variables, such as the voltage, micelle concentration, buffer concentration and pH were optimized. Their different effects on peak resolution were studied by the experimental design method. Optimized separation conditions were obtained and successfully applied to the separation and determination of dauricine and daurisoline in real samples. The proposed method allows alkaloids in real samples to be determined within 15 min using a buffer system composed of 25 mM HAc, 25 mM NaAc and 2% polyoxyethylene sorbitan monolaurate (Tween-20) (pH 4.5). In addition, a radial basis function neural network with a “4-18-1” structure was developed based on the experimental results of orthogonal design and uniform design, and applied to the prediction of peak resolution of dauricine and daurisoline under the optimum separation conditions given by orthogonal design. The predicted results were in good agreement with the experimental values, indicating that radial basis function neural network may be a potential method for the selection of separation conditions in capillary electrophoresis.  相似文献   

19.
A method is described for quantitating caffeine, theobromine, theophylline, paracetamol, propyphenazone, acetylsalicylic acid, salicylic acid, and codeine phosphate in corresponding real samples of food, beverages, natural products, pharmaceuticals, and cosmetic preparations by micellar electrokinetic capillary chromatography. The separation is carried out at 25 degrees C and 25 kV, using a 20mM phosphate buffer (pH 9.0), 80mM sodium dodecyl sulfate, and 7.5% (v/v) acetonitrile. UV detection is at 210 nm. The method is shown to be specific, accurate (recoveries over the range 98.9-101.2%), linear over the tested range (correlation coefficients >/= 0.9993), and precise (relative standard deviation below 2.1%). The method is applied for the quantitative analysis of these compounds in different foods, beverages, natural products, pharmaceuticals, and cosmetic products.  相似文献   

20.
Zhou XM  Liu JW  Zhang ME  Chen SJ 《Talanta》1998,46(4):757-760
The micellar electrokinetic capillary chromatography (MECC) method is reported for the separation of heparin, and for the possibility of direct determination of free heparin in plasma. The conditions for MECC were: pH 8.5, 25 mM sodium dodecyl sulfate (SDS), 25 mM borate buffer, with a 30 cmx50 mum ID fused-silica capillary. The sample was detected with a UV-detector at 270 nm with heparin as external standard. The recovery rate was 95.6-98.7%. This method was linear in the range 80-7000 U l(-1). The within-run and between-run relative standard deviations were lower than 3.1 and 4.5%, respectively. It is suggested that this MECC method may be used to determine blood samples containing high levels of heparin.  相似文献   