首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 234 毫秒
1.
稀有多金属矿中的锂、铍、铌、钽、铷、铯6种元素经常伴生共存,铍的矿物大多难以被酸彻底溶解,铌、钽极易水解,准确测定这些元素需要多种方法,分析过程繁琐。本文建立了以电感耦合等离子体质谱(ICP-MS)法同时测定稀有多金属矿中锂、铍、铌、钽、铷、铯的方法。称取矿石样品放入高压罐中,加入氢氟酸+硫酸+硝酸的混酸,拧紧盖子后进行微波消解,在高温高压的作用下可使样品完全溶解;消解后的样品转移到聚四氟乙烯烧杯中,用电热板赶酸,以盐酸(50 %)提取样品,再加入3滴氢氟代替常规的酒石酸抑制铌、钽的水解,定容后用ICP-MS直接测定。考察了微波消解到温后的保持时间,结果表明30 min可将样品完全溶解;考察了提取液的用量,结果表明10 mL盐酸(50%)和3滴氢氟酸可将样品完全提取;优化了仪器测试条件、选择了合适的测定同位素和内标元素,各元素的质谱信号在0~20 μg/mL浓度范围呈良好的线性关系,相关系数(r)均在0.9999以上。使用微波消解法和电热板消解法分别对6个稀有多金属矿石国家一级标准物质分别进行溶解,结果表明电热板消解法铍的测定结果明显偏低,微波消解法各元素测定结果均在认定值的误差范围内。方法检出限值为3.0~10.0 μg /g;测试范围为0.001~4.3 %;相对标准偏差RSD(n=12)为0.32 ~12.5 %。质量参数满足地质矿产实验规范要求。  相似文献   

2.
铊是一种高毒性的微量元素,具有较强的富集能力,已被列为肥料的强制性检验项目。选择了水溶性肥料、复混肥料、有机肥料3种代表性的肥料样品,通过比对微波消解和电热板敞口消解前处理方式;分析电感耦合等离子体原子发射光谱(ICP-AES)法和电感耦合等离子体质谱(ICP-MS)法主要干扰来源;通过建立各自的标准工作曲线、比对方法检出限、精密度、加标回收率,探讨研究肥料产品中铊含量测定方法。研究结果表明:微波消解法和电热板敞口消解法各有优点,可以根据样品实际情况灵活选择。ICP-AES法主要干扰为光谱干扰,需要在前处理过程中除去Mn元素,而ICP-MS法主要干扰为基体效应,可以使用内标物加以校正。ICP-MS法的检出限低于ICP-AES法。由于微波消解-ICP-AES法无法除去消解液中的Mn元素带来的光谱干扰,因此不适合测定铊含量。而微波消解-ICP-MS法、电热板敞口消解-ICP-AES法和电热板敞口消解-ICP-MS法这三种方法测定结果无明显差异,测定标准化肥质控样品均在指定值范围内,加标回收率为86%-110%。实验室可以根据肥料样品的数量、组成、性质合理选择搭配前处理方式和测定方法。  相似文献   

3.
建立了微波酸溶电感耦合等离子体质谱(ICP-MS)测定土壤和沉积物中Be2+的分析方法。采用HNO_3-HCl-HF混酸体系微波消解土壤及沉积物样品,以电热板赶酸的方法对样品进行前处理。优化了仪器参数,采用在线内标法消除基体效应。方法的检出限为0.0029mg/kg。对土壤标准样品进行测定,结果都在标准值范围之内;对土壤及沉积物实际样品进行测定,相对标准偏差均小于5%,加标回收率分别在94.4%~115%和91.5%~113%范围之内。实验结果表明,建立的ICP-MS法与石墨炉原子吸收(GFAA)法对土壤的沉积物中Be~(2+)的测定无差异性。  相似文献   

4.
为提高土壤检测的重金属得率,采用了微波消解/电热板组合预处理-电感耦合等离子体质谱法(ICP-MS)测定土壤重金属含量。分析了硝酸(HNO3)、氢氟酸(HF)、高氯酸(HClO4)和盐酸(HCl)组合消解液及赶酸温度对土壤预处理影响。结果显示:在硝酸和盐酸混合消解液中,硝酸占比越高,铬(Cr)、钴(Co)、铜(Cu)、镉(Cd)得率更高;消解液体系中加入氢氟酸可使消解更加彻底,提高铬与铜的得率。最优预处理消解条件为硝酸 6ml+ 氢氟酸 2ml消解液组合进行微波消解,1ml 高氯酸于155℃电热板上赶酸。经土壤标准样品GBW07401(GSS-1)和GBW07452(GSS-23)实际应用,预处理条件优化后测试准确度和稳定性均显著提高。此外使用元素铑(Rh)作为内标物时,其方法稳定性和准确性高于内标物钪(Sc)和锗(Ge)。可为相关国家土壤重金属测定标准的修制订提供方法学参考。  相似文献   

5.
采用密闭高压消解法对样品进行消解,用电感耦合等离子体发射光谱法(ICP–AES)测定进口铜精矿中的铅、镉、砷、汞有害元素。铅、镉、砷、汞的工作曲线分别在0~10,0~1,0~4,0~0.6μg/mL范围内线性良好,线性相关系数大于0.999。各元素加标回收率均为91.0%~104.7%,相对标准偏差均小于3%(n=7)。将密闭高压消解法与电热板加热法和微波消解法进行了比对分析,结果显示,密闭高压消解–ICP–AES法适合用于铜精矿样品的消解与测定。  相似文献   

6.
探讨适用于重金属分析的土壤样品处理方法。利用原子吸收光谱法测定土壤中Cu,Mn,Ni,Pb和Zn 5种元素的含量,对电热板、微波和水浴3种消解方法进行比较,结果表明:3种样品预处理方法的检出限、准确度和精密度均满足分析检测要求。其中,电热板法样品消解较彻底,Cu和Pb的测定结果准确,但试剂、时间和人力消耗多,且为敞开式消解,高温及产生的大量酸雾危害环境与健康;微波法为密闭式消解,样品和试剂用量少,耗时短,自动化程度高,消解彻底,安全环保,Mn的测定结果准确,但成本高,不适于大批量样品分析;水浴法为半封闭式消解,简单易行,Ni和Zn的测定结果准确,但消解剂中不含氢氟酸,不适于含有大量硅酸盐样品的处理。  相似文献   

7.
建立微波消解-电感耦合等离子体质谱法测定土壤中的钒、铬、钴、镍、铜、锌、钼、镉、铅9种重金属元素。采用硝酸-氢氟酸-过氧化氢三酸体系微波消解土壤样品后,加入高氯酸于赶酸仪中对样品进行处理,定容至50 mL容量瓶中,混匀至澄清,取分液用电感耦合等离子体质谱仪对土壤中的9种重金属元素进行定量分析。探讨了称样质量、样品处理试剂、干扰效应、溶液酸度对测定结果的影响,各元素的质量浓度在0~100.0μg/L范围内与其对应的信号强度线性关系良好,相关系数为0.999 2~0.999 9,方法检出限为0.013~1.0 mg/kg。对土壤标准物质进行测定,测定值的相对标准偏差为0.82%~4.73%(n=6),测定值与标准值相吻合,相对误差为-12.1%~11.11%。样品处理过程中未使用盐酸,该法适于土壤中重金属元素的含量测定。  相似文献   

8.
样品前处理是测定土壤中金属元素的关键步骤,为保障测定结果能如实反应土壤环境状况,比较不同的前处理方法对土壤中6种金属元素的同时提取能力。论文基于电感耦合等离子体质谱技术,采用微波和石墨消解装置,探索消解过程中酸种类、加酸方式、消解装置、赶酸温度等因素对测定土壤标准品和实际样品结果的影响。实验结果表明,样品通过依次加入盐酸、硝酸、氢氟酸、高氯酸,并在160 ℃赶酸的石墨消解方式进行前处理能快速、准确地测定土壤中的Cu、Pb、Zn、Cd、Cr、Ni六种元素,其前处理时长约8.5 h,并且消解成本比微波消解更低。在优化条件下,土壤标准样品中6种金属元素的检测结果的绝对回收率为91.5%~108%,相对标准偏差为0.8%~ 5.4%,方法检出限为0.02 mg/kg ~2 mg/kg。表明方法的灵敏度高、准确度与精密度好,适用于批量土壤样品的分析。  相似文献   

9.
微波王水消解不赶酸原子荧光光谱法测定土壤中的砷   总被引:1,自引:0,他引:1  
采用微波消解土壤样品不赶酸的情况下利用原子荧光光谱法测定土壤中的砷.结果表明:微波王水消解土壤样品不赶酸情况下,砷的测定值均在国家标准物质ESS-1的推荐值范围内.砷的线性范围分别为0.0~50.0μg/L,相关系数为r=0.9995.按称取0.2 g样品,定容至50 mL,求出砷检出限为0.5 mg/kg.砷回收率为93.4%~100.9%之间,相对标准偏差(n=4)为0.39~4.56%.结果表明:微波王水消解不赶酸原子荧光光谱法测定土壤中的砷,灵敏度高,操作简便快速,结果准确可靠.  相似文献   

10.
为提高土壤多元素同时检测的效率,采用超级微波消解-电感耦合等离子体发射光谱法测定土壤中钾、钠、钙、镁、铜、铁、锰、锌、磷、硫、硼、砷、镉、铬、铅、钴、镓、锂等18种元素含量。比较了超级微波消解、常规微波消解和电热板消解的处理效果,采用超级微波消解法对样品进行前处理,并优化了消解条件。在最优条件下,各元素的检出限在0.05~20 mg/kg,加标回收率在86.2%~107.5%,RSD在0.1%~3.0%,方法准确度及精密度可以满足多元素同时测定的需求,且该方法具有简单、快速、成本低、用酸量少、重现性好等特点。  相似文献   

11.
A sample preparation method based on ultrasound-assisted pseudo-digestion of Al from Juices and soft drink samples under ultrasonic effect has been described. A Plackett-Burman experimental design was used as a multivariate strategy for the evaluation of the effects of varying several variables at once. The effects of five different variables preintensification time (without ultrasonic stirring), intensification time in ultrasonic bath (UB), temperature of UB, two acid mixtures (HNO(3)-H(2)SO(4)-H(2)O(2) and HNO(3)-H(2)O(2)), on the recovery of Al have been investigated. From these studies, certain variable showed up as significant, and they were optimized by a using 2(3)+star central composite design, which involved 16 experiments. The best conditions for pseudo-digestion were as follows: a preintensification time 10min, intensification time 20min, volume of acid mixtures 3.0ml and temperature of ultrasonic bath 80 degrees C. A conventional acid digestion on electric hot plate was used to obtain total Al for comparative purpose. Final solutions obtained from both methods, were analysed by electrothermal atomic absorption spectrometry. Analytical results for the Al by ultrasound-assisted pseudo-digestion, and conventional wet digestion methods showed a good agreement, thus indicating the possibility of using ultrasonic-assisted digestion sample preparation instead of intensive treatments inherent with the acid digestion methods on electric hot plate. The procedure proposed allowed the determination of Al with detection limit (3alpha/s) 10mugl(-1).  相似文献   

12.
A method to quantify K, Ca, Mg and Li in aluminum electrolyte by ICP-OES with wet digestion was developed. The samples were digested using aqua regia in PTFE beakers and heated by electric hot plate. The levels of four additives, namely KF, CaF2, MgF2 and LiF in aluminum electrolyte were determined simultaneously by ICP-OES. The recovery rate of this method was 93.27%–103.51%. Accuracy was also proven through the measurement of standard sample of aluminum electrolyte. The developed method was applied to relative standard deviations for three digestion replicates of ten samples were in the range from 0.51% to 8.33%.  相似文献   

13.
《Microchemical Journal》2011,97(2):412-414
A method to quantify K, Ca, Mg and Li in aluminum electrolyte by ICP-OES with wet digestion was developed. The samples were digested using aqua regia in PTFE beakers and heated by electric hot plate. The levels of four additives, namely KF, CaF2, MgF2 and LiF in aluminum electrolyte were determined simultaneously by ICP-OES. The recovery rate of this method was 93.27%–103.51%. Accuracy was also proven through the measurement of standard sample of aluminum electrolyte. The developed method was applied to relative standard deviations for three digestion replicates of ten samples were in the range from 0.51% to 8.33%.  相似文献   

14.
在微波消解仪中以氢氧化钠溶解试样,然后滴加过氧化氢,使得铸造铝ADC12中的硅完全溶解,并采用电感耦合等离子体原子发射光谱(ICP-AES)法测定,硅的质量百分数平均值为10.31%的情况下,标准偏差0.09%,相对标准偏差(RSD)为0.83%.对比了国家标准方法中加热板消解法与微波消解法对硅加标回收率的影响,加热板消解法的加标回收率低于微波消解法,微波消解法辅助前处理样品,促使样品在短时间内反应完全,实验步骤简便,结果满意.  相似文献   

15.
实验室比对盲样测定是检验实验室能力验证、实验室资质认定、机构考核的主要手段。为研究并解决测试实验室比对土壤盲样中铍、钒、镍、铜、锌、镉、铅的含量,采用微波消解电感耦合等离子体质谱(ICP-MS)法对土壤盲样进行研究,探讨了不同消解酸体系,检出限和定量限、测试模式和干扰消除、精密度和加标回收率、质控样品进行研究。结果表明:用6 mL HNO3,2 mL HCl和1 mL HF为混合酸体系,各待测元素标准曲线相关系数大于0.9995,检出限在0.001~2.985 mg.L-1,定量限在0.003~9.94 mg.L-1,采用氦气碰撞模式测试钒、镍、铜、锌、镉和铅,可以有效的降低多原子离子的干扰;采用no gas模式测试铍,可以有效的提高铍的测试灵敏度。方法精密度为0.2%~6.2%(n=6),加标回收率为92.3%~110.6%,采用土壤标准样品(GSS-4)进行全过程质控研究分析,各元素结果均在标准值参考范围内。用ICP-OES法测试土壤盲样中七种待测金属元素含量与用铑为内标的ICP-MS进行比对,测量分析结果基本一致。  相似文献   

16.
为了寻求一种更加适宜测定土壤中汞含量的测试方法,将检出限低、精密度高的冷原子吸收光谱法与便捷、高效的王水水浴消解土壤处理方式相结合,建立了王水消解-冷原子吸收光谱法测定土壤中汞。通过测定方法的线性相关性、方法检出限、准确度、精密度、加标回收率,并与原子荧光光谱法进行对比实验来评价该方法的有效性。王水消解-冷原子吸收光谱法在汞质量浓度0.0~1.0μg/L范围内线性良好,相关系数可以达到0.9999,方法检出限为0.00075 mg/kg,土壤标准样品测试的相对标准偏差为4.0%~10.7%,实际样品加标回收率分别为93%~104%。采用原子荧光光谱法进行对比测试,原子荧光光谱法的方法检出限为0.0025 mg/kg,相对标准偏差为4.8%~13.5%,加标回收率为104%~107%。结果表明,对于王水水浴消解土壤的方法不仅适用于原子荧光光谱法测定汞含量,同样可以应用于冷原子吸收光谱法中。所建立的王水消解-冷原子吸收光谱法具有更低的检出限,更优的准确度和精密度,有利于提高土壤样品测试的工作效率,值得推广。  相似文献   

17.
为了寻求一种更加适宜测定土壤中汞含量的测试方法,将检出限低、精密度高的冷原子吸收光谱法与便捷、高效的王水水浴消解土壤处理方式相结合,建立了王水消解-冷原子吸收光谱法测定土壤中汞。通过测定方法的线性相关性、方法检出限、准确度、精密度、加标回收率,并与原子荧光光谱法进行对比实验来评价该方法的有效性。王水消解-冷原子吸收光谱法在汞质量浓度0.0~1.0μg/L范围内线性良好,相关系数可以达到0.999 9,方法检出限为0.000 75mg/kg,土壤标准样品测试的相对标准偏差为4.0%~10.7%,实际样品加标回收率分别为93%~104%。采用原子荧光光谱法进行对比测试,原子荧光光谱法的方法检出限为0.002 5 mg/kg,相对标准偏差为4.8%~13.5%,加标回收率为104%~107%。结果表明,对于王水水浴消解土壤的方法不仅适用于原子荧光光谱法测定汞含量,同样可以应用于冷原子吸收光谱法中。所建立的王水消解-冷原子吸收光谱法具有更低的检出限,更优的准确度和精密度,有利于提高土壤样品测试的工作效率,值得推广。  相似文献   

18.
采用碱消解土壤溶液提取土壤溶液中的六价铬,用离子色谱(IC)进行分离,有效避免了高盐及焰色反应的干扰,电感耦合等离子体质谱(IC P-M S)法进行检测.研究了消解液使用量、消解温度、消解时间等因素,测定结果和火焰原子吸收光谱(FAAS)法进行对比.结果表明,当称样量为5.0 g,消解液40.0 mL,磷酸缓冲溶液0....  相似文献   

19.
This paper describes new approaches to digestion, accurate separation and determination of americium in soil samples by alpha spectrometry. The soil samples were obtained from surface and at a depth of 40?cm in a residential area. They were digested on a hot plate or in closed vessels heated in a microwave oven. The effect of decomposition methods on accuracy and reproducibility has been investigated. An extraction chromatography column is used to separate the americium from other actinide elements and interfering substances in the soil matrix. Prior to the determination of very low amounts of americium (100?ng?g?1), electrodeposition at a current of 800?mA and a plating time of 150?min in the pH range of 2?C3 has been applied. The typical recovery of Am from the samples is 88?% when dissolution occurs in a microwave oven. This is higher than the typical recovery of 83?% that is observed when the samples are heated on a hot plate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏