首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Lipids in skeletal muscle play a fundamental role both in normal muscle metabolism and in disease states. Skeletal muscle lipid accumulation is associated with several chronic metabolic disorders, including obesity, insulin resistance, and type 2 diabetes. However, it is poorly understood whether the lipid composition of skeletal muscle changes by contraction, due to the complexity of lipid molecular species. In this study, we used matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) to investigate changes in skeletal muscle lipid composition induced by contraction. We successfully observed the reduction of diacylglycerol and triacylglycerol, which are generally associated with muscle contraction. Interestingly, we found the accumulation of some saturated and mono-unsaturated fatty acids and poly-unsaturated fatty acids containing phosphatidylcholine in contracted muscles. Moreover, the distributions of several types of lipid were changed by contraction. Our results show that changes in the lipid amount, lipid composition, and energy metabolic activity can be evaluated in each local spot of cells and tissues at the same time using MALDI-IMS. In conclusion, MALDI-IMS is a powerful tool for studying lipid changes associated with contractions.  相似文献   

2.
The applicability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to the qualitative and quantitative analysis of most mammalian phospholipid (PL) classes was demonstrated in a crude extract of porcine lens membranes. When 2,5-dihydroxybenzoic acid (DHB) was used as the matrix, positive-ion spectra allowed the accurate quantification of phosphatidylcholines (PCs) and sphingomyelins (SMs). Other PLs such as phosphatidylethanolamines (PEs), phosphatidylethanolamine plasmalogens (PEps), phosphatidylethanolamine ethers (PEes) and phosphatidylserines (PSs), could also be detected, but their lower ionization efficiency led to negative errors in their quantification. Despite this limitation, it was possible to determine relative changes among PLs extracted from cortical and nuclear regions. Negative-ion spectra were acquired with the use of p-nitroaniline (PNA) as the matrix. Because neither PCs nor SMs produce negative ions, other PL classes can be analyzed selectively. The absolute quantification of the various PL classes detectable in negative-ion spectra was also affected by differences in ionization efficiencies. However, the trends in compositional changes between cortical and nuclear-fiber PLs were in agreement with those obtained by (31)P NMR spectroscopy. MALDI-TOFMS also offers the possibility of studying variations in the acyl-chain distribution of the various species comprising each PL class. For porcine lenses, PCs, PEs and phosphatidylinositols (PIs) exhibited the greatest depletions in going from cortical to nuclear membranes. Among their individual species, those with two or more sites of unsaturation suffered the most significant reduction.  相似文献   

3.
Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry is generally considered to be a surface analysis technique. In this report, the profiling depth of imaging mass spectrometry was examined. MALDI matrix solution was found to be able to gain access to the tissue interior and extract analyte molecules to the tissue surface. As a consequence, prazosin, a small molecule pharmaceutical compound, located as deep as 40 microm away from the surface was readily detected after matrix application. Likewise, cytochrome c, a 12 kDa protein, was also detectable from the tissue interior. Moreover, for prazosin, not only the extent of matrix effect, but also the extraction efficiency of the matrix solvent appeared to be dependent on the type of tissue. These results indicated that experimental conditions that decrease the matrix solvent evaporation during matrix application may increase analyte extraction efficiency and hence sensitivity of the analysis. Furthermore, thin sections should be used to avoid differential extraction efficiency of matrix solvent in different tissues for whole-body analysis.  相似文献   

4.
Matrix-Assisted Laser Desorption/Ionization (MALDI) Imaging Mass Spectrometry (IMS) is a molecular technology that allows simultaneous investigation of the content and spatial distribution of molecules within tissue. In this work, we examine different classes of detergents, the anionic sodium dodecyl sulfate (SDS), the nonionic detergents Triton X-100, Tween 20 and Tween 80, and the zwitterionic 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS) for use in MALDI IMS of analytes above m/z 4000. These detergents were found to be compatible with MALDI MS and did not cause signal suppression relative to non-detergent applications and did not produce interfering background signals. In general, these detergents enhanced signal acquisition within the mass range m/z 4-40 000. Adding detergents into the matrix was comparable with the separate application of detergent and matrix. Evaluation of spectra collected from organ-specific regions of a whole mouse pup section showed that different detergents perform optimally with different organs, indicating that detergent selection should be optimized on the specific tissue for maximum gain. These data show the utility of detergents towards enhancement of protein signals for on-tissue MALDI IMS analysis.  相似文献   

5.
Daniel JM  Ehala S  Friess SD  Zenobi R 《The Analyst》2004,129(7):574-578
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.  相似文献   

6.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to detect an immune complex formed between beta-lactoglobulin and polyclonal anti-beta-lactoglobulin antibody in the gas phase. The most important experimental parameters to detect such a specific antibody-antigen complex by MALDI were the use of solutions at near-neutral pH and of sinapinic acid matrix prepared by the dried-droplet method. Under such conditions, predominantly one but also two molecules of antigen protein were complexed by the antibody. Specific formation of the antibody-antigen complex was confirmed by performing competitive reactions. Addition of antibody to a 1:1 mixture of beta-lactoglobulin and one control protein resulted not only in the appearance of the expected antibody-antigen complex, but also in a strong decrease in the free beta-lactoglobulin signal, while the abundance of the control protein was not influenced.  相似文献   

7.
The detection of phospholipids (PLs) by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was demonstrated nearly a decade ago. However, its use as a conventional tool for PL analysis has been hindered by ambiguities in peak assignments caused by spectral overlaps and difficulties in the detection of some PL classes when analytes with positively charged head groups, such as sphingomyelins (SMs) and phosphatidylcholines (PCs) are present. In this work, either a strong cation-exchange resin or CsCl crystals were added directly to the PL samples to reduce spectral complexity and enhance sensitivity. The quantitative exchange resulted in virtually only protonated or Cs+ adducts. To alleviate difficulties in the detection and identification of PL classes with ionization efficiencies lower than those of SMs and PCs, improvements in the sensitivity of negative-ion mass spectra were sought. For this purpose, several neutral and basic matrices were tried. Among them, p-nitroaniline (PNA) proved to be an advantageous alternative to the use of 2,5-dihydroxybenzoic acid (DHB), the most commonly used matrix in PL analysis. Because of its lower acidity, PNA increased the relative amount of deprotonated species and improved the sensitivity of negative-ion mass spectra. It was possible to confirm peak assignments for PL classes that normally give weak signals when DHB is used. Noteworthy is the detection (in both positive and negative modes) and conclusive identification of species in natural mixtures of phosphatidylethanolamines (PEs) and PE plasmalogens (PEps). PNA allowed the identification of PEs and PEps even in mixtures containing SMs and PCs. Although some cations related to PCs and PEs overlapped in positive-ion spectra, these interferences were eliminated in the negative mode as only the deprotonated forms of PEs and PEps were detectable and those of SMs and PCs were absent owing to their neutrality.  相似文献   

8.
Metal labelling of peptides and proteins using high-affinity metal-chelating compounds has found widespread applications in the medical and bioanalytical fields. In the present study we investigated the analysis of peptides derivatized either with cysteine- or amino group-directed metal-bound DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) chelators in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The metal complexes of DOTA were shown to be stable under MALDI-MS conditions. The introduction of the metal label led in a number of cases to significantly increased signal-to-noise (S/N) values and thus improved sensitivity of the labelled peptides compared to their unlabelled counterparts, especially for multiply labelled peptides. The presence of the labels did alter the tandem mass spectrometric (MS/MS) behaviour, namely the formation of sequence specific a-, b- and y-ion series, in dependence of the position of the label within the peptide sequence. For cysteine-derivatized peptides several label-specific reporter ions and characteristic immonium ions could be identified. Amino-directed labelling led only to the formation of characteristic immonium ions in ε-amino groups of lysine, whereas N-terminal labelling in some cases led to the formation of a(1)- and b(1)-ions. The results clearly show that MALDI-MS is suitable for the analysis of metal-labelled peptides, which was also confirmed in liquid chromatography (LC)/MALDI-based identification of proteins in a model protein mixture labelled with Cys-reactive DOTA. Here, in comparison to a run with alkylated cysteines, more than 50% more cysteine-containing peptides were identified.  相似文献   

9.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has successfully been used to differentiate pseudo-enantiomeric (isotopically labelled) amino acids by using cyclodextrin as complexing host. By using different pseudo-enantiomeric mixtures (i.e. R(Dn) + S; and R + S(Dn)), it has been demonstrated that the preference of cyclodextrin for S-enantiomers is not due to the size differences caused by the hydrogen/deuterium substitution. It is postulated that this method can be extended to differentiate enantiomers (and determine enantiomeric excess) by using a pair of enantiomeric hosts, as demonstrated previously using other ionization techniques, but with much higher sensitivity.  相似文献   

10.
The automated use of a matrix-assisted laser desorption ionization (MALDI) mass spectrometer (MS) is described for image analysis of samples through implementation of new software for instrument control, data acquisition, and data analysis. The software permits automated acquisition of MS MALDI spectra to form an ordered data array and contains display features to provide images at one or more mass-to-charge ratio values. The technique can be used to scan tissue samples, blotted samples, gels, or other sample surfaces where the image analysis of that sample is required. The program achieves a time of typically 1 s per image point, permitting an analysis made up of large numbers of points with high spatial resolution up to 850 dpi. The features of the software are demonstrated in this paper with samples of printed images, where visible images can be compared to those obtained by mass spectrometry. Quantitative aspects are introduced by analyzing a series of sample spots containing different amounts of several proteins.  相似文献   

11.
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) was applied to the analysis of the spatial distribution of cellulose on a cross-section of juvenile poplar (Populus deltoids) stems. Microcrystalline cellulose (MCC) was used to optimize matrix (2,5-dihydroxybenzoic acid) application and instrument parameters for the detection of low hexose oligomers, which originated from cellulose in the solid phase. A section of poplar cellulose isolated from juvenile poplar stem which consisted primarily of glucose (~95%) and minor components such as xylose and lignin was used for the MALDI-IMS studies. The mass spectrum of poplar cellulose consisted of a series of evenly spaced signals having a difference of 162 m/z units, which was similar to that of MCC in linear and reflectron positive ion modes. MS images of cellulose compounds with sodium ion adducts were generated and illustrated the distribution of cellulose on the surface of the poplar stem.  相似文献   

12.
The use of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) for the quantitative determination of phospholipid (PL) molecular species has been problematic, due primarily to the formation of multiple signals (corresponding to the molecular ion and other adducts) for some classes of PL. For example, analysis of phosphatidylcholine (PC) yielded signals that corresponded to protonated and sodiated molecules in the MALDI spectrum. The resulting spectral overlap among various molecular species (e.g. [PC(16:0/18:2) + Na] and [PC(18:2/18:3)]) made it impossible to ascertain their relative amounts using this technique. Other spectral ambiguities existed among different structural isomers, such as PC(18:1/18:1) and PC(18:0/18:2). We determined that molecular species could be resolved by MALDI-TOFMS by first removing the polar head (e.g. phosphocholine) from the phospholipid to effect production of only the sodiated molecules of the corresponding diacylglycerols (DAGs). Analysis of the resulting spectrum allowed unequivocal determination of the molecular species profile of PC from potato tuber and soybean. Estimation of fatty acid composition based on the molecular species determined by MALDI-TOFMS analysis agreed with that from GC-FID analysis. Post-source decay (PSD) was used to resolve standard isomers of PC (e.g. 18:1/18:1 vs. 18:0/18:2). Our results indicated that PSD is a useful approach for resolving structural isomers of PL molecular species.  相似文献   

13.
This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative or positive mode allows direct and easy access to the nucleotide sequence and identification of the internucleosidic linkage. The mechanisms of the fragmentation of the solid-supported oligonucleotides induced by MALDI-TOFMS are discussed. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

14.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and laser desorption/ionization (LDI-)TOFMS have been used to characterize Suwannee River humic substances, obtained from the International Humic Substances Society (IHSS), and Armadale soil fulvic acid (ASFA). An array of MALDI matrices were tested for use with humic substances, including alpha-cyano-4-hydroxycinammic acid (CHCA), 2-(4-hydroxyphenylazo)benzoic acid (HABA), 2,5-dihydroxybenzoic acid (DHBA), sinapinic acid, dithranol and norharmane. DHBA yielded the best results, exhibiting superior ionization efficiency, low noise, broad applicability to the analytes of interest, and most importantly producing an abundance of high mass ions, the highest observed being m/z 1848. A number of sample preparation modes were investigated; the overlayer method improved sample/matrix homogeneity and hence shot-to-shot reproducibility. The choice of the matrix, mass ratio of analyte to matrix, and the sample preparation protocol, were found to be the most critical factors governing the quality of the mass spectra. Matrix suppression was greatly enhanced by ensuring good mixing of matrix and analyte in the solid phase, proper optimization of the matrix/analyte ratio, and optimizing delayed extraction to ensure complete matrix-analyte reaction in the plume before ions are moved to the flight tube. A number of common features, in particular specific ions which could not be attributed to the matrices or to contaminants, were present in the spectra of all the humic substances, regardless of origin or operational definition. Additionally, a prominent repeating pattern of peaks separated by 55, 114 and 169 Da was clearly observed in both LDI and MALDI, suggesting that the humic compounds studied here may have quasi-polymeric or oligomeric features.  相似文献   

15.
A study of the collision-induced dissociation post-source decay (PSD) spectra of free oligosaccharides is presented. These spectra, when obtained with helium as collision gas, show (1,5)X fragments containing the reducing end sugar. The presence of these fragments permits Y ions and, consequently, B and C peaks to be identified. This is a common behaviour from which it has been possible to delineate a general method for the easy assignment of the peaks in PSD spectra of underivatized neutral sugars, allowing the sequence of a real unknown to be obtained.  相似文献   

16.
The fungal spores of Penicillium expansum, P. chrysogenum, P. citrinum, P. digitatum, P. italicum, and P. pinophilum were characterized by using matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry (MALDI-TOFMS). These fungal spores are frequently found in grain and fruit. The mass spectra of these six species were directly obtained from the intact spores without any pretreatment. The results obtained indicate that 2,5-dihydroxybenzoic acid and sinapinic acid are suitable matrices for the analysis of Penicillium spores. Characteristic ions representing the different species were obtained with sufficiently high reproducibility that these ions can be employed to identify the different fungal species. On the basis of these characteristic ions obtained from these authentic Penicillium spores, the approach was applied to characterize the fungal species contaminating the surfaces of fruit. It was demonstrated that the fungal spores directly scratched from the surfaces of fruit contaminated by unknown fungi can be rapidly identified using MALDI-TOFMS analysis without any tedious pretreatment.  相似文献   

17.
A method for the detection of BPDE-d guanosine adducts using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described and illustrated. The results indicate that MALDI is capable of detecting two other DNA benzopyrene adducts, which are trace products formed during the synthesis of BPDE-d guanosine. This MALDI-TOFMS method offers the potential for the detection of DNA adducts in human tissue using very limited sample purification and preparation.  相似文献   

18.
The S-nitrosylation of proteins is involved in the trafficking of nitric oxide (NO) in intra- and extracellular milieus. To establish a mass spectrometric method for identifying this post-translational modification of proteins, a synthetic peptide and transthyretin were S-nitrosylated in vitro and analyzed by electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The intact molecular ion species of nitrosylated compounds was identified in the ESI mass spectrum without elimination of the NO group. However, the labile nature of the S-NO bond was evident when the in-source fragmentation efficiently generated [M + H - 30](+) ions. The decomposition was prominent for multiply charged transthyretin ions with high charge states under ordinary ESI conditions, indicating that the application of minimum nozzle potentials was essential for delineating the stoichiometry of nitrosylation in proteins. With MALDI, the S-NO bond cleavage occurred during the ionization process, and the subsequent reduction generated [M + H - 29](+) ions.  相似文献   

19.
A novel method for acquisition and numerical analysis of matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectral data is described. The digitized ion current transient from each consecutive laser shot is first acquired and stored independently. Subsequently, statistical correlation parameters between all stored transients are computed. We illustrate the uses of this event-by-event analysis method for studies of sample surface heterogeneity as well as for elucidating the mechanisms of ion formation in MALDI. Other potential applications of the method are also outlined.  相似文献   

20.
The trend of miniaturization in bioanalytical chemistry is shifting from technical development to practical application. In matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), progress in miniaturizing sample spots has been driven by the needs to increase sensitivity and speed, to interface with other analytical microtechnologies, and to develop miniaturized instrumentation.We review recent developments in miniaturizing sample spots for MALDI-MS. We cover both target modification and microdispensing technologies, and we emphasize the benefits with respect to sensitivity, throughput and automation.We hope that this review will encourage further method development and application of miniaturized sample spots for MALDI-MS, so as to expand applications in analytical chemistry, protein science and molecular biology.  相似文献   