共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
Sensitive determination of cinnarizine in human plasma by high performance liquid chromatography and fluorescence detection 总被引:2,自引:0,他引:2
Summary A sensitive high performance liquid chromatographic method has been developed for the determination of cinnarizine in human plasma. Cinnarizine and clocinizine (internal standard) were extracted from acidified plasma (pH 4.7) into carbon tetrachloride and the organic layer was evaporated. The products were separated on a Microspher C18 (3 m) column, using a mixture of 0.04 % triethylamine in 0.01 M ammonium dihydrogen phosphate (NH4H2PO4), pH adjusted to 4.2 with orthophosphoric acid (H3PO4), and acetonitrile (2080, v/v) as mobile phase, at a flow rate of 1 ml/min at 40°C. Fluorescence detection (ex = 245 nm, em = 310 nm) was used; the detection limit was 0.5 ng/ml under the conditions used, and the calibration curve linear in the concentration range evaluated (1–60 ng/ml). The assay has been used to measure cinnarizine concentrations in plasma after oral administration to volunteers. 相似文献
4.
5.
K Masumoto Y Tashiro K Matsumoto A Yoshida M Hirayama S Hayashi 《Journal of chromatography. A》1986,381(2):323-329
A specific and highly sensitive capillary column gas chromatographic method was developed for the simultaneous determination of codeine and chlorpheniramine in human plasma. The method involves a solvent extraction and analysis by capillary column gas chromatography on a cross-linked 50% phenylmethyl silicone fused-silica capillary column with flame thermionic detection. A 10% solution of n-butanol in toluene was used as extraction medium and pyrilamine was used as internal standard. Reproducibility, linearity of calibration curves and specificity were all satisfactory with both drugs. The plasma concentration of codeine and chlorpheniramine could be measured at levels down to 0.9 ng/ml as codeine phosphate and 0.4 ng/ml as chlorpheniramine maleate, respectively. The method was applied to plasma samples from normal volunteers, and was confirmed to be adequate for biopharmaceutical and pharmacokinetic studies. 相似文献
6.
Quantitative determination of nitroglycerin in human plasma by capillary gas chromatography with electron-capture detection 总被引:2,自引:0,他引:2
A sensitive method for the selective determination of nitroglycerin at concentrations down to 50 pg/ml in human plasma is described. After the addition to plasma of a known amount of butane-1,2,4-triol trinitrate as internal standard, both compounds are extracted into hexane. Nitroglycerin is then quantitated by capillary gas chromatography with electron-capture detection. 相似文献
7.
Kahlich R Gleiter CH Laufer S Kammerer B 《Rapid communications in mass spectrometry : RCM》2006,20(2):275-283
A method for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) quantification of piritramide, a synthetic opioid, in plasma after conventional off-line solid-phase extraction (SPE) and in urine by on-line SPE-LC/MS/MS in positive electrospray mode was developed and validated. Applicability of the on-line approach for plasma samples was also tested. Deuterated piritramide served as internal standard. For the off-line SPE plasma method mixed cation-exchange SPE cartridges and a 150 x 2 mm C18 column with isocratic elution were used. For the on-line SPE method, a Waters Oasis HLB extraction column and the same C18 analytical column in a column-switching set-up with gradient elution were utilized. All assays were linear within a range of 0.5-100 ng/mL with a limit of detection of 0.05 ng/mL. The intra- and interday coefficients of variance ranged from 1.3 to 6.1% for plasma and 0.5 to 6.4% for urine, respectively. The extraction recovery for the off-line plasma assay was between 90.7 and 100.0%. Influence of matrix effects, and freeze/thaw and long-term stability were validated for both approaches; influence of urine pH additionally for quantification in urine. 相似文献
8.
H Hattori S Yamamoto M Iwata E Takashima T Yamada O Suzuki 《Journal of chromatography. A》1992,579(2):247-252
Fourteen phenothiazine derivatives were tested for their detection by gas chromatography (GC) with surface ionization detection (SID). The sensitivity of GC-SID was highest with trimeprazine and levomepromazine, which contain aliphatic tertiary amino side chains, and lowest with thiethylperazine and thioproperazine, which contain sulphur residues. Chlorpromazine, trimeprazine and promazine showed excellent linearity between the SID response and the drug amount in the range 0.25-3.0 pmol on-column. Their detection limits were as low as ca. 5-10 pg (15-30 fmol) on-column (250-500 pg per ml of body fluid). A detailed procedure for isolation of phenothiazines from human whole blood and urine using Sep-Pak C18 cartridges, before the GC with SID, is also presented. The recoveries of the drugs (100 pmol), which were added to 1 ml of whole blood or urine, were more than 79%. The baselines remained steady as the column temperature was increased. 相似文献
9.
Analysis of amlodipine in human plasma by gas chromatography 总被引:3,自引:0,他引:3
10.
A rapid, sensitive, and reliable method for the determination of nifedipine in human plasma is described. Using a single-step solvent extraction and capillary gas chromatography combined with electron capture detection, an assay sensitivity of 2 ng/ml is achieved routinely using 0.5 ml of plasma. Intact nifedipine is quantitated and separated from its nitroso- and nitropyridine-derivatives. The suitability of the assay for pharmacokinetic studies is illustrated. 相似文献
11.
An analytical method for the determination of norethisterone acetate (NETA) in human plasma by capillary gas chromatography-mass-selective detection (GC-MS), with testosterone acetate as internal standard, was developed and validated. After addition of the internal standard, the compounds were extracted from plasma at basic pH into diethyl ether-dichloromethane (3:2 v/v), which was then evaporated to dryness. The compounds were converted into their pentafluoropropionyl derivatives which were determined by gas chromatography using a mass selective detector at m/z 486 for NETA and m/z 476 for the internal standard. Intra-day and inter-day accuracy and precision were found suitable over the range of concentrations between 0.10 to 10 ng/ml. The method was applied to clinical samples. 相似文献
12.
Sensitive determination of free and plasma protein-bound dipyridamole by high-performance liquid chromatography 总被引:1,自引:0,他引:1
For many years dipyridamole (DP) has been used in the treatment of hypertension as a vasodilator, but recently it has been recognised as an anti-platelet aggregation agent and to potentiate anti-metabolite activity. A rapid and sensitive (20 nM) procedure for the determination of free and protein-bound DP in plasma, using reversed-phase high-performance liquid chromatography on an Ultrasphere XL ODS (3 microns) column (70 mm x 4.6 mm I.D.) with ultraviolet detection (280 nm), is reported. Free and bound DP were separated using ultrafiltration. Concentrations of DP between 0.1 and 10 microM were measured in plasma with a relative standard deviation of less than 9.6%. The subsequent determination of DP levels in patients orally administered 450 mg per day showed that DP binding to plasma protein is higher than 90%. 相似文献
13.
14.
A method is described for the determination of cortisol in human plasma by high-pressure liquid chromatography. The simplified extraction procedure makes the method applicable to routine clinical assays. Partition chromatography is carried out on a Zorbax-Sil column with the eluent system dichloromethane-ethanol-water. A 78% recovery was obtained for cortisol. The detection limit is 1 mug per 100 ml in 1 ml of plasma. Cortisol values were determined in samples from a random selection of patients. 相似文献
15.
Rokitamycin and josamycin were successfully derivatized with dansylhydrazine in 20 min at 60 degrees C. Rokitamycin and josamycin levels were determined in plasma after ion-pair extraction into hexane-isoamyl alcohol with lauryl sulphate and precolumn derivatization. Resolution was obtained by liquid chromatography with fluorescence detection (352/537 nm) in 12 min. The limit of detection was 20 ng/ml macrolide starting from 1 ml of plasma, and linearity was demonstrated between 50 and 400 ng/ml. Inter-run coefficients of variation were 10.2% at 100 ng/ml and 9.1% at 300 ng/ml. The system was reliably used for pharmacokinetic studies in plasma. 相似文献
16.
Kondo K Lee XP Kumazawa T Sato K Watanabe-Suzuki K Seno H Suzuki O 《Journal of AOAC International》2001,84(1):19-23
A sensitive method was developed for determination of n-hexane and cyclohexane in human body fluids by headspace capillary gas chromatography (GC) with cryogenic oven trapping. Whole blood and urine samples containing n-hexane and cyclohexane were heated in a 7.5 mL vial at 70 degrees C for 15 min, and 5 mL of the headspace vapor was drawn into a glass syringe. All vapor was introduced through an injection port of a GC instrument in the splitless mode into an Rtx-Volatiles middle-bore capillary column at an oven temperature of -40 degrees C for trapping volatile compounds. The oven temperature was programmed to 180 degrees C for GC with flame ionization detection. These conditions gave sharp peaks for both n-hexane and cyclohexane, a good separation of each peak, and low background impurities for whole blood and urine. The extraction efficiencies of n-hexane and cyclohexane were 13.2-30.3% for whole blood and 12.7-20.7% for urine. The coefficients of within-day variation in terms of extraction efficiency of both compounds were 5.0-9.5% for whole blood and 3.8-10.8% for urine; those of day-to-day variation for the compounds were not greater than 16.6%. The regression equations for n-hexane and cyclohexane showed good linearity in the range of 5-500 ng/0.5 mL for whole blood and urine. The detection limits (signal-to-noise ratio = 3) for both compounds were 1.2 and 0.5 ng/0.5 mL for whole blood and urine, respectively. The data on n-hexane or cyclohexane in rat blood after inhalation of each compound are also presented. 相似文献
17.
A new gas chromatographic assay for methadone, utilizing a fused-silica capillary column, is presented. Extreme sensitivity was reached, compared to nitrogen-phosphorus and mass spectrometry detection, by employing a photoionization detector. Plasma concentrations of methadone as low as 1 ng/ml can easily be detected and, by further optimization, 0.1 ng/ml was reached. The minimum detectable amount of methadone reaching the detector was 70 fg. The results indicate that the photoionization detector has potential as a tool in drug monitoring. 相似文献
18.
19.
Summary A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS-MS) was developed for
the quantification of phloroglucinol in human plasma. Resorcinol was used as internal standard, with plasma samples extracted
using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase. The reconsituted samples
were injected into a C18 XTerra MS column (2.1×100 mm) with 3.5 μm particle size. The analytical column lasted for at least 500 injections. The mobile
phase was 15% acetonitrile (pH 3.0), with a flow rate at 100 μL min1. The mass spectrometer was operated in positive ion mode using electrospray ionization. Using MS-MS in multiple reaction
monitoring (MRM) mode, phloroglucinol was detected without severe interferences from the plasma matrix. Phloroglucinol produced
a parent molecule ([M+H]+) atm/z 127 and a corresponding product ion atm/z 8l. Detection of phloroglucinol in human plasma was accurate and precise, with quantification on limit at 0.5 ng mL1. The method has been successfully applied to a study of phloroglucinol in human specimens. 相似文献
20.
Sensitive quantification of pseudoephedrine in human plasma and urine by high-performance liquid chromatography 总被引:4,自引:0,他引:4
An assay for the selective quantification of pseudoephedrine in human plasma and urine was developed using high-performance liquid chromatography with UV detection at 205 nm. Analyte and internal standard were extracted from alkaline plasma or urine into a mixture of n-hexane and diethyl ether, and the organic phase was back-extracted into dilute acid. The chromatographic system comprises microparticulate cyanopropyl-silica as stationary phase and a ternary solvent mixture with ion-pair reagents as mobile phase. Using 0.25 ml plasma, the lower limit of quantification was 25 ng/ml with excellent linearity up to 1000 ng/ml. In urine, the calibration ranged from 2.5 to 100 micrograms/ml. The selectivity of the method was demonstrated for several pharmaceuticals with similar structures. The validated method was applied to a pharmacokinetic study with a single oral dose of 100 mg of pseudoephedrine in two galenic formulations. Precision and accuracy data of the assay and calculated pharmacokinetic parameters are presented. 相似文献