首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The potential of a recently developed lamp-based fluorescence detector for the analysis of underivatised proteins by capillary electrophoresis (CE) was investigated. Fluorescence detection (Flu) was achieved using optical light guides to deliver excitation light from a Xenon–Mercury lamp to the capillary detection window and to collect fluorescence emission and lead it to a photomultiplier. The performance of the detector was evaluated by monitoring the native fluorescence of the amino acid tryptophan and the proteins α-chymotrypsinogen A, carbonic anhydrase II, lysozyme and trypsinogen upon excitation at 280 nm. The test compounds were analysed using background electrolytes (BGEs) of sodium phosphate at pH 3.0 and 11.3. The results were compared to experiments of CE with UV absorbance detection. For tryptophan, a linear fluorescence response was obtained with a dynamic range of over 4 orders of magnitude, and a limit of detection (LOD) of 6.7 nM. This LOD was a factor of 200 more favourable than UV detection at 280 nm, and a factor of 20 better than detection at low-UV wavelengths. All tested proteins showed linear fluorescence responses up to 250 μg/mL. LODs were typically in the 10–20 nM range. These LODs were a factor of 25 lower than for UV detection at 280 nm, and comparable to UV detection at low-UV wavelengths. Overall, Flu yields much more stable baselines, especially with a BGE of high pH. The applicability of CE–Flu is demonstrated by the analysis of a degraded protein mixture, and of an expired formulation of the protein drug human growth hormone, indicating that protein degradation products can be selectively detected.  相似文献   

2.
Sluszny C  He Y  Yeung ES 《Electrophoresis》2005,26(21):4197-4203
A continuous-wave 280 nm light-emitting diode (LED) was used as the excitation source for native fluorescence detection of proteins in CE. The operating current and temperature of the LED were optimized in order to achieve high luminescence power. It was found that a forward current of 30 mA and a temperature of approximately 5 degrees C gave the best S/N. By using a set of two ball lenses to focus light from the LED, we achieved a spot of approximately 200 mum with a power of 0.1-0.2 mW on the detection window. Fluorescence was collected with a ball lens at 90 degrees angle through a bandpass filter onto a photomultiplier tube. In CZE an LOD of 20 nM for conalbumin was reached. In capillary gel electrophoresis all eight proteins from a commercial standard kit were detected with high S/N. For a 10 microg/mL total protein mixture, S/N was better than 3 for all proteins in solution. Further improvement in LOD should be possible on utilization of an LED with higher luminescence power.  相似文献   

3.
McWhorter S  Soper SA 《Electrophoresis》2000,21(7):1267-1280
As capillary electrophoresis continues to focus on miniaturization, either through reducing column dimensions or situating entire electrophoresis systems on planar chips, advances in detection become necessary to meet the challenges posed by these electrophoresis platforms. The challenges result from the fact that miniaturization requires smaller load volumes, demanding highly sensitive detection. In addition, many times multiple targets must be analyzed simultaneously (multiplexed applications), further complicating detection. Near-infrared (NIR) fluorescence offers an attractive alternative to visible fluorescence for critical applications in capillary electrophoresis due to the impressive limits of detection that can be generated, in part resulting from the low background levels that are observed in the NIR. Advances in instrumentation and fluorogenic labels appropriate for NIR monitoring have led to a growing number of examples of the use of NIR fluorescence in capillary electrophoresis. In this review, we will cover instrumental components used to construct ultrasensitive NIR fluorescence detectors, including light sources and photon transducers. In addition, we will discuss various types of labeling dyes appropriate for NIR fluorescence and finally, we will present several applications that have used NIR fluorescence in capillary electrophoresis, especially for DNA sequencing and fragment analysis.  相似文献   

4.
Chan KC  Muschik GM  Issaq HJ 《Electrophoresis》2000,21(10):2062-2066
Two solid-state UV lasers were applied to the laser-induced fluorescence (LIF) detection of various groups of compounds after separation by capillary electrophoresis. These lasers are thermoelectric-cooled, highly compact, and inexpensive. Such lasers provide few mW of quasi-continuous wave (CW) power which are sufficient and stable for LIF detection. Native fluorescence detection of tryptophan-containing proteins and peptides and related indoles was achieved at the nM level with the laser operating at 266 nm. Detection of fluorescamine-labeled amino acids and peptides was also possible at the nM level with the laser operating at 355 nm. Amino acids at a concentration as low as 10 ng/mL could be labeled with fluorescamine. Solid-state UV-LIF detection of the tryptic digest of cytochrome c after fluorescamine derivatization was demonstrated.  相似文献   

5.
A capillary electrophoretic method for a high-sensitivity analysis of cyanide has been developed. Cyanide was derivatized with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product of 1-cyanobenz[f]isoindole. This compound was detected with high sensitivity by fluorescence detection. The detection limit was 0.1 ng/mL, and the calibration curve was linear over the range 0.1-200 ng/mL. The precision of the migration time of within-run assays (n = 6) of 1 ng/mL cyanide standard solution was 0.14%. The precision of the peak area for the same runs was 1.0%. This method was applicable to blood analysis. Detection of the cyanide derivative by UV was also examined.  相似文献   

6.
Serotonin or 5-hydroxytryptamine (5-HT) is a major neurotransmitter in the central nervous system. In this work, a method for analyzing 5-HT in brain microdialysis samples using a commercially available capillary electrophoresis (CE) system has been developed. A pH-mediated in-capillary preconcentration of samples was performed, and after separation by capillary zone electrophoresis, native fluorescence of 5-HT was detected by a 266 nm solid-state laser. The separation conditions for the analysis of 5-HT in standard solutions and microdialysates have been optimized, and this method has been validated on both pharmacological and analytical bases. Separation of 5-HT was performed using a 80 mmol/L citrate buffer, pH 2.5, containing 20 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD) and +30 kV voltage. The detection limit was 2.5 x 10(-10) mol/L. This method allows the in vivo brain monitoring of 5-HT using a simple, accurate CE measurement in underivatized microdialysis samples.  相似文献   

7.
In this study, we developed a novel assay that simultaneously detects multiple miRNAs (microRNAs) within a single capillary by combining a tandem adenosine-tailed DNA bridge-assisted splinted ligation with denaturing capillary gel electrophoresis with laser-induced fluorescence. This proposed method not only represents a significant improvement in resolution but also allows for the detection of multiple miRNAs within a single capillary based on the length differences of specified target bridge DNA. The assay's linear range covers three orders of magnitude (1.0 nM to 1.0 pM) with a limit of detection (S/N=3) as low as 190 fM (2.5 zmol). Five miRNAs of Epstein-Barr virus (EBV) were also detected in EBV-infected nasopharyngeal carcinoma cells, while they did not appear in non-virus infected cells. Moreover, the electropherogram indicated that the screening of isomiRs (isomer of miRNA) of BART2 by CE-LIF is feasible by our proposed method. The developed electrophoresis-based method for miRNA detection is fast, amplification-free, multiplexed and cost-effective, making it potentially applicable to large-scale screening of isomiRs.  相似文献   

8.
A wall-free detection method based on liquid junction in a capillary gap was proposed for laser-induced fluorescence (LIF) of capillary electrophoresis (CE). The capillary gap of the wall-free cell was fabricated by etching a 10-mm × 50-μm I.D. fused-silica capillary to obtain a polyimide coating sleeve, decoating about 6 mm at one end of both 50 μm I.D. separation and liquid junction capillary, inserting the treated capillary ends into the coating sleeve oppositely, fixing the capillaries with a gap distance of 140 μm by epoxy glue and removing the coating sleeve by burning. The theoretical model, experimental results and wall-free cell images indicated that the gap distance and applied voltage were main influence factors on the wall-free detection. Since the wall-free cell increased the absorption light path and avoided the stray light from the capillary wall, it improved the ratio of signal to noise and limit of detection (LOD) of CE-LIF. Three flavin compounds of riboflavin (RF), flavin mononucleotide sodium (FMN) and flavin adenine dinucleotide disodium (FAD) were used to evaluate the wall-free detection method. Compared with on-column cell, the LODs of the wall-free cell were improved 15-, 6- and 9-fold for RF, FMN and FAD, respectively. The linear calibration concentrations of the flavins ranged from 0.005 to 5.0 μmol/L. The column efficiency was in the range from 1.0 × 105 to 2.5 × 105 plates. The wall-free detection of CE-LIF was applied to the analysis of the flavins in spinach and lettuce leaves.  相似文献   

9.
Measurement of intracellular regulatory proteins is of great importance in many areas of biomedical research. In this communication we describe an antibody-based capillary electrophoresis system equipped with an on-line laser-induced fluorescence detector capable of measuring intracellular proteins in cultures as low as 100 cells. The system demonstrated a high degree of precision and accuracy, being capable of detecting the fluorochrome-labeled analytes of interest at concentration of approximately 0.5 pg. We have used this instrument to study concentrations of the intracellular regulatory proteins STAT-1 and STAT-3, following stimulation of lymphocyte cultures with the inflammatory cytokine, IL-6. Using a combination of four antibodies specific for either STAT-1 or STAT-3 in both their nonphosphorylated and phosphorylated forms, we were able to demonstrate the differential expression of these proteins over time.  相似文献   

10.
A new analytical method for baclofen (4-amino-3-p-chlorophenylbutyric acid) based on capillary electrophoretic separation and laser-induced fluorescence detection has been developed. Naphthalene-2,3-dicarboxaldehyde was used for precolumn derivatization of the non-fluorescent drug. Optimal separation and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH 9.5) and a He-Cd laser (excitation at 442 nm, emission at 500 nm). Linearity (r > or = 0.99) over three orders of magnitude was generally obtained and the concentration limit of detection was in the nanomolar level. Coupled with a simple cleanup procedure, the method was successfully applied to the analysis of baclofen in human plasma. Recovery of spiked baclofen in plasma was 98%. The relative standard deviation values on peak size and migration time were 7.9% and 0.4%, respectively. The limit of detection of baclofen in plasma was 10 ng/ml.  相似文献   

11.
Indirect LIF detection was applied to the detection of four acidic diuretics separated by CZE. Semiconductor laser was employed to provide the stable excitation of 473 nm. With an optimized electrophoretic buffer system which contained 5 mM of triethylamine, 0.1 microM of fluorescein, and 5% of n-butanol, fast separation of four diuretics (ethacrynic acid, chlorthalidone, bendroflumethiazide, and bumetanide) can be performed within 3 min with the detection limits of 0.2-2 microg/mL. The impacts of buffer components including the concentrations of the electrolytes, fluorescence probe, and the organic additives were demonstrated. The method was applied for the detection of diuretics in urine. As an alternative way for the fast analysis of diuretics, this indirect detection method provided the technical support for future microchip performances, in which diuretics may be detected in the microchip by the common LIF detector without derivatization.  相似文献   

12.
For the first time, citrate-capped gold nanoparticles (citrate-AuNPs) have been used for the selective extraction of indoleamines – 5-hydroxytryptophan (5-HTP), tryptophan (Trp), tryptamine (TA), 5-hydroxytryptamine (5-HT), and 5-hydroxyindoleacetic acid (5-HIAA) – prior to their analysis by capillary electrophoresis/laser-induced native fluorescence (CE/LINF). The extinction spectra obtained for the citrate-AuNPs in the presence of indoleamines revealed that 5-HTP, 5-HT, and 5-HIAA were extracted mainly because of van der Waals interactions between the indole ring and the citrate-AuNPs (hydrophobic surface), while 5-HT and TA were extracted by electrostatic attractions between the amine group of the indoleamines and the citrate ligands adsorbed on the AuNP surface. The extracted indoleamines could be liberated from the AuNP surface by the addition of high concentrations of 2-mercaptoethanol (2-ME), which binds strongly to the AuNPs. The sensitivity of this method to indoleamines could be significantly enhanced by increasing the AuNP concentration, incubation time, and sample volume. Under optimal extraction and separation conditions, the combination of NP-based extraction and CE-LINF provided 48-, 4077-, 985-, 920-, and 4030-fold improvements in the limits of detection (signal-to-noise ratio of 3) for 5-HTP, Trp, TA, 5-HT, and 5-HIAA as compared to the analysis of five indoleamines by CE-LINF. In addition, this proposed method was successfully used for the determination of TA and 5-HT in urine.  相似文献   

13.
Immunoassay is widely employed as a highly sensitive, specific analytical method for hormones and drugs in biological samples. A technique utilizing capillary electrophoresis with laser-induced fluorescence detection was examined based on the reaction process of these immunoassays in order to develop a protocol characterized by high sensitivity and high speed. The conditions of the antigen-antibody reaction and capillary electrophoresis were variously examined using fluorescein-labeled methotrexate and the antibody of methotrexate. As a result, the immunoassay could be completed within a few minutes. Moreover, detection in the pg range could be accomplished. The sensitivity corresponded to that of radioimmunoassay. A simultaneous multi-component analysis of the immunoassay is also possible due to the high resolving power of capillary electrophoresis. In this study, the possibility of a simultaneous analysis of methotrexate and vancomycin was also investigated.  相似文献   

14.
Phycobiliproteins are derived from the photosynthetic apparatus of cyanobacteria and eukaryotic algae. They are composed of a protein backbone to which linear tetrapyrrole chromophores are covalently bound. Furthermore, they are water-soluble highly fluorescent, and relatively stable at room temperature and neutral pH. For this reason, capillary electrophoresis-laser induced fluorescence (CE-LIF) seems the idea method for determination of these important proteins. The effects of buffer additives such as sodium dodecyl sulfate (SDS)and putrescine on the separation of the three major phycobiliprotein types, namely allophycocyanin, phycocyanin, and phycoerythrin, with excitation and emission maxima at 652/660, 615/647, and 565(494)/575 nm, respectively, are considered. Detection limits for these proteins by CE-LIF are some 60-500 times better than by absorbance detection. The development of a fast and sensitive CE-LIF assay such as this is of potential significance to our understand ing of chemical and biological oceanographic processes.  相似文献   

15.
The industrial application of nitrocellulose depends on its nitrogen content. When nitrocellulose presents high nitrogen content is used in the manufacture of explosives whereas nitrocellulose with low nitrogen content is used to make a wide range of daily and non-explosive products (e.g. cigarettes, paints, lacquers). This fact makes really important to develop a method for the determination and discrimination of nitrocellulose samples. This work reports, for the first time, the qualitative determination of nitrocellulose previously derivatized with 8-aminopyrene-1,3,6-trisulfonic acid (APTS) by capillary electrophoresis (CE-LIF) with laser-induced fluorescence detection (CE-LIF). APTS-labeled nitrocellulose was determined in lowly and highly nitrated nitrocellulose samples present in collodions and smokeless gunpowders, respectively, after their pulverization in liquid nitrogen. The method described enables the visual discrimination of different nitrocelluloses on the basis of the different electrophoretic profiles obtained, and provides a useful tool to determine nitrocellulose. Additionally, the use of field-amplified sample injection (FASI) enabled enhanced sample detection, which made it possible to determine nitrocellulose contained in ∼15 μg of gunpowder.  相似文献   

16.
毛细管电泳-激光诱导荧光检测法测定抗癫痫药加巴喷丁   总被引:1,自引:0,他引:1  
蔡元丽  杨甲甲  王宇飞  白珂珂  李晖 《色谱》2010,28(12):1179-1184
建立了毛细管电泳-激光诱导荧光(CE-LIF)测定抗癫痫药加巴喷丁的方法。加巴喷丁经4-氯-7-硝基苯并-2-氧杂-1,3-二唑(NBD-Cl)衍生化后,采用10 mmol/L硼砂-10 mmol/L十二烷基硫酸钠(pH 9.75)的缓冲体系,加巴喷丁在6 min内实现高效基线分离。方法的线性范围为0.01~10 mg/L(r=0.9997),检出限为2 μg/L,定量限为10 μg/L。方法的平均回收率为100.2%~103.1%,相对标准偏差为0.15%~1.00%(n=3)。该方法灵敏、快速、准确和可靠,已用于加巴喷丁药物制剂的质量控制。  相似文献   

17.
Kuo IT  Huang YF  Chang HT 《Electrophoresis》2005,26(13):2643-2651
This paper describes the analysis of biologically active amines by capillary electrophoresis (CE) in conjunction with laser-induced native fluorescence detection. In order to simultaneously analyze amines and acids as well as to achieve high sensitivity, 10 mM formic acid solutions (pH < 4.0) containing silica nanoparticles (SiNPs) were chosen as the background electrolytes. With increasing SiNP concentration, the migration times for seven analytes decrease as a result of increase in electroosmotic flow (EOF) and decrease in their electrophoretic mobilities against EOF. A small EOF generated at pH 3.0 reveals adsorption of SiNPs on the deactivated capillary wall. The decreases in electrophoretic mobilities with increasing SiNP concentration up to 0.3x indicate the interactions between the analytes and the SiNPs. Having a great sensitivity (the limits of detection at a signal-to-noise ratio (S/N) = 3 of 0.09 nM for tryptamine (TA)), high efficiency, and excellent reproducibility (less than 2.4% of the migration times), this developed method has been applied to the analysis of urinal samples with the concentrations of 0.50 +/- 0.02 microM, 0.49 +/- 0.04 microM, and 74 +/- 2 microM for TA, 5-hydroxytryptamine, and tryptophan, respectively. The successful examples demonstrated in this study open up a possibility of using functional nanoparticles for the separation of different analytes by CE.  相似文献   

18.
Insulin administration can increase muscle glycogen by utilising hyperinsulinaemic clamps prior to sports events or during the recovery phases, and increase muscle size by its chalonic action to inhibit protein breakdown. In order to control insulin abuse in equine sports, a method to detect effectively the use of insulins in horses would be required. Besides the readily available human insulin and its synthetic analogues, structurally similar insulins from other species can also be used as doping agents. This study describes a method for the simultaneous detection of bovine, porcine and human insulins, as well as the synthetic analogues Humalog (Lilly) and Novolog (Novo Nordisk) in equine plasma. Insulins were isolated from equine plasma by immunoaffinity purification, followed by centrifugal filtration, and analysed by nano-liquid chromatography-tandem mass spectrometry (LC/MS/MS). Insulin and analogues were detected and confirmed by comparing their retention times and major product ions. All five insulins (human insulin, Humalog, Novolog, bovine insulin and porcine insulin), which are exogenous in the horse, could be detected and confirmed at 0.05ng/mL. This method was successful in confirming the presence of human insulin in plasma collected from horses up to 4h after having been administered a single low dose of recombinant human insulin (Humulin R, Eli Lilly). To our knowledge, this is the first identification of exogenous insulin from post-administration horse plasma samples.  相似文献   

19.
Sodium dodecyl sulfate capillary electrophoresis by using hydroxypropylcellulose as the sieving matrix was developed for separation of proteins. 3-(2-furoyl)quinoline-2-carboxaldehyde, a fluorogenic dye, was used as the pre-column reagent to label proteins, which allows the use of laser-induced fluorescence to improve the detection sensitivity. Five standard proteins within the molecular mass range of 14,000-97,000 were used to test this method and a calibration curve was obtained between the molecular mass of these proteins and their peak migration times. This method was also applied to the separation of proteins from HT29 human colon adenocarcinoma cell extracts, and, typically, nearly 30 protein components could be resolved in a 20-min separation. Similar separation patterns were observed for the cell extract proteins when three running buffer systems were employed, indicating that buffer composition did not have much influence on the separation based on HPC sieving.  相似文献   

20.
Su P  Zhang XX  Chang WB 《Electrophoresis》2003,24(18):3197-3201
An immunoassay for estrone (E(1)) in women's serum, based on the competitive reaction between fluorescein-labeled complete antigen and E(1) with limited amount of anti-estrone monoclonal antibody is described. A thermally reversible hydrogel, poly-N-isopropylacrylamide (pNIPA), was added to the buffer to improve the reproducibility. With a laser-induced fluorescence (LIF) detector, the capillary electrophoretic immunoassay (CEIA) can be applied to determine E(1) at a concentration lower than 19.6 pg/mL. The E(1) levels in ten normal women's serum were measured at the range of 118.6-222.0 pg/mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号