首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The development of organic porous polymer monoliths represents an alternative approach to stationary phase design. The use of these materials has helped to rekindle interest in capillary electrochromatography. Although a large number of investigations have explored different monolith recipes, polymerization conditions, and application challenges, few investigations have addressed the fundamentals of this separation mode with this type of material. This study addresses the thermodynamics of the reversed phase retention mechanism on 100% butyl acrylate and 1:3 butyl:lauryl acrylate (volume/volume ratio) porous polymer monoliths used in a capillary electrochromatography mode. Linear van't Hoff plots yield enthalpies of retention of ?3.9 to ?14.3 kJ/mol on two different, but related columns for five selected hydrophobic analytes across a thirty degree temperature range. Minimum plate heights were only moderately impacted over this temperature range.  相似文献   

2.
Phospholipid-coated fused-silica capillaries with immobilized avidin were applied in the chiral separation of D,L-tryptophan, D,L-PTH-serine, and D,L-PTH-threonine at pH 7.4 by open-tubular CEC. Liposomes prepared from 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-(Cap biotinyl), or 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-(Biotinyl) with different amounts of phosphatidylserine were assessed as phospholipid coating materials. The stability of the coating and the success of the coating procedure were evaluated in terms of the repeatability of the enantiomer migration times and the resolution of enantiomers. The coating procedure itself significantly affected the migration times and resolution of the enantiomers. Reliable chiral separations with high separation efficiencies were achieved through careful choice of the coating method.  相似文献   

3.
Polymers are important as materials for manufacturing microfluidic devices for electrodriven separations, in which Joule heating is an unavoidable phenomenon. Heating effects were investigated in polymer capillaries using a CE setup. This study is the first step toward the longer-term objective of the study of heating effects occurring in polymeric microfluidic devices. The thermal conductivity of polymers is much smaller than that of fused silica (FS), resulting in less efficient dissipation of heat in polymeric capillaries. This study used conductance measurements as a temperature probe to determine the mean electrolyte temperatures in CE capillaries of different materials. Values for mean electrolyte temperatures in capillaries made of New Generation FluoroPolymer (NGFP), poly-(methylmethacrylate) (PMMA), and poly(ether ether ketone) (PEEK) capillaries were compared with those obtained for FS capillaries. Extrapolation of plots of conductance versus power per unit length (P/L) to zero power was used to obtain conductance values free of Joule heating effects. The ratio of the measured conductance values at different power levels to the conductance at zero power was used to determine the mean temperature of the electrolyte. For each type of capillary material, it was found that the average increase in the mean temperature of the electrolyte (DeltaT(Mean)) was directly proportional to P/L and inversely proportional to the thermal conductivity (lambda) of the capillary material. At 7.5 W/m, values for DeltaT(Mean) for NGFP, PMMA, and PEEK were determined to be 36.6, 33.8, and 30.7 degrees C, respectively. Under identical conditions, DeltaT(Mean) for FS capillaries was 20.4 degrees C.  相似文献   

4.
Swelling of the polyimide coating of fused-silica capillaries in acetonitrile-containing buffers was found to be the reason for several problems in capillary electrophoresis (CE) and capillary electrochromatography (CEC). Scanning electron microscopy photographs of the ends of raw fused-silica tubing showed that the coating becomes soft and increases its volume after longer contact with such buffers. As a consequence, separation efficiency can deteriorate, the capillary ends can clog or break off. To prevent swelling of the polyimide coating, fused-silica capillaries used in CE or CEC were heated at 300 degrees C for a longer period of time which improved their long-term stability in comparison to raw fused-silica tubing.  相似文献   

5.
Efficient harvest and recovery of high-purity monoclonal antibodies was achieved using hydrophobic charge induction chromatography (HCIC). Both simple and complex feedstocks were studied, including protein-free cell culture supernatant and the clarified/concentrated milk of transgenic goats. Viral clearance studies demonstrated a 4-log reduction of MVM virus (minute virus of mice), along with substantial reduction of DNA content. Sorbent characterization studies confirmed that HCIC is based on the pH-dependent behavior of a dual-mode, ionizable ligand. Binding, based on hydrophobic interaction, was achieved under near-physiological conditions, and in the absence of lyotropic salt. Desorption was accomplished under mild conditions--pH 4.0. At this pH, both ligand and antibody carry a net positive charge, and desorption occurs on the basis of electrostatic charge repulsion. pH-based control of chromatographic function was demonstrated. Chromatography on this antibody-selective HCIC sorbent was evaluated as a cost-effective, process-compatible alternative to affinity chromatography protein A sorbents.  相似文献   

6.
A method is described for the synthesis of rigid, macroporous polymers (monoliths) to be used as stationary phases in capillary electrochromatography (CEC). The procedure reproducibly results in columns with good mechanical and chemical stability. Once the procedure was optimized, it yielded the desired CEC columns in nearly 100% of the cases. The batch-to-batch standard deviation of the migration of the electroosmotic flow (EOF) marker for nine randomly chosen columns was 5%. The polymerization is carried out inside the capillary, an aqueous phase is used as solvent. Monomers based on acrylamides with varying hydrophilicity were used to introduce the interactive moieties together with piperazine diacrylamide as cross-linker and vinylsulfonic acid as provider of the charged, EOF-producing moieties. The pore size of the monoliths was adjusted by adding varying amounts of ammonium sulfate to the reaction mixture. In this manner, the average pore size of a given monolith could be reproducibly adjusted to values ranging from 50 nm to 1.3 microm. The procedure was optimized for four particular types of monoliths, which differed in hydrophobicity. The latter was adjusted by introducing suitable co-monomers, such as alkyl chain-bearing molecules, into the monolithic structure. Attempts to systematically investigate the chromatographic behavior of the monolithic stationary phases were made, using a model mixture of aromatic compounds as sample. The standard deviations for the run-to-run reproducibility of the retention times for unretained and retained analytes were <1.5%. Flat Van Deemter curves were measured even at elevated flow-rates (2 mm/s). Plate heights between 10 and 15 microm were measured in this range. The retention order was taken as the principal indication for the chromatographic mode. The separation was found to be governed neither by pure reversed-phase nor by pure normal-phase chromatography, even on monoliths, where large amounts of C6 ligands had been introduced.  相似文献   

7.
Chiral-modified silica-based monoliths have become well-established stationary phases for both high performance liquid chromatography (HPLC) and capillary electrochromatography (CEC). The silica-based monoliths were fabricated either in situ in the capillaries for nano-HPLC and CEC or in a mould for “conventional” HPLC. The present review summarizes the chiral modification of silica monoliths and the recent development in the field of enantioselective separations by nano-HPLC and CEC.  相似文献   

8.
Yu C  Svec F  Fréchet JM 《Electrophoresis》2000,21(1):120-127
Photoinitiated free radical polymerization has been used for the preparation of porous polymer monoliths within UV transparent fused silica capillaries and quartz tubes. These formats were used as models for the preparation of the separation media within channels of microfabricated devices. A mixture of ethylene dimethacrylate, butyl methacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid was polymerized in the presence of a porogenic solvent consisting of 1-propanol, 1,4-butanediol, and water at room temperature under UV irradiation. Modification of the porogen composition enables the tailoring of pore size within the broad range from ca. 100 to 4000 nm. Scanning electron micrographs confirmed the homogeneity of the porous structure of the materials prepared, even in a quartz tube with a diameter as large as 4 mm. Separation properties of the resulting capillary columns were tested in capillary electrochromatography (CEC) mode using a mixture of thiourea and eight aromatic compounds. Plate number as high as 210 000 plates/m were found for a capillary column with optimized porous properties. The monolithic columns were also able to separate mixtures of peptides.  相似文献   

9.
Qu Q  Tang X  Wang C  Yang G  Hu X  Lu X  Liu Y  Yan C 《Journal of separation science》2006,29(13):2098-2102
Fused-silica capillarieswere packed with porous 1 microm bare silica microspheres and immobilized by potassium silicate-formamide in order to obtain columns with silica-based monolithic packing. After curing, the particle-fixed monolithic columns were octadecylated insitu with dimethyloctadecylchlorosilane. The columns were mechanically strong and permeable. No noticeable loss in efficiency was found after using a column continuously for 1 month. The performances of the particle-fixed silica monolithic columns were evaluated for CEC under RP conditions. High separation efficiency (about125 200 plates/m) was obtained by using these new types of columns.  相似文献   

10.
11.
An adamantyl (ADM)-functionalized monolithic stationary phase was newly synthesized by a single-step copolymerization of 1-adamantyl-(α-trifluoromethyl) acrylate, ethylene dimethacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid in order to prevent the peak tailing of basic solutes in capillary electrochromatography and was compared with butyl methacrylate (BMA)-based one. The ADM structure shields the negatively charged groups on the surface of monolith from basic solutes, resulting in better peak shapes than BMA-based monolithic stationary phase. As the monomers ratio decreased, the monolithic column had lower retention and higher column efficiency which was likely due to lower phase ratio and smaller globule size of monolith, respectively. The ADM-functionalized monolithic columns exhibited a good repeatability and reproducibility of column preparation with relative standard deviation values below 9% in the studied chromatographic parameters.  相似文献   

12.
The temperature variation of electroosmotic mobility corrected for the effects of Joule heating (muEOF0) was employed to investigate the variation of the zeta-potential (zeta) with temperature in fused-silica capillaries. Experimentally determined values for zeta increased at 0.39% per degrees C, a rate that is about four to five times smaller than reported previously. Experimentally determined values of zeta were directly proportional to the absolute temperature although values were also influenced slightly by changes to the dielectric constant. It was found that the effective charge density at the inner surface of the capillary was independent of temperature.  相似文献   

13.
Online preconcentration and separation of analytes using an in situ photopolymerized hexyl acrylate-based monolith stationary phase was evaluated using electrochromatography in capillary format and microchip. The band broadening occurring during the preconcentration process by frontal electrochromatography and during the desorption process by elution electrochromatography was studied. The hexyl acrylate-based monolith provides high retention for neutral analytes allowing the handling of large sample volumes and its structure allows rapid mass transfer, thus reducing the band broadening. For moderately polar analytes such as mono-chlorophenols that are slightly retained in water, it was shown that enrichment factors up to 3500 can be obtained by a hydrodynamic injection of several bed volumes for 120 min under 0.8 MPa with a decrease in efficiency of 50% and a decrease of 30% for the resolution between 2- and 3-chlorophenol. An 8 min preconcentration time allows enrichment factors above 100 for polyaromatic hydrocarbons. The interest of these monoliths when synthesized in microchip is also demonstrated. A 200-fold enrichment was easily obtained for PAHs with only 1 min as preconcentration time, without decrease in efficiency.  相似文献   

14.
In the present paper, two new methods, sol-gel and chemical bonding methods, were proposed for preparation of sulfonated fused-silica capillaries. In the sol-gel method, a fused-silica capillary was coated with the sol solution obtained by hydrolysis of 3-mercaptopropyltrimethoxysilane (MPTS) and tetramethoxysilane, and followed by age; while in the chemical bonding method, a capillary was chemically bonded directly with MPTS. Then, both the resulting capillaries were oxidized with an aqueous solution of hydrogen peroxide solution (H2O2) (30%, m/m) to obtain the sulfonated capillaries. The electroosmotic flow (EOF) for the sulfonated capillaries was found to remain almost constant within the studied pH range, and greater than that of the uncoated capillary. However, the coating efficiency of the capillary prepared by chemical bonding method was higher than that by sol-gel method, by comparing their magnitude of the EOF, the degree of disguise of the silanol and reproducibility of preparation procedure. The effects of the electrolyte's concentration and the content of methanol (MeOH) on the EOF were also studied. Especially, the study of the apparent pH (pH*) on the EOF in a water-MeOH system was reported. Finally, capillary electrophoretic separation of seven organic acids was achieved within 6.5 min under optimal condition using the chemically bonded sulfonated capillary. Moreover, separation of four alkaloids on the sulfonated capillary was compared with that on uncoated capillary in different conditions. Ion-exchange mechanism was found to play a key role for separation of these four basic analytes on the sulfonated capillary.  相似文献   

15.
Effective heat dissipation is critical for reproducible and efficient separations in electrically driven separation systems. Flow rate, retention kinetics, and analyte diffusion rates are some of the characteristics that are affected by variation in the temperature of the mobile phase inside the column. In this study, we examine the issue of Joule heating in packed capillary columns used in capillary electrochromatography (CEC). As almost all commonly used CEC packings are poor thermal conductors, it is assumed that the packing particles do not conduct heat and heat transfer is solely through the mobile phase flowing through the system. The electrical conductivity of various mobile phases was measured at different temperatures by a conductivity meter and the temperature coefficient for each mobile phase was calculated. This was followed by measurement of the electrical current at several applied voltages to calculate the conductivity of the solution within the column as a function of the applied voltage. An overall increase in the conductivity is attributed to Joule heating within the column, while a constant conductivity means good heat dissipation. A plot of conductivity versus applied voltage was used as the indicator of poor heat dissipation. Using theories that have been proposed earlier for modeling of Joule heating effects in capillary electrophoresis (CE), we estimated the temperature within CEC columns. Under mobile and stationary phase conditions typically used in CEC, heat dissipation was found to be not always efficient. Elevated temperatures within the columns in excess of 23 degrees C above ambient temperature were calculated for packed columns, and about 35 degrees C for an open column, under a given set of conditions. The results agree with recently published experimental findings with nuclear magnetic resonance (NMR) thermometry, and Raman spectroscopic measurements.  相似文献   

16.
Silica monoliths coated with functionalised latex particles have been prepared for use in monolithic ion-exchange capillary electrochromatography (IE-CEC) for the separation of inorganic anions. The ion-exchange monoliths were prepared using 70 nm quaternary ammonium, anion-exchange latex particles, which were bound electrostatically to a monolithic silica skeleton synthesised in a fused silica capillary. The resulting stationary phases were characterised in terms of their chromatographic performance and capacity. The capacity of a 50 microm diameter 25 cm latex-coated silica monolith was found to be 0.342 nanoequivalents and 80,000 theoretical plates per column were typically achieved for weakly retained anions, with lower efficiency being observed for analytes exhibiting strong ion-exchange interaction with the stationary phase. The electroosmotic flow (EOF) was reversed after the latex-coating was applied (-25.96 m2 V(-1) s(-1), relative standard deviation (RSD) 2.8%) and resulted in anions being separated in the co-EOF mode. Ion-exchange interactions between the analytes and the stationary phase were manipulated by varying the ion-exchange selectivity coefficient and the concentration of a competing ion (phosphate or perchlorate) present in the electrolyte. Large concentrations of competing ion (greater than 1M phosphate or 200 mM perchlorate) were required to completely suppress ion-exchange interactions, which highlighted the significant retention effects that could be achieved using monolithic columns compared to open tubular columns, without the problems associated with particle-packed columns. The latex-coated silica monoliths were easily produced in bulk quantities and performed reproducibly in acidic electrolytes. The high permeability and beneficial phase ratio makes these columns ideal for micro-LC and preconcentration applications.  相似文献   

17.
Monolithic stationary phases based on octadecyl acrylate for CEC using different initiating systems (UV irradiation, thermal, and chemical initiation) in the presence of lauroyl peroxide as initiator were synthesized. For each initiation mode, the influence of the porogenic solvent composition on both the morphological and electrochromatographic properties of the resulting monoliths was investigated. Under optimal conditions, excellent efficiencies for the photochemically and chemically polymerized monoliths (minimum plate heights of 6.9–10.7 and 6.5–12.6 μm, respectively) were achieved. Thermally initiated columns gave lower efficiency values, permeabilities, and longer analysis times compared to these initiating systems. The produced monolithic stationary phases were evaluated in terms of reproducibility and gave RSD values below 9.2, 10.6, and 9.8% for UV, thermally, and chemically initiated columns, respectively.  相似文献   

18.
Numerous efforts have been made to separate proteins by capillary zone electrophoresis (CZE). The most common optimization techniques are changing the pH of the running buffer, coating the capillary surface with a hydrophilic polymer, or using additives in the sample solution. Surface coatings and solution additives can reduce the adsorption of the protein onto the capillary surface, but they diminish the separation efficiency and the resolution of CZE. This paper reports the successful separation of proteins in a untreated fused-silica capillary by raising the pH of the running buffer and washing between runs with 1.0 M sodium hydroxide. Under these conditions, model proteins and proteins in human serum have been determined by CZE. It is shown that the results from CZE are compatible with those of sodium dodecyl sulphate-polyacrylamide gel electrophoresis.  相似文献   

19.
Modern rigid porous polymer monoliths were conceived as a new class of stationary phases in classical columns in the early 1990s and later extended to the capillary format. These monolithic materials are typically prepared using a simple molding process carried out within the confines of the capillary. Polymerization of a mixture comprising monomers, initiator, and porogenic solvent affords macroporous materials with large through-pores that enable applications in a rapid flow-through mode. Since all the mobile phase must flow through the monolith, convection considerably accelerates mass transport within the monolithic separation medium and improves the separations. As a result, monolithic columns perform well even at very high flow rates. Various mechanisms including thermally and UV initiated free radical polymerization as well as ring opening metathesis copolymerizations were demonstrated for the preparation of monolithic capillary columns. The versatility of these preparation techniques was demonstrated by their use with hydrophobic (styrene, divinylbenzene, butyl methacrylate, ethylene dimethacrylate), hydrophilic (2-hydroxyethyl methacrylate, methacrylamide, methylenebisacrylamide), ionizable (vinylsulfonic acid, 2-acrylamido-2-methyl-propanesulfonic acid), and tailor-made (norborn-2-ene, 1,4,4a,5,8,8a-hexahydro-1,4,5,8-exo,endo-dimethanonaphthalene) monomers. Variation of polymerization conditions enables control of the porous properties of the monolith over a broad range and mediates the hydrodynamic properties of the monolithic columns. The applications of polymer-based monolithic capillary columns are demonstrated for numerous separations in the microHPLC mode.  相似文献   

20.
Porous polymer monoliths have emerged as unique materials for many applications, including liquid-chromatographic analyses at an unrivaled speed, solid-phase extraction, and enzyme immobilization in capillary and microfluidic chip format. This article reviews the state of the art in the preparation of monoliths in narrow-bore capillaries and microfluidic chips and their miniaturization under conditions of spatial confinement. New developments in their preparation mainly using free radical polymerization techniques with a focus on morphological aspects in view of homogeneous porous materials are described. The suitability of monoliths for analysis of both large and small molecules is also discussed.  相似文献   