首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.  相似文献   

2.
Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer. Similar experiments were carried out using dual-sprayer quadrupole time-of-flight mass spectrometry (ESI-QTOFMS/MS) at a mass resolution of 10 000 with data-dependent MS/MS acquisition; i.e. beyond an intensity threshold for the [M + H](+) ions, MS/MS spectra were automatically acquired at three different collision energies. Elemental compositions were calculated for precursor and product ions and it is shown that the combined information from LC retention behavior, UV spectra, elemental compositions, and accurate mass MS/MS spectra yield a fast impression of the steroids present in the complex mixture. Using a new software tool for structure elucidation of MS/MS spectra, an additional non-steroidal additive was identified as well.  相似文献   

3.
李上富  向丽  蔡宗苇 《色谱》2017,35(1):80-85
建立了一种基于母离子扫描模式的超高效液相色谱-三重四极杆质谱检测尿液中酰基肉碱的分析方法。对酰基肉碱类化合物所共有的m/z为60、85和144的碎片离子进行选择性检测,结合化合物母离子扫描的结果及其对应的保留时间,选取一致性较好的化合物进行筛选,再利用高分辨质谱确认,最终检测到37种酰基肉碱化合物,其中有14种尚未被HMDB和LIPID MAPS数据库收录。该方法可应用于其他生物样本(如血液、组织)中酰基肉碱的定性、定量分析,可作为检测酰基肉碱化合物的新选择。  相似文献   

4.
The application of sub-2 microm porous particle liquid chromatography (LC) operated at elevated temperatures, coupled with time-of-flight mass spectrometry (MS), to the separation and identification of metabolites of ibuprofen present in human urine following oral administrations is illustrated. The LC/MS system generated a high-resolution analytical separation that, with an analysis time of 20 min, provided a peak capacity in the order of ca. 350. Using this system a total of nine glucuronides of the drug and its metabolites were detected, including a number of isomeric acyl glucuronides of ibuprofen itself, a side-chain-oxidized carboxylic acid acyl glucuronide and a number of acyl glucuronides of various hydroxylated metabolites. The identities of the metabolites were confirmed by their accurate mass values and the presence of the common fragment ions from ibuprofen.  相似文献   

5.
A lipidomics strategy, combining high resolution reversed-phase liquid chromatography (RPLC) with high resolution quadrupole time-of-flight mass spectrometry (QqTOF), is described. The method has carefully been assessed in both a qualitative and a quantitative fashion utilizing human blood plasma. The inherent low technical variability associated with the lipidomics method allows to measure 65% of the features with an intensity RSD value below 10%. Blood plasma lipid spike-in experiments demonstrate that relative concentration differences smaller than 25% can readily be revealed by means of a t-test. Utilizing an advanced identification strategy, it is shown that the detected features mainly originate from (lyso-)phospholipids, sphingolipids, mono-, di- and triacylglycerols and cholesterol esters. The high resolution offered by the up-front RPLC step further allows to discriminate various isomeric species associated with the different lipid classes. The added value of utilizing a Jetstream electrospray ionization (ESI) source over a regular ESI source in lipidomics is for the first time demonstrated. In addition, the application of ultra high performance LC (UHPLC) up to 1200 bar to extend the peak capacity or increase productivity is discussed.  相似文献   

6.
The synthetic peptide [Dmt(1)]DALDA (Dmt-D-Arg-Phe-Lys-NH(2); Dmt = 2',6'-dimethyltyrosine; 'super-DALDA') is a mu opioid-receptor agonist. On-line liquid chromatography/quadrupole time-of-flight mass spectrometry and the corresponding stable isotope-incorporated synthetic peptide internal standard were used to quantify [Dmt(1)]DALDA that had been extracted from ovine plasma samples. The [M+2H](2+) ion was used to construct the calibration curve, and the product ion was used for verification of the peptide. The detection sensitivity for the [Dmt(1)]DALDA [M+2H](2+) ion was 12.5 fmol and 50 fmol for the m/z 432.3 product ion. The concentration profile of [Dmt(1)]DALDA was determined from a set of ovine plasma samples. The molecular specificity of the peptide quantification was confirmed by tandem mass spectrometry (MS/MS).  相似文献   

7.
采用超高效液相色谱(UHPLC)-四极杆-飞行时间质谱(Q-TOF/MS)技术定性分析茶叶籽中的酚类化合物。茶叶籽样品经乙醇水溶液提取后经反相色谱分离,通过Q-TOF/MS进行化合物的鉴定。基于山茶属及相关植物化学组成的文献,建立了一个含有106种酚类化合物的数据库。对UHPLC-Q-TOF/MS采集得到的一级质谱数据进行数据库检索,然后对检索到的化合物色谱峰进行二级质谱扫描,根据得到的碎片离子推断化合物的结构。初步推断出茶叶籽提取物中的24种酚类化合物,包括13种酚酸类、4种儿茶素类和7种黄酮类化合物,并通过与标准品比对,进一步确证了这些化合物。结果表明UHPLC-Q-TOF/MS技术可以用于对茶叶籽中酚类化合物进行快速、准确、可靠的定性分析,促进新化合物的发现与鉴别。  相似文献   

8.
The structural elucidation of by-products arising from carbofuran photodegradation using a high-pressure UV lamp has been investigated by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) employing a quadrupole time-of-flight mass spectrometer. Exact mass measurements of the [M + H]+ ions of the by-products and of product ions allowed the elemental formulae and related structures of seven photodegradation by-products (resulting, respectively, from photo-Fries rearrangement, hydroxylation of the benzene ring, oxidation of the 2,3-dihydrobenzofuran ring, cleavage of the carbamate group, hydrolysis of the ether group and the newly observed radical coupling and decarboxylation processes) to be determined confidently. Accurate mass measurements of product ions allowed ambiguities to be removed concerning neutral losses having the same nominal mass, namely CO and C2H4, allowing the fragmentation patterns to be rationalized.  相似文献   

9.
As a suitable way for routine screening of pesticides and control of other organic contaminants in water, the combination of liquid chromatography triple quadrupole tandem mass spectrometry (LC–QqQ-MS/MS) and liquid chromatography–hybrid quadrupole time-of-flight mass spectrometry (LC–QTOF-MS) has been applied to the analysis of 63 surface and waste water samples after conventional solid-phase extraction (SPE). The extracts were screened for 43 pesticides or degradation products by LC–QqQ-MS/MS achieving limits of detection (LOD) ranged from 0.04 to 2 ng L−1. Of the 43 selected pesticides, 33 were detected in water samples. The ESI–QTOF MS instrument was run using two simultaneous acquisition functions with low and high collision energy (MSE approach) and acquiring the full mass spectra. A home-made database containing more than 1100 organic pollutants was used for substance identification. Around 250 of these compounds were available at the laboratory as reference standards. Five pesticides and 3 of their degradation products, different to those selected in the QqQ method, were detected by QqTOF-MS. Thirteen pharmaceuticals and two drugs of abuse were also identified in the samples. In practice, the sample preparation proved to be suitable for both techniques and for a wide variety of substances with different polarity. Mutual confirmation and evidence of co-occurrence of several other organic contaminants were the main advantages of the combination of both techniques.  相似文献   

10.
A new method based on ultra-performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry ((Q-ToF)-MS) was developed for the analysis of 32 biologically active compounds including anti-inflammatories, analgesics, lipid regulators, psychiatric drugs, anti-ulcer agents, antibiotics, beta-blockers and phytoestrogens. This new method allows chromatographic analysis in 14 min, with instrumental detection limits from 2 to 84 pg, and limits of quantification ranging from 0.1 to 15 ng/L in tap water, and from 2 to 300 ng/L in wastewater. The potential of liquid chromatography with triple quadrupole mass spectrometry (LC/QqQ-MS) was compared with that of UPLC/(Q-ToF)-MS for the analysis of biologically active compounds in water samples. LC/Q-ToF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of ToF instruments diminishes the problem of isobaric interferences and helps the analysis of trace compounds in complex samples. In this work UPLC/Q-ToF chromatograms were recorded containing full scan spectral data. The m/z values of analytes were extracted from the total ion chromatogram (TIC) and the accurate masses of the compounds were obtained. In addition, to increase the selectivity of ToF measurements a narrow accurate mass interval (20 m m/z units mass window) was used to reconstruct the chromatographic traces. However, regarding quantitative performance in terms of dynamic range and limits of detection (LODs), typical LODs achieved by QqQ instruments operating in multiple-reaction monitoring (MRM) mode ranged from 1 to 50 ng/L in wastewater, and the linear response for QqQ instruments generally covers three orders of magnitude. This is an important advantage over ToF instruments and one of the reasons why QqQ instruments are widely used in quantitative environmental analysis.  相似文献   

11.
12.
13.
14.
The stability of the UV filter benzophenone-4 (BP-4) in free chlorine-containing water was investigated, for the first time, by liquid chromatography quadrupole time-of-flight mass spectrometry (LC–QqTOF-MS). High mass accuracy and resolution capabilities of this hybrid mass spectrometer were used for the reliable assignation of empirical formulae and chemical structures of BP-4 derivatives. Time-course profiles of the parent compound and its by-products were simultaneously recorded by direct injection of sample aliquots, after quenching the excess of chlorine, in the LC–QqTOF-MS system. At neutral pHs, in excess of chlorine, BP-4 showed a limited stability fitting a pseudo-first-order degradation kinetics. A noticeable reduction in the half-lives of BP-4 was observed when increasing the sample pH between 6 and 8 units and also in presence of bromide traces. The reaction pathway of this UV filter involved a first electrophilic substitution of hydrogen per chlorine (or bromide) in the phenolic ring, followed by oxidation of the carbonyl moiety to an ester group, which induced a further electrophilic substitution in the same aromatic ring. Above reactions were also noticed when mixing a BP-4 containing personal care product with chlorinated tap water and in chlorinated swimming pool and sewage water, previously spiked with a BP-4 standard.  相似文献   

15.
For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC–QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., β-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography–quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine.  相似文献   

16.
The anti-diuretic neurohypophysial hormone Vasopressin (Vp) and its synthetic analogue Desmopressin (Dp, 1-desamino-vasopressin) have received considerable attention from doping control authorities due to their impact on physiological blood parameters. Accordingly, the illicit use of Desmopressin in elite sport is sanctioned by the World Anti-Doping Agency (WADA) and the drug is classified as masking agent. Vp and Dp are small (8-9 amino acids) peptides administered orally as well as intranasally. Within the present study a method to determine Dp and Vp in urinary doping control samples by means of liquid chromatography coupled to quadrupole high resolution time-of-flight mass spectrometry was developed. After addition of Lys-Vasopressin as internal standard and efficient sample clean up with a mixed mode solid phase extraction (weak cation exchange), the samples were directly injected into the LC-MS system. The method was validated considering the parameters specificity, linearity, recovery (80-100%), accuracy, robustness, limit of detection/quantification (20/50 pg mL(-1)), precision (inter/intra-day<10%), ion suppression and stability. The analysis of administration study urine samples collected after a single intranasal or oral application of Dp yielded in detection windows for the unchanged target analyte for up to 20 h at concentrations between 50 and 600 pg mL(-1). Endogenous Vp was detected in concentrations of approximately 20-200 pg mL(-1) in spontaneous urine samples obtained from healthy volunteers. The general requirements of the developed method provide the characteristics for an easy transfer to other anti-doping laboratories and support closing another potential gap for cheating athletes.  相似文献   

17.
Zhao C  Wu Z  Xue G  Wang J  Zhao Y  Xu Z  Lin D  Herbert G  Chang Y  Cai K  Xu G 《Journal of chromatography. A》2011,1218(23):3669-3674
Nanoflow liquid chromatography/mass spectrometry (nano-LC/MS) has attracted increasing interest in virtue of high sensitivity, low sample consumption, and minimal matrix effect. In this work a HPLC-Chip/quadrupole time-of-flight (Q-TOF) MS device with a new ultra-high capacity small molecule chip (UHC-Chip) which features a 500 nL enrichment column and a 150 mm × 75 μm analytical column, was evaluated with a drug mixture covering a wide range of polarities. Excellent chromatographic precision with 0.1-0.5% RSD for retention time and 1.7-9.0% RSD for peak area, low limit of detection, good chip-to-chip reproducibility and linearity were obtained by using this UHC-Chip. Compared with the standard HPLC-Chip with 40 nL trapping column, the UHC-Chip showed higher enrichment capability and hence gave a higher response in signal detection. Additionally, 4-30 times increase in sensitivity was obtained compared with conventional LC/MS, which indicated that UHC-Chip/MS was a valuable tool for the quantitative analysis of low level impurities and degradation products in pharmaceuticals. Moreover, satisfactory results obtained from trace drug analysis of serum samples further proved its practicality and potential for use in drug testing and development.  相似文献   

18.
An efficient method was developed for toxicological drug screening in urine by liquid chromatography coupled with electrospray ionization time-of-flight mass spectrometry. The method relies on a large target database of exact monoisotopic masses representing the elemental formulae of reference drugs and their metabolites. Mass spectral identification is based on matching measured accurate mass and isotopic pattern (SigmaFit) of a sample component with those in the database. Data post-processing software was developed for automated reporting of findings in an easily interpretable form. The mean and median of SigmaFit for true-positive findings were 0.0066 and 0.0051, respectively. The mean and median of mass error absolute values for true-positive findings were 2.51 and 2.17 ppm, respectively, corresponding to 0.65 and 0.60 mTh. For routine screening practice, a SigmaFit tolerance of 0.03 and a mass tolerance of 10 ppm were chosen. Ion abundance differences from urine extracts did not affect the accuracy of the automatically acquired SigmaFit or mass values. The results show that isotopic pattern matching by SigmaFit is a powerful means of identification in addition to accurate mass measurement.  相似文献   

19.
Abrus mollis Hance is a traditional Chinese medicine that is widely used to treat acute and chronic hepatitis, steatosis, and fibrosis. Its therapeutic qualities of it have long been acknowledged, although the active ingredients responsible for its efficacy and the mechanisms of its action are unknown. In this study, the chemical constituents absorbed into the blood from Abrus mollis Hance were assessed by using liquid chromatography-quadrupole-time-of-flight mass spectrometry and the data was analyzed with the UNIFI screening platform. The results obtained were compared to existing chromatographic-mass spectrometry information, including retention times and molecular weights as well as known reference compounds. 41 chemical constituents were found in Abrus mollis Hance, and these included 16 flavonoids, 13 triterpenoids, five organic acids, and two alkaloids. Experimentally it was found that Abrus mollis Hance had a therapeutic benefit when treating α-naphthalene isothiocyanate-induced acute liver injury in rats. In addition, 11 blood prototypical constituents, including six flavonoids, three triterpenoids, and two alkaloids, were found in serum samples following intragastric administration of Abrus mollis Hance extracts to rats. This novel study can be used for the quality control and pharmacodynamic assessment of Abrus mollis Hance in order to assess its efficacy in the therapeutic treatment of patients.  相似文献   

20.
Glutathione S-transferases (GSTs) isolated from maize were used to catalyze the conjugation of glutathione (GSH) with chloroacetanilide herbicides, producing stable conjugates that were structurally characterized using ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/QqToF-MS) and liquid chromatography/ion trap mass spectrometry (LC/IT-MS). Enzyme-mediated dechlorination of alachlor, metolachlor, and propachlor resulted during GSH conjugation as revealed by the mass spectra of the conjugates, which was confirmed by the loss of the chlorine isotopic signature and from high accurate mass measurements. Several fragmentation patterns in the mass spectra of the chloroacetanilide-GSH conjugates can be used to verify the identities of the enzyme reaction products, such as characteristic ions corresponding to the neutral loss of glutamic acid residue (129 Da) and water (18 Da) observed in the product ion spectrum. For the first time, data are presented showing detection of chloroacetanilides that are conjugated with two GSH molecules, in addition to the known single GSH conjugates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号