首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An effective multi‐residue pretreatment technique, solid‐phase extraction (SPE) combined with dispersive liquid–liquid microextraction (DLLME), was proposed for the trace analysis of 14 polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in milk samples using gas chromatography–mass spectrometry (GC‐MS). Interesting analytes in milk samples were extracted with hexane after protein precipitation. The hexane extracts were loaded on an LC‐Florisil column to isolate analytes from the milk matrix. The elutes were dried and dissolved in acetone, which was used as the disperser solvent in subsequent DLLME procedures. The effects of several important parameters on the extraction efficiency were evaluated. Under the optimized conditions, a linear relationship was obtained in the range of 0.02–10.00 μg/L (PCBs) and 0.5–100.00 μg/L (PBDEs). The LOD (S/N=3) and relative standard deviations (RSDs, n=5) for all analytes were 0.01–0.4 μg/L and 0.6–8.5%, respectively. The recoveries of the standards added to raw bovine milk samples were 74.0–131.8%, and the repeatabilities of the analysis results were 1.12–17.41%. This method has been successfully applied to estimating PCBs and PBDEs in milk samples.  相似文献   

2.
A method has been developed and validated for the concurrent extraction, clean‐up, and analysis of polybrominated diphenyl ethers (PBDEs), α‐, β‐, and γ‐hexabromocyclododecane (HBCD), and tetrabromobisphenol A (TBBPA) in human milk and serum. Milk and serum samples were extracted using accelerated solvent extraction with acetone/hexane 1:1, v/v and liquid–liquid extraction with methyl‐tert‐butyl ether/hexane 1:1, v/v, respectively. The removal of co‐extracted biogenic materials was achieved by gel permeation chromatography followed by sulfuric acid treatment. The fractionation of the PBDEs and HBCD/TBBPA was performed using a Supelco LC‐Si SPE cartridge. The detection of the PBDEs was then performed by GC–MS and that of the HBCDs and the TBBPA was performed using UPLC–MS/MS. The pretreatment procedure was optimized, and the characteristic ions and fragmentation of the analytes were studied by MS or MS/MS. A recovery test was performed using a matrix spiking test at concentrations of 0.05–10 ng/g. The recoveries ranged from 78.6–108.8% with RSDs equal to or lower than 14.04%. The LODs were 1.8–60 pg/g. The usefulness of the developed method was tested by the analysis of real human samples, and several brominated flame retardants in different samples were detected and analyzed.  相似文献   

3.
建立了微波辅助萃取-气相色谱质谱法测定生物样品中的多溴联苯醚(PBDEs)的方法,优化了萃取剂的种类、萃取剂用量、萃取时间等微波萃取条件和GC-MS仪器分析条件。正己烷-丙酮混合溶剂提取后,经实验室自制的多层硅胶柱分离纯化,用气相色谱-质谱进行测定,该方法基质加标回收率在60%~77%之间,相对标准偏差在11%~18%之间,方法的检测限为0.03~0.20ng/g,适用于生物样品中PBDEs的测定。  相似文献   

4.
王梦梦  谢琳娜  朱英  陆一夫 《色谱》2022,40(4):354-363
建立了同位素内标-气相色谱-高分辨双聚焦磁质谱(GC-HRMS)同时测定人体血清中14种多溴联苯醚(PBDEs)的方法.血清样品解冻后,取0.5 mL与13 C标记的内标物进行混合,加入甲醇沉淀样品中的蛋白质,比较了3种酸化条件下的去脂效果和回收率,结果显示硫酸去脂效果最好;使用液液萃取法提取样品中的目标物,比较了不同...  相似文献   

5.
Xiao Z  Feng J  Shi Z  Li J  Zhao Y  Wu Y 《色谱》2011,29(12):1165-1172
建立了固相萃取同时提取、净化血清中四溴双酚A(TBBPA)、α, β, γ-六溴环十二烷(HBCD)和8种多溴联苯醚(PBDEs)同系物的样本前处理方法,并结合色谱-质谱分离分析技术检测人血清样本中该类化合物的含量。试样在加入各自的同位素内标物后以甲基叔丁基醚/正己烷(1:1, v/v)混合溶剂进行萃取,再经浓硫酸去除脂肪后,以LC-Si固相萃取柱分离HBCD/TBBPA和PBDEs。采用分步检测的方式,在50 mm长BEH C18反相色谱柱上以超高效液相色谱-串联质谱(UPLC-MS/MS)的多反应监测模式(MRM)检测HBCD和TBBPA,在15 m长的毛细管柱上以气相色谱-负化学源质谱(GC-NCI/MS)的选择离子监测模式(SIM)检测PBDEs。以胎牛血清为空白基质,当HBCD、TBBPA和BDE-209的加标水平为0.5 ng/g和5 ng/g、三溴至七溴联苯醚的加标水平为0.05 ng/g和0.5 ng/g时,它们的平均加标回收率为80.3%~108.8%,相对标准偏差为1.02%~11.42%(n=5);以信噪比(S/N)为3计算,方法的检出限(LOD)为1.81~42.16 pg/g。采用该方法对实际样品进行测定,结果表明,本方法快速、准确、灵敏度高,能够满足血清中HBCD、TBBPA和PBDEs残留的同时提取及测定的要求。  相似文献   

6.
This study presents a time‐ and solvent‐saving method, pressurized liquid extraction (PLE), to extract polybrominated diphenyl ethers (PBDEs) in sediment samples. The effects of various operating parameters (i.e., extraction solution, temperature, pressure, static/dynamic extraction times) for the quantitative extraction of PBDEs by home‐made PLE were systematically investigated and optimized. The analytes were then identified and quantitated by gas chromatography‐mass spectrometry (GC‐MS) in selected ion monitoring (SIM) mode. The 16 PBDE congeners (from tri‐ to deca‐BDE) can be completely extracted by dichloromethane: n‐hexane (3/2, v/v) at 100 °C and 100 atm combined with 15 min static and then 15 min dynamic extraction steps. Recovery of PBDEs in spiked sediment samples ranged from 52 to 104% with 2‐16% RSD, except for BDE‐206. Limits of quantitation (LOQ) were established between 4 and 400 pg/g (dry weight) in 10 g of sediment sample. The extraction efficiency of the PLE was also compared with the traditional Soxhlet extraction method. The total contents of PBDEs ranged from 8.0 to 37.9 ng/g (dry weight) in various river and coastal sediment samples in Taiwan. Deca‐BDE (BDE‐209) was the major PBDE detected in these sediment samples.  相似文献   

7.
Hu Y  Li J  Zhang Z  Zhang H  Luo L  Yao S 《Analytica chimica acta》2011,708(1-2):61-68
In this work, we developed a novel graphene-assisted matrix solid-phase dispersion (GA-MSPD) method for extraction of polybrominated diphenyl ethers (PBDEs) and their methoxylated (MeO-) and hydroxylated (OH-) analogs from environmental samples. We found that grinding the solid sample with chemically converted graphene (CCG) powder yielded a tight contact and sufficient dispersion of the sample matrix due to the large surface area and flexible nanosheet morphology of CCG. The resultant blend was eluted using a two-step elution strategy: PBDEs and MeO-PBDEs were eluted firstly by hexane/dichloromethane and analyzed by GC-ECD, and then OH-PBDEs were eluted by acetone and determined by LC-ESI-MS/MS. The GA-MSPD conditions were optimized in detail. Better recoveries were obtained with GA-MSPD than with other sorbents (C18 silica, Florisil and carbon nanotubes) and other extraction techniques (Soxhlet and accelerated solvent extraction). Other advantages of GA-MSPD, including reduced consumption of sorbent and solvent, good selectivity and short extraction time, were also demonstrated. In analysis of soil samples, the method detection limits of five PBDEs, ten MeO-PBDEs and ten OH-PBDEs were in the range of 5.9-28.7, 14.3-46.6, and 5.3-212.6 pg g(-1) dry weight, respectively. The proposed method was successfully applied to the extraction of PBDEs, MeO-PBDEs and OH-PBDEs from different kinds of spiked environmental samples, including soil, tree bark and fish.  相似文献   

8.
李健  王翼飞  周显青  施致雄 《分析化学》2016,(11):1742-1747
采用索氏提取、凝胶渗透色谱和固相萃取技术作为前处理方法,建立乳制品中6种新型溴系阻燃剂、8种多溴联苯醚、四溴双酚A和α、β、γ-六溴环十二烷异构体共18种溴系阻燃剂的同时提取与净化方法,并结合气相色谱-负化学源质谱法(GC-NCI/MS)和高效液相色谱-电喷雾电离-串联质谱法(HPLC-ESI-MS/MS)进行检测。奶样经冷冻干燥后以正己烷-丙酮(1:1, V/V)索氏提取,采用凝胶渗透色谱结合酸化硅胶柱净化,随后以LC-Si固相萃取柱分离气相和液相待测物。以GC-NCI/MS测定6种新型溴系阻燃剂和8种多溴联苯醚,以HPLC-MS/MS检测四溴双酚A和六溴环十二烷异构体,内标法定量。结果表明,以空白牛奶样品为加标基质,多数待测物平均回收率为80.1%~114.7%,方法具有良好的精密度(多数待测物相对标准偏差( RSD)在0.87%~14.9%)和灵敏度(检出限在0.2~119.2 pg/g之间),可满足乳制品中多种溴系阻燃剂同时提取、净化和检测需求。  相似文献   

9.
张晓玲  王炳玲  陆晓梅  张琦  张正东 《色谱》2012,30(12):1241-1245
建立了室内灰尘样品中8种常见多溴联苯醚(PBDEs: BDE-28、BDE-47、BDE-99、BDE-100、BDE-153、BDE-154、BDE-183和BDE-209)的气相色谱-负化学电离源质谱(GC-NCI/MS)分析方法。样品经吸尘器采集、正己烷超声萃取、浓缩后,采用GC-NCI/MS测定。结果表明,方法的加标回收率为53.2%~107.6%,日内测定的相对标准偏差(RSD)为2.8%~16.5%,日间测定的RSD为6.4%~22.6%。除了BDE-209的检出限(信噪比为3)为0.15 ng/g外,其他多溴联苯醚的检出限为0.003~0.015 ng/g。该方法灵敏度高,准确度和精密度好,简便快速,溶剂消耗量少,适用于灰尘中三溴~十溴联苯醚的测定。  相似文献   

10.
A fast extraction and clean-up method for the simultaneous determination of PCBs and PBDEs has been developed. The procedure consisted of a solid-phase extraction (SPE) of the analytes on an Oasis HLB cartridge and the subsequent on-line fat elimination by directly dropping the eluate from the SPE cartridge onto a second cartridge containing layers of activated neutral silica gel and sulphuric acid modified silica gel. Detection limits using a gas chromatography coupled with an ion trap detector in the tandem mass spectrometry mode were from 0.03 to 0.3 pg/microL for PCBs and from 0.07 to 1.3 pg/microL for PBDEs. Repeatability (lower than 11%) and reproducibility (lower than 17%), expressed as relative standard deviation (RSD, n=4), were satisfactory. The feasibility of the method developed for the determination of the target compounds was evaluated by participation in several rounds of interlaboratory exercises involving human serum with a wide range of PBDE and PCB concentrations. The method has been applied to the evaluation of PBDEs and PCBs in human serum samples of up to 1 mL.  相似文献   

11.
Frank C. Calvosa 《Talanta》2010,80(3):1116-6727
The extraction of polybrominated diphenyl ethers (PBDEs) from SRM 2585 (Organic Contaminants in House Dust) was investigated using supercritical fluid R134a as an extraction solvent. Three methods of dust extraction were studied: (1) extraction of dry dust, (2) extraction of dry dust dispersed on Ottawa sand and (3) extraction of dust wet with dichloromethane. For each of the three sample preparation methods, extracts at three temperatures (110, 150, and 200 °C) above the critical temperature of R134a were performed. Eight PBDE congeners (BDE-28, -47, -99, 100, -153, -154, -183, and -209) in the SFE extracts were analyzed by liquid chromatography negative-ion atmospheric pressure photoionization tandem mass spectrometry (LC/NI-APPI/MS/MS). The optimum extraction of PBDEs from house dust using supercritical R134a is obtained when the dust is pre-wet with dichloromethane prior to extraction to swell the dust. For all sample preparation methods, higher temperatures afforded higher percent recoveries of the eight PBDE congeners. Only a combination of high-temperature (200 °C) and pre-wetting the dust with dichloromethane produced high recovery of the environmentally important, fully brominated PBDE congener, BDE-209.  相似文献   

12.
A fast sample pretreatment method was developed to determine polybrominated diphenyl ethers (PBDEs) in polymers from waste electrical and electronic equipment (WEEE). Polymers were firstly prepared into "polymer film" to facilitate a complete Soxtec extraction. Then, three extraction parameters (including hot plate temperature, boiling time, and rinsing time) were optimized based on the recovery of target in reference polymer samples. The proposed method was successfully applied to the analysis of PBDEs in standard plastic materials from WEEE and the extraction yields of PBDEs ranged from 78.9% to 91.3%. The detection limits of PBDEs were 0.05–0.10 µg/g, indicating this method can be used as a quality assurance and quality control procedure of PBDEs in the production of electrical and electronic equipment.  相似文献   

13.
The feasibility of developing a quick, easy, efficient procedure for the simultaneous determination of organochlorinated pesticides and polychlorinated biphenyls in aquatic samples using gas chromatography with electron capture detection based on solid‐phase extraction was investigated. The extraction solvent (n‐hexane/acetone, cyclohexane/ethyl acetate, n‐hexane/dichloromethane, n‐hexane) for ultrasound‐assisted solid–liquid extraction and solid‐phase extraction columns (florisil, neutral alumina, acidic alumina, aminopropyl trimethoxy silane, propyl ethylenediamine, aminopropyl trimethoxy silane/propyl ethylenediamine, graphitized carbon black and silica) for cleanup procedure were optimized. The gas chromatography with electron capture detection method was validated in terms of linearity, sensitivity, reproducibility, and recovery. Mean recoveries ranged from 75 to 115% with relative standard deviations <13%. Quantification limits were 0.20–0.40 ng/g for organochlorinated pesticides and polychlorinated biphenyls. The satisfactory data demonstrated the good reproducibility of the method with relative standard deviations lower than 13%. In comparison to other related methods, this method requires less time and solvent and allows for rapid isolation of the target analytes with high selectivity. This method therefore allows for the screening of numerous samples and can also be used for routine analyses.  相似文献   

14.
A clean-up method was developed to enable the determination of tri-decabrominated diphenyl ethers, isomer-specific hexabromocyclododecanes (HBCDs), 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenyl ethane (DBDPE), (2-ethylhexyl)tetrabromobenzoate (TBB), and bis(2-ethylhexyl)tetrabromophthalate (TBPH) in the same dust sample extract using reasonable amounts of solvents and without dividing the sample. After extraction, the sample was separated on a silica column into three fractions that were subsequently cleaned up individually. The polybrominated diphenyl ethers (PBDEs) and DBDPE were eluted in Fraction I, TBB, TBPH, and BTBPE in Fraction II, and HBCDs in Fraction III. Fractions I and II were analyzed using gas chromatography/mass spectrometry and Fraction III using liquid chromatography/mass spectrometry. The method gave good recoveries (60-120%), precise results using (13)?C-labelled internal standards and was accurate when comparing results to certified values (PBDEs in NIST SRM 2585). The method was applied to dust samples from the Stockholm (Sweden) area. All the emerging brominated flame retardants (BFRs) studied, except BTBPE, were present in all the samples in quantifiable concentrations, often higher than the PBDEs. BTBPE was quantified in only one sample. It is evident that emerging BFRs are present in Swedish homes, and these compounds should be included in the BFR analyses of indoor environments.  相似文献   

15.
《Analytica chimica acta》2004,520(1-2):237-243
In the Czech Republic no study on the levels of brominated flame retardants in human milk has been conducted, yet. In the first step analytical method for determination of PBDEs in this bioindicator matrix was implemented. Liquid–liquid extraction (LLE) (hexane, diethyl ether), followed by gel permeation chromatography was employed for isolation of PBDEs. Identification and quantification of PBDEs was carried out by GC–MS operated in negative chemical ionisation (NCI). Two mass spectrometric technologies, one employing quadrupole and the other one high resolution (HR) time-of-flight (TOF) analyzer, etc. were used in our study. Detection limits (LODs) obtained by quadrupole analyzer ranged from 0.02 to 0.05 ng g−1 lipid weight, using high resolution time-of-flight analyzer LODs were significantly lower, ranging from 0.002–0.005 ng g−1 lipid weight, what enabled detection of minor PBDE congeners.

Within this pilot study 103 breast milk samples, obtained from mothers living in Olomouc region, were examined. Ten PBDE congeners were determined. All samples examined till now contained PBDEs residues, the dominating contaminant representing this group was congener BDE 47. In most of analysed samples levels of this compound ranged from 0.2 to 2 ng g−1 of lipid weight. Three exceptionally contaminated samples, containing levels of PBDEs 5–10 times higher than other samples, were found.  相似文献   


16.
母乳中多种含卤持久性有机污染物的联合检测方法   总被引:1,自引:0,他引:1  
建立了母乳中多种含卤持久性有机污染物(POPs)的联合检测方法,目标化合物主要包括六溴环十二烷(HBCDs)、多溴联苯醚(PBDEs)、多氯联苯(PCBs)和有机氯农药(OCPs)等.样品的前处理采用液液萃取、凝胶渗透色谱(GPC)净化和固相萃取(SPE)等技术,目标化合物经气相色谱-质谱联用仪(GC-MS)、液相色谱-三重四极杆串联质谱联用仪(LC-MS/MS)和气相色谱-三重四极杆串联质谱联用仪(GC-MS/MS)等进行检测.样品通过GPC除去脂肪,然后经SPE柱进一步净化并进行多组分分离,极大程度地减小了生物样品中复杂基质的干扰,适合样品量相对较小的人体样本中多种超痕量POPs的分析.应用灵敏度高、选择性更好的GC-MS/MS对样品中的PCBs和OCPs等进行分析,进一步降低基质的干扰.方法经过小牛血清加标实验验证,稳定可靠.POPs的加标回收率分别为88.7%~98.8%(PBDEs), 88.5%~92.5%(HBCDs), 67.9%~82.3%(PCBs)和81.7%~116.1%(OCPs),方法检出限分别为0.13~1.8 pg/mL(PBDEs), 0.31~1.2 pg/mL(HBCDs), 0.22~1.4 pg/mL(PCBs)和0.20~1.5 pg/mL(OCPs).采用本方法对潍坊地区20例母乳样品进行分析,结果显示,潍坊市母乳中HBCDs, PBDEs, PCBs、HCHs和DDTs的中值浓度分别为2.86, 7.76, 8.84、140和503 ng/g 脂重,此浓度水平与国内其它地区人群相当.  相似文献   

17.
An efficient microwave-assisted extraction (MAE) method has been developed and evaluated for the quantification of eight major polybrominated diphenylethers (PBDEs) in sewage sludge. The PBDEs were extracted from wet and dry sludge in a microwave extraction unit using a hexane/acetone mixture for 35 min at a controlled temperature of 130 °C. The extract was concentrated, cleaned up on a silica gel column, and analyzed by gas chromatography/mass spectrometry (GC/MS) in the negative chemical ionization (NCI) mode. The MAE procedure exhibited higher extraction efficiency, specifically for BDE (brominated diphenylether) 209, than the conventional Soxhlet extraction. The test congeners were clearly separated under specific instrumental operating conditions, at a source temperature of 230 °C and a column length of 20 m. The present analytical method showed recovery efficiencies ranging from 80 to 110% when applied to the PBDE-free sludge spiked with eight PBDE congeners. The efficiency of the MAE method was confirmed using sludge obtained from four sewage treatment plants (STPs). The results indicate that BDE 47, 99, and 209 are the most abundant congeners present in these sewage sludges, which is consistent with previous reports.  相似文献   

18.
A novel method for the analysis of four polybrominated diphenyl ethers (PBDEs) in environmental and human serum samples based on hollow fiber-liquid phase microextraction (HF-LPME) followed by gas chromatography-inductively coupled plasma mass spectrometric (GC-ICP-MS) detection has been developed. The organic solvent in the porous hollow fiber was first dipped into the sample for extraction at a given time, and the retracted organic phase was introduced into the GC-ICP-MS for analysis. The addition of methanol has a strong effect on the HF-LPME extraction efficiency. Other significant parameters affecting the extraction efficiency of HF-LPME were also studied. HF-LPME was effective to isolate the analytes from the complex matrix. Under the optimized conditions, the detection limits of the proposed method varied from 15.2 to 40.5 ng/L. In general, the relative standard deviations (RSDs) were less than 10%. Good linearity was obtained with the correlation coefficients all better than 0.999. The proposed method is simple, quick, few microliters of organic solvent required, and is especially suitable for the analysis of the real sample with small amount available. The overall process of HF-LPME with GC-ICP-MS was applied successfully for the determination of polybrominated diphenyl ethers (PBDEs) in environmental and spiked human serum samples, and the results were satisfactory.  相似文献   

19.
鱼肉组织中多溴联苯醚的定量分析   总被引:9,自引:0,他引:9  
多溴联苯醚(PBDEs)是一类广泛用于家用电器、电子产品、塑料泡沫、家居装饰材料等行业的添加型阻燃剂[1],使用量最多的是五溴联苯醚(penta-BDE),八溴联苯醚(octa-BDE)和十溴联苯醚(deca-BDE)3种[2]。最近的研究表明[4-6],多溴联苯醚已广泛地存在于各种环境介质、生物体及人体中  相似文献   

20.
胡侠  肖光  潘炜  毛希琴  李鹏 《色谱》2010,28(6):590-595
建立了辣椒粉及辣椒油中7种罗丹明染料的高效液相色谱-串联质谱(HPLC-MS/MS)测定方法。样品经正己烷或甲醇-水(体积比为1:1)溶液提取后,经固相萃取(SPE)柱净化,采用SB-C18柱分离,以乙腈和水(含体积分数为0.1%的甲酸)为流动相进行梯度洗脱,采用正离子模式质谱检测,在多反应监测(MRM)模式下进行定性定量测定。7种罗丹明类染料在0.0005~1.0 mg/L质量浓度范围内线性关系良好,相关系数(r2)均大于0.997;方法的检出限分别为0.21~51 μg/kg(辣椒粉)和0.19~25 μg/kg(辣椒油);方法的回收率为85.0%~106.0%,日内及日间相对标准偏差均小于20%。该方法简单、灵敏度高、分析时间短,适用于辣椒粉和辣椒油中7种罗丹明染料的同时测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号