首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
J Suttnar  J E Dyr 《Electrophoresis》1989,10(10):704-708
The electrophoretic titration curves of complex mixtures of vitamin K-dependent human blood proteins and proteins of Bothrops asper venom were investigated. In both protein mixtures some curves exhibited marked distortions such as additional maxima and minima when Pharmalyte 3-10 carrier ampholytes were used for isoelectric focusing in agarose gels. The distortions result from an unspecific interactions between some carrier ampholyte constituents with particular proteins. The interacting carrier ampholyte components could be completely removed by binding to albumin and ultrafiltration through a UM-2 Amicon membrane with resultant regular titration curves. The interacting carrier ampholyte species were only partially removed by ultrafiltration through a UM-2 membrane without incubation with albumin.  相似文献   

2.
The formation of irreversible complexes between carrier ampholyte components and proteins was investigated by gel filtration of mixtures of proteins and radioactively labelled ampholytes. Experiments were performed both with purified proteins (albumin, ferritin, beta-glucuronidase) and with a complex mixture of proteins (serum); in no case was binding of ampholytes to proteins detected. Thus the results argue against the occurrence in isoelectric focusing of proteins of artifacts due to such complex formation.  相似文献   

3.
A method is described for the preparation of rehydratable agarose gels, with specific application to the direct incorporation of 9 M urea and carrier ampholytes into rehydratable agarose gels for use in isoelectric focusing. After drying the agarose gel containing an uncharged linear polyacrylamide, one gel volume of a 9 M urea-carrier ampholyte solution is absorbed directly into the gel in 60 min, eliminating equilibration or dialysis of the gel in larger volumes of the 9 M urea-carrier ampholyte solution. Proteins with a molecular mass of 970,000 Da can be separated by isoelectric focusing in these rehydratable gels. The focused proteins can then be quantitatively transferred to nitrocellulose in less than 10 min, and any immunostaining procedure can be used to probe the blotted proteins. These agarose gels are easy to make, they rehydrate rapidly and they can be used in applications other than isoelectric focusing.  相似文献   

4.
A protocol is described for monitoring the heterogeneity of end products of organic syntheses yielding amphoteric molecules containing two or more amino groups. This protocol was found to be a valuable aid in synthesis of carrier ampholytes for specific isoelectric focusing applications. This method does not depend on the ampholytes themselves to dictate the conditions under which they are analyzed. Carrier ampholytes have been found previously to be insoluble in picric acid and the insolubility property was not dependent upon the pI of individual ampholyte species. This insolubility property was exploited in the protocol. Immobilized pH gradients were used to focus the carrier ampholytes. Ampholytes were then visualized in situ by picric acid precipitation. The data shows that the protocol is useful for analyzing the results of chemical manipulations for enhancing the resolution of carrier ampholytes. A direct relationship was shown between carrier ampholyte heterogeneity as demonstrated by this protocol and the resolution of complex protein mixtures in isoelectric focusing gels. Picric acid formed visible precipitates with a variety of organic compounds which contained more than one amino group.  相似文献   

5.
Two capillary isoelectric focusing (CIEF) systems have first been optimized: one uses a bare silica capillary and 30% (v/v) of glycerol in the separation medium while the other uses a coated capillary and an aqueous background electrolyte. To perform permanent capillary coating, two neutral polymers have been compared: hydroxypropylcellulose (HPC) and polyvinylalcohol (PVA). HPC coating gave best results for electroosmotic flow (EOF) limitation on a wide pH range: as compared to a bare silica capillary, it allowed to decrease EOF by 96% at pH 7.2 after acidic and basic treatments, whereas PVA coating lead only to a 76% decrease. The glycerol CIEF system was more satisfying for the separation of model proteins classically used as pI markers. Finally, the use of "narrow pH cuts" of carrier ampholytes added to commercial ampholyte mixtures allowed increasing resolution up to a factor 2.4 at a chosen pH for the separation of pI markers and milk proteins.  相似文献   

6.
The apparent diffusion coefficients of proteins in carrier ampholyte isoelectric focusing (CA-IEF) and in immobilized pH gradients (IPGs) are strongly dependent on the amount of buffering ions present in the system. However, whereas in CA-IEF increased levels of ampholytes facilitate diffusion, in IPGs they strongly quench it. It is concluded that a protein in an IPG matrix is isoelectric but not isoionic, in the sense that it forms a salt with the surrounding ions bound to the polyacrylamide matrix. This salt formation is beneficial as it greatly increases protein solubility at the pI. It is suggested that, when performing zymograms in situ, the IPG gel should contain at least twice the standard amount of Immobiline, so as to keep sharp enzyme bands even with prolonged incubation periods.  相似文献   

7.
The non-availability of commercial carrier ampholytes in the pH range greater than 11 has contributed to difficulties in focusing and resolving highly basic proteins/peptides using capillary isoelectric focusing (cIEF). Two different approaches, involving the use of N,N,N',N'-tetramethylethylenediamine (TEMED) and ampholyte 9-11, are investigated for their effects on the extension of separation range in cIEF. The addition of TEMED into pharmalyte 3-10 not only prevents the peptides/proteins from focusing in sections of the capillary beyond the detection point, but also extends the separation range to at least isoelectric point (pI) 12. The combination of ampholyte 9-11 with pharmalyte 3-10 surprisingly provides baseline resolution between bradykinin (pI 12) and cytochrome c (pI 10.3). The sample mixture, containing bradykinin, the high-pI protein calibration kit (pI 5.2-10.3), and cytochrome c digest, is employed to demonstrate the cIEF separation of proteins and peptides over a wide pH range of 3.7-12.  相似文献   

8.
Lalwani S  Tutu E  Vigh G 《Electrophoresis》2005,26(10):2047-2055
Two approaches are described in this paper for the synthesis of isoelectric buffers that have pI values in the 1.5 < pI < 4.3 range. The first synthesis relies on the alkylation of existing aminodicarboxylic acids and recovery of the ampholyte as an inner salt. The second synthesis method forms low-pI ampholytes by reacting a secondary amine with two equivalents of an alkylester of a haloalkanecarboxylic acid, followed by hydrolysis of the intermediate in an alkaline solution and recovery of the ampholyte as an inner salt. The new ampholytes have been analytically characterized by capillary electrophoresis, high-resolution electrospray ionization-mass spectrometry, one- and two-dimensional nuclear magnetic resonance (NMR) spectroscopy, and X-ray crystallography. The isoionic solutions of the new ampholytes have high buffering capacity and conductivity, making them good pH biasers in the receiving stream in preparative-scale pH-biased isoelectric trapping separations.  相似文献   

9.
Capillary isoelectric focusing in the presence of electroosmosis with sequential injection of carrier ampholytes and sample was found to be suitable for MS detection. The separate injection of the sample and the ampholytes provides good condition to suppress and overcome the undesirable effect of the presence of ampholytes in MS. By the appropriate selection of ampholyte solutions, whose pH range not necessarily covers the pI values of the analytes, the migration of the components can be controlled, and the impact of the ampholytes on MS detection is decreased. The unique applicability of this setup is shown by testing several parameters, such as the application of volatile electrolyte solutions, the type of the ampholytes, the order and the number of the ampholyte and sample zones. Broad and narrow pH range ampholytes were applied in experiments using uncoated capillaries with different lengths for the analyses of substituted nitrophenol dyes to achieve optimal conditions for the MS detection. Although the sample components are not leaving the pH gradient, due to the decrease in the ampholyte concentration at the position of the components, and because the sample components migrate in charged state, the ionisation is more effective for MS detection.  相似文献   

10.
Fleisher HC  Vigh G 《Electrophoresis》2005,26(13):2511-2519
Diaminocarboxylic acid carrier ampholytes, such as L-histidine, 2,3-diaminopropionic acid, L-ornithine, and L-lysine, were reacted with glycerol-1,3-diglycidyl ether (GDGE) and poly(vinyl alcohol) (PVA) in the presence of sodium hydroxide to produce hydrolytically and mechanically stable hydrogels, supported on a PVA substrate, for use as buffering membranes in isoelectric trapping (IET) separations. The pH values of the DACAPVA membranes were determined with the help of small-molecule pI markers and proteins and were found to be in the 6 < pH < 8.5 range. The membranes were successfully used to isoelectrically trap small ampholytes, desalt ampholyte solutions in IET mode, and effect the binary separation of chicken egg white proteins.  相似文献   

11.
Shim J  Dutta P  Ivory CF 《Electrophoresis》2008,29(5):1026-1035
The effects of mobility corrections on carrier ampholytes are studied at various ampholyte concentrations to understand protein behavior during IEF. IEF simulations are conducted in the presence of 25 biprotic carrier ampholytes within a pH range of 6-9 after applying the Onsager-Debye-Hückel correction to the carrier ampholytes. Two model proteins with ten charge states but without ionic strength corrections are allowed to focus under an electric field of 300 V/cm in a 1 cm long channel. The IEF simulation results show that higher ionic strengths (50 - 100 mM) cause significant changes in the transient movement as well as the final focused profiles of both ampholytes and proteins. The time required for a single, well-defined peak to form increases with ionic strength when Onsager corrections are applied to the carrier ampholytes. For a particular ampholyte concentration, the space-averaged conductivity does not change during the final focusing stage, but the magnitude of space averaged conductivity is different for different ampholyte concentration. The simulation results also reveal that at steady-state ionic strength profiles remain flat throughout the channel except at the locations of proteins where a significant change in ampholyte concentration is obtained.  相似文献   

12.
Isoelectric focusing plays a critical role in the analysis of complex protein samples. Conventionally, isoelectric focusing is implemented with carrier ampholytes in capillary or immobilized pH gradient gel. In this study, we successfully exhibited a carrier ampholyte‐free isoelectric focusing on paper‐based analytical device. Proof of the concept was visually demonstrated with color model proteins. Experimental results showed that not only a pH gradient was well established along the open paper fluidic channel as confirmed by pH indicator strip, the pH gradient range could also be tuned by the catholyte or anolyte. Furthermore, the isoelectric focusing fractions from the paper channel can be directly cut and recovered into solutions for post analysis with sodium dodecyl sulfate‐polyacrylamide gel electrophoresis and matrix‐assisted laser desorption/ionization‐time‐of‐flight mass spectrometry. This paper‐based isoelectric focusing method is fast, cheap, simple and easy to operate, and could potentially be used as a cost‐effective protein sample clean‐up method for target protein analysis with mass spectrometry.  相似文献   

13.
The impact of initial sample distribution on separation and focusing of analytes in a pH 3–11 gradient formed by 101 biprotic carrier ampholytes under concomitant electroosmotic displacement was studied by dynamic high-resolution computer simulation. Data obtained with application of the analytes mixed with the carrier ampholytes (as is customarily done), as a short zone within the initial carrier ampholyte zone, sandwiched between zones of carrier ampholytes, or introduced before or after the initial carrier ampholyte zone were compared. With sampling as a short zone within or adjacent to the carrier ampholytes, separation and focusing of analytes is shown to proceed as a cationic, anionic, or mixed process and separation of the analytes is predicted to be much faster than the separation of the carrier components. Thus, after the initial separation, analytes continue to separate and eventually reach their focusing locations. This is different to the double-peak approach to equilibrium that takes place when analytes and carrier ampholytes are applied as a homogenous mixture. Simulation data reveal that sample application between two zones of carrier ampholytes results in the formation of a pH gradient disturbance as the concentration of the carrier ampholytes within the fluid element initially occupied by the sample will be lower compared to the other parts of the gradient. As a consequence thereof, the properties of this region are sample matrix dependent, the pH gradient is flatter, and the region is likely to represent a conductance gap (hot spot). Simulation data suggest that sample placed at the anodic side or at the anodic end of the initial carrier ampholyte zone are the favorable configurations for capillary isoelectric focusing with electroosmotic zone mobilization.  相似文献   

14.
Free‐flow isoelectric focusing (FFIEF) has the merits of mild separation conditions, high recovery and resolution, but suffers from the issues of ampholytes interference and high cost due to expensive carrier ampholytes. In this paper, a home‐made carrier ampholyte‐free FFIEF system was constructed via orientated migration of H+ and OH? provided by electrode solutions. When applying an electric field, a linear pH gradient from pH 4 to 9 (R2 = 0.994) was automatically formed by the electromigration of protons and hydroxyl ions in the separation chamber. The carrier ampholyte‐free FFIEF system not only avoids interference of ampholyte to detection but also guarantees high separation resolution by establishing stable pH gradient. The separation selectivity was conveniently adjusted by controlling operating voltage and optimizing the composition, concentration and flow rate of the carrier buffer. The constructed system was applied to separation of proteins in egg white, followed by MADLI‐TOF‐MS identification. Three major proteins, ovomucoid, ovalbumin and ovotransferrin, were successfully separated according to their pI values with 15 mmol/L Tris‐acetic acid (pH = 6.5) as carrier buffer at a flow rate of 12.9 mL/min.  相似文献   

15.
North RY  Vigh G 《Electrophoresis》2008,29(5):1077-1081
The operational pH value of a buffering membrane used in an isoelectric trapping separation is determined by installing the membrane as the separation membrane into a multicompartmental electrolyzer operated in the two-separation compartment configuration. A 3相似文献   

16.
Abstract

Sephacryl is a gel filtration medium composed of allyl dextran and N,N'-methylene bisacrylamide. Sephacryl S-200 SF has a fractionation range similar to that of Sephadex G-150. Sephacryl S-300 SF has a fractionation range more similar to Sephadex G-200 or Sepharose 6B, with an exclusion limit for globular proteins of about 106 daltons. In typical applications, excellent resolution of protein mixtures was obtained at flow rates up to 30 cm/hr. Good correlation was established between elution volumes of proteins and their molecular weights. The gels contain few ionic groups, as determined by titration. Studies using Sephacryl S-200 at different pH values indicate that, above pH 3, protein does not interact with Sephacryl S-200 at moderate ionic strengths. However, below pH 3, protein binds strongly to the gel through hydrophobic interactions and/or hydrogen bonding. Most separations using Sephadex G-150 or Sephadex G-200 could be duplicated using Sephacryl S-200 or S-300 at much higher flow rates.  相似文献   

17.
A simple method for fractionating synthetic carrier ampholytes is reported, based on the principle of continuous-flow isoelectric focusing in gel-stabilized layers. An 8% ampholyte solution, encompassing the pH range 3-9.5, is separated into 12 fractions in a chamber filled with Sephadex G-100 by a continuous-flow technique. We are thus able to obtain ampholytes of narrow pH range, encompassing approximately 2 pH units, whose resolving power is comparable with that obtained with commercial Ampholine covering similar pH ranges.  相似文献   

18.
Six amino acids with pIs that ranged from 3.2 to 9.7 were used as ampholytes to establish a pH gradient in capillary isoelectric focusing. This amino acid-based capillary isoelectric focusing (cIEF) was coupled with ESI-MS/MS using an electrokinetically pumped sheath-flow interface for peptide analysis. Amino acid-based isoelectric focusing generates a two-order of magnitude lower background signal than commercial ampholytes in the important m/z range of 300–1800. Good focusing was achieved for insulin receptor, which produced ∼10 s peak width. For 0.1 mg mL−1 bovine serum albumin (BSA) digests, 24 ± 1 peptides (sequence coverage 47 ± 4%) were identified in triplicate analysis. As expected, the BSA peptides were separated according to their pI. The concentration detection limit for the BSA digests is 7 nM and the mass detection limit is 7 fmole. A solution of six bovine protein tryptic digests spanning 5 orders of magnitude in concentration was analyzed by amino acid based cIEF-ESI-MS/MS. Five proteins with a concentration range spanning 4 orders of magnitude were identified in triplicate runs. Using amino acid based cIEF-ESI-MS/MS, 112 protein groups and 303 unique peptides were identified in triplicate runs of a RAW 264.7 cell homogenate protein digest. In comparison with ampholyte based cIEF-ESI-MS/MS, amino acid based cIEF-ESI-MS/MS produces higher resolution of five acidic peptides, much cleaner mass spectra, and higher protein spectral counts.  相似文献   

19.
An online method involving transient electrokinetic dosing and ITP with neutralization reaction boundary (NRB) and/or carrier ampholyte-free isoelectric focusing (CAF IEF) was developed for the preconcentration, preseparation, and analytical determination of glyphosate in aqueous samples containing low concentrations of the analyte of interest. Various parameters were investigated in the framework of an optimization study with the aim of achieving the maximum concentration limit of detection (cLOD) decrease in minimum time. The proposed method used CAF IEF and/or ITP with NRB. The sample was dosed to the column on the stationary reaction boundary (CAF IEF) and/or moving reaction boundary (ITP with NRB), whereat a sharp pH step exists. Here, charge reversal was due to the ampholytes, and/or acid accumulation occurred because of charge loss. Similarly, the accumulated sample was mobilized with TE and analyzed using classical ITP in the second analytical column. Glyphosate (GLY), the analyte of interest, was chosen as a model substance for ITP with NRB and preconcentration as well as focusing preconcentration and CAF IEF using the asymmetric purpose-built NRB. On one side of the asymmetric boundary was the zone of acidic pH; while the opposite side comprised a neutral/basic non-conductive zone of the ampholyte—in this case, GLY. Such an arrangement enables the use of a lower pH on the acidic side, which allows the focusing of strongly acidic ampholytes and the accumulation of weak acids. The electrolyte composition and the dosing time were optimized, and a 14-fold accumulation was achieved in 25 min compared to that by classical ITP and a 180-fold accumulation was achieved through CAF IEF and preconcentration with a glyphosate sample. Both methods are simple and can be conducted using all commercial ITP systems.  相似文献   

20.
The protonation of an aqueous solution of two ampholytes AH and BH next to a gel buffered by immobilized acid moieties IH has been studied by finite element simulation in an iterative scheme. A ten species model has been formulated, taking into account transient diffusion and equilibrium kinetics of the two amphoteric species AH and BH, of water and of the immobilized species IH. This model has been developed to illustrate the pH evolution between an ampholyte solution and an Immobiline gel, and to study the influence of the Immobiline concentration on protons and ampholyte distributions. It has been demonstrated that a minimum initial Immobiline concentration of 10(-2) M is necessary to maintain the pH in the gel in contact with a closed chamber, when the difference between the isoelectric points of AH and BH is 4 and when the initial concentration of the ampholytes in solution is in the micromolar range. This approach provides a first theoretical framework for the recently developed Off-Gel trade mark electrophoresis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号