首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
To support the pharmacokinetic and bioavailability study of a once-daily fexofenadine/pseudoephedrine combination, a high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (HPLC/ESI-MS/MS) method for the simultaneous quantification of fexofenadine and pseudoephedrine was developed and validated with 500 microL human plasma using mosapride as an internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 502/466 for fexofenadine, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited linear dynamic ranges of 1-500 ng/mL and 2-1000 ng/mL for fexofenadine and pseudoephedrine, respectively, in human plasma. The lower limits of quantification were 1 and 2 ng/mL with a relative standard deviation of less than 10% for fexofenadine and pseudoephedrine, respectively. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time was 2 min and more than 400 human plasma samples could be analyzed in one day by running the system overnight. The method is precise and sensitive enough for its intended purpose.  相似文献   

2.
A highly sensitive, simple and selective high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and applied to the determination of bergenin concentration in human plasma. Bergenin and the internal standard (IS) thiamphenicol in plasma were extracted with ethyl acetate, separated on a C(18 )reversed-phase column, eluted with mobile phase of acetonitrile-water, ionized by negative ion pneumatically assisted electrospray and detected in the multi-reaction monitoring mode using precursor --> product ions of m/z 327.1 --> 192 for bergenin and 354 --> 185.1 for the IS, respectively. The linear range of the calibration curve for bergenin was 0.25-60 ng mL(-1), with the lowest limit of quantification of 0.25 ng mL(-1), and the intra/inter-day relative standard deviation (RSD) was less than 10%. The method is suitable for the determination of low bergenin concentration in human plasma after therapeutic oral doses, and has been first and successfully used for its pharmacokinetic studies in healthy Chinese volunteers.  相似文献   

3.
A high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method for the simultaneous quantification of efavirenz, emtricitabine and tenofovir was developed and validated with 100 microL human plasma. Following solid-phase extraction, the analytes were separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 316 to 168 for efavirenz, m/z 248-130 for emtricitabine and m/z 288-176 for tenofovir, m/z 482-258 for rosuvastatin (IS), m/z 260-116 for propranolol (IS). The method exhibited a 100-fold linear dynamic range for all the three analytes in human plasma (20-2000, 2-200 and 20-2000 ng/mL for efavirenz, emtricitabine and tenofovir respectively). The lower limit of quantification was 2 ng/mL for emtricitabine and 20 ng/mL for both efavirenz and tenofovir with a relative standard deviation of less than 11%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 4 min for each sample made it possible to analyze more than 250 human plasma samples per day. The method is precise and sensitive enough for its intended purpose. The method is also successfully applied to quantify efavirenz, emtricitabine and tenofovir concentrations in a rodent pharmacokinetic study.  相似文献   

4.
A rapid, sensitive and specific high-performance liquid chromatography/electrospray ionization mass spectrometric (LC-ESI-MS) method was developed and validated for the quantification of madecassoside, a major active constituent of Centella asiatica (L.) Urb. herbs, in rat plasma. With paeoniflorin as an internal standard (IS), a simple liquid-liquid extraction process was employed for the plasma sample preparation. Chromatographic separation was achieved within 6 min on a Shim-pack CLC-ODS column using acetonitrile and water (60:40, v/v) containing 0.1% (v/v) formic acid as the mobile phase. The detection was performed by MS with electrospray ionization interface in negative selected ion monitoring (SIM) mode. The linear range was 11-5500 ng/mL with the square regression coefficient (r(2) ) of 0.9995. The lower limit of quantification was 11 ng/mL. The intra- and inter- day precision ranged from 4.99 to 9.03%, and the accuracy was between 95.82 and 111.80%. The average recoveries of madecassoside and IS from spiked plasma samples were >92%. The developed method was successfully applied to the pharmacokinetic study of madecassoside in rats after an oral administration.  相似文献   

5.
A method for the simultaneous separation, identification, quantification and confirmation of the presence of 21 glucocorticoids (GCC) in equine plasma by liquid chromatography coupled with triple stage quadrupole tandem mass spectrometry (LC/TSQ-MS/MS) is described. Plasma sample augmented with the 21 GCC was extracted with methyl tert-butyl ether (MTBE) and analyzed by positive electrospray ionization. Desoxymetasone or dichlorisone acetate was used as the internal standard (IS). Quantification was performed by IS calibration. For each drug, one major product ion was chosen and used for screening for that drug. Analyte confirmation was performed by using the three most intense product ions formed from the precursor ion and the corresponding mass ratios. The recovery of the 21 GCC when spiked into blank plasma at 5 ng/mL was 45-200% with coefficient of variation (CV) from 0.3-18%. The limit of detection (LOD) and that of quantification (LOQ) for most of the analytes were 50-100 pg/mL and 1 ng/mL, respectively, whereas that of confirmation (LOC) was 100-300 pg/mL depending on the analyte. Intra- and inter-day precisions expressed as CV for quantification of 1 and 10 ng/mL was 1.0-17%, and 0.51-19%, respectively, and the accuracy was from 84-110%. The linear concentration range for quantification was 0.1-100 ng/mL (r(2) > 0.997). Estimated measurement uncertainty was from 11-37%. This study was undertaken to develop a method for simultaneous screening, identification, quantification and confirmation of these agents in post-race equine plasma samples. The method has been successfully applied to screening of a large number of plasma samples obtained from racehorses in competition and in pharmacokinetic studies of dexamethasone in the horse and concurrent changes in endogenous GCC, hydrocortisone and cortisone. The method is simple, sensitive, selective and reliably reproducible.  相似文献   

6.
A sensitive and specific assay for detection of busulfan in human plasma was developed. The assay is based on rapid isolation of busulfan by liquid-liquid extraction with ethyl acetate, and detection by high-performance liquid chromatography with electrospray ionization and tandem mass spectrometry. 1,6-Bis(methanesulfonyloxy)hexane, a synthesized analogue of busulfan, was used as the internal standard (IS). The acquisition was performed in the multiple reaction monitoring mode; busulfan and the IS were detected with no interferences from plasma matrix. The method was linear over the range 5-2500 ng mL(-1), with r2 > 0.99 and a run time of only 3.5 min. The intra- and inter-assay precisions were in the ranges 2.1-11.9% and 3.2-10.1%, respectively, and the intra- and inter-assay accuracies were 92.2-107.6% and 94.7-104.1%, respectively. The absolute recoveries were 82.0% (20 ng mL(-1)), 90.6% (1000 ng mL(-1)) and 80.0% (2000 ng mL(-1)) for busulfan, and 89.1% for the IS (1000 ng mL(-1)). The limits of detection and quantification were 2 and 5 ng mL(-1), respectively. The validated method was successfully applied to analyze plasma samples obtained from six adults receiving doses of 1 mg kg(-1) in a conditioning regimen prior to bone marrow transplantation. A marked intra-patient variation in busulfan concentrations during the steady state was observed, which limits the application of pharmacokinetic modeling and suggests that continuous therapeutic monitoring is necessary for adequate individualized dosing. In this regard, the present assay brings important advantages relative to other methods described in the literature, i.e., it is highly specific and simple to perform, with a rapid chromatographic run time (3.5 min), and the whole procedure can be completed in 4-5 h, which would permit dose corrections after the third dose allowing earlier and better dosing adjustments towards the target level of busulfan.  相似文献   

7.
A rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of fexofenadine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 502/466 for fexofenadine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 1-500 ng/mL for fexofenadine in human plasma. The lower limit of quantification was 1 ng/mL with a relative standard deviation of less than 5% for fexofenadine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 2 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

8.
A rapid and high sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for the quantification of zolpidem in human EDTA plasma using ondansetron (IS) as an internal standard. The analyte and IS were extracted from human plasma using ethyl acetate and separated on a C18 column (Inertsil-ODS, 5 μm, 4.6 × 50 mm) interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase, which consisted of a mixture of methanol and 20 mM ammonium formate (pH 5.00 ± 0.05; 75:25 v/v), was injected at a flow rate of 0.40 mL/min. The retention times of zolpidem and IS were approximately 1.76 and 1.22. The LC run time was 3 min. The electrospray ionization source was operated in positive ion mode. Multiple reaction monitoring used the [M + H](+) ions m/z 308.13 → 235.21 for zolpidem and m/z 294.02 → 170.09 for the ondansetron, respectively. Five freeze-thaw cycles was established at -20 and -70°C.The linearity of the response/concentration curve was established in human EDTA plasma over the concentration range 0.10-149.83 ng/mL. The lower detection limit [(signal-to-noise (S/N) > 3] was 0.04 ng/mL and the lower limit of quantification (S/N > 10) was 0.10 ng/mL. This LC-MS-MS method was validated with intra-batch and inter-batch precision of 0.52-8.66.The intra-batch and inter-batch accuracy was 96.66-106.11. Recovery of zolpidem in human plasma was 87.00% and IS recovery was 81.60%. The primary pharmacokinetic parameters were T(max) (h) = (1.25 ± 0.725), C(max) (ng/mL) (127.80 ± 34.081), AUC(0→t), = (665.37 ± 320.982) and AUC(0→∞), 686.03 ± 342.952, respectively.  相似文献   

9.
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of pseudoephedrine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple-reaction monitoring mode using the respective [M + H](+) ions, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 2-1000 ng/mL pseudoephedrine in human plasma. The lower limit of quantification was 2 ng/mL with a relative standard deviation of less than 9% for pseudoephedrine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 2 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

10.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

11.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of DRF-4367, a novel cyclooxygenase-2 inhibitor in rat plasma. The assay procedure involved simple liquid/liquid extraction of DRF-4367 and internal standard (IS, celecoxib) from plasma into dichloromethane. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C(18) column (4.6 x 250 mm, 5 microm). The mobile phase consisting of 0.01 M potassium dihydrogen ortho-phosphate (pH 3.2) and acetonitrile (40:60, v/v) was used at a flow rate of 1.0 mL/min. The eluate was monitored using an UV detector set at 247 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of DRF-4367 and IS were 6.6 and 11.2 min, respectively. The standard curve for DRF-4367 was linear (r(2) > 0.999) in the concentration range 0.1-20 micro g/mL. Absolute recovery was >86% from rat plasma for both analyte and IS. The lower limit of quantification of DRF-4367 was 0.1 micro g/mL. The inter- and intra-day precisions in the measurement of quality control samples, 0.1, 0.3, 8.0 and 15.0 microg/mL, were in the range 6.93-9.34% relative standard deviation (RSD) and 0.48-6.59% RSD, respectively. Accuracy in the measurement of QC samples was in the range 91.24-109.36% of the nominal values. Analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. Stability of DRF-4367 was established for 1 month at -80 degrees C. The application of the assay to a pharmacokinetic study in rats is described.  相似文献   

12.
Artemisinin is a widely used antimalarial drug. To evaluate the pharmacokinetics of artemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of artemisinin in rat plasma. For detection, a Sciex API 4000 LC/MS/MS instrument with an electrospray ionization (ESI) TurboIonSpray inlet in the positive ion multiple reaction monitoring (MRM) mode was used to monitor precursor ([M+NH4]+) --> product ions of m/z 300.4 --> 209.4 for artemisinin and m/z 316.4 --> 163.4 for artemether, the internal standard (IS). The plasma samples were pretreated by a simple liquid-liquid extraction with ether. The standard curve was linear (r > 0.99) over the artemisinin concentration range of 1.0-200.0 ng/mL in plasma. The method had a lower limit of quantification of 1.0 ng/mL for artemisinin in 100 microL of plasma, which offered a satisfactory sensitivity for the determination of artemisinin. The intra- and inter-day precisions were measured to be within +/-5.3% and accuracy between -2.6% and 1.2% for all quality control samples, lower limit of quantification and upper limit of quantification samples. The extraction recoveries of artemisinin and the IS were 95.4 +/- 4.5% and 92.8 +/- 3.9%, respectively. This present method was successfully applied to the characterization of the pharmacokinetic profile of artemisinin in rats after oral administration.  相似文献   

13.
A liquid chromatographic mass spectrometric assay for the quantification of azithromycin in human plasma was developed. Azithromycin and imipramine (as internal standard, IS) were extracted from 0.5 mL human plasma using extraction with diethyl ether under alkaline conditions. Chromatographic separation of drug and IS was performed using a C18 column at room temperature. A mobile phase consisting of methanol, water, ammonium hydroxide and ammonium acetate was pumped at 0.2 mL/min. The mass spectrometer was operated in positive ion mode and selected ion recording acquisition mode. The ions utilized for quantification of azithromycin and IS were m/z 749.6 (M + H) + and m/z 591.4 (fragment) for azithromycin, and 281.1 m/z for internal standard; retention times were 6.9 and 3.4 min, respectively. The calibration curves were linear (r2 > 0.999) in the concentration ranges of 10–1000 ng/mL. The mean absolute recoveries for 50 and 500 ng/mL azithromycin and 1 µg/ mL IS were >75%. The percentage coefficient of variation and mean error were <11%. Based on validation data, the lower limit of quantification was 10 ng/mL. The present method was successfully applied to determine azithromycin pharmacokinetic parameters in two obese volunteers. The assay had applicability for use in pharmacokinetic studies. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A sensitive, simple and selective high-performance liquid chromatography-tandem mass spectrometry method was developed and applied to the determination of norcantharidin concentration in human serum. Norcantharidin (NCTD) and cyclophosphamide (IS) in serum were extracted with acetone, separated on a C18 reversed-phase column, gradiently eluted with a mobile phase of acetonitrile-water containing 2 mm ammonium acetate and 0.1% formic acid (pH 3), ionized by positive ion pneumatically assisted electrospray and detected in the multi-reaction monitoring mode using precursor-->product ions of m/z 169.3-->123.1 for NCTD and 261.2-->140.2 for IS, respectively. The linear range of the calibration curve for NCTD was 2.5-50 ng/mL, with a lowest limit of quantification of 2.5 ng/mL, and the intra/inter-day RSD was less than 10%. The method was suitable for determination of low NCTD concentration in human serum after therapeutic oral doses, and has been successfully used for pharmacokinetic studies in healthy Chinese volunteers.  相似文献   

15.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of ragaglitazar [(-) DRF 2725, NNC 61-0029], a novel anti-diabetic agent, in rat plasma. The assay procedure involved simple liquid/liquid extraction of ragaglitazar and internal standard (IS, troglitazone) from plasma into ethyl acetate. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100 - 5C(18) column (4.6 x 250 mm, 5 micro m). Mobile phase consisting of 0.01 M potassium dihydorgen ortho phosphate (pH 3.2) and acetonitrile (30:70, v/v) was used at a flow rate of 1.0 mL/min. The eluate was monitored using an UV detector set at 240 nm. Ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of IS and ragaglitazar were 6.9 and 12.2 min, respectively. The standard curve for ragaglitazar was linear (r(2) > 0.999) in the concentration range 0.2-100 micro g/mL. Absolute recovery was >87% from rat plasma for both analyte and IS. The lower limit of quantification (LLOQ) of ragaglitazar was 0.2 micro g/mL. The inter- and intra-day precision in the measurement of quality control (QC) samples, 0.2, 1.0, 5.0 and 50 micro g/mL, were in the range 1.32-3.70% relative standard deviation (RSD) and 1.19-9.39% RSD, respectively. Accuracy in the measurement of QC samples was in the range 94.28-107.45%. Analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze/thaw cycles. Stability of ragaglitazar was established for 1 month at -20 degrees C. The application of the assay to a pharmacokinetic study in rats is described.  相似文献   

16.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of rosuvastatin (RST), a novel, synthetic and potent HMG-CoA inhibitor in rat plasma. The assay procedure involved simple liquid-liquid extraction of RST and internal standard (IS, ketoprofen) from a small plasma volume directly into acetonitrile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). Mobile phase consisting of 0.05 m formic acid and acetonitrile (55:45, v/v) was used at a flow rate of 1.0 mL/min for the effective separation of RST and IS. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 240 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of RST and IS were 8.6 and 12.5 min, respectively. The standard curve for RST was linear (r2 > 0.999) in the concentration range 0.02-10 microg/mL. Absolute recoveries of RST and IS were 85-110 and >100%, respectively, from rat plasma. The lower limit of quantification (LLOQ) of RST was 0.02 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.02, 0.06, 1.6 and 8.0 microg/mL, were in the range 7.24-12.43% relative standard deviation (RSD) and 2.28-10.23% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.05-112.17% of the spiked nominal values. Both analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. RST was found to be stable for a period of 30 days on storage at -80 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.  相似文献   

17.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

18.
A simple, rapid and reliable high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of curcumin in rat plasma. Plasma was precipitated with acetonitrile after addition of the internal standard (IS), 4-hydroxybenzophenone. Separation was achieved on a Waters muBondapak C(18) column (3.9 x 300 mm, 5 microm) using acetonitrile (55%) and citric buffer, pH 3.0 (45%) as the mobile phase (flow rate = 1.0 mL/min). The UV detection wavelength was 300 and 428 nm for IS and curcumin, respectively. The extraction efficiencies were 97.08, 95.69 and 94.90% for 50, 200 and 1000 ng/mL of curcumin in rat plasma, respectively. The calibration curve was linear over the range 0.02-1 microg/mL with a correlation coefficient of r(2) > 0.999. The intra- and inter-day coefficients of variation were less than 13%, and mean intra- and inter-day errors were less than +/-6% at 50, 200 and 1000 ng/mL of curcumin. This assay was successfully applied to the pharmacokinetic studies of both solubilized curcumin and its polymeric micellar formulation in rats. It was found that polymeric micelles increased the half-life of curcumin 162-fold that of solubilized curcumin and increased the volume of distribution (Vd(ss)) by 70-fold.  相似文献   

19.
A simple high-performance liquid chromatography (HPLC) method has been developed for determination of diclofenac in human plasma. The method was validated on Ace C(18) column using UV detection. The mobile phase consisted of 20 mM phosphate buffer (pH 7) containing 0.1% trifluoroacetic acid-acetonitrile (65:35, v/v). Calibration curve was linear between the concentration range of 75-4000 ng/mL. Intra- and inter-day precision values for diclofenac in plasma were less than 3.6, and accuracy (relative error) was better than 5.3%. The limits of detection and quantification of diclofenac were 25 and 75 ng/mL, respectively. Also, this assay was applied to determine the pharmacokinetic parameters of diclofenac in healthy Turkish volunteers who had been given 50 mg diclofenac.  相似文献   

20.
A liquid chromatography–tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7‐hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7‐hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5–100 ng/mL for granisetron and 0.1–100 ng/mL for 7‐hydroxy granisetron in human plasma samples, and 2–2000 ng/mL for granisetron and 2–1000 ng/mL for 7‐hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was <10%. No significant matrix effects were observed for granisetron or 7‐hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号