1.
采用组合式热管换热器作为生活浊水余热热泵热水器的热管蒸发器,并在试验台上进行了不同污水进口温度和不同污水流量的可视化试验,通过分析试验结果,发现组合式热管上升管和下降管的温差很大的现象,这与热管特性相矛盾。采用理论分析和实验相结合的方法,研究了热管中产生温差的原因。它主要是由于下降管压力损失较大,使热管工质在热管蒸发器中的滞留引起。  相似文献   

2.
An experimental study of the performance of an air-to-air thermosyphon-based heat exchanger utilizing R-22 as the working fluid has been carried out to investigate its behavior under different operating conditions. A test installation has been developed to model a variety of HVAC real life applications. The results reported in this article describe the influence of various parameters such as: supply and exhaust air stream mass flow rates, stream temperatures and exhaust stream moisture content on the effectiveness of the heat exchangers. Heat exchanger heat flow hysteresis has been recognized. Some optimization criteria are presented.  相似文献   

3.
为了优化脉动热管传热性能,提出了一种脉动热管强化相变材料蓄热的新思路,设计并搭建了一套脉动热管式相变蓄热装置试验平台.以甲醇为工质,八水氢氧化钡为相变材料,分析不同工况下相变材料在蓄热装置中温度随时间的变化.结果 表明,相变材料在蓄热器中的温度和流量越大,装置相变蓄热效果更为显著,但温度与流量不宜过大,否则会影响强化传...  相似文献   

4.
This paper presents an experimental study of waste heat recovery shell-and-tube heat exchangers. The exchanger heat duty, overall heat transfer coefficient, effectiveness and tubeside friction factor are investigated as functions of the tube surface geometry (plain or dimpled), the flow type (counter or parallel), the tube Reynolds number and the shellside heat capacity rate. Water and the exhaust gases of a Diesel engine are passed inside the tube and the shell, respectively.The heat transfer characteristics increase with an increase in tube Reynolds number and the shellside heat capacity rate, for all the flow types and the surface geometries examined. The counter-flow, shell-and-dimpled-tube heat exchanger, compared with that exchanger having a plain tube, increases the heat duty and the overall heat transfer coefficient by 80%, and the heat exchanger -effectiveness increases by 35%. For the parallel-flow, shell-and-dimpled-tube heat exchanger, the heat duty, the overall heat transfer coefficient and the effectiveness increase by 30, 55, and 25%, respectively. At the same time the dimpled tube increases the tubeside friction factor by 600% over that of the plain tube. The rate of waste heat recovered from the exhaust gases of the Diesel engine by the counter-flow, shell-and-dimpled-tube heat exchanger is equal to 10% of the maximum brake power of the engine running at 1500 rpm, and the tube Reynolds number equal to 8875.  相似文献   

5.
径向热管传热的数值计算及结果分析   总被引:1,自引:0,他引:1  
采用计算流体力学软件首先对无吸液芯径向热管管壁的温度进行数值计算,其次模拟无吸液芯径向热管中蒸汽的层流对流换热的情况,得出其温度场分布和速度场分布,并对结果进行分析。  相似文献   

6.
An experimental energy storage system has been designed using a new type flat micro heat pipe heat exchanger that incorporates a moderate-temperature phase change material paraffin with a melting point of 58°C. The basic structure, working principles, and design concept are discussed. The heat transfer process during the charging and discharging of the heat exchanger under various operating conditions has been experimentally investigated. Results show that the performance of the new type flat micro heat pipe was steady and efficient during charging and discharging. The average thermal storage power and absorption efficiency have been determined to be approximately 537 W and 92.5%, respectively.  相似文献   

7.
针对新风空调机组,采用倾角为15°的分离式热管用于显热回收.研究充液率,迎面风速及空气进口温度对显热效率的影响,分析了其影响规律.研究表明,采用热管空调机组设计风速范围内,充液率介于66%~75%时,其换热效率最高.迎面风速较低时,空气进口温度介于34℃~36℃,其显热效率较高.因此,采用分离式热管机组适合用于高热地区...  相似文献   

8.
The flow boiling heat transfer of water in a microchannel heat sink with variable initial vapor quality at the inlet is investigated. The stainless steel microchannel heat sink contains ten 640 × 2050 μm channels with a length of 120 mm; the wall roughness is 10 μm. The data on the local heat-transfer coefficient distribution in heat sink length are obtained in the range of mass fluxes from 30 to 90 kg/m2s, heat fluxes from 40 to 170 kW/m2, and vapor qualities from 0 to 1. The heat transfer instability associated with dry spots resulting from insufficient wetting of channel walls introduces substantial contribution to the heat transfer mechanism and leads to decreasing heat transfer in heat sink length downward the flow. The developed method for calculating the flow boiling heat transfer of water in a microchannel heat sink allows more accurate prediction of heat transfer drop than available methods.  相似文献   

9.
换热器空气侧换热效率低是换热器领域的难点,管翅换热器是目前应用广泛、性能较优的换热器。为了寻求更好的换热器制作材料,以铜网片替代管翅换热器的板翅片,研制三种与市售管翅换热器同等尺寸(40×80×180 mm)的网翅片换热器进行换热性能实验对比,实验结果表明:研制的网翅片换热器相比于管翅换热器,在自然对流下热阻能降低35%;在强制对流下热阻能降低75%,网翅片换热器的温升是管翅换热器的20%。  相似文献   

10.
11.
The conditions of heat transfer intensification using short local heat pulses applied to a heater cooled by fluids with a boiling curve hysteresis (cryogenic, organic fluids, and others) are considered.  相似文献   

12.
热管技术已在电子设备散热领域得到广泛应用。热管的传热能力虽然很大,但不能无限加大热负荷。文中讨论了热管的主要极限如沸腾极限、毛细极限、粘性极限、声速极限、携带极限等的理论表达式,就一种实验用微槽平板热管进行了理论计算,得出了毛细极限是实验热管主要传热极限的结论。  相似文献   

13.
A scheme is described for the recovery of waste heat from stacks of gas turbine engines and the utilization of recovered energy for the cooling of ambient air. Relationships are summarized for the modeling of components of the cooling system. Samples are presented from performance data that is predicted by the model. Effect of size and design of system components, as well as operational variables on system performance, are discussed. It is concluded that the single most significant variable in the design of the looped heat-pipe recovery and utilization system is the geometry of the exhaust pipe of the gas turbine engine. Accordingly it is suggested that a design for the exhaust pipe of a gas turbine must consider the effects of (a) the variation of velocity of exhaust gases at different exhaust inlet temperatures, and the consequent pressure drops in the exhaust chimney pipe, and (b) the length of the exhaust pipe. The latter essentially determines the length of the heat pipe evaporator. Furthermore, the temperature drop through the air cooler is also significant, since this also influences system performance.  相似文献   

14.
15.
The heat capacity at constant pressure (in the range 3–50 K) and the lattice heat conductivity (from 5 to 75 K) of a single-crystal synthetic opal are measured. It is shown that the heat capacity of the opal behaves at these temperatures in a way similar to porous amorphous materials. The data on the heat conductivity suggest that single-crystal opals can be related to a class of semicrystalline (partially crystallized amorphous) materials. However, because of specific features of their crystal structure, the opals form a nonstandard type of semicrystalline material which we termed semiamorphous.  相似文献   

16.
气液双热源耦合换热器性能研究   总被引:2,自引:1,他引:1  
设计了一种由管翅式换热器和套管式换热器耦合而成的气液双源耦合式换热器,该换热器可以实现一种介质同时与气态热源和液态热源进行同步耦合换热.对该换热器进行了详细的介绍,并对其耦合换热特性及该换热器在耦合热源热泵空调中应用时的制热工况进行了的性能测试.研究结果证明,使用该气液双热源耦合式换热器的耦合热源热泵空调系统,气液双热...  相似文献   

17.
随着纳米流体用于换热器的强化换热,纳米流体热管换热器的研究逐步扩展到各个领域,从航天到化工,从电子到能源。纳米流体热管由于表面温度低,较高的传热系数和较小的热阻,受到了广泛的关注。文中总结了纳米流体热管国内外的最新研究进展。  相似文献   

18.
The specific heat and the heat flux exchanged by a single crystal of KMnF3 have been measured simultaneously while cooling the sample at constant rate of 0·06 K/h through the phase transition at T 0= 186 K. The phase transition is weakly first order and close to a tricritical point. The temperature dependence at T185 K of the excess specific heat and the excess entropy follow very well the predictions of a Landau potential at a tricritical point.  相似文献   

19.
芯片冷却用热管散热器的数值模拟研究   总被引:1,自引:1,他引:0  
随着计算机性能的提高,CPU散热量也持续增大,并导致了能量分布不均匀,所以高热流密度热控制或大型服务器的冷却处理方式已受到广泛关注。文中对大型计算机服务器CPU的耗能量、冷却效果等进行了实验研究,提出通过采用导热板扩大CPU散热面积的同时,采用高导热相变方法来解决高热流密度器件冷却的处理办法。研究结果证实,对高热流密度器件,依靠增大外界气流的速度来改善散热器的冷却性能并不明显,采用高效热管散热器来强化芯片传热,可满足计算机服务器CPU的冷却要求。  相似文献   

20.
The conjugate problem on heat transfer in a system of subsurface channel one-duct heat pipeline-environment is solved by the finite element method. Thermal regimes of the heat pipeline are analyzed, depending on the temperature at the internal boundary of the system. Values of the main characteristics of the system are found and adequacy of the proposed model is validated.  相似文献   