共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
《Heat Recovery Systems and CHP》1991,11(1):69-77
An experimental study of the performance of an air-to-air thermosyphon-based heat exchanger utilizing R-22 as the working fluid has been carried out to investigate its behavior under different operating conditions. A test installation has been developed to model a variety of HVAC real life applications. The results reported in this article describe the influence of various parameters such as: supply and exhaust air stream mass flow rates, stream temperatures and exhaust stream moisture content on the effectiveness of the heat exchangers. Heat exchanger heat flow hysteresis has been recognized. Some optimization criteria are presented. 相似文献
3.
4.
《Heat Recovery Systems and CHP》1988,8(4):299-308
This paper presents an experimental study of waste heat recovery shell-and-tube heat exchangers. The exchanger heat duty, overall heat transfer coefficient, effectiveness and tubeside friction factor are investigated as functions of the tube surface geometry (plain or dimpled), the flow type (counter or parallel), the tube Reynolds number and the shellside heat capacity rate. Water and the exhaust gases of a Diesel engine are passed inside the tube and the shell, respectively.The heat transfer characteristics increase with an increase in tube Reynolds number and the shellside heat capacity rate, for all the flow types and the surface geometries examined. The counter-flow, shell-and-dimpled-tube heat exchanger, compared with that exchanger having a plain tube, increases the heat duty and the overall heat transfer coefficient by 80%, and the heat exchanger -effectiveness increases by 35%. For the parallel-flow, shell-and-dimpled-tube heat exchanger, the heat duty, the overall heat transfer coefficient and the effectiveness increase by 30, 55, and 25%, respectively. At the same time the dimpled tube increases the tubeside friction factor by 600% over that of the plain tube. The rate of waste heat recovered from the exhaust gases of the Diesel engine by the counter-flow, shell-and-dimpled-tube heat exchanger is equal to 10% of the maximum brake power of the engine running at 1500 rpm, and the tube Reynolds number equal to 8875. 相似文献
5.
径向热管传热的数值计算及结果分析 总被引:1,自引:0,他引:1
采用计算流体力学软件首先对无吸液芯径向热管管壁的温度进行数值计算,其次模拟无吸液芯径向热管中蒸汽的层流对流换热的情况,得出其温度场分布和速度场分布,并对结果进行分析。 相似文献
6.
An experimental energy storage system has been designed using a new type flat micro heat pipe heat exchanger that incorporates a moderate-temperature phase change material paraffin with a melting point of 58°C. The basic structure, working principles, and design concept are discussed. The heat transfer process during the charging and discharging of the heat exchanger under various operating conditions has been experimentally investigated. Results show that the performance of the new type flat micro heat pipe was steady and efficient during charging and discharging. The average thermal storage power and absorption efficiency have been determined to be approximately 537 W and 92.5%, respectively. 相似文献
7.
8.
The flow boiling heat transfer of water in a microchannel heat sink with variable initial vapor quality at the inlet is investigated.
The stainless steel microchannel heat sink contains ten 640 × 2050 μm channels with a length of 120 mm; the wall roughness
is 10 μm. The data on the local heat-transfer coefficient distribution in heat sink length are obtained in the range of mass
fluxes from 30 to 90 kg/m2s, heat fluxes from 40 to 170 kW/m2, and vapor qualities from 0 to 1. The heat transfer instability associated with dry spots resulting from insufficient wetting
of channel walls introduces substantial contribution to the heat transfer mechanism and leads to decreasing heat transfer
in heat sink length downward the flow. The developed method for calculating the flow boiling heat transfer of water in a microchannel
heat sink allows more accurate prediction of heat transfer drop than available methods. 相似文献
9.
换热器空气侧换热效率低是换热器领域的难点,管翅换热器是目前应用广泛、性能较优的换热器。为了寻求更好的换热器制作材料,以铜网片替代管翅换热器的板翅片,研制三种与市售管翅换热器同等尺寸(40×80×180 mm)的网翅片换热器进行换热性能实验对比,实验结果表明:研制的网翅片换热器相比于管翅换热器,在自然对流下热阻能降低35%;在强制对流下热阻能降低75%,网翅片换热器的温升是管翅换热器的20%。 相似文献
10.
11.
D. M. Kuzmenkov M. I. Delov K. V. Kutsenko A. A. Lavrukhin 《Bulletin of the Lebedev Physics Institute》2016,43(11):328-331
The conditions of heat transfer intensification using short local heat pulses applied to a heater cooled by fluids with a boiling curve hysteresis (cryogenic, organic fluids, and others) are considered. 相似文献
12.
热管技术已在电子设备散热领域得到广泛应用。热管的传热能力虽然很大,但不能无限加大热负荷。文中讨论了热管的主要极限如沸腾极限、毛细极限、粘性极限、声速极限、携带极限等的理论表达式,就一种实验用微槽平板热管进行了理论计算,得出了毛细极限是实验热管主要传热极限的结论。 相似文献
13.
《Heat Recovery Systems and CHP》1994,14(4):365-376
A scheme is described for the recovery of waste heat from stacks of gas turbine engines and the utilization of recovered energy for the cooling of ambient air. Relationships are summarized for the modeling of components of the cooling system. Samples are presented from performance data that is predicted by the model. Effect of size and design of system components, as well as operational variables on system performance, are discussed. It is concluded that the single most significant variable in the design of the looped heat-pipe recovery and utilization system is the geometry of the exhaust pipe of the gas turbine engine. Accordingly it is suggested that a design for the exhaust pipe of a gas turbine must consider the effects of (a) the variation of velocity of exhaust gases at different exhaust inlet temperatures, and the consequent pressure drops in the exhaust chimney pipe, and (b) the length of the exhaust pipe. The latter essentially determines the length of the heat pipe evaporator. Furthermore, the temperature drop through the air cooler is also significant, since this also influences system performance. 相似文献
14.
15.
V. N. Bogomolov L. S. Parfen’eva I. A. Smirnov H. Misiorek A. Jezowski A. I. Krivchikov B. I. Verkin 《Physics of the Solid State》2001,43(1):190-193
The heat capacity at constant pressure (in the range 3–50 K) and the lattice heat conductivity (from 5 to 75 K) of a single-crystal synthetic opal are measured. It is shown that the heat capacity of the opal behaves at these temperatures in a way similar to porous amorphous materials. The data on the heat conductivity suggest that single-crystal opals can be related to a class of semicrystalline (partially crystallized amorphous) materials. However, because of specific features of their crystal structure, the opals form a nonstandard type of semicrystalline material which we termed semiamorphous. 相似文献
16.
17.
18.
F. J. Romero M. C. Gallardo J. Jiménez J. Del Cerro E. K. H. Salje A. Gibaud 《Phase Transitions》2013,86(3):523-531
The specific heat and the heat flux exchanged by a single crystal of KMnF3 have been measured simultaneously while cooling the sample at constant rate of 0·06 K/h through the phase transition at T 0= 186 K. The phase transition is weakly first order and close to a tricritical point. The temperature dependence at T185 K of the excess specific heat and the excess entropy follow very well the predictions of a Landau potential at a tricritical point. 相似文献
19.
20.
The conjugate problem on heat transfer in a system of subsurface channel one-duct heat pipeline-environment is solved by the
finite element method. Thermal regimes of the heat pipeline are analyzed, depending on the temperature at the internal boundary
of the system. Values of the main characteristics of the system are found and adequacy of the proposed model is validated. 相似文献