1.
Thiol compounds such as cysteine (Cys), reduced (GSH) and oxidized (GSSG) gluathione, and phytochelatins (PCs) play an important role in heavy metal detoxification in plants. These thiols are biological active compounds whose function is elimination of oxidative stress in plant cells. The aim of our work was to optimise sensitive and rapid method of high-performance liquid chromatography coupled with electrochemical detector (HPLC-ED) for determination of the abovementioned thiol compounds in maize (Zea mays L.) kernels. New approach for evaluation of HPLC-ED parameters is described. The most suitable isocratic mobile phase for the separation and detection of Cys, GSH, GSSG and PC2 consisted of methanol (MeOH) and trifluoroacetic acid (TFA). In addition, the influence of concentrations of TFA and ratio of MeOH:TFA on chromatographic separation and detection of the thiol compounds were studied. The mobile phase consisting from methanol and 0.05% (v/v) TFA in ratio 97:3 (%; v/v) was found the most suitable for the thiol compounds determination. Optimal flow rate of the mobile phase was 0.18 ml min(-1) and the column and detector temperature 35 degrees C. Hydrodynamic voltammograms of all studied compounds was obtained due to the selection of the most effective working electrodes potentials. Two most effective detection potentials were selected: 780 mV for the GSSG and PC2 and 680 mV for determination of Cys and GSH. The optimised HPLC-ED method was capable to determine femtomole levels of studied compounds. The detection limits (3 S/N) of the studied thiol compounds were for cysteine 112.8 fmol, GSH 63.5 fmol, GSSG 112.2 fmol and PC2 2.53 pmol per injection (5 microl). The optimised HPLC-ED method was applied to study of the influence of different cadmium concentrations (0, 10 and 100 microM Cd) on content of Cys, GSH, GSSG and PC2 in maize kernels. According to the increasing time of Cd treatment, content of GSH, GSSG and PC2 in maize kernels increased but content of Cys decreased. Decreasing Cys concentration probably relates with the increasing GSH and phytochelatins synthesis.  相似文献   

2.
Glutathione (GSH) and glutathione disulfide (GSSG) levels in cells constitute a thiol redox system. They can be used as an indicator of oxidative stress of the cell. In this study, a capillary zone electrophoresis (CZE) method is described that enables quantitation of GSH and GSSG from cellular extracts. The CZE buffer used was 20 mM ammonium acetate containing 5% (v/v) acetic acid at pH 3.1 in conjunction with a polybrene coated capillary operated in reverse polarity mode. Effects of different acids used to prepare cell samples were investigated on CZE performance. The acids include meta phosphoric acid (MPA), trichloroacetic acid (TCA), phosphoric acid (PA) and sulfosalicylic acid (SSA) and are used to stabilize GSH and GSSG before performing CZE analysis. The method features a limit of detection of 4 microM and a limit of quantitation of 12 microM for both GSSG and GSH and recoveries of 94% for GSH and 100% for GSSG. Quantitative analysis of GSSG and GSH in HaCaT cell extracts (5% SSA, w/v) was performed with this method and changes in the ratio of GSH to GSSG in N-ethylmaleimide treated cell sample was observed by comparing with control cell samples.  相似文献   

3.
Li  Min  Mao  Sifeng  Wang  Shiqi  Li  Hai-Fang  Lin  Jin-Ming 《中国科学:化学(英文版)》2019,62(1):142-150
Alterations in the ratio of glutathione(GSH) to glutathione disulfide(GSSG) reveal the cell living state and are associated with a variety of diseases. In this study, an Au NPs grafted nanoporous silicon chip was used for surface assisted laser desorption ionization-mass spectrometry(SALDI-MS) detection of GSH. Due to the bond interaction between thiol of GSH and Au NPs modified on the chip surfaces, GSH could be captured from the complex cellular lysate. Meanwhile, the composite nanostructures of Au NPs grafted porous silicon surface presented good desorption/ionization efficiency for GSH detection. The GSH levels in different tumor cells were successfully detected. Chip-based SALDI-MS was optimized for quantification of intracellular GSH/GSSG ratio changing under drug stimulation in liver tumor cells, GSSG was reduced to GSH by reductant of tris(2-carboxyethyl)phosphine(TCEP) and isotope-labeling GSH was as an internal standard. It was found that the increasing concentration of drug irinotecan and hypoxia culture condition caused the rapid consumption of GSH and a decrease of GSH/GSSG ratio in liver tumor cells. The developed SALDI-MS method provided a convenient way to accurately measure and rapidly monitor cellular GSH value and the ratios of GSH/GSSG.  相似文献   

4.
Ding Y  Garcia CD 《The Analyst》2006,131(2):208-214
A miniaturized analytical system for separation and detection of three EPA priority phenolic pollutants, based on a poly(dimethylsiloxane)-fabricated capillary electrophoresis microchip and pulsed amperometric detection is described. The approach offers a rapid (less than 2 min), simultaneous measurement of three phenolic pollutants: phenol, 4,6-dinitro-o-cresol and pentachlorophenol. The highly stable response (RSD = 6.1%) observed for repetitive injections (n > 100) reflects the effectiveness of Au working electrode cleaned by pulsed amperometric detection. The effect of solution conditions, separation potential and detection waveform were optimized for both the separation and detection of phenols. Under the optimum conditions (5.0 mM phosphate buffer pH = 12.4, detection potential: 0.7 V, separation potential: 1200 V, injection time: 10 s) the baseline separation of the three selected compounds was achieved. Limits of detection of 2.2 microM (2.8 fmol), 0.9 microM (1.1 fmol), and 1.3 microM (1.6 fmol) were achieved for phenol, 4,6-dinitro-o-cresol and pentachlorophenol, respectively. A local city water sample and two over-the-counter sore-throat medicines were analyzed in order to demonstrate the capabilities of the proposed technique to face real applications.  相似文献   

5.
A reverse-phase HPLC method incorporating dithiothreitol (DTT) reduction for quantitative determination of oxidized glutathione (GSSG) in biological samples is described here. This method is based on our previous enzymatic reduction technique that uses N-1-(pyrenyl) maleimide (NPM) as a derivatizing agent. In our earlier method, glutathione disulfide (GSSG) was measured by first reducing it to GSH with glutathione reductase (GR) in the presence of NADPH. However, this is a very costly and time-consuming technique. The method described here employs a common and inexpensive thiol-disulfide exchanging agent, DTT, for reduction of GSSG to GSH, followed by derivatization with NPM. The calibration curves are linear over a concentration range of 25-1250 nm (r(2) > 0.995). The coefficients of variations for intra-run precision and inter-run precision range from 0.49 to 5.10% with an accuracy range of 1.78-6.15%. The percentage of relative recovery ranges from 97.3 to 103.2%. This new method provides a simple, efficient, and cost-effective way of determining glutathione disulfide levels with a 2.5 nm limit of detection per 5 microL injection volume.  相似文献   

6.
S A Wring  J P Hart  B J Birch 《The Analyst》1989,114(12):1571-1573
High-performance liquid chromatography with electrochemical detection (LCEC), incorporating a novel carbon-epoxy resin working electrode modified with cobalt phthalocyanine, has been employed for preliminary studies directed towards the determination of normal circulating levels of reduced glutathione (GSH) in human plasma. The mobile phase consisted of 0.05 M phosphate buffer (pH 3) containing 0.1% m/m ethylenediaminetetraacetic acid (EDTA); the calibration graph was linear in the range 0.24-30.7 ng of GSH injected. The mean recovery of GSH added to a control serum over the physiological concentration range (0.38-3.07 ng ml-1) was 99%; this was achieved following a simple sample pre-treatment method, prior to LCEC, involving chelation of divalent cations with EDTA and subsequent acidification with orthophosphoric acid. Using the LCEC method, the mean circulating level of GSH in plasma, found in three normal subjects, was 2.69 microM, GSH; this indicates that the method might be applicable to the determination of depressed circulating levels of GSH.  相似文献   

7.
A rapid method of capillary zone electrophoresis is described to determine the oxidized (GSSG) and reduced (GSH) form of glutathione in plant tissue. In order to separate both analytes in a fused-silica capillary, the pH and composition of the electrolyte solution were optimized. The electrolyte composition was 100 mmol/L, borate 25 mmol/L Tris, and 0.2% w/v metaphosphoric acid (MPA), pH 8.2. Some instrumental conditions used to run the samples were hydrostatic injection for 30 s, 30 kV applied voltage, and UV detection (185 nm) at 25 degrees C. Linearity and useful range obtained for the calibration curves were optimum, with correlation coefficients about 0.999 in the 0-120 micromol/L range. The migration time was highly reproducible, less than 5 min being afforded to run a sample. Electrolyte buffer and samples required a careful pH control for optimal separation of both analytes. This aspect constitutes a critical analytical step when acids are used in the procedure for sample preparation. Simultaneous analysis of GSH and GSSG may provide a useful tool for comparative studies of plants in order to select those species with a potential capacity for detoxification from toxic elements or those appearing promising from phytoremediation for these elements.  相似文献   

8.
Measurement of glutathione (GSH) and glutathione disulfide (GSSG) is a crucial tool to assess cellular redox state. Herein we report a direct approach to determine intracellular GSH based on a rapid chromatographic separation coupled with acidic potassium permanganate chemiluminescence detection, which was extended to GSSG by incorporating thiol blocking and disulfide bond reduction. Importantly, this simple procedure avoids derivatisation of GSH (thus minimising auto-oxidation) and overcomes problems encountered when deriving the concentration of GSSG from 'total GSH'. The linear range and limit of detection for both analytes were 7.5 × 10(-7) to 1 × 10(-5) M, and 5 × 10(-7) M, respectively. GSH and GSSG were determined in cultured muscle cells treated for 24 h with glucose oxidase (0, 15, 30, 100, 250 and 500 mU mL(-1)), which exposed them to a continuous source of reactive oxygen species (ROS). Both analyte concentrations were greater in myotubes treated with 100 or 250 mU mL(-1) glucose oxidase (compared to untreated controls), but were significantly lower in myotubes treated with 500 mU mL(-1) (p < 0.05), which was rationalised by considering measurements of H(2)O(2) and cell viability. However, the GSH/GSSG ratio in myotubes treated with 100, 250 and 500 mU mL(-1) glucose oxidase exhibited a dose-dependent decrease that reflected the increase in intracellular ROS.  相似文献   

9.
p-Nitroaniline was explored as a derivatising reagent for UV absorbance detection of carbohydrates after separation by CE. This derivatising agent has three advantages: first, it has excellent water solubility; second, it has high molar absorptivity; and third, it is possible to obtain sensitive detection using a UV or blue light-emitting diode (LED) as the light source. The labelling reaction took less than 30 min to complete with high reaction yield. The separation process was modelled and optimised using an artificial neural network. Nine carbohydrates were separated by a CE system within 16 min using a 0.17 M boric acid buffer at pH 9.7. On-column LED detection at 406 nm allowed the detection of carbohydrates with good detection limits (<1.1 microM or 8.8 fmol) and reproducible quantification in the concentration range of 2.6-200 microM. This method was applied successfully to the determination of component carbohydrates in some food samples.  相似文献   

10.
A rapid method using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) was developed to determine free and protein-bound glutathione (GSH) in human HepG2 hepatocarcinoma cells. The samples were derivatized with 5-iodoacetamidofluorescein (5-IAF), and analyzed at 22 kV using sodium phosphate buffer (10mM, pH 11.4) and an uncoated 58 cm x 75 microm I.D. fused silica capillary. The analysis time was less than 10 min and N-acetylcysteine was used as internal standard. The derivatization conditions, such as reaction time, 5-IAF concentration, running buffer and cartridge temperature were optimized. Argon gas was used in the study to prevent the oxidization of GSH during sample preparation. The optimized method required only 30-40 nl sample per analysis and was fast and sensitive. The method was applied to the analyses of HepG2 cells treated with the small metal chelating agent, pyrrolidine dithiocarbamate (PDTC). The results demonstrate that the amount of protein-bound GSH, which reflects the amount of protein S-glutathionylation, increased in a time-dependent manner upon cell treatment with PDTC, reaching a maximum of over 50% increase 2h post-PDTC.  相似文献   

11.
Banica FG  Fogg AG  Moreira JC 《Talanta》1995,42(2):227-234
Oxidized glutathione (GSSG) can be determined after previous accumulation on the HMDE at E > -0.2 V (vs. the Ag AgCl reference electrode). GSH is formed during the accumulation, possibly by a mercury-ion-assisted hydrolytic disproportionation of GSSG. In the subsequent cathodic scan GSH is released and catalyses the reduction of nickel ion, giving a peak located at -0.6 V. This enables the determination of GSSG by differential-pulse cathodic stripping voltammetry at pH 7.0 in the phosphate acetate or MOPS buffer containing 0.5-1.0 mM Ni(II). The detection limit is 10 nM. The calibration graph is linear even in the presence of small amounts of human serum albumin, HSA. However, HSA increases the detection limit (20 nM for 3 x 10(-4)% HSA). Acetyl-cysteine in small excess or Cu(II) present as reagent impurity do not interfere. Glutathione, cysteine and similar compounds, which accumulate as mercury salts and form stable nickel complexes, will interfere. The method is put forward as a novel alternative stripping voltammetric method to those involving accumulation and determination as mercury or copper salts and complexes, in the knowledge that it may have advantages in particular analytical situations. In particular the method discriminates against compounds which accumulate as mercury salts but which do not form stable nickel complexes.  相似文献   

12.
A method for the simultaneous quantification of reduced and oxidized glutathione in human plasma employing a two-dimensional chromatographic system with parallel porous graphitized carbon (PGC) columns coupled with fluorescence (FLD) and coulometric electrochemical detection (ED) has been developed. Post-sampling oxidation of reduced glutathione (GSH) was prevented by derivatizing the -SH group with monobromobimane (MBB) and the glutathione-bimane adduct (GSMB) was detected by FLD. Oxidized glutathione (GSSG) was detected by ED optimized to give lowest possible limits of detection (LOD). The method is fully validated and is currently used for determination of GSH, GSSG and its redox potential in different clinical studies.  相似文献   

13.
Araujo AR  Saraiva ML  Lima JL 《Talanta》2008,74(5):1511-1519
This work reports the development of a simple, robust, automated sequential injection analysis (SIA) system for the enzymatic determination of total (tGSH) and oxidized (GSSG) glutathione in human whole blood. The reduced (GSH) glutathione concentration is then obtained as the difference between the tGSH and GSSG concentrations. The determination was based on the DTNB–GSSG reductase recycling assay, which couples the specificity of the GSSG reductase (GR) with an amplification of the response to glutathione, followed by spectrophotometric detection of the 2-nitro-5-thiobenzoic acid (TNB) formed (λ = 412 nm). The implementation of this reaction in a SIA flow system with an in-line dilution strategy permitted the necessary distinct application ranges for tGSH and for GSSG. It also guaranteed the exact timing of fluidic manipulations and precise control of the reaction conditions.

The influence of parameters such as reagents concentration, temperature, pH, flow rate of the carrier buffer solution, as well as reaction coil length, etc., on the sensitivity and performance of the SIA system were studied and the optimum reaction conditions subsequently selected. Linear calibration plots were obtained for GSH and GSSG concentrations up to 3.00 and 1.50 μM, with detection limits of 0.031 and 0.014 μM, respectively. The developed methodology showed good precision, with a relative standard deviation (R.S.D.) < 5.0% (n = 10) for determination of both glutathione forms. Statistical evaluation showed good compliance, for a 95% confidence level, between the results obtained with the SIA system and those furnished by the comparison batch procedure.  相似文献   


14.
We describe a very rapid high-performance capillary electrophoresis method for the separation and quantification of reduced (GSH) and oxidized (GSSG) glutathione in red blood cells. Two procedures for sample preparation have been compared, Microcon-10 membrane filtration and acid precipitation. The separation is obtained in an uncoated capillary using a high ionic strength borate buffer at pH 7.8. The intra-assay coefficients of variation (CVs%) are 1.53 and 1.66 for GSH and GSSG, respectively. The run is shorter than 90 s and the migration time is highly reproducible both for GSH (CV% 0.22) and GSSG (CV% 0.17). When the filtration step is used only GSH is found, whereas both GSH and GSSG are detectable after acid precipitation, suggesting that GSSG revealed after acid treatment may be an artefact due to GSH oxidation. Because of its good analytical performance this method could be used for routine red blood cell glutathione measurement in healthy or pathological conditions.  相似文献   

15.
建立了胶束电动毛细管色谱结合电化学安培检测同时分析中药马齿苋中多巴胺和去甲肾上腺素的方法。考察了缓冲液的浓度、pH值、十二烷基硫酸钠(SDS)浓度以及工作电极电势对分离检测的影响。在优化的条件下,多巴胺和去甲肾上腺素在1.0×10-6~5 0×10-4mol/L范围内有良好线性,浓度检测限(S/N=3)分别为8 7×10-7mol/L和4 2×10-7mol/L,质量检测限分别为1 45fmol和0 41fmol。该方法组分定性可靠,不需要衍生处理,选择性好。将该法应用于中药马齿苋样品的分析,获得了较好的结果。  相似文献   

16.
A method based on capillary electrophoresis (CE) with electrochemical (EC) detection for the determination of both total homocysteine (tHcy) and protein-bound homocysteine (pbHcy) in plasma is described. Both end-column and off-column amperometric detection were investigated. Off-column detection resulted in a more sensitive assay for the determination of homocysteine (Hcy). The detection limit for homocysteine was 500 nM using off-column EC detection and the response was linear over the range 1-100 microM. Therefore, this assay is appropriate for the quantification of Hcy over the physiological concentration ranges found in all disease states. Methodologies for the determination of tHcy and pbHcy in human plasma were investigated and optimized and the concentrations of both pbHcy and tHcy in plasma obtained from a healthy individual were determined to be 2.79+/-0.31 nuM (n = 4) and 3.37+/-0.15 microM (n = 3), respectively. The methodology was then transferred to a microchip CE-EC format and Hcy and reduced glutathione (GSH) were detected. Future work will focus on the development of ancillary methodologies to identify the other forms of Hcy in vivo.  相似文献   

17.
This study aimed to develop a HPLC/DAD method in order to determine and quantify the reduced glutathione (GSH) and oxidized glutathione (GSSG) levels in rat brain. Due to the presence of the thiol group (-SH), GSH can interact with the Ellman′s reagent (DTNB), with which it forms a reaction product through which the level of GSH can be quantified, using the DAD detection system. Chromatographic separation was achieved after a derivatization process by using a mobile phase acetonitrile (A) and phosphate buffer (20 mM, pH = 2.5) (B). The compounds of interest were detected at 330 nm using a chromatographic C8 column. The method of determination met the validation criteria, specified by the regulatory bodies. The applicability of the method was demonstrated in a chronic toxicology study of central nervous system (CNS), following different treatment regimens with haloperidol.  相似文献   

18.
Pai YF  Lin CC  Liu CY 《Electrophoresis》2004,25(4-5):569-577
A wall-coated histidine capillary column was developed for the on-line preconcentration of nonsteroidal anti-inflammatory drugs (NSAIDs) in capillary electrochromatography (CEC). A wide variety of experimental parameters, such as the sample buffer, background electrolyte (BGE) composition, concentration, sample plug lengths, water plug, and the effect of organic modifiers were studied. The relationship between peak height and injection times for the NSAIDs by variation of sample and BGE buffer concentration was investigated. On addition of sodium chloride (0.3-0.6%) to the sample zone, the stacking efficiency was increased. With acetate buffer (100 mM, pH 5.0)/ethanol (20% v/v) as BGE and sample solution in acetate buffer (0.2 mM, pH 5.0)/ethanol (20% v/v)/NaCl (0.3% w/v), NSAIDs could be determined at low microM levels without sample matrix removal. The detection limit was 0.096 microM for indoprofen, 0.110 microM for ketoprofen, 0.012 microM for naproxen, 0.023 microM for ibuprofen, 0.110 microM for fenoprofen, 0.140 microM for flurbiprofen, and 0.120 microM for suprofen. The method could be successfully applied to the simultaneous determination of NSAIDs in urine. The recoveries were better than 82% for all the analytes. The present method enables simple manipulation with UV detection for the determination of NSAIDs at low concentration levels in complex matrix samples.  相似文献   

19.
Dou YH  Bao N  Xu JJ  Chen HY 《Electrophoresis》2002,23(20):3558-3566
Separation and direct detection of amino acids, glucose and peptide in a 3.1 cm separation channel made of poly(dimethylsiloxane) (PDMS) with end-column amperometric detection at a copper microdisk electrode was developed. This system is the integration of a normal sized working electrode with electrochemical detection on a PDMS microfabricated device. The PDMS channels dynamically modified by 2-morpholinoethanesulfonic acid (MES) show less adsorption and more enhanced efficiency than that of unmodified ones when applied to separations of these biological molecules. The migration time is less than 100 s and the reproducibility of migration time is satisfactory with relative standard deviation (RSD) of 2.8% in 19 successive injections. The limits of detection of arginine (Arg), glucose, and methionine-glycine (Met-Gly) are estimated to be 2.0, 8.5, and 64.0 microM at S/N = 3, approximately 0.5-16.0 fmol, respectively. Variances influencing the separation efficiency and amperometric response, including injection, separation voltage, detection potential, or concentration of buffer and additive, are assessed and optimized.  相似文献   

20.
A rapid and sensitive method was developed for the analysis of amino acids by microchip electrophoresis with Hg-lamp excitation fluorescence detection. Fluorescein-isothiocyanate (FITC) was chosen to estimate the sensitivity of this system, and the detection limit (S/N = 3) with FITC was 1.7 nM, which showed that the system was sensitive as well as simple. Two derivatizing agents, FITC and ortho-phthalaldehyde (OPA) were employed to label amino acids and were compared in the same fluorescence detection system with an Hg lamp as the excitation source. The separation parameters were optimized in detail. Optimum separation of OPA-labeled amino acids was obtained in less than 200 s with 20 mM borate buffer (pH 9.0) containing 20% acetonitrile and 10 mM beta-cyclodextrin. Detection limits for amino acids (alanine (Ala), taurine (Tau), glycine (Gly), glutamic acid (Glu), and aspartic acid (Asp)) of 0.38-1.0 muM were achieved. The method was successfully applied to analysis of amino acids in human vascular endothelial cells (ECV-304). The average amount of amino acids in single ECV-304 cells is estimated to be 5.84 fmol for Ala, 2.78 fmol for Tau, 1.15 fmol for Gly, 3.10 fmol for Glu, and 1.30 fmol for Asp.  相似文献   