首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The ability to control cell-surface interactions in order to achieve binding of specific cell types is a major challenge for microfluidic immunoaffinity cell capture systems. In the majority of existing systems, the functionalized capture surface is constructed of solid materials, where flow stagnation at the solid-liquid interface is detrimental to the convection of cells to the surface. We study the use of ultra-high porosity (99%) nanoporous micro-posts in microfluidic channels for enhancing interception efficiency of particles in flow. We show using both modelling and experiment that nanoporous posts improve particle interception compared to solid posts through two distinct mechanisms: the increase of direct interception, and the reduction of near-surface hydrodynamic resistance. We provide initial validation that the improvement of interception efficiency also results in an increase in capture efficiency when comparing nanoporous vertically aligned carbon nanotube (VACNT) post arrays with solid PDMS post arrays of the same geometry. Using both bacteria (~1 μm) and cancer cell lines (~15 μm) as model systems, we found capture efficiency increases by 6-fold and 4-fold respectively. The combined model and experimental platform presents a new generation of nanoporous microfluidic devices for cell isolation.  相似文献   

2.
A one-step immunomagnetic separation technique was performed on a microfluidic platform for the isolation of specific cells from blood samples. The cell isolation and purification studies targeted T cells, as a model for low abundance cells (about 1:10,000 cells), with more dilute cells as the ultimate goal. T cells were successfully separated on-chip from human blood and from reconstituted blood samples. Quantitative polymerase chain reaction analysis of the captured cells was used to characterize the efficiency of T cell capture in a variety of flow path designs. Employing many (4-8), 50 microm deep narrow channels, with the same overall cross section as a single, 3 mm wide channel, was much more effective in structuring dense enough magnetic bead beds to trap cells in a flowing stream. The use of 8-multiple bifurcated flow paths increased capture efficiencies from approximately 20 up to 37%, when compared to a straight 8-way split design, indicating the value of ensuring uniform flow distribution into each channel in a flow manifold for effective cell capture. Sample flow rates of up to 3 microL min(-1) were evaluated in these capture beds.  相似文献   

3.
Liu YJ  Guo SS  Zhang ZL  Huang WH  Baigl D  Xie M  Chen Y  Pang DW 《Electrophoresis》2007,28(24):4713-4722
An integrated smart microfluidic device consisting of nickel micropillars, microvalves, and microchannels was developed for specific capture and sorting of cells. A regular hexagonal array of nickel micropillars was integrated on the bottom of a microchannel by standard photolithography, which can generate strong induced magnetic field gradients under an external magnetic field to efficiently trap superparamagnetic beads (SPMBs) in a flowing stream, forming a bed with sufficient magnetic beads as a capture zone. Fluids could be manipulated by programmed controlling the integrated air-pressure-actuated microvalves, based on which in situ bio-functionalization of SPMBs trapped in the capture zone was realized by covalent attachment of specific proteins directly to their surface on the integrated microfluidic device. In this case, only small volumes of protein solutions (62.5 nL in the capture zone; 375 nL in total volume needed to fill the device from inlet A to the intersection of outlet channels F and G) can meet the need for protein! The newly designed microfluidic device reduced greatly chemical and biological reagent consumption and simplified drastically tedious manual handling. Based on the specific interaction between wheat germ agglutinin (WGA) and N-acetylglucosamine on the cell membrane, A549 cancer cells were effectively captured and sorted on the microfluidic device. Capture efficiency ranged from 62 to 74%. The integrated microfluidic device provides a reliable technique for cell sorting.  相似文献   

4.
Yang Y  Kulangara K  Sia J  Wang L  Leong KW 《Lab on a chip》2011,11(9):1638-1646
Cells residing in a microenvironment interact with the extracellular matrix (ECM) and neighboring cells. The ECM built from biomacromolecules often includes nanotopography. Through the ECM, interstitial flows facilitate transport of nutrients and play an important role in tissue maintenance and pathobiology. To create a microenvironment that can incorporate both nanotopography and flow for studies of cell-matrix interactions, we fabricated microfluidic channels endowed with nanopatterns suitable for dynamic culture. Using polymer thin film technology, we developed a versatile stitching technique to generate a large area of nanopatterned surface and a simple microtransfer assembly technique to assemble polydimethylsiloxane-based microfluidics. The cellular study showed that both nanotopography and fluid shear stress played a significant role in adhesion, spreading, and migration of human mesenchymal stem cells. The orientation and deformation of cytoskeleton and nuclei were regulated through the interplay of these two cues. The nanostructured microfluidic platform provides a useful tool to promote the fundamental understanding of cell-matrix interactions and may be used to regulate the fate of stem cells.  相似文献   

5.
Kwon KW  Choi SS  Lee SH  Kim B  Lee SN  Park MC  Kim P  Hwang SY  Suh KY 《Lab on a chip》2007,7(11):1461-1468
A label-free microfluidic method for separation and enrichment of human breast cancer cells is presented using cell adhesion as a physical marker. To maximize the adhesion difference between normal epithelial and cancer cells, flat or nanostructured polymer surfaces (400 nm pillars, 400 nm perpendicular, or 400 nm parallel lines) were constructed on the bottom of polydimethylsiloxane (PDMS) microfluidic channels in a parallel fashion using a UV-assisted capillary moulding technique. The adhesion of human breast epithelial cells (MCF10A) and cancer cells (MCF7) on each channel was independently measured based on detachment assays where the adherent cells were counted with increasing flow rate after a pre-culture for a period of time (e.g., one, two, and four hours). It was found that MCF10A cells showed higher adhesion than MCF7 cells regardless of culture time and surface nanotopography at all flow rates, resulting in label-free separation and enrichment of cancer cells. For the cell types used in our study, an optimum separation was found for 2 hours pre-culture on the 400 nm perpendicular line pattern followed by flow-induced detachment at a flow rate of 200 microl min(-1). The fraction of MCF7 cells was increased from 0.36 +/- 0.04 to 0.83 +/- 0.04 under these optimized conditions.  相似文献   

6.
Circulating tumor cells are specifically referred as cells that detached from the primary tumor and are present in the bloodstream. They could be isolated from blood and used as representative biomarker for predicting cancer prognoses. Here, we developed a microfluidic chip with multiple curved channels, in which DNA fragments and antibody‐based enrichment are exploited to capture circulating tumor cells in blood sample. By introducing DNA fragments as long tentacles, the active antibody could be extended into the microchannel stereoscopically, which could greatly increase the chances of adhesion in a multidirectional way and improve the capture efficacy. Several pivotal factors for cell capturing were optimized to the best state. Compared to conventional chips for planar capturing, the capture efficiency of MCF‐7 cells was greatly increased from 37.17 to 85.10%. For the detection of MCF‐7‐containing artificial blood sample detection, the capture efficiency of tumor cells was about 74.19 ± 2.13%, which was obviously better than the result of flow cytometry (29.67 ± 4.02%). Captured cells were easily released from the surface of microfluidic chip with high cell viability, which could be investigated for the molecular analysis in the field of tumor diagnosis.  相似文献   

7.
The capture of circulating tumor cells (CTCs) from cancer patient blood enables early clinical assessment as well as genetic and pharmacological evaluation of cancer and metastasis. Although there have been many microfluidic immunocapture and electrokinetic techniques developed for isolating rare cancer cells, these techniques are often limited by a capture performance tradeoff between high efficiency and high purity. We present the characterization of shear‐dependent cancer cell capture in a novel hybrid DEP–immunocapture system consisting of interdigitated electrodes fabricated in a Hele‐Shaw flow cell that was functionalized with a monoclonal antibody, J591, which is highly specific to prostate‐specific membrane antigen expressing prostate cancer cells. We measured the positive and negative DEP response of a prostate cancer cell line, LNCaP, as a function of applied electric field frequency, and showed that DEP can control capture performance by promoting or preventing cell interactions with immunocapture surfaces, depending on the sign and magnitude of the applied DEP force, as well as on the local shear stress experienced by cells flowing in the device. This work demonstrates that DEP and immunocapture techniques can work synergistically to improve cell capture performance, and it will aid in the design of future hybrid DEP–immunocapture systems for high‐efficiency CTC capture with enhanced purity.  相似文献   

8.
Microfluidic devices have recently emerged as effective tools for cell separation compared to traditional techniques. These devices offer the advantages of small sample volumes, low cost, and high purity. Adhesion-based separation of cells from heterogeneous suspensions can be achieved by taking advantage of specific ligand-receptor interactions. The peptide sequences Arg-Glu-Asp-Val (REDV) and Val-Ala-Pro-Gly (VAPG) are known to bind preferentially to endothelial cells (ECs) and smooth muscle cells (SMCs), respectively. This article examines the roles of REDV and VAPG and fluid shear stress in achieving selective capture of ECs and SMCs in microfluidic devices. The adhesion of ECs in REDV-coated devices and SMCs in VAPG-coated devices increases significantly compared to that of the nontargeted cells with decreasing shear stress. Furthermore, the adhesion of these cells is shown to be independent of whether these cells flow through the devices as suspensions of only one cell type or as a heterogeneous suspension containing ECs, SMCs, and fibroblasts. Whereas the overall adhesion of cells in the devices is determined mainly by shear stress, the selectivity of adhesion depends on the type of peptide and on the device surface as well as on the shear stress.  相似文献   

9.
J Zhu  T Nguyen  R Pei  M Stojanovic  Q Lin 《Lab on a chip》2012,12(18):3504-3513
Isolation of cells from heterogeneous mixtures is critically important in both basic cell biology studies and clinical diagnostics. Cell isolation can be realized based on physical properties such as size, density and electrical properties. Alternatively, affinity binding of target cells by surface-immobilized ligands, such as antibodies, can be used to achieve specific cell isolation. Microfluidics technology has recently been used in conjunction with antibody-based affinity isolation methods to capture, purify and isolate cells with higher yield rates, better efficiencies and lower costs. However, a method that allows easy release and collection of live cells from affinity surfaces for subsequent analysis and detection has yet to be developed. This paper presents a microfluidic device that not only achieves specific affinity capture and enrichment, but also enables non-destructive, temperature-mediated release and retrieval of cells. Specific cell capture is achieved using surface-immobilized aptamers in a microchamber. Release of the captured cells is realized by a moderate temperature change, effected via integrated heaters and a temperature sensor, to reversibly disrupt the cell-aptamer interaction. Experimental results with CCRF-CEM cells have demonstrated that the device is capable of specific capture and temperature-mediated release of cells, that the released cells remain viable and that the aptamer-functionalized surface is regenerable.  相似文献   

10.
Interactions between ligands and cell surface receptors can be exploited to design adhesion-based microfluidic cell separation systems. When ligands are immobilized on the microfluidic channel surfaces, the resulting cell capture devices offer the typical advantages of small sample volumes and low cost associated with microfluidic systems, with the added benefit of not requiring complex fabrication schemes or extensive operational infrastructure. Cell-ligand interactions can range from highly specific to highly non-specific. This paper describes the design of an adhesion-based microfluidic separation system that takes advantage of both types of interactions. A 3-stage system of microfluidic devices coated with the tetrapeptides arg-glu-asp-val (REDV), val-ala-pro-gly (VAPG), and arg-gly-asp-ser (RGDS) is utilized to deplete a heterogeneous suspension containing endothelial cells, smooth muscle cells, and fibroblasts. The ligand-coated channels together with a large surface area allow effective depletion of all three cell types in a stagewise manner.  相似文献   

11.
This work presents a microfluidic device, which was patterned with (i) microstructures for hydrodynamic capture of single particles and cells, and (ii) multiplexing microelectrodes for selective release via negative dielectrophoretic (nDEP) forces and electrical impedance measurements of immobilized samples. Computational fluid dynamics (CFD) simulations were performed to investigate the fluidic profiles within the microchannels during the hydrodynamic capture of particles and evaluate the performance of single‐cell immobilization. Results showed uniform distributions of velocities and pressure differences across all eight trapping sites. The hydrodynamic net force and the nDEP force acting on a 6 μm sphere were calculated in a 3D model. Polystyrene beads with difference diameters (6, 8, and 10 μm) and budding yeast cells were employed to verify multiple functions of the microfluidic device, including reliable capture and selective nDEP‐release of particles or cells and sensitive electrical impedance measurements of immobilized samples. The size of immobilized beads and the number of captured yeast cells can be discriminated by analyzing impedance signals at 1 MHz. Results also demonstrated that yeast cells can be immobilized at single‐cell resolution by combining the hydrodynamic capture with impedance measurements and nDEP‐release of unwanted samples. Therefore, the microfluidic device integrated with multiplexing microelectrodes potentially offers a versatile, reliable, and precise platform for single‐cell analysis.  相似文献   

12.
A novel microfluidic device that can selectively and specifically isolate exceedingly small numbers of circulating tumor cells (CTCs) through a monoclonal antibody (mAB) mediated process by sampling large input volumes (>/=1 mL) of whole blood directly in short time periods (<37 min) was demonstrated. The CTCs were concentrated into small volumes (190 nL), and the number of cells captured was read without labeling using an integrated conductivity sensor following release from the capture surface. The microfluidic device contained a series (51) of high-aspect ratio microchannels (35 mum width x 150 mum depth) that were replicated in poly(methyl methacrylate), PMMA, from a metal mold master. The microchannel walls were covalently decorated with mABs directed against breast cancer cells overexpressing the epithelial cell adhesion molecule (EpCAM). This microfluidic device could accept inputs of whole blood, and its CTC capture efficiency was made highly quantitative (>97%) by designing capture channels with the appropriate widths and heights. The isolated CTCs were readily released from the mAB capturing surface using trypsin. The released CTCs were then enumerated on-device using a novel, label-free solution conductivity route capable of detecting single tumor cells traveling through the detection electrodes. The conductivity readout provided near 100% detection efficiency and exquisite specificity for CTCs due to scaling factors and the nonoptimal electrical properties of potential interferences (erythrocytes or leukocytes). The simplicity in manufacturing the device and its ease of operation make it attractive for clinical applications requiring one-time use operation.  相似文献   

13.
Cell-based microfluidic devices have attracted interest for a wide range of applications. While optical cell counting and flow cytometry-type devices have been reported extensively, sensitive and efficient non-optical methods to detect and quantify cells attached over large surface areas within microdevices are generally lacking. We describe an electrical method for counting cells based on the measurement of changes in conductivity of the surrounding medium due to ions released from surface-immobilized cells within a microfluidic channel. Immobilized cells are lysed using a low conductivity, hypotonic media and the resulting change in impedance is measured using surface patterned electrodes to detect and quantify the number of cells. We found that the bulk solution conductance increases linearly with the number of isolated cells contributing to solution ion concentration. The method of cell lysate impedance spectroscopy is sensitive enough to detect 20 cells microL(-1), and offers a simple and efficient method for detecting and enumerating cells within microfluidic devices for many applications including measurement of CD4 cell counts in HIV patients in resource-limited settings. To our knowledge, this is the most sensitive approach using non-optical setups to enumerate immobilized cells. The microfluidic device, capable of isolating specific cell types from a complex bio-fluidic and quantifying cell number, can serve as a single use cartridge for a hand-held instrument to provide simple, fast and affordable cell counting in point-of-care settings.  相似文献   

14.
Gurkan UA  Anand T  Tas H  Elkan D  Akay A  Keles HO  Demirci U 《Lab on a chip》2011,11(23):3979-3989
Selective capture of cells from bodily fluids in microchannels has broadly transformed medicine enabling circulating tumor cell isolation, rapid CD4(+) cell counting for HIV monitoring, and diagnosis of infectious diseases. Although cell capture methods have been demonstrated in microfluidic systems, the release of captured cells remains a significant challenge. Viable retrieval of captured label-free cells in microchannels will enable a new era in biological sciences by allowing cultivation and post-processing. The significant challenge in release comes from the fact that the cells adhere strongly to the microchannel surface, especially when immuno-based immobilization methods are used. Even though fluid shear and enzymes have been used to detach captured cells in microchannels, these methods are known to harm cells and affect cellular characteristics. This paper describes a new technology to release the selectively captured label-free cells in microchannels without the use of fluid shear or enzymes. We have successfully released the captured CD4(+) cells (3.6% of the mononuclear blood cells) from blood in microfluidic channels with high specificity (89% ± 8%), viability (94% ± 4%), and release efficiency (59% ± 4%). We have further validated our system by specifically capturing and controllably releasing the CD34(+) stem cells from whole blood, which were quantified to be 19 cells per million blood cells in the blood samples used in this study. Our results also indicated that both CD4(+) and CD34(+) cells released from the microchannels were healthy and amenable for in vitro culture. Manual flow based microfluidic method utilizes inexpensive, easy to fabricate microchannels allowing selective label-free cell capture and release in less than 10 minutes, which can also be used at the point-of-care. The presented technology can be used to isolate and purify a broad spectrum of cells from mixed populations offering widespread applications in applied biological sciences, such as tissue engineering, regenerative medicine, rare cell and stem cell isolation, proteomic/genomic research, and clonal/population analyses.  相似文献   

15.
Park MC  Hur JY  Kwon KW  Park SH  Suh KY 《Lab on a chip》2006,6(8):988-994
We present a simple cell docking method induced by receding meniscus to capture non-adherent yeast cells onto microwells inside a microfluidic channel. Microwells were fabricated either by capillary moulding of UV curable polyurethane acrylate (PUA) onto glass substrate or direct replica moulding of poly(dimethyl siloxane) (PDMS). A cell suspension of the budding yeast, Saccharomyces cerevisiae, was introduced into the microfluidic channel by surface tension driven capillary flow and a receding meniscus was subsequently generated by evaporation. As the meniscus progressed, one to multiple yeast cells were spontaneously captured onto microwells by lateral capillary force created at the bottom of the meniscus. Using this cell-based platform, we observed the response of yeast cells upon stimulation by a mating pheromone (alpha-factor) by monitoring the expression of green fluorescent protein (GFP) with time. It was observed that alpha-factor triggered the expression of GFP at 60 min after stimulation and the fluorescence intensity was sustained for an additional 60 min without changes.  相似文献   

16.
We present a method that allows patterning cells and shear flow conditions for endothelial cell based assays. This method is novel in combining (1) cell culture on the surface of a substrate both topographically and chemically patterned; (2) multi-shear flow assays after covering the cell substrate with a microfluidic cover plate containing microchannels of different channel widths, and (3) conventional immunostaining assays after removal of the cover plate. This method has the advantage of performing cell cultures and immunoassays in standard cell biology environments with open access, facilitating the formation of confluent cell layers and the observation of cell responses to shear-flow and drug stimulations. To obtain multi-shear stress conditions, a single channel with stepwise increasing channel widths was patterned on the surfaces of both the substrate and the microfluidic cover plate. As results, we observed excellent viability of endothelial cells in the whole range of applied shear stresses (0-25 dyn cm(-2)) and shear stress dependent cytoskeleton remoulding, activation of von Willebrand factor (vWF), and re-organisation of angiogenesis factors such as tetra peptide acetyl-Ser-Asp-Lys-Pro (AcSDKP) of endothelial cells. To validate this approach for drug analysis, we also studied drug effects under shear stress conditions. Our results indicate that the drug effect of combretastatin A-4, an anti-tumour vascular targeting drug, could be significantly enhanced under shear flow conditions.  相似文献   

17.
The ability to control the deposition and location of adherent and non-adherent cells within microfluidic devices is beneficial for the development of micro-scale bioanalytical tools and high-throughput screening systems. Here, we introduce a simple technique to fabricate poly(ethylene glycol)(PEG) microstructures within microfluidic channels that can be used to dock cells within pre-defined locations. Microstructures of various shapes were used to capture and shear-protect cells despite medium flow in the channel. Using this approach, PEG microwells were fabricated either with exposed or non-exposed substrates. Proteins and cells adhered within microwells with exposed substrates, while non-exposed substrates prevented protein and cell adhesion (although the cells were captured inside the features). Furthermore, immobilized cells remained viable and were stained for cell surface receptors by sequential flow of antibodies and secondary fluorescent probes. With its unique strengths in utility and control, this approach is potentially beneficial for the development of cell-based analytical devices and microreactors that enable the capture and real-time analysis of cells within microchannels, irrespective of cell anchorage properties.  相似文献   

18.
We describe the development, validation, and application of a novel PDMS-based microfluidic device for imaging leukocyte interaction with a biological substrate at defined shear force employing a parallel plate geometry that optimizes experimental throughput while decreasing reagent consumption. The device is vacuum bonded above a standard 6-well tissue culture plate that accommodates a monolayer of endothelial cells, thereby providing a channel to directly observe the kinetics of leukocyte adhesion under defined shear flow. Computational fluid dynamics (CFD) was applied to model the shear stress and the trajectory of leukocytes within the flow channels at a micron length scale. In order to test this model, neutrophil capture, rolling, and deceleration to arrest as a function of time and position was imaged in the transparent channels. Neutrophil recruitment to the substrate proved to be highly sensitive to disturbances in flow streamlines, which enhanced the rate of neutrophil-surface collisions at the entrance to the channels. Downstream from these disturbances, the relationship between receptor mediated deceleration of rolling neutrophils and dose response of stimulation by the chemokine IL-8 was found to provide a functional readout of integrin activation. This microfluidic technique allows detailed kinetic studies of cell adhesion and reveals neutrophil activation within seconds to chemotactic molecules at concentrations in the picoMolar range.  相似文献   

19.
In this study, we demonstrated a micro-fluidic system with multiple functions, including concentration of bacteria using dielectrophoresis (DEP) and selective capture using antibody recognition, resulting in a high capture efficiency of bacterial cells. The device consisted of an array of oxide covered interdigitated electrodes on a flat silicon substrate and a approximately 16 microm high and approximately 260 microm wide micro-channel within a PDMS cover. For selective capture of Listeria monocytogenes from the samples, the channel surface was functionalized with a biotinylated BSA-streptavidin-biotinylated monoclonal antibody sandwich structure. Positive DEP (at 20 V(pp) and 1 MHz) was used to concentrate bacterial cells from the fluid flow. DEP could collect approximately 90% of the cells in a continuous flow at a flow rate of 0.2 microl min(-1) into the micro-channel with concentration factors between 10(2)-10(3), in sample volumes of 5-20 microl. A high flow rate of 0.6 microl min(-1) reduced the DEP capture efficiency to approximately 65%. Positive DEP attracts cells to the edges of the electrodes where the field gradient is the highest. Cells concentrated by DEP were captured by the antibodies immobilized on the channel surface with efficiencies of 18 to 27% with bacterial cell numbers ranging from 10(1) to 10(3) cells. It was found that DEP operation in our experiments did not cause any irreversible damage to bacterial cells in terms of cell viability. In addition, increased antigen expression (antigens to C11E9 monoclonal antibody) on cell membranes was observed following the exposure to DEP.  相似文献   

20.
We show a straightforward, flexible synergistic approach that combines microfluidics, electrochemistry, and a general immobilization strategy to activate regions of a substrate selectively for the precise immobilization of ligands and cells in patterns for a variety of cell-based assays and cell migration and cell adhesion studies. We develop microfluidic microchips to control the delivery of electrolyte solution to select regions of an electroactive hydroquinone SAM. Once an electrical potential is applied to the substrate, only the hydroquinone exposed to electrolyte solution within the microfluidic channels oxidizes to the corresponding quinone. The quinone form can then react chemoselectively with oxyamine-tethered ligands to pattern the surface. Therefore, this microfluidic/electrochemistry strategy selectively activates the surface for ligand patterning that exactly matches the channel design of the microfluidic channel. We demonstrate the ease of this system by first quantitatively characterizing the electrochemical activation and immobilization of ligands on the surface. Second, we immobilize a fluorescent dye to show the fidelity of the methodology, and third, we show the immobilization of biospecific cell adhesive peptide ligands to pattern cells. This is the first report that combines microfluidics/electrochemistry and a general electroactive immobilization strategy to pattern ligands and cells. We believe that this strategy will be of broad utility for applications ranging from fundamental studies of cell behavior to patterning molecules on a variety of materials for molecular electronic devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号