首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe an electrochemiluminescence (ECL) immunoarray incorporated into a prototype microfluidic device for highly sensitive protein detection and apply this system to accurate, sensitive measurements of prostate-specific antigen (PSA) and interleukin-6 (IL-6) in serum. The microfluidic system employed three molded polydimethylsiloxane (PDMS) channels on a conductive pyrolytic graphite chip (2.5?×?2.5 cm) inserted into a machined chamber and interfaced with a pump, switching valve, and sample injector. Each of the three PDMS channels encompasses three 3 μL analytical wells. Capture-antibody-decorated single-wall carbon nanotube forests are fabricated in the bottom of the wells. The antigen is captured by these antibodies on the well bottoms. Then, a RuBPY-silica-secondary antibody (Ab2) label is injected to bind to antigen on the array, followed by injection of sacrificial reductant tripropylamine (TPrA) to produce ECL. For detection, the chip is placed into an open-top ECL measuring cell, and the channels are in contact with electrolyte in the chamber. Potential applied at 0.95 V versus Ag/AgCl oxidizes TPrA to produce ECL by redox cycling the RuBPY species in the particles, and ECL light is measured by a charge-coupled device camera. This approach achieved ultralow detection limits of 100 fg?mL?1 for PSA (9 zeptomole) and 10 fg?mL?1 (1 zeptomole) for IL-6 in calf serum, a 10–25-fold improvement of a similar non-microfluidic array. PSA and IL-6 in synthetic cancer patient serum samples were detected in 1.1 h and results correlated well with single-protein enzyme-linked immunosorbent assays.  相似文献   

2.
Present work demonstrates the fabrication of new and facile sandwich‐type electrochemical immunosensor based on palladium nanoparticles (PdNPs), polyaniline (PANI) and fullerene‐C60 nanocomposite film modified glassy carbon electrode (PdNP@PANI‐C60/GCE) for ultrasensitive detection of Prostate‐specific antigen (PSA) biomarker. PdNP@PANI‐C60 was electrochemically synthesized on GCE and used as an electroactive substrate. PdNP@PANI‐C60 was characterized by scanning electron microscopy (SEM), energy‐dispersive X‐ray spectroscopy (EDS), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Primary antibody anti‐PSA (Ab1) was covalently immobilized on PdNP@PANI‐C60/GCE using NHS/EDC linkers. In the presence of PSA antigen, horseradish peroxidase secondary antibody (HRP‐Ab2) was brought into the surface of the electrode, developing stable amplified signals of H2O2 reduction. Under the optimal conditions, a linear curve for determination of PSA at the proposed immunosensor was 1.6×10?4 ng.mL?1 to 38 ng.mL?1 with a limit of detection (LOD) of 1.95×10?5 ng.mL?1. The proposed immunosensor was successfully validated in serum and urine samples towards PSA detection with satisfactory and acceptable results.  相似文献   

3.
A rapid and ultrasensitive electrochemiluminescence (ECL) competitive immunoassay based on CdSe quantum dots (QDs) and the shorter chain as possible (cysteamine and glutaraldehyde) has been designed for the detection of salbutamol (SAL). Cysteamine and glutaraldehyde made coating antigen immobilize well on the gold electrode surface through the reaction between functional groups, which brought about the simplicity of the immunosensor to some extent. Transmission electron microscopy image, dynamic light scattering, photoluminescence, ultraviolet‐visible absorption and electrochemical impedance spectra were used to characterize the prepared CdSe QDs and the cysteamine/glutaraldehyde/Ovalbumin‐SAL/anti‐SAL‐QDs immunosensor. In the air‐saturated PBS buffer containing 0.1 M K2S2O8 and 0.1 M KCl (pH 9.0), a strong ECL emission of QDs can be observed which depended linearly on the logarithm of the salbutamol concentration with a wide range from 0.05 ng mL?1 to 100 ng mL?1, and a detection limit of 0.0056 ng mL?1. The sensitivity, repeatability, and specificity of the ECL immunosensor have been evaluated. The sensor has been applied to real samples with satisfactory results. This work will open new ways of detecting food additive residue based on QDs ECL in immunoassays.  相似文献   

4.
An amperometric carcinoembryonic antigen (CEA) immunosensor was fabricated based on Prussian blue (PB), nano-calcium carbonate (nano-CaCO3) and nano-gold modified glassy carbon electrode. First, PB as a mediator was deposited on glassy carbon electrode to obtain a negatively charged surface. Then, positive nano-CaCO3 was adsorbed on the PB modified electrode through electrostatic interaction. Subsequently, gold nanoparticles were deposited on the nano-CaCO3/PB modified electrode. The use of two kinds of nanomaterials (nano-CaCO3 and nano-gold) with good biocompatibility as immobilization matrixes not only provides a biocompatible surface for protein loading but also avoids the leaking of PB. The size of nano-CaCO3 was characterized by transmission electron microscopy (TEM). The factors influencing the performance of the immunosensor presented were studied in detail. Under the optimized conditions, cyclic voltammograms (CV) determination of CEA showed a specific response in two concentration ranges from 0.3 to 20 ng mL?1 and from 20 to 100 ng mL?1 with a detection limit of 0.1 ng mL?1 at a signal-to-noise ratio of 3. The immunosensor presented exhibited high selectivity, sensitivity and good stability.  相似文献   

5.
A novel sandwich-type electrochemical immunosensor for human immunoglobulin G (hIgG) was developed using Au/SiO2 nanoparticles (NPs) with adsorbed horseradish peroxidase-anti-hIgG as the secondary antibody layer. The signal readout is based on the amperometric response to the catalytic reduction of hydrogen peroxide at an AuNPs-polythionine modified glassy carbon electrode. Under optimized conditions, the linear range is from 0.1 to 200 ng·mL?1, with a detection limit of 0.035 ng·mL?1 (at an S/N of 3). The immunosensor exhibited a performance that is better than that based on Au/SiO2NPs-excluded secondary antibody.  相似文献   

6.
Novel luminescence‐functionalized metal–organic frameworks (MOFs) with superior electrogenerated chemiluminescence (ECL) properties were synthesized based on zinc ions as the central ions and tris(4,4′‐dicarboxylicacid‐2,2′‐bipyridyl)ruthenium(II) dichloride ([Ru(dcbpy)3]2+) as the ligands. For potential applications, the synthesized MOFs were used to fabricate a “signal‐on” ECL immunosensor for the detection of N‐terminal pro‐B‐type natriuretic peptide (NT‐proBNP). As expected, enhanced ECL signals were obtained through a simple fabrication strategy because luminescence‐functionalized MOFs not only effectively increased the loading of [Ru(dcbpy)3]2+, but also served as a loading platform in the ECL immunosensor. Furthermore, the proposed ECL immunosensor had a wide linear range from 5 pg mL?1 to 25 ng mL?1 and a relatively low detection limit of 1.67 pg mL?1 (signal/noise=3). The results indicated that luminescence‐functionalized MOFs provided a novel amplification strategy in the construction of ECL immunosensors and might have great prospects for application in bioanalysis.  相似文献   

7.
A approach was successfully employed for constructing a solid‐state electrochemiluminescence (ECL) immunosensor by layer‐by‐layer self‐assembly of multiwall carbon nanotubes (MWCNTs)‐Nafion composite film, Ru(bpy)32+/nano‐Pt aggregates (Ru‐PtNPs) and Pt nanoparticles (PtNPs). The influence of Pt nanoparticles on the ECL intensity was quantitatively evaluated by calculating the electroactive surface area of different electrodes with or without PtNPs to immobilize Ru(bpy)32+. The principle of ECL detection for target α‐fetoprotein antigen (AFP) was based on the increment of resistance after immunoreaction, which led to a decrease in ECL intensity. The linear response range was 0.01–10 ng mL?1 with the detection limit of 3.3 pg mL?1. The immunosensor exhibited advantages of simple preparation and operation, high sensitivity and good selectivity.  相似文献   

8.
《Analytical letters》2012,45(8):1241-1254
A novel electrochemical immunosensor was prepared for the detection of the hepatitis C virus non-structural 5A protein. A glassy carbon electrode was modified with an Au-MoO3/Chitosan nanocomposite that warranted good conductivity and biocompatibility. Mesoporous silica with a large specific surface served as a nanocarrier for horseradish peroxidase and the polyclonal antibody as the reporter probe. The immunosensor was characterized by scanning electron microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. Following the sandwich-type immunoreaction, horseradish peroxidase was efficiently captured on the surface of the electrode to catalyze the decomposition of hydrogen peroxide. The analytical signal was obtained as an amperometric i-t curve (chronoamperometry). The assay reported here had a wide detection range (1 ng mL?1 ?50 µg mL?1) and detection limit as low as 1 ng mL?1 of hepatitis C virus non-structural 5A protein. The electrochemical biosensor experiments showed excellent reproducibility, high selectivity, and outstanding stability for the determination of hepatitis C virus non-structural 5A protein, and it was successfully applied to the detection of the analyte in real serum samples.  相似文献   

9.
We report on the construction of a label-free electrochemical immunosensor for detecting the core antigen of the hepatitis C virus (HCV core antigen). A glassy carbon electrode (GCE) was modified with a nanocomposite made from gold nanoparticles, zirconia nanoparticles and chitosan, and prepared by in situ reduction. The zirconia nanoparticles were first dispersed in chitosan solution, and then AuNPs were prepared in situ on the ZrO2-chitosan composite. In parallel, a nanocomposite was synthesized from AuNPs, silica nanoparticles and chitosan, and conjugated to a secondary antibody. The properties of the resulting nanocomposites were investigated by UV-visible photometry and transmission electron microscopy, and the stepwise assembly process was characterized by means of cyclic voltammetry and electrochemical impedance spectroscopy. An sandwich type of immunosensor was developed which displays high sensitivity to the HCV core antigen in the concentration range between 2 and 512?ng?mL?1, with a detection limit of 0.17?ng?mL?1 (at S/N?=?3). This immunosensor provides an alternative approach towards the diagnosis of HCV.
Fig
A sandwich-type immunosensor was constructed for the detection of HCV core Ag. AuNPs/ZrO2-Chits nanocomposites were prepared by in situ reduction method. AuNPs/SiO2-Chits nanocomposite integrated with secondary antibody (Ab2) without labeled HRP. The immunosensor displayed high sensitivity to HCV core antigen with a detection limit of 0.17?ng?mL?1 (S/N?=?3).  相似文献   

10.
A highly sensitive amperometric immunosensor has been developed for the detection of carcinoembryonic antigen (CEA). It is based on (a) Prussian Blue nanoparticles coated with poly(diallyldimethylammonium chloride) (P-PB) and (b) double-layer gold nanocrystals. The sensor was obtained by first electrodepositing porous gold nanocrystals on the glassy carbon electrode (GCE), and then by modifying the electrode with the coated P-PB. Subsequently, colloidal gold nanoparticles (nano-Au) were adsorbed onto the GCE by electrostatic interactions between the negatively charged nano-Au and the positively charged P-PB to immobilize CEA antibodies. Finally, bovine serum albumin was employed to block possible remaining active sites and to prevent the non-specific adsorption on the nano-Au. This immunosensor was characterized by cyclic voltammetry and scanning electron microscopy. The working range was adjusted to two concentration ranges, viz. from 0.5 to 10 ng.mL?1, and from 10 to 120 ng.mL?1 of CEA, with a detection limit of 0.2 ng.mL?1 at three times the background noise.  相似文献   

11.
The sensitivity of on-line vapor generation atomic absorption spectrometry of mercury and selenium was improved by using a new atom trap technology. The inner wall of a T-shaped quartz tube was coated with nanometer SiO2 so increase the residence time of the analyte atoms in the light path. The linear range of the calibration plots thus was increased to a range from 5.0 to 150 ng mL?1 for mercury, and from 4.5 to 100 ng mL?1 for selenium. The detection limits are 0.9 ng mL?1 for Hg and 1.0 ng mL?1 for Se which is a 2-fold improvement. The technique was applied to the determination of Hg and Se in herbs and hair.  相似文献   

12.
A simple and inexpensive immunosensor is reported for the rapid determination of Staphylococcus aureus B-1266 that uses Fe3O4–SiO2–NH2 nanoparticles as the direct signal label. The electrochemical immunoassay procedure includes the incubation of bacteria with excess magnetite nanoparticles, the magnetic separation of the free nanoparticles, a labeled immunocomplex formation on the surface of a planar electrode, and the electrochemical response from the magnetite nanoparticles in the immunocomplex. The electrochemical immunosensor allows for the selective and accurate detection of S. aureus from 10 to 105?CFU?mL?1 with a relative standard deviation lower than 10%. The limit of detection was 8.7?CFU?mL?1.  相似文献   

13.
A dual-responsive sandwich-type immunosensor is described for the detection of interleukin 6 (IL-6) by combining electrochemiluminescent (ECL) and electrochemical (EC) detection based on the use of two kinds of TiO2 mesocrystal nanoarchitectures. A composite was prepared from TiO2 (anatase) mesocages (AMCs) and a carboxy-terminated ionic liquid (CTIL) and then placed on a glassy carbon electrode (GCE). In the next step, the ECL probe Ru(bpy)3(II) and antibody against IL-6 (Ab1) were immobilized on the GCE. Octahedral anatase TiO2 mesocrystals (OAMs) served as the matrix for immobilizing acid phosphatase (ACP) and secondary antibody (Ab2) labeled with horseradish peroxidase (HRP) to form a bioconjugate of type Ab2-HRP/ACP/OAMs. It was self-assembled on the GCE by immunobinding. 1-Naphthol, which is produced in-situ on the surface of the GCE due to the hydrolysis of added 1-naphthyl phosphate by ACP, is oxidized by HRP in the presence of added H2O2. This results in an electrochemical signal (typically measured at 0.4 V vs. Ag/AgCl) that increases linearly in the 10 fg·mL?1 to 90 ng·mL?1 IL-6 concentration range with a detection limit of 0.32 fg·mL?1. Secondly, the oxidation product of 1-naphthol quenches the ECL emission of Ru(bpy)32+. This leads to a decrease in ECL intensity which is linear in the 10 ag·mL?1 to 90 ng·mL?1 concentration range, with a detection limit of 3.5 ag·mL?1. The method exhibits satisfying selectivity and good reproducibility which demonstrates its potential in clinical testing and diagnosis.
Graphical abstract A dual-responsive sandwich-type immunosensor was fabricated for the detection of interleukin 6 by combining electrochemiluminescence and electrochemical detection based on the use of two kinds of TiO2 mesocrystal nanoarchitectures.
  相似文献   

14.
《Analytical letters》2012,45(13):2266-2280
A novel electrochemical immunosensor was developed for the determination of prostate-specific antigen based on immobilization of appropriate antibodies on gold nanoparticles and a poly-(2,6-pyridinediamine) modified electrode. The nanocomposite of ferrocene monocarboxylic acid hybridized graphene oxide was prepared by a π-π stacking interaction and was used as the electrochemical probe. A sandwich-type complex immunoassay was applied with polyclonal prostate-specific antigen antibodies labeled with the nanocomposite of ferrocene monocarboxylic acid hybridized graphene oxide. In order to improve the sensitivity, a potentiostatic method was used to reduce graphene oxide. Cyclic voltammetry and differential pulse voltammetry were employed to characterize the assembly process and the performance of the immunosensor. Under optimal conditions, the peak current of the immunosensor increased with concentration, showing a linear relationship between the peak current and the logarithm of the prostate-specific antigen concentrations in a wide range of 2.0 pg mL?1 to 10.0 ng mL?1 with a low detection limit of 0.5 pg mL?1. The immunosensor was used for the determination of prostate-specific antigen in serum.  相似文献   

15.
A simple and sensitive electrochemical immunosensor for a one-step immunoassay for alpha-fetoprotein (AFP) was designed using silver nanoparticles and double-stranded DNA as matrices. The detection was based on the change in the electron transfer resistance before and after the antigen-antibody reaction by using electrochemical impedance spectroscopy. Under optimal conditions, the resistance shift of the immunosensor is proportional to the AFP concentration in the range 3.5 –360 ng·mL?1 with a detection limit of 1.5 ng·mL?1 (at 3σ). The immunosensor exhibits high sensitivity, good reproducibility and stability. Results obtained for clinical serum samples by the immunosensor are in accordance with those determined by spectrophotometric enzyme-linked immunosorbent assays.  相似文献   

16.
An immunosensor has been fabricated for direct amperometric determination of carcinoembryonic antigen. It is based on a biocompatible composite film composed of porous chitosan (pChit) and gold nanoparticles (GNPs). Firstly, a pChit film was formed on a glassy carbon electrode by means of electrodeposition. Then, thionine as a redox probe was immobilized on the pChit film modified electrode using glutaraldehyde as a cross-linker. Finally, GNPs were adsorbed on the electrode surface to assemble carcinoembryonic antibody (anti-CEA). The surface morphology of the pChit films was studied by means of a scanning electron microscope. The immunosensor was further characterized by cyclic voltammetry and electrochemical impedance spectroscopy. The electrochemical behaviors and factors influencing the performance of the resulting immunosensors were studied in detail. Results showed that the pChit films can enhance the surface coverage of antibodies and improve the sensitivity of the immunosensor. Under optimal conditions, the immunosensor was highly sensitive to CEA with a detection limit of 0.08 ng·mL?1 at three times the background noise and linear ranges of 0.2~10.0 ng·mL?1 and 10.0~160 ng·mL?1. Moreover, the immunosensor exhibited high selectivity, good reproducibility and stability.  相似文献   

17.
We report on a sensitive electrochemical immunoassay for the prostate specific antigen (PSA). An immunoelectrode was fabricated by coating a glassy carbon electrode with multiwalled carbon nanotubes, poly(dimethyldiallylammonium chloride), CeO2 and PSA antibody (in this order) using the layer-by-layer method. The immunosensor is then placed in a sample solution containing PSA and o-phenylenediamine (OPD). It is found that the CeO2 nanoparticles facilitate the electrochemical oxidation of OPD, and this produces a signal for electrochemical detection of PSA that depends on the concentration of PSA. There is a linear relationship between the decrease in current and the concentration of PSA in the 0.01 to 1,000 pg mL?1 concentration range, and the detection limit is 4 fg mL?1. The assay was successfully applied to the detection of PSA in serum samples. This new differential pulse voltammetric immunoassay is sensitive and acceptably precise, and the fabrication of the electrode is well reproducible. Figure
A novel electrochemical immunoassay for prostate specific antigen (PSA) was developed. Ceria (CeO2) mesoporous nanospheres facilitated the electrochemical oxidation of o-phenylenediamine (OPD). The developed immunoassay has high sensitivity and can be successfully applied for the detection of PSA in serum samples  相似文献   

18.
Wang  Yanying  Qu  Ying  Liu  Guishen  Hou  Xiaodong  Huang  Yina  Wu  Wangze  Wu  Kangbing  Li  Chunya 《Mikrochimica acta》2015,182(11):2061-2067

High molecular-weight silk peptide (SP) was used to functionalize the surface of nanosheets of reduced graphene oxide (rGO). The SP-rGO nanocomposite was then mixed with mouse anti-human prostate specific antigen monoclonal antibody (anti-PSA) and coated onto a glassy carbon electrode to fabricate an immunosensor. By using the hexacyanoferrate redox system as electroactive probe, the immunosensor was characterized by voltammetry and electrochemical impedance spectroscopy. The peak current, measured at the potential of 0.24 V (vs. SCE), is distinctly reduced after binding prostate specific antigen (PSA). Response (measured by differential pulse voltammetry) is linearly related to PSA concentration in the range from 0.1 to 5.0 ng · mL−1 and from 5.0 to 80.0 ng∙mL−1, and the detection limit is 53 pg∙mL−1 (at an SNR of 3). The immunosensor was successfully applied to the determination of PSA in clinical serum samples, and the results were found to agree well with those obtained with an enzyme-linked immunosorbent assay.

Nanosheets of reduced graphene oxide were functionalized with silk peptide and used to immobilize anti-PSA to fabricate an immunosensor for PSA.

  相似文献   

19.
Magnetic electrochemiluminescent Fe3O4/CdSe–CdS nanoparticle/polyelectrolyte nanostructures have been synthesized and used to fabricate an electrochemiluminescence (ECL) immunosensor for the detection of carcinoembryonic antigen (CEA). CEA is a protein used as a biomarker for several cancers; particularly, to monitor response to treatment in colon and rectal cancer patients. The nanocomposites can be easily separated and firmly attached to an electrode owing to their excellent magnetic properties. This represents a promising advantage for bioassay applications. More importantly, the nanostructures exhibit intense and stable ECL emissions in neutral solution, which makes them ideal for ECL immunosensing. The 3‐aminopropyltriethoxysilane (APS) polyelectrolyte shell on the nanostructure surface not only enhances the intensity and stability of the ECL signal, but also acts as a crosslinker for immunosensor fabrication. A CEA antibody immobilized onto a nanocomposite/APS/electrode with gold nanoparticles comprises the ECL immunosensor. The principle of ECL detection for CEA is based on a change in steric hindrance after immunoreaction, which leads to a decrease in ECL intensity. A wide detection range (0.064 pg ml?1–10 ng ml?1) and low detection limit (0.032 pg ml?1) are achieved. The immunosensor is highly sensitive and selective, and exhibits excellent stability and good reproducibility. It thus has great potential for clinical protein detection. In particular, this approach uses a novel class of bifunctional nanocomposites that display both intense ECL and excellent magnetism, which renders them suitable for a large range of bioassay applications.  相似文献   

20.
Biofunctionalizing a simple and disposable graphene oxide-modified screen-printed carbon electrode with anti-interleukin-15 antibodies has been successfully demonstrated for the first time for the label-free electrochemical detection of interleukin-15, a biomarker of early HIV infection. To improve the electrochemical reactivity and introduce carboxylic groups on the surface of screen-printed carbon electrode, high-quality graphene oxide was used for the modification of screen-printed carbon electrode. With simple modification of the screen-printed carbon electrode, the device exhibited satisfactory sensitivity, selectivity, stability, reproducibility, and regenerability. The immunosensor provided a detection limit of 3.51?ng?mL?1 and a sensitivity of 0.5655?µA cm?2?mL?ng?1. The simply constructed immunosensor thus rendered promising device for immunoreactions on the surface of the electrode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号