首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Polyclonal antisera to -amanitin were generated in sheep and used to construct a competitive ELISA for measurement of the toxin in human serum and urine. The assay had a detection limit of about 80 pg mL–1, a dynamic range of 80–2,000 pg mL–1, a cross reactivity of 22% with -amanitin, and no cross reactivities with cyclic peptides from algal sources. Assay responses in buffer, serum, and urine were remarkably similar. Coupling of the toxin to carrier proteins was carried out by previously unreported methods. The key step that allowed the construction of the highly sensitive assay was the introduction of a novel heterologous hapten derivative made of -amanitin-cyanuric chloride derivative. The new derivative overcame the problems of bridge binding that was, in this case, particularly serious with the homologous hapten derivative. The study demonstrated that the developed antiserum and ELISA procedure can be used to detect -amanitin and related toxins from Amanita phalloides in human serum and urine samples from suspected poison cases and enable early treatment to be administered.  相似文献   

2.
A rapid and sensitive method for the analysis of three catecholamines by capillary electrophoresis(CE)with directchemiluminescence(CL)detection is described.The detection limits(S/N=3)were 1.3*10-8g/mL for isoprenaline,1.0*10-8g/mL for epinephrine and 2.8*10-8g/mL for dopamine.The proposed method was successfully applied to theanalysis of catecholamines in urine samples of cigarette smokers and nonsmokers.The results showed that there is a close relationbetween the release of dopamine in human body fluids and cigarette smoking/nonsmoking.  相似文献   

3.
Ganglioside–liposome immunoassay for the detection of botulinum toxin   总被引:3,自引:0,他引:3  
A rapid and highly sensitive receptor immunoassay for botulinum toxin (BT) has been developed using ganglioside-incorporated liposomes. Botulism outbreaks are relatively rare, but their results can be very severe, usually leading to death from respiratory failure. To exert their toxicity, the biological toxins must first bind to receptors on the cell surface, and the trisialoganglioside GT1b has been identified as the cell receptor for BT. Therefore, in this study, GT1b was used to prepare the ganglioside–liposomes by spontaneous insertion into the phospholipid bilayer. In a sandwich-based, hybrid receptor immunoassay, BT is detected as a colored band on a nitrocellulose membrane strip, where BT bound to the GT1b-liposomes are captured by anti-BT antibodies immobilized in a band across the strip. The intensity of the colored band can be visually estimated, or measured by densitometry using computer software. The limit of detection (LOD) for BT in the lateral-flow assay system was 15 pg mL–1, which is comparable to the limits of detection achieved with the most sensitive assays previously reported. However, this rapid assay can be completed in less than 20 min. These results demonstrate that the sandwich assay using GT1b-liposomes for detection of BT is rapid and very sensitive, suggesting the possibility for detecting BT in field screening, simply and reliably, without the need for complex instrumentation.  相似文献   

4.
Enzyme immunoassays with optical detection are amongst the most widely used bioanalytical tools. We defined seven parameters for the quality assessment of immunoassays that were addressed in a systematic study of direct and indirect immunoassays, using the enzymes horseradish peroxidase (HRP) and alkaline phosphatase (AP), the chromogenic substrates 3,3′,5,5′-tetramethylbenzidine (TMB) and para-nitrophenyl phosphate, and the fluorescent substrates 3-(4-hydroxyphenyl)propionic acid and 4-methylumbelliferyl phosphate. The same monoclonal antibody against caffeine was used throughout the study. The four quality parameters regarding the standard curve were the test midpoint (sensitivity), the measurement range, the relative dynamic range of the signal, and the goodness of fit of the adjusted four-parameter logistic function. All HRP immunoassays showed a higher sensitivity compared to the AP assays. On the basis of all four criteria, it was established that the direct assay format is superior to the indirect format, the immunoassay using HRP TMB fulfilling all requirements best. In a second step, caffeine concentrations in 24 beverage and cosmetics samples were determined and three more quality parameters were assessed with this application. The direct HRP TMB assay showed one of the best intra- and inter-plate precisions and the best accuracy, defined by the correlation of results with those from the chosen reference method liquid chromatography tandem mass spectrometry (LC-MS/MS). Considering all criteria, HRP TMB seems to be the enzyme substrate system of choice preferably used in the direct assay format.
Figure
Overview on the different enzyme immunoassay formats compared  相似文献   

5.
A liquid chromatography–tandem mass spectrometry method for the simultaneous quantification of buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine glucuronide (BUP-Gluc), and norbuprenorphine glucuronide (NBUP-Gluc) in human urine was developed and fully validated. Extensive endogenous and exogenous interferences were evaluated and limits of quantification were identified empirically. Analytical ranges were 5–1,000 ng/mL for BUP and BUP-Gluc and 25–1,000 ng/mL for NBUP and NBUP-Gluc. Intra-assay and interassay imprecision were less than 17% and recovery was 93–116%. Analytes were stable at room temperature, at 4 °C, and for three freeze–thaw cycles. This accurate and precise assay has sufficient sensitivity and specificity for urine analysis of specimens collected from individuals treated with BUP for opioid dependence.  相似文献   

6.
A sensitive, specific and selective multianalyte GC–MS/MS method has been developed for the determination of 11 anabolic hormones in bovine urine. After adjusting the urine pH to 4.8, the samples were spiked with deuterated internal standards and submitted to enzymatic hydrolysis with β-glucuronidase/arylsulfatase. Hormones were eluted with methanol through a C18 solid phase cartridge and submitted to a liquid–liquid extraction. Analytes were derivatized by adding N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane and GC–MS data were obtained in the positive electron impact tandem mass mode. Under these conditions, no matrix effects were observed and limit of detection values were in the range of 0.005 ng/mL (diethylstilbestrol) to 0.38 ng/mL (17α-methyltestosterone and 17α-ethynylestradiol). Recoveries from 81% (α-zeranol) to 149% (17α-methyltestosterone) were found under the selected conditions. These results were better than those found using heptafluorobutyric anhydride (HFBA) as derivative reagent and those measured in full scan and selective ion monitoring modes.  相似文献   

7.
β-Lactam antibiotics, including penicillins and cephalosporins, are commonly used in veterinary medicine. Illegal use and abuse of β-lactams could cause allergy and selected bacterial resistance. BlaR-CTD, the carboxy-terminal of penicillin-recognizing protein BlaR from Bacillus licheniformis ATCC 14580, was utilized in this study to develop a receptor-based ELISA for detection and determination of β-lactam antibiotics in milk, beef, and chicken. This assay was based on directly competitive inhibition of binding of horseradish peroxidase-labeled ampicillin to the immobilized BlaR-CTD by β-lactams. The assay was developed as screening test with the option as semiquantitative assay, when the identity of a single type of residual β-lactam was known. The IC50 values of 15 β-lactam antibiotics, including benzylpenicillin, ampicillin, amoxicillin, dicloxacillin, oxacillin, nafcillin, cefapirin, cefoperazone, cefalotin, cefazolin, cefquinome, ceftriaxone, cefotaxime, cefalexin, ceftiofur and its metabolite desfuroylceftiofur were evaluated and ranged from 0.18 to 170.81 μg L?1. Simple sample extraction method was carried out with only phosphate-buffered saline, and the recoveries of selected β-lactam antibiotics in milk, beef, and chicken were in the range of 53.27 to 128.29 %, most ranging from 60 to 120 %. The inter-assay variability was below 30 %. Limits of detection in milk, beef, and chicken muscles with cefquinome matrix calibration were 2.10, 30.68, and 31.13 μg kg?1, respectively. This study firstly established a rapid, simple, and accurate method for simultaneous detection of 15 β-lactams in edible tissues, among which 11 β-lactams controlled by European Union could be detected below maximum residue limits.
Figure
The receptor-based ELISA for blank sample (negative samples, left) and sample containing β-lactam antibiotics (positive samples, right)  相似文献   

8.
SiO2 nanosheets (SNS) have been prepared by a chemical method using montmorillonite as raw material and were characterized by scanning electron microscopy and X-ray diffraction. SiO2 nanosheet–Nafion nanocomposites with excellent conductivity, catalytic activity, and biocompatibility provided an extremely hydrophilic surface for biomolecule adhesion. Chitosan was used as a cross-linker to immobilize acetylcholinesterase (AChE), and Nafion was used as a protective membrane to efficiently improve the stability of the AChE biosensor. The AChE biosensor showed favorable affinity for acetylthiocholine chloride and catalyzed the hydrolysis of acetylthiocholine chloride with an apparent Michaelis–Menten constant of 134 μM to form thiocholine, which was then oxidized to produce a detectable and fast response. Based on the inhibition by pesticides of the enzymatic activity of AChE, detection of the amperometric response from thiocholine on the biosensor is a simple and effective way to biomonitor exposure to pesticides. Under optimum conditions, the biosensor detected methyl parathion, chlorpyrifos, and carbofuran at concentrations ranging from 1.0?×?10?12 to 1?×?10?10?M and from 1.0?×?10?10 to 1?×?10?8?M. The detection limits for methyl parathion, chlorpyrifos, and carbofuran were 5?×?10?13?M. The biosensor developed exhibited good sensitivity, stability, reproducibility, and low cost, thus providing a new promising tool for analysis of enzyme inhibitors.
Figure
Performances and detection pesticides of a SiO2 nanosheet biosensor  相似文献   

9.
10.
Chemiluminescence immunoassay(CLⅠA) has always been a great challenge in detecting cardiac troponin Ⅰ(c Tn Ⅰ) in whole blood samples without centrifugation because of the interference of red blood cells and low sensitivity. Ⅰn this study, the antigens and erythrocytes in the blood were captured by the antibodies immobilized on the magnetic particles, recognized by another biotinconjugated c Tn Ⅰ antibody and detected by streptavidin/acridine aster-conjugated polychloromethylstyrene microspheres(...  相似文献   

11.
Summary A procedure is described for simultaneous determination of estriol, estrone and 17-estradiol in human urine. After acid hydrolysis of the sulphate conjugates, the estrogens were extracted into diethyl ether. The ether extracts were concentrated and applied directly to an HPLC column. Using a 25 cm C-18 column and acetonitrile-water modified by the addition of -cyclodextrin as mobile phase, the separation of estriol, estradiol and estrone was achieved within 20 minutes. The extraction of estrogens from the biological matrix is excellent. Estrogens were detected using a UV-detector (280 nm) or a spectrofluorimetric detector (exc=280nm, em=312 nm). The latter detection system has been used for the determination of estrogens in the urine of non-pregnant women. The procedure is simple and can be used in clinical practice.  相似文献   

12.
The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of “Experimental design”. The optimal conditions were obtained by performing derivatization with 100 μL of propyl chloroformate and 100 μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of “Experimental design” and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45 min at room temperature, desorption temperature at 300 °C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800 μg L−1 were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23 μg L−1 for DA, 5-HT and NE, respectively).  相似文献   

13.
This paper describes a liquid chromatographic/tandem mass spectrometric (LC/MS–MS) method specifically designed for the screening of synthetic glucocorticosteroids in human urine. The method is designed to recognize a common mass spectral fragment formed from the particular portion of the molecular structure that is common to all synthetic glucocorticosteroids and that is fundamental to their pharmacological activity. As such, the method is also suitable for detecting unknown substances, provided they contain the portion of the molecular structure selected as the analytical target. The effectiveness of this approach was evaluated on seventeen synthetic glucocorticosteroids. Urine samples, including blank urines spiked with one or more synthetic glucocorticosteroids, were treated according to a standard procedure (enzymatic hydrolysis, liquid/liquid extraction and evaporation to dryness) and analyzed using LC/MS-MS with electrospray ionization (ESI). MS–MS acquisition was carried out in a precursor ion scan, and the results were compared with those obtained by a previously developed reference technique based on acquisition in the multiple reaction monitoring (MRM) mode. All of the glucocorticosteroids considered in this study are clearly detectable in urine, with a limit of detection in the concentration range 5–20 ng/mL, depending on the glucocorticosteroid structure. The proposed method is therefore suitable for the detection of glucocorticosteroids in urine samples taken for “in competition” sport anti-doping control tests, matching the requirements of the World Anti-Doping Agency (WADA) for accredited anti-doping laboratories. Figure Structures of the synthetic glucocorticoids considered in this study  相似文献   

14.
In this work, a simple isocratic reversed-phase HPLC method for determination of alpha-tocopherol in human erythrocytes has been developed and validated. After separation of plasma the erythrocytes were washed three times with 0.9% sodium chloride containing 0.01% butylated hydroxytoluene (BHT) as antioxidant and then were diluted 1:1 (v/v) with the same solution. In the liquid-liquid extraction (LLE) procedure, 2500 microL of n-hexane was added to 500 microL of erythrocytes. After 2 min this mixture was deproteinized by addition of cool ethanol (500 microL, 5 min) denatured with 5% methanol containing alpha-tocopherol acetate (20 micromol L(-1)), as internal standard, and then extracted for 5 min by vortex mixing. After centrifugation (10 min, 1600xg) an aliquot (2000 microL) of the clean extract was separated and evaporated under nitrogen. The residue was dissolved in 400 microL methanol and analysed by reversed-phase HPLC on a 4.6 mmx150 mm, 5 microm Pecosphere C18 column; the mobile phase was 100% methanol, flow rate 1.2 mL min(-1). The volume injected was 100 microL and detection was by diode-array detector at a wavelength of 295 nm. The extraction recovery of alpha-tocopherol from human erythrocytes was 100.0+/-2.0%. The detection limit was 0.1 micromol L(-1) and a linear calibration plot was obtained in the concentration range 0.5-20.0 micromol L(-1). Within determination precision was 5.2% RSD (n=10), between determination precision was 6.1% RSD (n=10). The method was applied successfully in a clinical study of patients with acute pancreatitis and for determination of the reference values in the healthy Czech population.  相似文献   

15.
Water-soluble 2-hydroxypropyl-β-cyclodextrin (Hp-β-CyD), a cyclic and nonreducing oligosaccharide was used to enclose a hydrophobic guest molecule 1,1′-dimethylferrocene (DMF) to form a water-soluble yellow complex. At high concentrations (300 mM), Hp-β-CyD enclosed up to 100 mM DMF. The yellow complex was electrochemically oxidized (platinum vs Ag/AgCl poised at +450 mV) to form a blue dye, 1,1′-dimethylferricinium (DMF+). This is a one-electron transfer process and the ferricinium cation formed exhibited an absorption peak at 650 nm. The concentrated DMF+ was stable for at least 4 mo at 4°C and insensitive to a wide pH variation (pH 2–11). Application of the novel DMF+ complex as a colorimetric dye for the determination of uric acid in urine was successfully demonstrated. The reaction between the dye and uric acid is almost instantaneous and decrease in absorbance caused by the reduction of 1,1′-dimethylferricinium to 1,1′-dimethylferrocene can be followed at 650 nm. The results obtained agreed well with those of the reference reversed-phase HPLC method.  相似文献   

16.
A highly sensitive electrochemiluminescence-polymerase chain reaction (ECL-PCR) method for K-ras point mutation detection is developed. Briefly, K-ras oncogene was amplified by a Ru(bpy)32 (TBR)-labeled forward and a biotin-labeled reverse primer, and followed by digestion with MvaI restriction enzyme, which only cut the wild-type amplicon containing its cutting site. The digested product was then adsorbed to the streptavidin-coated microbead through the biotin label and detected by ECL assay. The experiment results showed that the different genotypes can be clearly discriminated by ECL-PCR method. It is useful in point mutation detection, due to its sensitivity, safety, and simplicity.  相似文献   

17.
A method is proposed for determining nefrotsizin (luteolin 7-O--D-glucopyranoside) in the radical leaves ofFerula varia. which is based on the extraction of nefrotsizin from the raw material, its identification by TLC, elution from the plate, and spectrophotometric determination.Institute of Chemistry of Plant Substances, Uzbekistan Republic of Sciences, Tashkent. Translated from Khimiya Prirodnykh Soedinenii, No. 2, pp. 217–220, March–April, 1993.  相似文献   

18.
A sensitive and selective liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed to determine pantoprazole sodium (PNT) in human urine. After solid-phase extraction with SPE cartridge, the urine sample was analysed on a C18 column (symmetry 3.5 μm; 75 mm × 4.6 mm i.d) interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile–water (90:10, v/v). The method was linear over a concentration range of 1–100 ng mL?1. The lower limit of quantitation was 1 ng mL?1. The intra-day and inter-day relative standard deviation across three validation runs over the entire concentration range was <10.5%. The accuracy determined at three concentrations (8.0, 50.0 and 85.0 ng mL?1 PNT) was within ±1.25% in terms of relative errors.  相似文献   

19.
Cardiac glycosides digoxin and digitoxin are used in therapy for the treatment of congestive heart failure. Moreover, these compounds can be responsible for intoxication cases caused by fortuitous ingestion of leaves of Digitalis. Due to the narrow therapeutic range of these drugs, therapeutic drug monitoring is recommended in the clinical practice. In this context, immunoassays-based methods are generally employed but digoxin- and digitoxin-like compounds can interfere with the analysis. The aim of this study was to develop and validate an original UPLC–MS/MS method for the determination of digoxin and digitoxin in plasma. The method shows adequate sensitivity and selectivity with acceptable matrix effects and very good linearity, accuracy, precision, and recovery. A simple liquid–liquid extraction procedure was used for sample clean-up. The method was applied for the analysis of n = 220 plasma samples collected in two different clinical chemistry laboratories and previously tested by the same immunoassay. The statistical comparison showed a relevant negative bias of the UPLC–MS/MS method versus the immunoassay. These results are consistent with an immunoassay overestimation of digoxin plasmatic levels due to cross-reaction events with endogenous digoxin-like substances.  相似文献   

20.
A simple method using solid-phase extraction (SPE) and ultra high-performance liquid chromatography (UHPLC) for the simultaneous determination of β-blockers, isoflavones, and flavonoids in human urine is developed. A statistical central composite design and response surface analysis is used to optimize the separation of the analytes. These multivariate procedures are efficient in determining the optimal separation condition using resolutions and retention time as responses. A gradient elution using a mobile phase consisting of 0.05% trifluoroacetic acid in water and acetonitrile is applied on a Hypersil GOLD column within a short analysis time of 4.5 min. UV detection was used to monitor the analytes. The suggested method was linear in a concentration range from 0.04-20.00 μg/mL, depending on the compound. The limits of detection ranged from 8.9 to 66.2 ng/mL. The precision was lower than 2.74%, and the accuracy was between 0.01-3.65%. The Oasis HLB column, with the highest recoveries, is selected for the pre-concentration step. This present paper reports, for the first time, a method for the simultaneous determination of β-blockers, isoflavones, and flavonoids in human urine samples. Furthermore, the developed method can also be applied to the routine determination of examined compounds concentrations in human urine.  相似文献   