1.
A method for isotope ratio analysis of water samples is described comprising an on-line high-temperature reduction technique in a helium carrier gas. Using a gas-tight syringe, injection of 0.5 to 1 microL sample is made through a heated septum into a glassy carbon reactor at temperatures in excess of 1300 degrees C. More than 150 injections can be made per day and both isotope ratios of interest, delta2H and delta18O, can be measured with the same setup. The technique has the capability to transfer high-precision stable isotope ratio analysis of water samples from a specialized to a routine laboratory task compatible with other common techniques (automated injection for GC, LC, etc.). Experiments with an emphasis on the reactor design were made in two different laboratories using two different commercially available high-temperature elemental analyser (EA) systems.In the Jena TC/EA unit, sample-to-sample memory (single injection) has been reduced to approximately 1% and high precision of about 0.1 per thousand for delta18O and < 1 per thousand for delta2H has been achieved by a redesign of the glassy carbon reactor and by redirecting the gas flow of the commercial TC/EA unit. With the modified reactor, the contact of water vapour with surfaces other than glassy carbon is avoided completely. The carrier gas is introduced at the bottom of the reactor thereby flushing the outer tube compartment of the tube-in-tube assembly before entering the active heart of the reactor.With the Leipzig high-temperature reactor (HTP) similar precision was obtained with a minor modification (electropolishing) of the injector metal sleeve. With this system, the temperature dependence of the reaction has been studied between 1100 and 1450 degrees C. Complete yield and constant isotope ratio information has been observed only for temperatures above 1325 degrees C. For temperatures above 1300 degrees C the reactor produces an increasing amount of CO background from reaction of glass carbon with the ceramic tube. This limits the usable temperature to a maximum of 1450 degrees C. Relevant gas permeation through the Al2O3 walls has not been detected up to 1600 degrees C.  相似文献   

2.
A low dead volume oxygen scrubbing system was introduced in a commercially available liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) interface to enhance the analytical capability of the system. In the LC/IRMS interface carbon from organic samples is converted into CO(2) inside the mobile phase by wet chemical oxidation using peroxodisulfate (Na(2)S(2)O(8)). After passing the hot reaction zone, surplus oxygen (O(2)) remains dissolved in the liquid phase. Both CO(2) and O(2) diffuse through a transfer membrane into the helium carrier and are transferred to the mass spectrometer. The presence of O(2) in the ion source may have detrimental effects on measurement accuracy and precision as well as on filament lifetime. As a remedy, a new on-line O(2)-removing device has been incorporated into the system.The new O(2) scrubber consists of two parallel hot copper reduction reactors (0.8 mm i.d., active length 120 mm) and a switch-over valve between them. One reactor is regenerated using He/H(2) while the other is actively scavenging O(2) from the gas stream. The capacity of each reduction reactor, expressed as usage time, is between 40 and 50 min. This is sufficient for a single LC run for sugars and organic acids. A further increase of the reduction capacity is accompanied by a peak broadening of about 100%. After switching to a freshly reduced reactor the oxygen background and the delta(13)C values of the reference gas need up to 500 s to stabilize. For repeated injections the delta(13)C values of sucrose remain constant (+/-0.1 per thousand) for about 3000 s. The long-term stability for measurements of sucrose was 0.11 per thousand without the reduction oven and improved slightly to 0.08 per thousand with the reduction oven. The filament lifetime improved by more than 600%, thereby improving the long-term system stability and analytical efficiency. In addition the costs per analysis were reduced considerably.  相似文献   

3.
Compound-specific deltaD and delta13C analyses of gas mixtures are useful indicators of geochemical and environmental factors. However, the relative concentrations of individual components in gas mixtures (e.g., H2, CO2, methane, ethane, propane, i-butane, n-butane) may vary over several orders of magnitude. The determination of hydrogen and carbon compound-specific stable isotope ratios requires that the hydrogen and carbon dioxide produced from each separated component has a concentration adjusted to match the dynamic range of the stable isotope mass spectrometer. We present a custom-built gas sampling and injection system (GASIS) linked with a Delta Plus XP mass spectrometer that provides flexibility, ease of operation, and economical use of small gas samples with wide ranges of analyte concentrations. The overall on-line GC-ox/red-IRMS (Gas Chromatography - oxidation/reduction - Isotope Ratio Mass Spectrometry) system consists of (i) a customized GASIS inlet system and (ii) two alternative reactors, namely an oxidative Cu-Ni-Pt reactor at 950 degrees C for production of CO2 and a reductive graphitized Al2O3 reactor at 1420 degrees C for production of H2. In addition, the system is equipped with (iii) a liquid nitrogen spray-cooling unit for cryo-GC-focusing at -20 degrees C, and (iv) a Nafion dryer for removal of water vapor from product CO2. The three injection loops of the GASIS inlet allow flexibility in the volume of injected analyte gas (e.g., from 0.06 to 500 microL) in order to measure reproducible deltaD and delta13C values for gases at concentrations ranging from 100% down to 10 ppm. We calibrate our GC-ox/red-IRMS system with two isotopically distinct methane references gases that are combusted off-line and characterized using dual-inlet IRMS.  相似文献   

4.
This paper discusses a simple method to determine 17O isotope excess or deficiency ('mass-independent isotopic composition') in CO2 gas. When applying conventional mass spectrometry of CO2 (m/z 44, 45 and 46) to determine the 17O/16O ratio, the 13C/12C ratio has to be established separately. This can be achieved by analysing an aliquot of sample CO2 before and after subjecting it to oxygen isotope exchange with a pool of oxygen with 'normal' 17O/16O ratio, i.e. with Delta17O approximately equal to delta17O-0.516 x delta18O = 0. Cerium oxide has been shown to be practically well suited for the exchange of CO2 oxygen; the reagent is safe and does not produce any contamination. The CO2-CeO2 exchange reaction has 99.8 +/- 0.7% recovery yield. At 650 degrees C this reaction reaches equilibrium in 30 min and, as tested, results in complete oxygen replacement. Delta17O determinations depend on accuracy of CO2 delta measurements: the repeatability of +/-0.015 per thousand (1sigma) in delta(45)R and delta(46)R determination relative to the working reference results in an error of Delta17O as small as +/-0.33 per thousand. Such a precision is sufficient for Delta17O determination in stratospheric CO2. The calculated Delta17O value systematically depends on absolute 17R and 13R ratios in isotopic reference materials, which are presently not yet known with certainty (the 17R value is most important), and may be inadequate for 17O-correction with a = 0.516. Within the present uncertainty, Delta17O determined in 17O-enriched CO2 agrees with the value directly measured in the enriched O2 from which this CO2 was produced. Besides Delta17O determination, investigated CO2-CeO2 equilibration may have several other implications. Fast, complete isotopic exchange of CO2 by reaction with CeO2 may also be employed to get reproducible 17O-correction and, hence, to better monitor small delta13C shifts and to isotopically equilibrate mixtures of CO2 gases.  相似文献   

5.
Accurate and efficient measurement of the oxygen isotope composition of carbonates (delta(C) (18)O) based on the mass spectrometric analysis of CO(2) produced by reacting carbonate samples with H(3)PO(4) is compromised by: (1) uncertainties associated with fractionation factors (alpha(CO)(2)C) used to correct measured oxygen isotope values of CO(2)(delta(CO(2)(18)O) to delta(C) (18)O; and (2) the slow reaction rates of many carbonates of geological and environmental interest with H(3)PO(4). In contrast, determination of delta(C) (18)O from analysis of CO produced by high-temperature (>1400 degrees C) pyrolytic reduction, using an elemental analyser coupled to continuous-flow isotope-ratio mass spectrometry (TC/EA CF-IRMS), offers a potentially efficient alternative that measures the isotopic composition of total carbonate oxygen and should, therefore, theoretically be free of fractionation effects. The utility of the TC/EA CF-IRMS technique was tested by analysis of carbonates in the calcite-dolomite-magnesite solid-solution and comparing the results with delta(C) (18)O measured by conventional thermal decomposition/fluorination (TDF) on the same materials. Initial results show that CO yields are dependent on both the chemical composition of the carbonate and the specific pyrolysis conditions. Low gas yields (<100% of predicted yield) are associated with positive (>+0.2 per thousand) deviations in delta(C(TC/EA) (18)O compared with delta(C(TDF) (18)O. At a pyrolysis temperature of 1420 degrees C the difference between delta(C) (18)O measured by TC/EA CF-IRMS and TDF (Delta(C(TC/EA,TDF) (18)O) was found to be negatively correlated with gas yield (r = -0.785) and this suggests that delta(C) (18)O values (with an estimated combined standard uncertainty of +/-0.38 per thousand) could be derived by applying a yield-dependent correction. Increasing the pyrolysis temperature to 1500 degrees C also resulted in a statistically significant correlation with gas yield (r = -0.601), indicating that delta(C) (18)O values (with an estimated uncertainty of +/-0.43 per thousand) could again be corrected using a yield-dependent procedure. Despite significant uncertainty associated with TC/EA CF-IRMS analysis, the magnitude of the uncertainty is similar to that associated with the application of poorly defined values of alpha(CO)(2), (C) used to derive delta(C) (18)O from delta(CO(2) (18)O measured by the H(3)PO(4) method for most common carbonate phases. Consequently, TC/EA CF-IRMS could provide a rapid alternative for the analysis of these phases without any effective deterioration in relative accuracy, while analytical precision could be improved by increasing the number of replicate analyses for both calibration standards and samples. Although automated gas preparation techniques based on the H(3)PO(4) method (ISOCARB, Kiel device, Gas-Bench systems) have the potential to measure delta(CO)(2) (18)O efficiently for specific, slowly reacting phases (e.g. dolomite), problems associated with poorly defined alpha(CO)(2), (C) remain. The application of the Principle of Identical Treatment is not a solution to the analysis of these phases because it assumes that a single fractionation factor may be defined for each phase within a solid-solution regardless of its precise chemical composition. This assumption has yet to be tested adequately.  相似文献   

6.
An online continuous-flow method, combining a thermal conversion elemental analyzer (TC/EA) with isotope ratio mass spectrometry (MS), is evaluated for the determination of both the hydrogen isotope composition and the water concentration of hydrous and nominally anhydrous minerals. The technique involves reduction of hydrous minerals or nominally anhydrous minerals by reaction with glassy carbon at 1450 degrees C in a helium stream. The product gases, H2 and CO, are separated on a gas chromatographic column prior to analysis in the mass spectrometer. Calibration curves for the H concentration analysis were generated from a standard of benzoic acid (C7H6O2) that has an H concentration of 5.0 wt%; the analytical uncertainties were better than +/-0.05% in our runs. Two standards of material with given D values, polyethylene IAEA-CH-7 and biotite NBS-30, were tested for the purpose of calibrating a natural garnet 04BXL02 representing nominally anhydrous minerals. Preheating at 90 degrees C for 12 h was found to be suitable for removing adsorption water on the sample surface. This results in constant D values and total H2O contents for the garnet, with weighted means of -94 +/- 1 and 522 +/- 11 ppm (wt), respectively. The TC/EA-MS technique allows routine analysis of sample sizes as small as 0.01 microL H2O. For natural minerals, absolute reproducibilities for D values are +/-0.5 to +/-2 (1) and relative uncertainties for total H2O concentrations are at levels of +/-1% to +/-3% (1). Therefore, this online method can be used for the quantitative determination of H isotope composition and H2O concentration of either hydrous or anhydrous minerals.  相似文献   

7.
In IMEP-8, two samples of high purity CO(2)(g), with different carbon and oxygen isotope ratios were distributed to 27 participants, originating from 14 countries and from various isotopic measurement domains (geochemistry, atmospheric and food chemistry), but particularly set up for food laboratories. In total 19 laboratories reported results. The outcome of this comparison exercise shows that the laboratories reported carbon and oxygen isotope results in good agreement with the reference values across the domains. The reported results for delta(13)C(VPDB) (carbon) for both materials are within 1 per thousand. However, for the reported results of delta(18)O(VPDB) (oxygen) for both materials the overall spread of the reported results is about 11 per thousand. Within this spread two distinct groups of participants can be identified, where the results within each group vary about 2 per thousand. The latter seems to be caused by calculation errors by participants of the reporting delta(18)O(VPDB) values. As requested, participants also reported the isotope amount ratio for carbon and oxygen in the CO(2) samples. For carbon, all reported results for both materials agree with the isotope ratio value, which can be traced back to the value reported by Craig. For oxygen, all results are in good agreement and deviate by a maximum of 0.5% from the reference values measured at IRMM. Work carried out indicates the carbon isotope ratio, for both samples IMEP-8A and IMEP-8B, differ from those reported by Craig by as much as 1.2%. In the case of oxygen, this deviation is far smaller. Both data sets, i.e. the one realised by Craig and the one realised at IRMM, demonstrate traceability to SI. It is clear that both values significantly disagree.  相似文献   

8.
The stable isotope composition of nmol size gas samples can be determined accurately and precisely using continuous flow isotope ratio mass spectrometry (IRMS). We have developed a technique that exploits this capability in order to measure delta13C and delta18O values and, simultaneously, the concentration of CO2 in sub-mL volume soil air samples. A sampling strategy designed for monitoring CO2 profiles at particular locations of interest is also described. This combined field and laboratory technique provides several advantages over those previously reported: (1) the small sample size required allows soil air to be sampled at a high spatial resolution, (2) the field setup minimizes sampling times and does not require powered equipment, (3) the analytical method avoids the introduction of air (including O2) into the mass spectrometer thereby extending filament life, and (4) pCO2, delta13C and delta18O are determined simultaneously. The reproducibility of measurements of CO2 in synthetic tank air using this technique is: +/-0.08 per thousand (delta13C), +/-0.10 per thousand (delta18O), and +/-0.7% (pCO2) at 5550 ppm. The reproducibility for CO2 in soil air is estimated as: +/-0.06 per thousand (delta13C), +/-0.06 per thousand (delta18O), and +/-1.6% (pCO2). Monitoring soil CO2 using this technique is applicable to studies concerning soil respiration and ecosystem gas exchange, the effect of elevated atmospheric CO2 (e.g. free air carbon dioxide enrichment) on soil processes, soil water budgets including partitioning evaporation from transpiration, pedogenesis and weathering, diffuse solid-earth degassing, and the calibration of speleothem and pedogenic carbonate delta13C values as paleoenvironmental proxies.  相似文献   

9.
A simple and effective method for the conversion of organic carbon into carbon dioxide for analysis of stable carbon isotopes (delta(13)C) in samples of various organic substances, soils, sedimentary rocks, oils and volatile organic liquids is presented. The conversion of organic carbon of the samples is carried out in a quartz reactor connected to a vacuum line for CO(2) freezing and purification. A solid organic sample mixed with CuO is placed at the reactor bottom and the reactor is subsequently filled with granular CuO. One end of the CuO column is preheated to 850 degrees C while the other end of the column in contact with the sample is kept at ambient temperature. Heating of the sample (850 degrees C) and the remainder of the column is then performed. The preheated part of the column provides efficient conversion of carbon into CO(2). The reactor for the conversion of volatile liquid organic compounds is filled with granular CuO. The column of CuO is heated to 850 degrees C. Samples of volatile liquids are introduced into the reactor through a septum using a microsyringe. Complete conversion takes 10 min for solid samples and 3 min for volatile liquids. The precision of the delta(13)C analysis for solid and volatile liquid organic substances is +/-0.1 per thousand and +/-0.04 per thousand, respectively.  相似文献   

10.
Degradation experiments of benzoate by Pseudomonas putida resulted in enzymatic carbon isotope fractionations. However, isotopic temperature effects between experiments at 20 and 30 degrees C were minor. Averages of the last three values of the CO(2) isotopic composition (delta(13)C(CO2(g))) were more negative than the initial benzoate delta(13)C value (-26.2 per thousand Vienna Pee Dee Belenite (VPDB)) by 3.8, 3.4 and 3.2 per thousand at 20, 25 and 30 degrees C, respectively. Although the maximum isotopic temperature difference found was only 0.6 per thousand, more extreme temperature variations may cause larger isotope effects. In order to understand the isotope effects on the total inorganic carbon (TIC), a better measure is to calculate the proportions of the inorganic carbon species (CO(2)(g), CO(2)(aq) and HCO(3)(-)) and to determine their cumulative delta(13)C(TIC). In all three experiments delta(13)C(TIC) was more positive than the initial isotopic composition of the benzoate at a pH of 7. This suggests an uptake of (12)C in the biomass in order to match the carbon balance of these closed system experiments.  相似文献   

11.
Even though the recent development in on-line methods for the stable isotope determination in cellulose has led to a significant increase in sample throughput and decrease in sample preparation expenditure, there still is a large potential for optimizing the analytical procedures by simultaneously measuring the isotope ratios of two or even more elements. Therefore, the main objective of this study was to answer the question whether high-temperature pyrolysis (HTP) is a suitable and reliable technique for the determination of the carbon isotopic composition of cellulose simultaneously during the well-known conventional oxygen isotope analysis. This study shows that HTP of cellulose is a technique that can produce reasonable delta(13)C values, matching the requirements of most research problems related to paleoclimatology. The reproducibility of the delta values for (13)C/(12)C is better than 0.2 per thousand. Some deficiencies of the method are related to the incomplete conversion of the organic carbon in the sample to carbon monoxide. A clear isotope effect seems to be related to the non-statistical conversion of the carbon in the cellulose to CO. The extent of this effect appears to be controlled by the relative proportion of crystallized and amorphous matter in the cellulose structure. Those deficiencies can be eliminated by using an appropriate normalization and by applying the principles of identical treatment for reference materials and samples. In general, a very good agreement is achieved for carbon isotope values determined by HTP and elemental analysis (EA).  相似文献   

12.
A wet oxidation method for the compound-specific determination of stable carbon isotopes (delta(13)C) of organic acids in the gas and aerosol phase, as well as of water-soluble organic carbon (WSOC), is presented. Sampling of the organic acids was done using a wet effluent diffusion denuder/aerosol collector (WEDD/AC) coupled to an ion chromatography (IC) system. The method allows for compound-specific stable carbon isotope analysis by collecting different fractions of organic acids at the end of the IC system using a fraction collector. delta(13)C analyses of organic acids were conducted by oxidizing the organic acids with sodium persulfate at a temperature of 100 degrees C and determining the delta(13)C value of the resulting carbon dioxide (CO(2)) with an isotope ratio mass spectrometer. In addition, analysis of delta(13)C of the WSOC was performed for particulate carbon collected on aerosol filters. The WSOC was extracted from the filters using ultrapure water (MQ water), and the dissolved organic carbon was oxidized to CO(2) using the oxidation method. The wet oxidation method has an accuracy of 0.5 per thousand with a precision of +/-0.4 per thousand and provides a quantitative result for organic carbon with a detection limit of 150 ng of carbon.  相似文献   

13.
The quantitative conversion of organically bound oxygen into CO, a prerequisite for the 18O/16O analysis of organic compounds, is generally performed by high‐temperature conversion in the presence of carbon at ~1450°C. Since this high‐temperature procedure demands complicated and expensive equipment, a lower temperature method that could be utilized on standard elemental analyzers was evaluated. By substituting glassy carbon with carbon black, the conversion temperature could be reduced to 1170°C. However, regardless of the temperature, N‐containing compounds yielded incorrect results, despite quantitative conversion of the bound oxygen into CO. We believe that the problems were partially caused by interfering gases produced by a secondary decomposition of N‐ and C‐containing polymers formed during the decomposition of the analyte. In order to overcome the interference, we replaced the gas chromatographic (GC) separation of CO and N2 by reversible CO adsorption, yielding the possibility of collecting and purifying the CO more efficiently. After CO collection, the interfering gases were vented by means of a specific stream diverter, thus preventing them from entering the trap and the mass spectrometer. Simultaneously, a make‐up He flow was used to purge the gas‐specific trap before the desorption of the CO and its subsequent mass spectrometric analysis. Furthermore, the formation of interfering gases was reduced by the use of polyethylene as an additive for analytes with a N:O ratio greater than 1. These methodological modifications to the thermal conversion of N‐containing analytes, depending on their structure or O:N ratio, led to satisfactory results and showed that it was possible to optimize the conditions for their individual oxygen isotope ratio analysis, even at 1170°C. With these methodological modifications, correct and precise δ18O results were obtained on N‐containing analytes even at 1170°C. Differences from the expected standard values were below ±1‰ with standard deviations of the analysis <0.2‰. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
We have developed an analytical system to determine stable isotopic compositions (delta13C and delta18O) of sub-microgram quantities of CaCO3 for the purpose of analyzing individual foraminiferal shells, using continuous-flow isotope ratio mass spectrometry (CF-IRMS). The system consists of a micro-volume CaCO3 decomposition tube, stainless steel CO2 purification vacuum line with a quantity-regulating unit, helium-purged CO2 purification line, gas chromatograph, and a CF-IRMS system. By using this system, we can determine stable carbon and oxygen isotopic compositions as low as 0.2 microg of CaCO3, with standard deviations of +/-0.10 per thousand for delta13C and +/-0.18 per thousand for delta18O within a 4-h reaction time and 30-min analysis period.  相似文献   

15.
A reactor for converting cellulose into carbon monoxide for subsequent oxygen isotopic analysis via continuous flow isotope ratio mass spectrometry is described. The system employs an induction heater to produce temperatures >or=1500 degrees C within a molybdenum foil crucible positioned by boron nitride (BN) spacers within a quartz outer sleeve. For samples of a homogeneous working standard cellulose between 300 and 400 microg in size, the blank/signal ratio is <5%, and the long-term precision is 0.30 per thousand (N = 232). For samples of 30 to 100 microg in size, a gas pressure sintered silicon nitride (Si(3)N(4)) outer sleeve replaces the quartz sleeve, the BN spacers are not used, and 6.0-grade carrier He must be used to minimize the blank signal. With these modifications a blank/sample ratio of <5% and long-term precision of 0.30 per thousand (N = 144) are obtained. These results are similar to those achieved using standard high-temperature furnaces, but the reactor is simpler to pack, the system is more economical to run, and samples as small as 30 microg cellulose may be measured. For both reactors memory is significant in the subsequent sample and is believed to be due to exchange with reactor oxygen at temperatures above 1000 degrees C. Further applications might include online preparation of other materials requiring temperatures of 1500-2600 degrees C.  相似文献   

16.
A computer-controllable mobile system is presented which enables the automatic collection of 33 air samples in the field and the subsequent analysis for delta13C and delta18O stable isotope ratios of a carbon-containing trace gas in the laboratory, e.g. CO2, CO or CH4. The system includes a manifold gas source input for profile sampling and an infrared gas analyzer for in situ CO2 concentration measurements. Measurements of delta13C and delta18O of all 33 samples can run unattended and take less than six hours for CO2. Laboratory tests with three gases (compressed air with different pCO2 and stable isotope compositions) showed a measurement precision of 0.03 per thousand for delta13C and 0.02 per thousand for delta18O of CO2 (standard error (SE), n = 11). A field test of our system, in which 66 air samples were collected within a 24-hour period above grassland, showed a correlation of 0.99 (r2) between the inverse of pCO2 and delta13C of CO2. Storage of samples until analysis is possible for about 1 week; this can be an important factor for sampling in remote areas. A wider range of applications in the field is open with our system, since sampling and analysis of CO and CH4 for stable isotope composition is also possible. Samples of compressed air had a measurement precision (SE, n = 33) of 0.03 per thousand for delta13C and of 0.04 per thousand for delta18O on CO and of 0.07 per thousand for delta13C on CH4. Our system should therefore further facilitate research of trace gases in the context of the carbon cycle in the field, and opens many other possible applications with carbon- and possibly non-carbon-containing trace gases.  相似文献   

17.
CO oxidation and decomposition behaviors over nanosized 3% Au/alpha-Fe2O3 catalyst and over the alpha-Fe2O3 support were studied in situ via thermogravimetry coupled to on-line FTIR spectroscopy (TG-FTIR), which was used to obtain temperature-programmed reduction (TPR) curves and evolved gas analysis. The catalyst was prepared by a sonication-assisted Au colloid based method and had a Au particle size in the range of 2-5 nm. Carburization studies of H 2-prereduced samples were also made in CO gas. According to gravimetry, for the 3% Au/alpha-Fe2O3 catalyst, there were three distinct stages of CO interaction with the Au catalyst but only two stages for the catalyst support. At low temperatures (相似文献   

18.
The oxygen isotope fractionation associated with O+CO-->CO(2) reaction was investigated experimentally where the oxygen atom was derived from ozone or oxygen photolysis. The isotopic composition of the product CO(2) was analyzed by mass spectrometry. A kinetic model was used to calculate the expected CO(2) composition based on available reaction rates and their modifications for isotopic variants of the participating molecules. A comparison of the two (experimental data and model predictions) shows that the product CO(2) is endowed with an anomalous enrichment of heavy oxygen isotopes. The enrichment is similar to that observed earlier in case of O(3) produced by O+O(2) reaction and varies from 70 0/00 to 136 0/00 for (18)O and 41 0/00 to 83 0/00 for (17)O. Cross plot of delta (17)O and delta (18)O of CO(2) shows a linear relation with slope of approximately 0.90 for different experimental configurations. The enrichment observed in CO(2) does not depend on the isotopic composition of the O atom or the sources from which it is produced. A plot of Delta(delta (17)O) versus Delta(delta (18)O) (two enrichments) shows linear correlation with the best fit line having a slope of approximately 0.8. As in case of ozone, this anomalous enrichment can be explained by invoking the concept of differential randomization/stabilization time scale for two types of intermediate transition complex which forms symmetric ((16)O(12)C(16)O) molecule in one case and asymmetric ((16)O(12)C(18)O and (16)O(12)C(17)O) molecules in the other. The delta (13)C value of CO(2) is also found to be different from that of the initial CO due to the mass dependent fractionation processes that occur in the O+CO-->CO(2) reaction. Negative values of Delta(delta (13)C) ( approximately 12.1 0/00) occur due to the preference of (12)C in CO(2)* formation and stabilization. By contrast, at lower pressures (approximately 100 torr) surface induced deactivation makes Delta(delta (13)C) zero or slightly positive.  相似文献   

19.
The determination of delta18O values in CO2 at a precision level of +/-0.02 per thousand (delta-notation) has always been a challenging, if not impossible, analytical task. Here, we demonstrate that beyond the usually assumed major cause of uncertainty - water contamination - there are other, hitherto underestimated sources of contamination and processes which can alter the oxygen isotope composition of CO2. Active surfaces in the preparation line with which CO2 comes into contact, as well as traces of air in the sample, can alter the apparent delta18O value both temporarily and permanently. We investigated the effects of different surface materials including electropolished stainless steel, Duran glass, gold and quartz, the latter both untreated and silanized. CO2 frozen with liquid nitrogen showed a transient alteration of the 18O/16O ratio on all surfaces tested. The time to recover from the alteration as well as the size of the alteration varied with surface type. Quartz that had been ultrasonically cleaned for several hours with high purity water (0.05 microS) exhibited the smallest effect on the measured oxygen isotopic composition of CO2 before and after freezing. However, quartz proved to be mechanically unstable with time when subjected to repeated large temperature changes during operation. After several days of operation the gas released from the freezing step contained progressively increasing trace amounts of O2 probably originating from inclusions within the quartz, which precludes the use of quartz for cryogenically trapping CO2. Stainless steel or gold proved to be suitable materials after proper pre-treatment. To ensure a high trapping efficiency of CO2 from a flow of gas, a cold trap design was chosen comprising a thin wall 1/4" outer tube and a 1/8" inner tube, made respectively from electropolished stainless steel and gold. Due to a considerable 18O specific isotope effect during the release of CO2 from the cold surface, the thawing time had to be as long as 20 min for high precision delta18O measurements. The presence of traces of air in almost all CO2 gases that we analyzed was another major source of error. Nitrogen and oxygen in the ion source of our mass spectrometer (MAT 252, Finnigan MAT, Bremen, Germany) give rise to the production of NO2 at the hot tungsten filament. NO2+ is isobaric with C16O18O+ (m/z 46) and interferes with the delta18O measurement. Trace amounts of air are present in CO2 extracted cryogenically from air at -196 degrees C. This air, trapped at the cold surface, cannot be pumped away quantitatively. The amount of air present depends on the surface structure and, hence, the alteration of the measured delta18O value varies with the surface conditions. For automated high precision measurement of the isotopic composition of CO2 of air samples stored in glass flasks an extraction interface ('BGC-AirTrap') was developed which allows 18 analyses (including standards) per day to be made. For our reference CO2-in-air, stored in high pressure cylinders, the long term (>9 months) single sample precision was 0.012 per thousand for delta13C and 0.019 per thousand for delta18O.  相似文献   

20.
CeO2 oxygen carrier was prepared by precipitation method and tested by two-step steam reforming of methane (SRM). Two-step SRM for hydrogen and syngas generation is investigated in a fixed-bed reactor. Methane is directly converted to syngas at a H2/CO ratio close to 2 : 1 at a high temperature (above 750 °C) by the lattice oxygen of CeO2; methane cracking is found when the reduction degree of CeO2 was above 5.0% at 850 °C in methane isothermal reaction. CeO2?δ obtained from methane isothermal reaction can split water to generate CO-free hydrogen and renew its lattice oxygen at 700 °C; simultaneously, deposited carbon is selectively oxidized to CO2 by steam following the reaction (C+2H2O→CO2+2H2). Slight deactivation in terms of amounts of desired products (syngas and hydrogen) is observed in ten repetitive two-step SRM process due to the carbon deposition on CeO2 surface as well as sintering of CeO2.  相似文献   