首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到7条相似文献,搜索用时 0 毫秒
1.
2.
This paper reports on the accuracy and sensitivity of digital speckle pattern interferometry (DSPI) when it is combined with the hole drilling technique for measuring residual stresses. The in-plane displacement field generated by the introduction of a small hole is determined using an automated data analysis approach. This method is based on the calculation of the optical phase distribution through a phase-shifting method and the application of a robust iterative phase unwrapping algorithm. It is experimentally demonstrated that residual stresses can be measured with a relative uncertainty of 7.5%. It is also shown that the minimum value of residual stress that can be determined with the DSPI and hole drilling combined technique is about 10% of the yield stress of the material.  相似文献   

3.
一种新的数字散斑振动定量分析系统   总被引:1,自引:1,他引:1       下载免费PDF全文
在数字散斑干涉(DSPI)测量方法中,数字散斑时间平均法测量振动时得到的是贝塞尔条纹,其定量分析比较困难。该文采用贝塞尔条纹准相移技术进行数字散斑振动定量分析,即在参考光路中引入和物体同频率的偏置参考振动,当参考振动的相位改变时,振动条纹会产生移动,这相当于静态余弦条纹的相移,可以采用相移算法对数字散斑振动测量的贝塞尔条纹进行定量分析。文中开发了一种新的数字散斑振动定量分析系统,研制了一种低压光学相移器和测量控制电路,给出了圆周固定圆片和四周固定方铜板的振动测量结果。实验结果表明:采用本系统可以方便地定量测出物体的振动模态。  相似文献   

4.
5.
Main features inherent in simplified approach to residual stresses determination in cylindrical shells and tubes, external diameter of which is not less than 60 mm, by combing the hole-drilling method and reflection hologram interferometry are discussed in detail. Initial experimental information in a form of hole diameter increments in principal stress directions is derived from high-quality reflection holograms recorded near cylindrical objects of intermediate curvature value. Converting measured parameters into required stress values is based on the transition model that corresponds to plane stress conditions of pure membrane type. The technique developed is capable of determining residual stress component values within 5% accuracy in an absence of stress gradients over the probe hole diameter when a type of residual stress field corresponds to the transition model adopted. The accuracy analysis involved is based on matrix formulation of conventionally direct problem and an assumption on a pure membrane character of residual stress field under study for thin-walled shell. Required error estimations in a case of inspecting thick-walled cylindrical tube are obtained by combining the above-mentioned approach and an analogy of reconstructed fringe patterns with actual and artificial interferograms, which follow from drilling blind hole of the same geometrical parameters in thick-walled plates. Experimental verification of the developed approach is founded upon a determination of actual stresses in thin-walled cylindrical shell and obtaining residual stress distributions at the proximity of welded joint in thick-walled cylindrical tube.  相似文献   

6.
A method for measuring the axial residual stress profile in axisymmetric optical fibers is presented. The procedure is based on integrated photoelasticity and a fringe shifting technique is used to measure the optical retardation. The radial distribution of the axial residual stress is reconstructed using the inverse Abel transform. The paper describes the operating principle, the experimental setup and the results obtained on a multimode fiber are also reported. The influence of the measurement errors is finally discussed.  相似文献   

7.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号