首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and specific high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assay for the determination of rivastigmine and its major metabolite NAP 226-90 is presented. A 100 microL plasma aliquot was spiked with a structural analogue of rivastigmine as internal standard (PKF214-976-AE-1) and proteins were precipitated by adding 200 microL of methanol. After centrifugation a volume of 100 microL of the clear supernatant was mixed with 100 microL of methanol/water (30:70, v/v) and volumes of 25 microL were injected onto the HPLC system. Separation was acquired on a 150 x 2.0 mm i.d. Gemini C18 column using a gradient system with 10 mM ammonium hydroxide and methanol. Detection was performed by using a turboionspray interface and positive ion multiple reaction monitoring by tandem mass spectrometry. The assay quantifies rivastigmine from 0.25 to 50 ng/mL and its metabolite NAP 226-90 from 0.50 to 25 ng/mL, using human plasma samples of 100 microL. Validation results demonstrate that rivastigmine and metabolite concentrations can be accurately and precisely quantified in human EDTA plasma. This assay is now used to support clinical pharmacologic studies with rivastigmine.  相似文献   

2.
A sensitive and specific high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assay for the quantitative determination of gemcitabine (dFdC) and its metabolite 2',2'-difluorodeoxyuridine (dFdU) is presented. A 200-microL aliquot of human plasma was spiked with a mixture of internal standards, didanosine, lamivudine and fludarabine, and extracted using solid-phase extraction. Dried extracts were reconstituted in 1 mM ammonium acetate/acetonitrile (97:3, v/v) and 10-microL volumes were injected onto the HPLC system. Separation was achieved on a 150 x 2.1 mm C18 bonded phase endcapped with polar groups (Synergi Hydro-RP column) using an eluent composed of 1 mM ammonium acetate (pH 6.8)/acetonitrile (94:6, v/v). Detection was performed by positive ion electrospray ionization followed by MS/MS. The assay quantifies a range from 0.5 to 1000 ng/mL for gemcitabine and from 5 to 10,000 ng/mL for dFdU using 200 microL of human plasma sample. Validation results demonstrate that gemcitabine and dFdU concentrations can be accurately and precisely quantified in human plasma. This assay is used to support clinical pharmacologic studies with gemcitabine.  相似文献   

3.
An assay for the quantitative determination of docetaxel in human plasma is described. Docetaxel was extracted from the matrix using liquid-liquid extraction with ter-butylmethylether, followed by high-performance liquid chromatographic analysis using an alkaline eluent. Paclitaxel was used as internal standard. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. The validated range for docetaxel was from 0.25--1000 ng/mL using 200 microL plasma aliquots. The method requires only a limited volume (200 microL) of human plasma and the method can be applied in studies requiring a low lower limit of quantitation of 0.25 ng/mL. The assay was applied successfully in several clinical and pharmacological studies with docetaxel.  相似文献   

4.
A quantitative liquid chromatography/ion trap mass spectrometry method for the simultaneous determination of paclitaxel, 6alpha-hydroxypaclitaxel and p-3'-hydroxypaclitaxel in human plasma has been developed and validated. 6alpha-,p-3'-Dihydroxypaclitaxel was also quantified using paclitaxel as a reference and docetaxel as an internal standard. The substances were extracted from 0.500 mL plasma using solid-phase extraction. The elution was performed with acetonitrile and the samples were reconstituted in the mobile phase. Isocratic high-performance liquid chromatography analysis was performed by injecting 50 microL of reconstituted material onto a 100 x 3.00 mm C12 column with a methanol:1% trifluoroacetic acid/ammonium trifluoroacetate in H(2)O 70:30 mobile phase at 350 microL/min. The [M+H](+) ions generated in the sonic spray ionization interface were isolated and fragmented using two serial mass spectrometric methods: one for paclitaxel (transition 854 --> 569 & 551) and the dihydroxymetabolite (transition 886 --> 585 & 567) and one for the hydroxy metabolites (transition 870 --> 585 & 567; transition 870 --> 569 & 551) and docetaxel ([M+Na](+), transition 830 --> 550). Calibration curves were created ranging between 0.5 and 7500 ng/mL for paclitaxel, 0.5 and 750 ng/mL for 6alpha-hydroxypaclitaxel, and 0.5 and 400 ng/mL for p-3'-hydroxypaclitaxel. Adduct ion formation was noted and investigated during method development and controlled by mobile phase optimization. In conclusion, a sensitive method for simultaneous quantification of paclitaxel and its metabolites suitable for analysis in clinical studies was obtained.  相似文献   

5.
Rapid, selective, and sensitive methodology for the quantification of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in human plasma using packed capillary liquid chromatography coupled to electrospray ionization ion-trap mass spectrometry has been developed. Plasma proteins were precipitated using acetonitrile and the resulting supernatant was diluted 1+1 with water containing 10 mM ammonium acetate (NH4Ac) prior to injection. Sample volumes of 250 microL were loaded onto a 30 mm x 0.32 mm ID 10 microm Kromasil C18 precolumn by a carrier solution consisting of 10 mM NH4Ac in ACN/H2O (5/95, v/v) at a flow rate of 100 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 100 mm x 0.32 mm ID 3.5 microm Kromasil C18 analytical column was conducted using an ACN/H2O solvent gradient containing 10 mM NH4Ac. In order to improve the robustness and performance of the method, perfluoroheptanoic acid (PFHA) was used as internal standard. Separation and detection of PFOA, PFHA, and PFOS were achieved within 10 minutes. Ionization was performed in the negative mode in the m/z range 250-550. The method was validated over the concentration range 1-200 ng/mL for PFOA and over the range 5-200 ng/mL untreated plasma for PFOS, yielding correlation coefficients of 0.997 (PFOA) and 0.996 (PFOS), respectively. The within-assay (n = 6) and between-assay (n = 6) precisions were in the range 2.1-9.2 and 5.6-12%, respectively. The concentration limits of detection (cLOD) of PFOA was 0.5 ng/mL while the cLOD of PFOS was estimated to be 0.2 ng/mL in untreated plasma.  相似文献   

6.
A sensitive and specific assay for paclitaxel in plasma has been developed to overcome limitations in previously published assays, using liquid chromatography with tandem mass spectrometric detection. Plasma samples (100 microL) were subjected to liquid-liquid extraction with 1-chlorobutane/acetonitrile (4:1, v/v), with [(2)H(5)]paclitaxel employed as the internal standard. Chromatography was carried out with a Waters SymmetryShield C8 column (50 x 2.1 mm, 3.5 microm). The total run time, including equilibration, was 8 min, using a gradient of acetonitrile and 10 mM ammonium formate, pH 4.0. The assay is accurate and precise over the range of 2-2500 ng/mL and has been successfully applied to study the clinical pharmacokinetics of two formulations of paclitaxel, Genaxol and Genetaxyl, given orally and intravenously.  相似文献   

7.
The development of a liquid chromatography/tandem mass spectrometric assay for the quantitative analysis of the novel tubulin inhibitor D-24851 in human plasma and urine is described. D-24851 and the deuterated internal standard were extracted from 250 microL of plasma or urine using hexane/ether (1:1, v/v). Subsequently, 10-microL aliquots of reconstituted extracts were injected onto an Inertsil ODS analytical column (50 x 2.0 mm i.d., 5 microm particle size). An eluent consisting of methanol/5 mM ammonium acetate, 0.004% formic acid in water (80:20, v/v) was pumped at a flow rate of 0.2 mL/min. An API 365 triple quadrupole mass spectrometer was used in the multiple reaction monitoring mode for sensitive detection. For human plasma a dynamic range of 1-1000 ng/mL was validated, and for human urine a range of 0.25-50 ng/mL. Validation was performed according to the most recent FDA guidelines and all results were within requirements. The assay has been successfully applied to support a phase I clinical trial with orally administered D-24851.  相似文献   

8.
A simple, rapid and sensitive LC‐UV method was developed and validated for the determination of paclitaxel (PTX) in rabbit plasma and tissues. A 2 mL aliquot of acetonitrile and 10 μL ammonium acetate (pH 5.0, 6 m ) as extraction agents were used to markedly increase the extraction recoveries and greatly reduce the endogenous substances. The separation was achieved on a C18 column at 30 °C using an acetonitrile–ammonium acetate buffer (pH 5.0, 0.02 m ; 55:45, v/v) at a flow rate of 1.0 mL/min; UV detection was used at 227 nm. Good linearity was obtained between 0.025 and 10,000 µg/mL for plasma and between 0.025–200,000 µg/g for tissue samples (r > 0.999). The limit of detection was 6 ng/mL in plasma, 8 ng/g in heart and 12.5 ng/g in other tissues. The limit of quantitation was 25 ng/mL in plasma and heart, 125 ng/g in other tissues. The intra‐ and inter‐day assays of precision and accuracy for all bio‐samples ranged from 1.38 to 9.60% and from 83.6 to 114.5%, respectively. The extraction recoveries ranged from 70.1 to 109.5%. Samples were stable during three freeze–thaw cycles or stored in a freezer at ?20 °C for 30 days. The assay method was successfully applied to a study of the pharmacokinetics and tissue distribution of novel PTX lung targeting liposomes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive and specific liquid chromatography-positive electrospray ionization-tandem mass spectrometry method has been developed and validated for the determination of glimepiride (GPD) in human plasma. GPD and the internal standard (IS, glibenclamide) were extracted from a small aliquot of human plasma (200 microL) by a simple liquid-liquid extraction technique using ethyl acetate as extraction solvent. The compounds were separated on a YMC Propack, C18, 4.6x50 mm column using a mixture of ammonium acetate buffer, acetonitrile and methanol (30:60:10, v/v) as mobile phase at 0.5 mL/min on an API 4000 Sciex mass spectrometer connected to an Agilent HPLC system. Method validation and pre-clinical sample analysis was performed as per FDA guidelines and the results met the acceptance criteria. GPD and IS were detected without any interference from human plasma matrix. The method was proved to be accurate and precise at linearity range of 0.02-100.00 ng/mL with a correlation coefficient of 0.999. The method was robust with a lower limit of quantitation of 0.02 ng/mL. Intra- and inter-day accuracies for GPD were 88.60-113.50 and 96.82-103.93%, respectively. The inter-day precision was better than 12.21%. This method enabled faster and reliable determination of GPD in a pre-clinical study.  相似文献   

10.
An LC-MS/MS method for the simultaneous determination of a new P-glycoprotein inhibitor 4-oxo-4H-chromene-2-carboxylic acid [2-(2-(4-[2-(6,7-dimethoxy-3,4-dihydro-1H-isoquinolin-2-yl)-ethyl]-phenyl)-2H-tetrazol-5-yl)-4,5-dimethoxy-phenyl]-amide (HM-30181) and a P-glycoprotein substrate paclitaxel in rat plasma was developed to simultaneously evaluate the pharmacokinetics of paclitaxel and HM-30181 in the rats. HM-30181, paclitaxel, HM-30059 (internal standard (I.S.) for HM-30181), and docetaxel (I.S. for paclitaxel) were extracted from rat plasma with methyl-tert-butyl ether and analyzed on an Atlantis C18 column (5 microm, 2.1 x 100 mm) with the mobile phase of ACN/10 mM ammonium formate (75:25 v/v). The analytes were detected using an ESI MS/MS in the multiple reaction monitoring (MRM) mode. The standard curves for HM-30181 and paclitaxel in plasma were linear (r > 0.999) over the concentration range of 2.0-500 ng/mL with a weighting of 1/concentration2. The method showed a satisfactory sensitivity (2 ng/mL using 50 microL plasma), precision (CV: < or = 6.6%), accuracy (relative error: -6.3 to 2.0%), and selectivity. This method was successfully applied to the pharmacokinetic study of HM-30181 and paclitaxel in rat plasma after oral-coadministration of paclitaxel and HM-30181 to male Sprague- Dawley rats.  相似文献   

11.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of zafirlukast (ZFK) with 500 microL human plasma using valdecoxib as an internal standard (IS). The API-4,000 LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of ZFK and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with 10 mm ammonium acetate (pH 6.4):acetonitrile (20:80, v/v) on a Hypersil BDS C(18) column. The total chromatographic run time was 2.0 min and the elution of ZFK and IS occurred at approximately 1.11 and 1.58 min, respectively. The MS/MS ion transitions monitored were 574.2 --> 462.1 for ZFK and 313.3 --> 118.1 for IS. The method was proved to be accurate and precise at a linearity range of 0.15-600 ng/mL with a correlation coefficient (r) of >or=0.999. The method was rugged with 0.15 ng/mL as lower limit of quantitation. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 20 mg ZFK tablet.  相似文献   

12.
Kaletra is an important antiretroviral drug, which has been developed by Abbott Laboratories. It is composed of lopinavir (low-pin-a-veer) and ritonavir (ri-toe-na-veer). Both have been proved to be human immunodeficiency virus (HIV) protease inhibitors and have substantially reduced the morbidity and mortality associated with HIV-1 infection. We have developed and validated an assay, using liquid chromatography coupled with atmospheric pressure chemical ionization tandem mass spectrometry (LC/MS/MS), for the routine quantification of lopinavir and ritonavir in human plasma, in which lopinavir and ritonavir can be simultaneously analyzed with high throughput. The sample preparation consisted of liquid-liquid extraction with a mixture of hexane: ethyl acetate (1:1, v/v), using 100 microL of plasma. Chromatographic separation was performed on a Waters Symmetry C(18) column (150 mm x 3.9 mm, particle size 5 microm) with reverse-phase isocratic using mobile phase of 70:30 (v/v) acetonitrile: 2 mM ammonium acetate aqueous solution containing 0.01% formic acid (v/v) at a flow rate of 1.0 mL/min. A Waters symmetry C(18) guard column (20 mm x 3.9 mm, particle size 5 microm) was connected prior to the analytical column, and a guard column back wash was performed to reduce the analytical column contamination using a mixture of tetrahydrofuran (THF), methanol and water (45:45:10, v/v/v). The analytical run was 4 min. The use of a 96-well plate autosampler allowed a batch size up to 73 study samples. A triple-quadrupole mass spectrometer was operated in a positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over the concentration ranges of 19-5,300 ng/mL for lopinavir and 11-3,100 ng/mL for ritonavir. A-86093 was used as an internal standard (I.S.). The relative standard deviation (RSD) were <6% for both lopinavir and ritonavir. Mean accuracies were between the designed limits (+/-15%). The robust and rapid LC/MS/MS assay has been successfully applied for routine assay to support bioavailability, bioequivalence, and pharmacokinetics studies.  相似文献   

13.
An SPE-LC-MS/MS method was developed, validated and applied to the determination of nicotine and five major metabolites in human urine: cotinine, trans-3'-hydroxycotinine, nicotine-N-glucuronide, cotinine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide. A 500 microL urine sample was pH-adjusted with phosphate buffer (1.5 mL) containing nicotine-methyl-d3, cotinine-methyl-d3 and trans-3'-hydroxycotinine-methyl-d3 internal standards. For the unconjugated metabolites, an aliquot (800 microL) of the buffered solution was applied to a 30 mg Oasis HLB-SPE column, rinsed with 2% NH4OH/H2O (3.0 mL) and H2O (3.0 mL) and eluted with methanol (500 microL). The eluate was analyzed isocratically (100% methanol) by LC-MS/MS on a diol column (50 x 2.1 mm). For the total metabolites, a beta-glucuronidase/buffer preparation (100 microL) was added to the remaining buffered solution and incubated at 37 degrees C (20 h). An aliquot (800 microL) of the enzymatically treated buffered solution was extracted and analyzed in the same manner. The conjugated metabolites were determined indirectly by subtraction. The quantitation range of the method (ng/mL) was 14-10,320 for nicotine, 15-9800 for cotinine and 32-19,220 for trans-3'-hydroxycotinine. The validated method was used to observe diurnal variations from a smoker's spot urine samples, elimination half-lives from a smoker's 24 h urine samples and metabolite distribution profiles in the spot and 24 h urine samples.  相似文献   

14.
A sensitive and reproducible method for the determination of morphine and the metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) was developed. The method was validated for perfusion fluid used in microdialysis as well as for sheep and human plasma. A C18 guard column was used to desalt the samples before analytical separation on a ZIC HILIC (hydrophilic interaction chromatography) column and detection with tandem mass spectrometry (MS/MS). The mobile phases were 0.05% trifluoroacetic acid (TFA) for desalting and acetonitrile/5 mM ammonium acetate (70:30) for separation. Microdialysis samples (5 microL) were directly injected onto the system. The lower limits of quantification (LLOQ) for morphine, M3G and M6G were 0.50, 0.22 and 0.55 ng/mL, respectively, and the method was linear from LLOQ to 200 ng/mL. For plasma, a volume of 100 microL was precipitated with acetonitrile containing internal standards (deuterated morphine and metabolites). The supernatant was evaporated and reconstituted in 0.05% TFA before the desalting process. The LLOQs for sheep plasma were 2.0 and 3.1 ng/mL and the ranges were 2.0-2000 and 3.1-3100 ng/mL for morphine and M3G, respectively. For human plasma, the LLOQs were 0.78, 1.49 and 0.53 ng/mL and the ranges were 0.78-500, 1.49-1000 and 0.53-500 ng/mL for morphine, M3G and M6G, respectively.  相似文献   

15.
A column‐switching liquid chromatography/electrospray ionization tandem mass spectrometry to determine paclitaxel and its metabolites, 6α‐hydroxypaclitaxel and p‐3′‐hydroxypaclitaxel, in human plasma was developed. The analytical system had a Shim‐Pack MAYI‐ODS (10 × 4.6 mm i.d.) trapping column with deproteinization ability that concentrates analytes and removes water‐soluble components. This method covered a linearity range of 5–5000 ng/mL of concentrations in plasma for paclitaxel, a range of 0.87–870 ng/mL for 6α‐hydroxypaclitaxel and a range of 0.87–435 ng/mL for p‐3′‐hydroxypaclitaxel. The intra‐day precision and inter‐day precision of analysis were less than 11.1%, and the accuracy was within ±14.4% at concentrations of 5, 50, 500 and 5000 ng/mL for paclitaxel, 0.87, 8.7, 87 and 870 ng/mL for 6α‐hydroxypaclitaxel, and 0.87, 8.7, 87 and 435 ng/mL for p‐3′‐hydroxypaclitaxel. The total run time was 30 min. Our method was successfully applied to clinical pharmacokinetic investigation. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
A sensitive and specific LC-MS/MS assay for the quantitative determination of EO9 and its metabolite EO5a is presented. A 200-microl human plasma aliquot was spiked with a mixture of deuterated internal standards EO9-d3 and EO5a-d4 and extracted with 1.25 ml ethyl acetate. Dried extracts were reconstituted in 0.1 M ammonium acetate-methanol (7 : 3, v/v) and 25 microl-volumes were injected into the HPLC system. Separation was achieved on a 150 x 2.1 mm C18 column using an alkaline eluent (1 mM ammonium hydroxide-methanol (gradient system)). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range from 5 to 2500 ng/ml for EO9 and from 10 to 2500 ng/ml EO5a using 200 microl of human plasma samples. Validation results demonstrate that EO9 and EO5a concentrations can be accurately and precisely quantified in human plasma. This assay will be used to support clinical pharmacologic studies with EO9.  相似文献   

18.
A sensitive and selective method, using liquid chromatography-ionspray mass spectrometry, was developed and validated for the simultaneous determination of Estracyt (estramustine phosphate) and its four metabolites, estramustine, estromustine, estrone and estradiol, in human plasma. Deuterated internal standards were available for all analytes. The five compounds were extracted from plasma by protein precipitation with acetonitrile. The chromatographic separation was performed using a Zorbax SB C18, (150 x 4.6 mm i.d., 5 microm) reversed-phase column under gradient conditions with a mobile phase containing 2 mm ammonium acetate buffer (pH 6.8) and acetonitrile. MS detection was by electrospray ionization with multiple reaction monitoring in the positive ion mode for estramustine phosphate, estromustine and estramustine, and in the negative ion mode for estrone and estradiol. The limit of quantitation was 10 ng/mL for estramustine phosphate, 3 ng/mL for estromustine, estramustine and estrone and 30 ng/mL for estradiol. Linearity was verified from these LLOQs up to about 4000 ng/mL for the parent drug and 2000 ng/mL for the metabolites. Inter-day precision and accuracy values were all less than 15%. This assay was applied successfully to the routine analysis of human plasma samples collected in cancer patients administered estramustine phosphate intravenously.  相似文献   

19.
A rapid and selective liquid chromatography/tandem mass spectrometric method was developed for the simultaneous determination of capecitabine and its metabolites 5′‐deoxy‐5‐fluorocytidine (5′‐DFCR), 5′‐deoxy‐5‐fluorouracil (5′‐DFUR), 5‐fluorouracil (5‐FU) and dihydro‐5‐fluorouracil (FUH2) in human plasma. A 200 μL human plasma aliquot was spiked with a mixture of internal standards fludarabine and 5‐chlorouracil. A single‐step protein precipitation method was employed using 10% (v/v) trichloroacetic acid in water to separate analytes from bio‐matrices. Volumes of 20 μL of the supernatant were directly injected onto the HPLC system. Separation was achieved on a 30 × 2.1 mm Hypercarb (porous graphitic carbon) column using a gradient by mixing 10 mm ammonium acetate and acetonitrile–2‐propanol–tetrahydrofuran (1 : 3 : 2.25, v/v/v). The detection was performed using a Finnigan TSQ Quantum Ultra equipped with the electrospray ion source operated in positive and negative mode. The assay quantifies a range from 10 to 1000 ng/mL for capecitabine, from 10 to 5000 ng/mL for 5′‐DFCR and 5′‐DFUR, and from 50 to 5000 ng/mL for 5‐FU and FUH2 using a plasma sample of 200 μL. Correlation coefficients (r2) of the calibration curves in human plasma were better than 0.99 for all compounds. At all concentration levels, deviations of measured concentrations from nominal concentration were between ?4.41 and 3.65% with CV values less than 12.0% for capecitabine, between ?7.00 and 6.59% with CV values less than 13.0 for 5′‐DFUR, between ?3.25 and 4.11% with CV values less than 9.34% for 5′‐DFCR, between ?5.54 and 5.91% with CV values less than 9.69% for 5‐FU and between ?4.26 and 6.86% with CV values less than 14.9% for FUH2. The described method was successfully applied for the evaluation of the pharmacokinetic profile of capecitabine and its metabolites in plasma of treated cancer patients. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of sodium cromoglycate (SCG) in human plasma after a nasal dose of 10.4 mg sodium cromoglycate nasal spray, using pravastatin sodium as the internal standard. The method was validated over a linear range of 0.300-20.0 ng/mL. SCG and I.S. were extracted from 1.0 mL of heparinized plasma by C(18) solid-phase extraction cartridges using methanol as eluting solvent. The dried residue was reconstituted with 100 microL of mobile phase, and 10 microL was injected onto the LC-MS/MS system. Chromatographic separation was achieved on a C(18) column (250 x 4.6 mm i.d., 5 microm particle size) with a mobile phase of methanol-acetonitrile-water (containing 2 mmol/L ammonium acetate; 42.5:42.5:15, v/v/v) at a flow rate of 0.4 mL/min. The analytes were detected with a triple quad LC-MS/MS using ESI with positive ionization. Ions monitored in the multiple reaction monitoring mode were m/z 469.0 (precursor ion) to m/z 245.0 (product ion) for SCG and m/z 447.2 (precursor ion) to m/z327.1 (product ion) for pravastatin sodium (internal standard) The average recovery of SCG from human plasma was 94.88% and the lower limit of quantitation was 0.3 ng/mL. Results from a 3-day validation study demonstrated excellent precision and accuracy across the calibration range of 0.3-20 ng/mL. The method was successfully applied to the pharmacokinetic study of SCG in healthy Chinese volunteers. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号