1.
A sensitive and specific electrochemical immunosensor was developed with α‐fetoprotein (AFP) as the model analyte by using gold nanoparticle label for enzymatic catalytic amplification. A self‐assembled monolayer membrane of mercaptopropionic acid (MPA) was firstly formed on the electrode surface through gold‐sulfur interaction. Monoclonal mouse anti‐human AFP was covalently immobilized to serve as the capture antibody. In the presence of the target human AFP, gold nanoparticles coated with polyclonal rabbit anti‐human AFP were bound to the electrode via the formation of a sandwiched complex. With the introduction of goat anti‐rabbit IgG conjugated with alkaline phosphatase, the dentritical enzyme complex was formed through selective interaction of the secondary antibodies with the colloidal gold‐based primary antibody at the electrode, thus affording the possibility of signal amplification for AFP detection. Current response arising from the oxidation of enzymatic product was significantly amplified by the dentritical enzyme complex. The current signal was proportional to the concentration of AFP from 1.0 ng mL?1 to 500 ng mL?1 with a detection limit of 0.8 ng mL?1. This system could be extended to detect other target molecules with the corresponding antibody pairs.  相似文献   

2.
Present work demonstrates the fabrication of new and facile sandwich‐type electrochemical immunosensor based on palladium nanoparticles (PdNPs), polyaniline (PANI) and fullerene‐C60 nanocomposite film modified glassy carbon electrode (PdNP@PANI‐C60/GCE) for ultrasensitive detection of Prostate‐specific antigen (PSA) biomarker. PdNP@PANI‐C60 was electrochemically synthesized on GCE and used as an electroactive substrate. PdNP@PANI‐C60 was characterized by scanning electron microscopy (SEM), energy‐dispersive X‐ray spectroscopy (EDS), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Primary antibody anti‐PSA (Ab1) was covalently immobilized on PdNP@PANI‐C60/GCE using NHS/EDC linkers. In the presence of PSA antigen, horseradish peroxidase secondary antibody (HRP‐Ab2) was brought into the surface of the electrode, developing stable amplified signals of H2O2 reduction. Under the optimal conditions, a linear curve for determination of PSA at the proposed immunosensor was 1.6×10?4 ng.mL?1 to 38 ng.mL?1 with a limit of detection (LOD) of 1.95×10?5 ng.mL?1. The proposed immunosensor was successfully validated in serum and urine samples towards PSA detection with satisfactory and acceptable results.  相似文献   

3.
Calmodulin (CaM) is an important intracellular calcium‐binding protein. It plays a critical role in a variety of biological and biochemical processes. In this paper, a new electrochemical immunosensing protocol for sensitive detection of CaM was developed by using gold‐silver‐graphene (AuAgGP) hybrid nanomaterials as protein immobilization matrices and gold nanorods (GNRs) as enhanced electrochemical labels. Electrode was first modified with thionine‐chitosan film to provide an immobilization support for gold‐silver‐graphene hybrid nanomaterials. The hybrid materials formed an effective matrix for binding of CaM with high density and improved the electrochemical responses as well. Gold nanorods were prepared for the fabrication of enhanced labels (HRP‐Ab2‐GNRs), which provided a large capacity for HRP‐Ab2 immobilization and a facile pathway for electron transfer. With two‐step immunoassay format, the HRP‐Ab2‐GNRs labels were introduced onto the electrode surface, and produced electrochemical responses by catalytic reaction of HRP toward enzyme substrate of hydrogen peroxide (H2O2) in the presence of thionine. The proposed immunosensor showed an excellent analytical performance for the detection of CaM ranging from 50 pg mL?1 to 200 ng mL?1 with a detection limit of 18 pg mL?1. The immunosensor has also been successfully applied to the CaM analysis in two cancer cells (HepG2 and MCF‐7) with high sensitivity, which has shown great potency for improving clinic diagnosis and treatment for cancer study.  相似文献   

4.
Cystic echinococcosis (CE) or hydatid disease is a parasitic infection caused by Echinococcus granulosus. Early serodiagnosis and continuous monitoring of the disease is very important for medical treatment. Here, we report the detecting of both echinococcus antigen and antibody for the diagnosis of hydatid disease using square wave voltammetry (SWV)‐based immunosensors. The gold electrodes were functionalized using cysteamine/phenylene diisothiocyanate linkers and used for the immunosensors fabrication. The hydatid antigen and antibody immunosensors were constructed by the immobilization of either purified rabbit polyclonal antibody or recombinant antigen B (AgB), respectively on the functionalized gold electrodes surfaces. The detection in both cases was achieved by following the change in the SWV reduction peak current of the ferro/ferricyanide redox couple upon antibody or antigen binding. These immunosensors enabled the detection of echinococcus antigen and antibody within a concentration range of 1 pg.mL?1 to 1 μg.mL?1 with detection limits of 0.4 pg.mL?1 and 0.3 pg.mL?1, respectively. A preliminary application of the developed immunosensor was performed in spiked serum sample showing good recovery percentages ranging from 102 to 110 % for both hydatid antibody and antigen detection. This easy‐to‐use, sensitive, and low cost quantitative method holds great promise for the early diagnosis of hydatid disease and thus, better managements and treatment outcomes.  相似文献   

5.
A sensitive electrochemical immunosensor was developed for detecting fumonisin B1 (FB1) in corn using the single‐walled carbon nanotubes/chitosan. The detection mechanism of immunosensor was based on an indirect competitive binding to a fixed amount of anti‐FB1 between free FB1 and FB1‐bovine serum albumin, which was conjugated on covalently functionalized nanotubes/chitosan laid on the glass carbon electrode. The anti‐rabbit immunoglobulin G secondary antibody labeled with alkaline phosphatase was then bound to the electrode surface through reactisubstrate α‐naphthyl phosphate, which produced electrochemical signal. Under optimized conditions, this method could detect FB1 from 0.01 to 1000 ng mL?1 with a detection limit of 2 pg mL?1. This is well below the detection limit required from European Union legislation, 2–4 mg L?1. Moreover, good recoveries were obtained for the detection of spiked corn samples and actual corn samples. As the method has good sensitivity and recovery for detecting FB1, it is a practical detection method.  相似文献   

6.
In this work, a novel sandwich‐type electrochemical immunosensor with electroactive nickel hexacyanoferrate nanoparticles (NiHCFNPs) as matrix was constructed for α‐fetoprotein (AFP) detection in a signal‐off manner by using FeS2?AuNPs nanocomposite catalyzed insoluble precipitation to significantly inhibit the electrochemical signal. Initially, the NiHCFNPs with excellent electrochemical property was modified on the electrodeposited nano‐Au electrode to obtain a strong initial electrochemical signal. Subsequently, another nano‐Au layer was formed for immobilization of capture antibody (Ab1). In the presence of target AFP, the prepared FeS2?AuNPs‐Ab2 bioconjugate could be specifically recognized and immobilized on electrode through the sandwich‐type immunoreaction. The FeS2 with large specific surface areas were used as scaffolds to load abundant mimicking enzyme AuNPs. With the help of hydrogen peroxide (H2O2), FeS2?AuNPs with peroxidase‐like activity accelerated the 4‐chloro‐1‐naphthol (4‐CN) oxidation with generation of insoluble precipitation on electrode, which would greatly hinder the electron transfer and thus caused the decrease of electrochemical signal for quantitative determination of AFP. This approach achieved a wide dynamic linear range from 0.0001 to 100 ng mL?1 with an ultralow limit detection of 0.028 pg mL?1. Especially, the proposed AFP immunosensor can be applied to detect human serum samples with satisfactory results, indicating a potential application in clinical monitoring of tumor biomarkers.  相似文献   

7.
本文研制了一种用金胶壳聚糖仿生膜来同时固定四甲基联苯胺(TMB)和酶标抗体的新型电化学免疫传感器,用于检测血清肿瘤标志物前列腺特异性抗原(PSA)的含量。固定的TMB作为电子传递媒介体,在扫速小于45 mV/s时,电极表现为一个表面控制过程,而在扫速大于45 mV/s时则表现为一个扩散控制过程。将固定有酶标抗体和TMB的免疫传感器与待测PSA抗原一起培育,在该传感器上形成的免疫复合物通过TMB-H2O2-HRP电化学体系进行了测定。在优化实验条件下,PSA的线性检测范围为5-30 ng·mL-1,检测限为1.0 ng·mL-1。该PSA免疫传感器制备方法简单,成本低廉,具有较好的稳定性和重现性。  相似文献   

8.
《Electroanalysis》2018,30(5):819-827
Microcystins are potent hepatotoxins produced by cyanobacteria, which proliferate in wastewaters with high nutrient content. Due to their high toxicity and potential risk to human health, even at low concentrations, the development of a sensitive and rapid method for the monitoring of microcystin‐LR (MC‐LR) in water samples is of great importance. In this context, a new direct electrochemical nano‐immunosensor for MC‐LR detection using the liquid crystal (E)‐1‐decyl‐4‐[(4‐decyloxyphenyl)diazenyl]pyridinium bromide (Br‐Py) as a redox probe and gold nanoparticles stabilized in bovine serum albumin (AuNP‐BSA) is described herein. The microcystin‐LR antibody (anti‐MC‐LR) was covalently immobilized using N‐(3‐dimethylaminopropyl)‐N‐ethylcarbodiimide hydrochloride (EDC) and N‐hydroxysuccinimide (NHS) on an AuNP‐BSA/BrPy film. The proposed sensor response is based on the inhibition of the Br‐Py electrochemical signal after the specific interaction of MC‐LR with immobilized anti‐MC‐LR on the electrode surface. The electrochemical behavior of the immunosensor was studied by square‐wave voltammetry (SWV) and electrochemical impedance spectroscopy (EIS). Under optimized conditions, using SWV and an incubation time of 15 min, the immunosensor exhibits a linear response to MC‐LR concentrations of 0.05 to 500.0 ng mL−1 with a detection limit of 0.05 ng mL−1. The anti‐MC‐LR/AuNP‐BSA/Br‐Py/GCE was successfully applied in the determination of MC‐LR in spiked seawater samples.  相似文献   

9.
In this paper, a thiol graphene‐thiol chitosan‐gold nanoparticles (thGP‐thCTS‐AuNPs) nanocomposites film with porous structure was fabricated by electrochemically depositing on glassy carbon electrode (GCE), which exhibited good biocompatibility and improved conductivity, to construct immunosensor free label for detection of carcinoembryonic antigen (CEA). The electrochemical behavior of this immunosensor was investigated by cyclic voltammetry. Under the optimum conditions, the immunosensor revealed a good amperometric response to CEA in two linear ranges (0.3–8.0 ng mL?1 and 8.0–100 ng mL?1) with a detection limit of 0.03 ng mL?1. The results indicated that the immunosensor has the advantages of good selectivity, high sensitivity, and good stability for the determination of CEA.  相似文献   

10.
In the present study, we developed a novel label‐free capacitance impedimetric immunosensor based on the immobilization of the human monoclonal antibody anti‐interleukin‐10 (anti‐IL‐10 mAb) onto polypyrrole (PPy)‐modified silicon nitride (Si3N4) substrates. The immunosensor was used for the detection of the recombinant interleukin‐10 antigen (rh IL‐10) that may be secreted in patients at the early stage of inflammation. The immunosensor was created by chemical deposition of PPy conducting layer on pyrrole?silane (SPy)‐treated Si/SiO2/Si3N4 substrates (Si/SiO2/Si3N4?SPy), followed by anti‐IL‐10 mAb immobilization through carboxyl‐functionalized diazonium (CMA) protocol and carbodiimide chemistry. The surface characterization and the biofunctionalization steps were characterized by SEM, FTIR and cyclic voltammetry (CV) while the detection process was carried out by using electrochemical impedance spectroscopy (EIS) analyses. The created immunosensor showed two linear fittings (R2=0.999) for the detection of rh IL‐10 within the concentration range from 1–50 pg/mL. It exhibited high sensitivity (0.1128 (pg/mL)?1) with a very low limit of detection (LOD)=0.347 pg/mL, more particularly, at the low concentration range (1–10 pg/mL). Thus, this developed polypyrrole‐based immunosensor represents a promising strategy for creation of miniaturized label‐free, fast and highly sensitive biosensors for diagnosis of inflammation biomarkers at very low concentrations with reduced cost.  相似文献   

11.
This paper reports results obtained when comparing an electrochemical enzyme immunosensor and a surface plasmon resonance (SPR) based immunosensor on the same gold surface installed in an electrochemical SPR flow cell. Simultaneous electrochemical and SPR measurements were performed on a gold surface modified with multilayers of poly‐L ‐lysine and poly‐styrenesulfonate assembled with the layer‐by‐layer method. First, we obtained the SPR response induced by the formation of an immunocomplex from the shift in the SPR angle by injecting an anti tumor necrosis factor‐α antibody solution labeled with alkaline phosphatase into the flow cell containing the multilayer modified with tumor necrosis factor‐α. Then we compared this SPR result with that obtained for the electrochemical oxidation current of p‐aminophenol catalyzed by alkaline phosphatase from p‐aminophenolphosphate on the same gold film. We compared the two immunosensor responses obtained using the different measurement principles and found that there was a high correlation efficient of 0.973 between them. This was because we were able to immobilize the immunoreagents with good stability and without losing the transport of the enzyme product in the multilayer whose thickness we easily controlled with nanometer scale accuracy. We also report that the detection limit of our electrochemical immunosensor after optimization was around 100 pg/mL (0.4 pM), which is one of the lowest values yet reported for an electrochemical immunosensor.  相似文献   

12.
A novel magnetoimmunosensor, designed for sensitive and selective quantification of interleukin 6, is herein reported. The experimental design involves the covalent immobilization of anti‐interleukin 6 antibody through an amidic bond formed with the carboxyl functionalities provided at the surface of protein G‐functionalized magnetic microparticles, assuring a sandwich‐type immunoassay with electrochemical label free detection. All the experimental parameters involved in the elaboration and testing protocol were optimized. A linear calibration plot between the charge transfer resistance and the logarithmic concentration of interleukin‐6 was achieved in the 1 pg mL?1 to 1 μg mL?1 range. A limit of quantification of 1 pg mL?1 and a detection limit of 0.3 pg mL?1 were obtained. The optimized magnetoimmunosensor showed an excellent selectivity against some potentially interfering proteins and has been successfully applied for the determination of target protein in human serum, proving its clinical relevance.  相似文献   

13.
In this study, electrochemical immunosensors were developed for the detection of prostate specific antigen (PSA) using ferrocene (Fc) and polyamidoamine dendrimer (PAMAM) constructs. The biosensor fabrication was designed by modifying the screen‐printed gold electrode (Au) with ferrocene cored dendrimers (FcPAMAM) synthesized in three different generations. The self‐assembled monolayer principle was followed, to obtain sensitive, selective and disposable electrodes. Therefore, the Au electrodes were modified with cysteamine (Cys) to obtain a functional surface for FcPAMAM dendrimers to bind. Dendrimer generations were attached to this surface using a cross‐linker (glutaraldehyde) so that a suitable surface was obtained for binding of biological components. The Monoclonal PSA antibody (anti‐PSA) was immobilized on the Au electrode surface which coated with dendrimer, and (Au/Cys/FcPAMAM/anti‐PSA) biosensing electrode was obtained. The PSA detection performances of electrochemical impedance spectroscopy (EIS) and Amperometry based immunosensors exhibited very low detection limits; 0.001 ng mL?1 and 0.1 pg mL?1, respectively. In addition, EIS and Amperometry based biosensors using Au/Cys/FcPAMAM/anti‐PSA sensing electrode were represented excellent linear ranges of 0.01 ng mL?1 to 100 ng mL?1 and 0.001 ng mL?1 to 100 ng mL?1. In order to determine the applicability recovery and selectivity tests were performed using three different proteins in human serum.  相似文献   

14.
A simple, highly sensitive and label‐free electrochemical impedance spectroscopy (EIS) immunosensor was developed using Nafion and gold nanoparticles (nano‐Au/Nafion) composites for the determination of 1‐pyrenebutyric acid (PBA). Under the optimal conditions, the amount of immobilized antibody was significantly improved on the nano‐Au/Nafion electrode due to the synergistic effect and biocompatibility of Nafion film and gold nanoparticles composites. The results showed that the sensitivity and stability of nano‐Au/Nafion composite electrode for PBA detection were much better than those of nano‐Au modified glassy carbon electrode (nano‐Au/GCE). The plot of increased electron transfer resistances (Rets) against the logarithm of PBA concentration is linear over the range from 0.1 to 150 ng·mL?1 with the detection limit of 0.03 ng·mL?1. The selectivity and accuracy of the proposed EIS immunosensor were evaluated with satisfactory results.  相似文献   

15.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

16.
Fluorescent gold nanoclusters (AuNCs) were incorporated into porous calcium carbonate spheres through electrostatic interaction. The resulting CaCO3/AuNCs hybrid material exhibited interesting properties, such as porous structure, excellent biocompatibility, good water solubility, and degradability. These properties make the CaCO3/AuNCs hybrid material a promising template to assemble horseradish peroxidase/antibody conjugates (HRP‐Ab2). By using CaCO3/AuNCs/HRP‐Ab2 bioconjugates as probes, a versatile immunosensor was developed for fluorescent and electrochemical detection of the cancer biomarker neuron‐specific enolase (NSE). The detection limits of the sensor were 2.0 and 0.1 pg mL?1 for fluorescent and electrochemical detection, respectively. The immunosensor shows high sensitivity and offers an alternative strategy for the detection of other proteins and DNA.  相似文献   

17.
The electrochemical immunosensor for α‐fetoprotein (AFP) was fabricated based on the platform of gold nanoparticles (GNP)/graphene (Gr)‐prussian blue (PB). By electrodeposition, GNP were modified on the surface of the prepared Gr‐PB. The anti‐AFP‐1,1′‐ferrocenedicarboxylic acid (FcDA) as label was directly immobilized on the platform of GNP/Gr‐PB. And after the immunoreactions, the formed complex inhibited the electron transfer and decreased the catalytic current of FcDA toward the reduction of H2O2. And in the range of 10–3200 pg·mL?1, the decreased current is linear with the concentration of AFP, with a detection limit of 3 pg·mL?1. The developed immunoassay method showed good precision, high sensitivity, acceptable stability and reproducibility, and could be used for the detection of real samples with consistent results in comparison with those obtained by the enzyme linked immunosorbent assay (ELISA) method.  相似文献   

18.
A strategy for a fast (ca. 20 min), specific, electrochemical immunoassay for the cardiac biomarker creatine kinase (CK) and the human cytokine interleukin 10 (IL10) has been developed in this paper. The polyaniline modified gold surface formed from electrochemical reduction of diazonium salt supplies a solid substrate to link the activated carboxylic acid groups from the antibodies, which were labelled with ferrocene. The direct electrochemistry of ferrocene allows the analysis of protein markers with good sensitivity. The creatine kinase sensor demonstrates limit of detection of 0.5 pg mL?1 in a physiological Krebs‐Henseleit solution. The anti‐IL10 antibody retained fluorescence activity after further coupling to ferrocene and covalent immobilization on to a gold electrode, showing a linear detection range for IL‐10 from 0.001 ng mL?1 to 50 ng mL?1 in PBS. We attribute the high sensitivity to the well‐controlled modified surface which results in end–on antibodies that can specifically capture the antigen with ease.  相似文献   

19.
《Electroanalysis》2006,18(10):1007-1013
A highly hydrophilic and nontoxic colloidal silica nanoparticle/titania sol–gel composite membrane was prepared on a gold electrode via a chemical vapor deposition method. With carcinoembryonic antigen (CEA) as a model antigen and encapsulation of carcinoembryonic antibody (anti‐CEA) in the composite architecture, this membrane could be used for reagentless electrochemical immunoassay. The presence of silica nanoparticles provided a congenial microenvironment for adsorbed biomolecules. The formation of immunoconjugate by a simple one‐step immunoreaction between CEA in sample solution and the immobilized anti‐CEA introduced the change in the potential. The modified procedure was further characterized by electrochemical impedance spectroscopy and cyclic voltammetry. Compared to the commonly applied methods, i.e., the TiO2 direct embedding procedure, this strategy could allow for antibodies immobilized with higher loading amount and better retained immunoactivity. The resulting immunosensor exhibited high sensitivity, good precision, acceptable stability, accuracy, reproducibility and wide linear range from 1.5 to 240 ng mL?1 with a detection limit of 0.5 ng mL?1 at 3σ. Analytical results of clinical samples show that the developed immunoassay is comparable with the enzyme‐linked immunosorbent assays (ELISAs) method, implying a promising alternative approach for detecting CEA in the clinical diagnosis. Furthermore, this composite membrane could be used efficiently for the entrapment of other biomarkers and clinical applications.  相似文献   

20.
A signal‐enhanced immunosensor has been developed by self‐assembling Au NPs onto a ferrocene‐branched poly(allylamine)/multiwalled carbon nanotubes (PAA‐Fc/MWNTs) modified electrode for the sensitive determination of hepatitis B surface antigen (HBsAg) as a model protein. The formation of PAA‐Fc/MWNTs composite not only effectively avoided the leakage of Fc and retained its electrochemical activity, but also enhanced the conductivity and charge‐transport properties of the composite. Further adsorption of Au NPs into the PAA matrix provided both the interactive sites for the immobilization of hepatitis B surface antibody (HBsAb) and a favorable microenvironment to maintain its activity. Tests performed with this immunosensor showed a specific response to HBsAg in the range of 0.1–350.0 ng mL?1 with a detection limit of 0.03 ng mL?1.  相似文献   