1.
A carbon paste electrode (CPE) was modified by incorporation of graphene nano sheets and a ferrocene derivative. The modified electrode showed an excellent electrocatalytic effect on the oxidation of epinephrine. In phosphate buffer solution (PBS) of pH 7.0, the oxidation current increased linearly with concentration of epinephrine in the range of 0.05–550.0 µM and a detection limit (3σ) 27.0 nM was obtained for epinephrine. Then the modified electrode was used to determine epinephrine in an excess of uric acid and folic acid by SWV.  相似文献   

2.
A carbon‐paste electrode modified with 2,7‐bis(ferrocenyl ethyl)fluoren‐9‐one and carbon nanotubes was used for the sensitive voltammetric determination of levodopa (LD). The electrochemical response characteristics of the modified electrode toward LD, uric acid (UA) and folic acid (FA) were investigated. The results showed an efficient catalytic activity of the electrode for the electrooxidation of LD, which leads to lowering its overpotential by more than 320 mV. The modified electrode exhibits an efficient electron mediating behavior together with well‐separated oxidation peaks for LD, UA and FA. Also, the modified electrode was used for determination of LD in some real samples.  相似文献   

3.
A modified electrode was prepared by modification of the carbon paste electrode (CPE) with a nanostructured material. This nanostructure with electrocatalytic activity was synthesized by combination of poly pyrrole and copper oxide nanoparticles (PPy/CuO). The structure and morphology of PPy/CuO was studied. The fabricated modified electrode (CPE‐PPy/CuO) exhibited an excellent electrocatalytic activity toward levodopa (L‐DOPA) and uric acid (UA) oxidation because of high conductivity, low electron transfer resistance and catalytic effect. The CPE‐PPy/CuO had a lower overvoltage and enhanced electrical current with respect to the bare CPE for both L‐DOPA and UA. Also, the modified electrode showed a good resolution for the overlapped anodic peaks of L‐DOPA and UA. This electrode was used for the successful simultaneous determination of L‐DOPA and UA. The electrochemical sensor responded to L‐DOPA and UA in the concentration range of 0.050–1200 μM and 0.040–2000 μM, respectively. The detection limits were obtained by differential pulse voltammetry as 15 nM for L‐DOPA and 20 nM for UA. Finally, the proposed electrode was used for determination of L‐DOPA and UA in real samples using standard addition method.  相似文献   

4.
《Analytical letters》2012,45(16):2618-2630
A carbon paste electrode (CPE), modified with novel hydroquinone/TiO2 nanoparticles, was designed and used for simultaneous determination of ascorbic acid (AA), uric acid (UA) and folic acid (FA). The magnitude of the peak current for modified TiO2-nanoparticle CPE (MTNCPE) increased sharply in the presence of ascorbic acid and was proportional to its concentration. A dynamic range of 1.0–1400.0 μM, with the detection limit of 6.4 × 10?7 M for AA, was obtained using the DPV technique (pH = 7.0). The prepared electrode was successfully applied for the determination of AA, UA, and FA in real samples.  相似文献   

5.
A simple differential pulse voltammetric method based on a graphite paste electrode (GPE) was developed for the quantitative determination of folic acid (FA) in tablets. The electrode exhibits a clear improvement of the current response. A linear response in the electroanalytical approach exists from 4.97×10?6 to 2.94×10?5 mol L?1 with a limit of detection of about 2.67×10?6 mol L?1 in KCl solutions. The developed procedure was tested by recovery studies and compared with spectrophotometric and chromatographic methods. The results are described and discussed in the light of existing literature.  相似文献   

6.
《Electroanalysis》2018,30(5):803-809
An electrode modified with ZnS and gold nanoparticles (Au‐ZnS NPs) is introduced for highly sensitive voltammetric determination of ganciclovir (GCV). Surface structure and topography of the modified electrode was studied by SEM, EDX and XRD techniques. Electrochemical oxidation of GCV was investigated by cyclic (CV) and square wave voltammetry (SWV) in Briton‐Robinson buffer solution (pH 1.5). The results showed that electrochemical oxidation of GCV at the Au‐ZnS modified glassy carbon electrode (GCE) is irreversible and exhibited diffusion controlled electrode process over the pH range from 1.0 to 6.0. The oxidation potential peak and pH relationship showed that electrons and protons were transferred simultaneously over the electrochemical oxidation process. Using the proposed sensor, the linear calibration curves were obtained in the ranges of 0.04–1.50 μM and 1.5–70.0 μM with detection limit of 0.01 μM GCV by SWV technique. The modified electrode was successfully applied as a sensitive, reproducible and repeatable sensor for determination of the trace amount of GCV in human serum, urine and cymevene vials. Reasonable results were obtained from comparing the measurements of the real samples by the new sensor to high performance liquid chromatography (HPLC) as a standard method.  相似文献   

7.
In this study, a carbon paste electrode modified with (E)‐2‐((2‐chlorophenylimino)methyl)benzene‐1,4‐diol (CD) and titanium dioxide nanoparticles (TiO2) was used to prepare a novel electrochemical sensor. The objective of this novel electrode modification was to seek new electrochemical performances for the detection of isoproterenol (IP) in the presence of acetaminophen (AC) and folic acid (FA). Initially, cyclic voltammetry (CV) was used to investigate the redox properties of this modified electrode at various scan rates. In the following, the mediated oxidation of IP at the modified electrode was described. The results showed an efficient catalytic activity of the electrode for the electrooxidation of IP, which leads to a reduction in its overpotential by more than 235 mV. The value of the electron transfer coefficient (α), catalytic rate constant (kh) and diffusion coefficient (D) were calculated for IP, using electrochemical approaches. Based on differential pulse voltammetry (DPV), the oxidation of IP exhibited a dynamic range between 0.5 and 1000 µM and a detection limit (3σ) of 0.47 µM. DPV was used for simultaneous determination of IP, AC and FA at the modified electrode. Finally, this method was used for the determination of IP in real samples, using standard addition method.  相似文献   

8.
《Electroanalysis》2005,17(22):2043-2051
The electrochemical behavior of L ‐cysteine studied at the surface of ferrocenecarboxylic acid modified carbon paste electrode (FCMCPE) in aqueous media using cyclic voltammetry and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteine is occurs at a potential about 580 mV less positive than that an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and catalytic reaction rate constant, Kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L ‐cysteine showed a linear dependent on the L ‐cysteine concentration and linear calibration curves were obtained in the ranges of 10?5 M–10?3 M and 4.1×10?8 M–3.7×10?5 M of L ‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (2δ) were determined as 2.4×10?6 M and 2.5×10?8 M by CV and DPV methods. This method was also examined for determination of L ‐cysteine in some samples, such as Soya protein powder, serum of human blood by using recovery and standard addition methods.  相似文献   

9.
Bismuth nanostructure‐carbon ionic liquid electrode has been employed for sensitive determination of cysteine (Cys). Bismuth nanostructure was incorporated into the carbon ionic liquid electrode (CILE) and applied for determination of cysteine. An interaction was taking place between bismuth nanostructure and the thiol group of cysteine. The bismuth cysteinate complex oxidation potential occurred at more negative potential compared to the cysteine oxidation peak obtained at bare carbon ionic liquid electrode (CILE). Square wave voltammetry (SWV) was used for the determination of the cysteine and satisfactory results were obtained. The calibration curve was linear in the concentration range of 1 to 500 µM and 0.5–2 mM of Cys. A low detection limit of 0.5 µM was achieved for Cys. The electrode showed a good selectivity for determination of cysteine in the presence of other amino acids. The proposed electrode was satisfactory applied for the determination of cysteine in human serum plasma sample.  相似文献   

10.
By exploiting the electrostatic interaction between positively charged 3,4‐ethylenedioxythiophene cation radicals and negatively charged sulfonated graphene (SG) sheets, we prepared a poly(3,4‐ethylenedioxythiophene)‐sulfonated graphene (SG‐PEDOT) composite film by a one‐step electrochemical process. The composite was further decorated with gold nanoparticles (AuNPs) and employed as an electrode material for the detection of L ‐cysteine (Cys). The SG‐PEDOT composite film is shown to provide a rough surface for the electrodeposition of AuNPs and to improve substrate accessibility and interaction with Cys. Moreover, the AuNPs‐decorated composite exhibits better electrocatalytic performance than that of a SG‐PEDOT composite only. Under optimum experimental conditions, the amperometric current of the sensor is linearly related to the concentration of Cys in the 0.1 to 382 µM range, and the detection limit is 0.02 µM (at S/N=3). The modified electrode displays favorable selectivity, good stability and high reproducibility. The method was successfully applied to the detection of Cys in spiked human urine.  相似文献   

11.
The surface of a gold (Au) disk electrode was modified with a self‐assembled monomolecular layer of dithiobis(4‐butylamino‐m‐phenylboronic acid) (DTBA‐PBA) to prepare L ‐lactate‐sensitive electrodes. The DTBA‐PBA‐modified electrodes exhibited an attenuated cyclic voltammogram (CV) for the Fe(CN)63? ion in the presence of L ‐lactate, as a result of the formation of phenylboronate ester of L ‐lactate accompanied with the addition of OH? ion to the boron atom. In other words, the negatively charged DTBA‐PBA monolayer blocked the electrode surface from the access of the Fe(CN)63?/4? ions. Thus, the DTBA‐PBA monolayer‐modified Au electrode can be used for determining L ‐lactate on the basis of the change in redox current of Fe(CN)63?/4? ions. The calibration graph useful for determining 1–30 mM L ‐lactate was obtained.  相似文献   

12.
This work presents a sensitive voltammetric method for determination of folic acid by adsorbing methylene blue onto electrodeposited reduced graphene oxide film modified glassy carbon electrode (MB/ERGO/GCE) in 100 mM KCl‐10 mM sodium phosphate buffer solution (pH 7.40). The surface morphology of the MB/ERGO/GCE modified electrode was characterized using scanning electron microscopy, displays that both MB and ERGO distributed homogeneously on the surface of GCE. The MB/ERGO/GCE modified electrode shows more favorable electron transfer kinetics for potassium ferricyanide and potassium ferrocyanide probe molecules, which are important electroactive compounds, compared with bare GCE, MB/GCE, and ERGO/GCE. The electrochemical behaviors of folic acid at MB/ERGO/GCE were investigated by cyclic voltammetry, suggesting that the modified electrode exhibited excellent electrocatalytic activity towards folic acid compared with other electrodes. Under physiological condition, the MB/ERGO/GCE modified electrode showed a linear voltammetric response from 4.0 μM to 167 μM for folic acid, and with the detection limit of 0.5 μM (S/N=3). The stability, reproducibility and anti‐interference ability of the modified electrode were examined. The developed method has been successfully applied to determination of FA in tablets with a satisfactory recovery from 96 % to 100 %. The work demonstrated that the electroactive MB adsorbing onto graphene modified electrode showed an enhanced electron transfer property and a high resolution capacity to FA.  相似文献   

13.
《Electroanalysis》2005,17(7):619-624
The electrocatalytic oxidation of L ‐cysteine by (ferrocenylmethyl)trimethylammonium at a glassy carbon electrode in 0.1 M Na2SO4 aqueous solution has been studied. The rate constant for the catalytic reaction was evaluated as (4.28±0.05)×103 M?1 s?1 by chronoamperometry. Experimental conditions, which maximize the current efficiency of the electrocatalytic oxidation, such as pH value and the concentration of the catalyst, were also investigated. The experimental results of electrocatalytic kinetics of L ‐cysteine oxidation on GCE in the presence of (ferrocenylmethyl)trimethylammonium obviously support the reaction mechanism proposed and the rate determining step assumed in scheme described in this work.  相似文献   

14.
The electrosynthesis of polypyrrole (PPy) film has been achieved on glassy carbon electrode (GCE) in aqueous medium of Congo red (CR) by means of cyclic voltammetry (CV). The modified electrode exhibits high electrocatalytic activity toward dopamine (DA) oxidation, with drastic enhancement of the reversibility and peak currents. This modified electrode, due to electrostatic interactions, is capable to mask the response of ascorbic acid (AA) completely and provide an effective method for the detection of minor amounts of dopamine in the presence of high concentrations of AA. The electrochemical response of the film modified electrode is strongly dependent to the switching potential applied in the CV procedure of the electro‐polymerization. The results show that by increasing the switching potential more than 0.75 V, the peak of AA is gradually disappeared. This peak in potential of 0.85 V is reached to capacitive background current. With respect to the destruction of the conjugated structure of ppy and lowering the conductivity of the film at the surface of modified electrode, higher switching potentials cannot be suitable for electropolymerization procedure. The effects of various experimental parameters such as, number of polymerization cycles, switching potential, pH and potential sweep rate on the voltammetric response of dopamine were also investigated. The modified electrode shows a linear response to DA in the range of 0.5 to 100 μM with a detection limit of 0.1 μM. The prepared modified electrode does not show any considerable response toward sulfhydryl compounds, such as, cysteine, penicillamine and glutathione, revealing a good selectivity for voltammetric response to DA. The effective electrocatalytic property, ability for masking the voltammetric responses of the other biological reducing agents together with high reproducibility and stability make the modified electrode suitable for selective and sensitive voltammetric detection of sub‐micromolar amounts of DA in clinical and pharmaceutical preparations.  相似文献   

15.
A fullerene‐C60‐modified gold electrode is employed for the determination of dopamine in the excess of ascorbic acid using square‐wave voltammetry. Based on its strong catalytic function towards the oxidation of dopamine and ascorbic acid, the overlapping voltammetric response of both the biomolecules at the bare electrode is resolved into two well‐defined voltammetric peaks with lowered oxidation potential and enhanced oxidation currents. Linear calibration curves for dopamine are obtained using square‐wave voltammetry over the concentration range 1 nM–5.0 μM in 0.1 M phosphate buffer solution at pH 7.2 with a correlation coefficient of 0.9931 and the detection limit (3σ) is estimated to be 0.26×10?9 M. The interference studies showed that the presence of physiologically common interferents (i.e. uric acid, citric acid, tartaric acid, glucose and sodium chloride) negligibly affects the response of dopamine. The practical analytical utility of the method is illustrated by quantitative determination of dopamine in commercially available pharmaceutical formulation and human body fluids, viz. urine and blood plasma, without any preliminary treatment.  相似文献   

16.
The electrochemical behavior of L ‐cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation of L ‐cysteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L ‐cysteine showed a linear dependent on the L ‐cysteine concentration and linear analytical curves were obtained in the ranges of 3.0×10?5 M–2.2×10?3 M and 1.5×10?5 M–3.2×10?3 M of L ‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 2.6×10?5 M and 1.4×10?6 M by CV and DPV methods.  相似文献   

17.
《Electroanalysis》2003,15(20):1625-1631
This article describes the formation of a SAM with chemisorbed cysteine to a gold surface by the thiol group to obtain a surface electrode with an amino and an acid group free for later reaction and accumulation with other molecules on the electrode surface. We explore the accumulation of unsaturated fatty acid and the electrochemical response of the electrode after modification with cysteine. The electrochemical study confirmed the accumulation of linoleic acid on the modified electrode. The optimum conditions for the determination of linoleic acid by differential pulse voltammetry of linoleic acid are studied a detection limit (3σ) of 0.03 μg mL?1 and a determination limit (10σ) of 0.10 μg mL?1 were obtained and applied to determination in olive oil and ham from Iberian breed hams.  相似文献   

18.
《Electroanalysis》2005,17(20):1835-1840
An L ‐cysteine modified gold electrode for the determination of copper in the presence of various amounts of arsenic with anodic stripping voltammetry has been studied. The electrode was fabricated by immersing a gold electrode in an ethanol solution of 5mM L ‐cysteine for 60 min. Various parameters, such as the effect of different supporting electrolytes, the pH of the electrolyte and the deposition potential were investigated. Under optimum conditions, copper was accumulated at ?0.3 V (vs. SEC) for 60 s in 0.1 M phosphate buffer pH 5.0 in the presence of different amounts of arsenic. Essentially the same sensitivities (0.33±0.001 μA/μM) and limits of detection (0.13±0.002 μM) of copper were obtained with various amount of arsenic in the range 2 μM to 20 μM.  相似文献   

19.
This paper describes the development a novel ruthenium(II) complex‐ZnO/CNTs modified carbon paste electrode (Ru(II)/ZnO/CNTs/CPE) for the electrocatalytic determination of ascorbic acid (AA). The objective of this novel electrode modification was to seek new electrochemical performances for the detection of AA, nicotinamide adenine dinucleotide (NADH) and folic acid (FA). The peak potentials recorded were 170, 500 and 830 mV vs. Ag/AgCl/KClsat for AA, NADH and FA, respectively. The peak currents were linearly dependent on AA, NADH and FA concentrations using square wave voltammetry (SWV) method at the ranges of 0.008–251, 1.0–650, and 3.0–700 µmol L?1, with detection limits of 0.005, 0.5, and 1.0 µmol L?1, respectively.  相似文献   

20.
建立了高效液相色谱法测定叶酸片中叶酸含量的方法。采用Symmetry C18色谱柱(150×4.6mm,3.5μm),以磷酸盐缓冲溶液(PBS,pH=6.3)为流动相,检测波长254nm,柱温35℃。叶酸在0.04~0.36μg/mL范围线性良好(r=0.9999),平均加标回收率为99.4%(RSD=0.44%)。该方法简便准确,精密度良好,适用于叶酸片中叶酸含量的测定。  相似文献   