首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present study describes a novel and very sensitive electrochemical assay for determination of hydrogen peroxide (H2O2) based on synergistic effects of reduced graphene oxide‐ magnetic iron oxide nanocomposite (rGO‐Fe3O4) and celestine blue (CB) for electrochemical reduction of H2O2. rGO‐Fe3O4 nanocomposite was synthesized and characterized by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), X‐ray diffraction (XRD), electrochemical impedance spectroscopy and cyclic voltammetry. Chitosan (Chit) was used for immobilization of amino‐terminated single‐stranded DNA (ss‐DNA) molecules via a glutaraldehyde (GA) to the surface of rGO‐Fe3O4. The MTT (3‐(4,5‐Dim ethylt hiazol‐2‐yl)‐2,5‐diphenylt etrazolium bromide) results confirmed the biocompatibility of nanocomposite. Experimental parameters affecting the ss‐DNA molecules immobilization were optimized. Finally, by accumulation of the CB on the surface of the rGO‐Fe3O4‐Chit/ssDNA, very sensitive amperometric H2O2 sensor was fabricated. The electrocatalytic activity of the rGO‐Fe3O4‐Chit/DNA‐CB electrode toward H2O2 reduction was found to be very efficient, yielding very low detection limit (DL) of 42 nM and a sensitivity of 8.51 μA/μM. Result shows that complex matrices of the human serum samples did not interfere with the fabricated sensor. The developed sensor provided significant advantages in terms of low detection limit, high stability and good reproducibility for detection of H2O2 in comparison with recently reported electrochemical H2O2 sensors.  相似文献   

2.
We present a new strategy for the label‐free electrochemical detection of DNA hybridization based on gold nanoparticles (AuNPs)/poly(neutral red) (PNR) modified electrode. Probe oligonucledotides with thiol groups at the 5‐end were covalently linked onto the surface of AuNPs/PNR modified electrode via S‐Au binding. The hybridization event was monitored by using differential pulse voltammetry (DPV) upon hybridization generates electrochemical changes at the PNR‐solution interface. A significant decrease in the peak current was observed upon hybridization of probe with complementary target ssDNA, whereas no obvious change was observed with noncomplementary target ssDNA. And the DNA sensor also showed a high selectivity for detecting one‐mismatched and three‐mismatched target ssDNA and a high sensitivity for detecting complementary target ssDNA, the detection limit is 4.2×10?12 M for complementary target ssDNA. In addition, the DNA biosensor showed an excellent reproducibility and stability under the DNA‐hybridization conditions.  相似文献   

3.
4.
A novel highly sensitive electrochemiluminescence (ECL) detection protocol for mercury(II) ions was developed. Based on the strong and stable thymine? thymine mismatches complexes coordination chemistry, mercury(II) ions can specifically bind to a designed DNA strand, leading to the release of the complimentary DNA strand. The released DNA strand was then captured by magnetic beads modified with specific DNA, and then through the formation of DNA‐linked luminol‐Au nanoparticles (NPs) superstructure, a specific ECL system for mercury(II) ions was developed. Using 3‐aminopropyl‐triethoxysilane as an effective enhancer, the ECL system can detect Hg2+ ion within a linear range from 2.0×10?10 mol L?1 to 2.0×10?8 M, with a detection limit as low as 1.05×10?10 M (3σ). Moreover, this ECL system is highly specific for Hg2+, without interference from other commonly coexisted metal ions, and it can be used for the analysis of real samples.  相似文献   

5.
《Electroanalysis》2018,30(2):288-295
Methotrexate (MTX) was used as an anti‐cancer drug, but its excessive use can cause serious side effects, it was necessary to monitor MTX in vivo. In this report, DNA was immobilized on a glassy carbon electrode (GCE) modified with graphene oxide (GO) to develop an electrochemical sensor for sensitive determination of MTX for the first time. The adsorptive voltammetric behaviors of MTX on DNA sensor were investigated using differential pulse voltammetry (DPV). The peak current response of guanine in DNA was used as a determination signal of MTX in acetate buffer solution pH 4.6. Voltammetric investigations revealed that the proposed method could determine MTX in the concentration range from 5.5×10−8 to 2.2×10−6 mol L−1 with a lower detection limit of 7.6×109 mol L−1 (S/N=3). The method was applied to detect MTX in human blood serum and diluted urine samples with excellent recoveries of 97.4–102.5 %. Compared with the previous studies, the DNA/GO/GCE electrode constructed by us based on the change rate of guanine current (R%) in DNA, proportionally reflecting the MTX concentration, is simple and sensitive .  相似文献   

6.
Presently, bisphenol A (BPA) has been added to the list of substances of very high concern as endocrine disruptors. According to the literature, exposure to bisphenol A even at low doses may result in adverse health effects. In this study, electrochemical sensor of Bisphenol A based on thioether DDT‐Poly(N‐vinylpyrrolidone) oligomer has been developed. The thioether oligomer, which is capable of recognizing BPA, was prepared and used for gold electrode modification. The characterization of the modified gold electrode and the synthesized thioether oligomer were carried out by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), atomic force microscopy (AFM), Fourier‐transform infrared spectroscopy (FTIR), proton nuclear magnetic resonance spectroscopy (1H NMR) and Size exclusion chromatography (SEC). Obtained results indicate that the modified electrode shows good electrochemical activity, good sensitivity and reproducibility for BPA detection. It exhibited a good linear relationship ranging from 1 to 20 pg/mL, and the detection limit was found to be 1.9 pg/mL at S/N=3. Several interfering species such as hydroquinone, phenol and resorcinol were used and their behaviors on the modified gold electrode were investigated.  相似文献   

7.
A composite Langmuir? Blodgett film prepared from DNA and polyaniline was deposited on the surface of a glassy carbon electrode (GCE) to give a new voltammetric sensor for the β2‐agonist salbutamol (SAL). Cyclic voltammetry and electrochemical impedance spectroscopy were employed to study the characteristic of the modified electrode. The electrochemistry of SAL at the modified electrode was investigated at pH 6.8 by cyclic voltammetry and differential pulse anodic voltammetry. The oxidation of SAL at this electrode is an adsorption‐controlled irreversible process. A sensitive electroanalytical method for determination of SAL was worked out that displays high precision and good reproducibility. The method was applied to quantify SAL in tablets with satisfactory results.  相似文献   

8.
A novel strategy to fabricate hydrogen peroxide (H2O2) sensor was developed by electrodepositing palladium? silver nanoparticles (NPs) on a glassy carbon electrode. The morphology of the modified electrode was characterized by Scanning electron microscopy (SEM). The result of electrochemical experiments showed that such constructed sensor had a favorable catalytic ability, high sensitivity, excellent selectivity towards reduction of hydrogen peroxide (H2O2). The response to H2O2 is linear in the range between 0.30 μM to 2.50 mM, and the detection limit is 0.1 μM (at an S/N of 3).  相似文献   

9.
《Electroanalysis》2017,29(2):456-465
A novel, facile fabrication, based on electrochemically reduced graphene oxide (ErGO), grafted with Pt nanoparticles and Nafion hybrid nano‐composite (ErGO‐Pt/Nafion) on the surface of edge plane pyrolytic graphite (EPPG) has been reported. The fabricated sensor has been used for the sensitive and selective determination of efavirenz (EFZ), a well‐known drug for HIV infections. The ErGO‐Pt/Nafion film was characterized by Field Emission Scanning Electron Microscopy (FE‐SEM), Energy‐dispersive X‐ray spectrometry (EDS) and Electrochemical Impedance Spectroscopy (EIS). The experimental results reveal that the modified sensor displays an excellent electrocatalytic activity towards the oxidation of EFZ and exhibits a large linear dynamic relationship in the range of 0.05 μM to 150 μM, with a detection limit of 1.8 nM. Practical utility of the developed sensor has been demonstrated by determining the EFZ in biological fluids and pharmaceutical samples and a low detection limit with high sensitivity observed makes it valuable for the clinical diagnosis.  相似文献   

10.
An electrochemical sensor for the simultaneous determination of Cd(II) and Pb(II) by square wave anodic stripping voltammetry (SWASV) in bivalve mollusks using a glassy carbon electrode modified with electrochemically reduced graphene oxide has been developed. The modified surface was characterized by cyclic voltammetry, high resolution scanning electron microscopy (HR‐SEM), and Raman spectroscopy. The optimum conditions were optimized and a linear range was observed from 15–105 μg L?1 with a limits of detection of 15 μg L?1 for Cd(II) and Pb(II). The methodology was validated and applied in different samples of commercial bivalve mollusks with satisfactory results. The high conductivity and greater surface area of the modifying agent improves the preconcentration capacity of the electrochemical sensor, allowing to develop a simple, rapid and sensitive analysis in the detection of lead and cadmium in marine resources.  相似文献   

11.
We fabricated a highly sensitive electrochemical sensor for the determination of bisphenol A (BPA) in aqueous solution by using reduced graphene oxide (RGO), carbon nanotubes (CNT), and gold nanoparticles (AuNPs)‐modified screen‐printed electrode (SPE). GO/CNT nanocomposite was directly reduced to RGO/CNT on SPE at room temperature. AuNPs were then electrochemically deposited in situ on RGO/CNT‐modified SPE. Under optimized conditions, differential pulse voltammetry (DPV) produced linear current responses for BPA concentrations of 1.45 to 20 and 20 to 1,490 nM, with a calculated detection limit of an ultralow 800 pM. The sensor response was unaffected by the presence of interferents such as phenol, p‐nitrophenol, pyrocatechol, 2,4‐dinitrophenol, and hydroquinone.  相似文献   

12.
Herein, a simple electrochemical sensor was fabricated for sensing Hg2+ ions by using electrochemically reduced p‐nitrobenzoic acid molecules modified (ERpNBA) glassy carbon electrode (GCE). The modified electrode was applied for the determination of Hg2+ ions by using differential pulse anodic stripping voltammetry (DPASV). Experimental parameters such as concentration of p‐nitrobenzoic acid used for electrode modification, pH, accumulation time and deposition potential used for the determination of Hg2+ ions were optimized. The strong interaction between the Hg2+ ions and the lone pair of electrons on the nitrogen atoms of ERpNBA molecules leads to highly selective adsorption of Hg2+ ions on the modified electrode. Under the optimum experimental conditions, the sensor showed higher sensitivity and very low detection limit for Hg2+ ions than other metal ions such as Cd2+, Pb2+ and Zn2+ ions. The LOD for Hg2+ ions was 240 pM which is below the guideline value given by the World Health Organization and the earlier reports.  相似文献   

13.
The graphene nanosheets/manganese oxide nanoparticles modified glassy carbon electrode (GC/GNSs/MnOx) was simply prepared by casting a thin film of GNSs on the GC electrode surface, followed by performing electrodeposition of MnOx at applied constant potential. The GC/GNSs/MnOx modified electrode shows high catalytic activity toward oxidation of L ‐cysteine. Hydrodynamic amperometry determination of L ‐cysteine gave linear responses over a concentration range up to 120 µM with a detection limit of 75 nM and sensitivity of 27 nA µM?1. The GC/GNSs/MnOx electrode appears to be a highly efficient platform for the development of sensitive, stable and reproducible L ‐cysteine electrochemical sensors.  相似文献   

14.
《Electroanalysis》2018,30(5):921-927
In this research, the high conductivity of nickel chloride solution as well as the ability of nickel ions in establishing particular bonds with curcumin was benefited to fabricate a new electrochemical sensor based on nickel chloride solution modified glassy carbon electrode (NiCl2/GCE) for detection and measurement of curcumin in human blood serum. Atomic force microscope (AFM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) methods indicated that using nickel chloride solution for the modification of the glassy carbon electrode (GCE) surface had a significant effect on improvement of the electrode performance. Differential pulse voltammetry (DPV) was used for quantitative measurement of curcumin, which exhibited the linear response of NiCl2/GCE toward curcumin within the concentration range of 10–600 μM and provided the detection limit of 0.109 μM for curcumin in human blood serum.  相似文献   

15.
利用分子印迹技术,以马来松香丙烯酸乙二醇酯为交联剂,使用自由基热聚合法在石墨烯修饰的玻碳电极表面合成毒死蜱( CPF)分子印迹聚合膜,制得了CPF分子印迹电化学传感器。采用循环伏安法、线性扫描伏安法和电化学交流阻抗法等,考察了此CPF分子印迹膜的电化学性能。在最佳检测条件下,传感器的峰电流与CPF浓度在2.0×10-7~1.0×10-5mol/L范围内呈线性关系,线性方程为Ip(μA)=-7.1834-0.2424C (μmol/L),相关系数r2=0.9959,检出限为6.7×10-8 mol/L(S/N=3)。构建了CPF分子印迹电化学传感器的动力学吸附模型,测得印迹传感器的印迹因子β=2.59,结合速率常数k=12.2324 s。传感器表现出良好的重现性和稳定性,并成功用于实际水样和蔬菜样品中CPF的测定,加标回收率为94.1%~101.4%。  相似文献   

16.
《Electroanalysis》2017,29(2):514-520
A long‐life electrochemical sensor for the continuous analysis of heavy metal ions (Zn(II), Cd(II), Pb(II), Cu(II), and Hg(II)) was developed using the graphene oxide (GO) anchored‐functionalized polyterthiophene (poly[3′‐(2‐aminopyrimidyl)‐2,2′:5′,2′′‐terthiophene], polyPATT) composite. The PATT monomer was synthesized and polymerized with GO to form the composite using a potential cycling method, followed by Nafion coating. The modified sensor surface was characterized employing electrochemical and surface analysis methods. Experimental variables affecting the analytical performance were optimized. Interference effects of other metal ions having similar redox potentials were also investigated. The performance of chronocoulometry (CC) without predeposition was compared with the results of square wave anodic stripping voltammetry (SWASV) with predeposition. The dynamic range of CC for the target ions were between 1 ppb and 10 ppm, respectively with the detection limits between 0.05 (±0.05) and 0.20 (±0.15) ppb for the CC method without predeposition, and between 0.08 (±0.05) and 0.30 (±0.12) ppb for the SWASV with 300 sec of deposition time (n=3 ). The reliability of the method was evaluated by continuously analysing environmental water samples using a single sensor probe in a flow system for 93 days.  相似文献   

17.
A poly(4‐bromoaniline) (PBA) film is electrochemically synthesized on a gold electrode for the recognition of amino acids enantiomers. Scanning electron microscopy measurements show that the porous PBA films are made up of nano‐ribbons. At the PBA modified Au electrode differential pulse voltammograms of L ‐ and D ‐glutamic acids not only have very different current densities, but also produce different waveforms, providing an intuitive way to differentiate the two chiral molecules. Similar results are obtained in analyzing L ‐ and D ‐aspartic acids. Control experiments suggest that the observed sensing behavior arises from synergistic interactions between Au and the PBA film, where polymerization at the meta‐position creates a steric structure needed for differentiating chiral molecules.  相似文献   

18.
This work was designed to develop an electrochemical sensor based on molecular imprinted polyaniline membranes onto reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) modified glassy carbon (GC) electrode for dapsone (DDS) determination. The prepared RGO/AuNPs/PANI‐MIPs nanocomposite was characterized by Ultra‐Violet‐Visible (UV‐Vis), Fourier transform infrared spectroscopy (FT‐IR) and scanning electronic microscopy (SEM) images. The feature of the imprinted electrode was evaluated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and impedance spectroscopy (IS). Throughout this study several analytical parameters, such as incubation time, pH value, concentration of monomer/template molecules and electro‐polymerization cycles were investigated. Under the optimized conditions, the experimental results showed best analytical performances for DDS detection with a sensitivity of 0.188 Ω/mol L?1, a linear range from 1.0×10?7 M to 1.0×10?3 M and a detection limit of 6.8×10?7 M. The bioanalytical sensor was applied to the determination of dapsone in real samples with high selectivity and recovery.  相似文献   

19.
It was first time using the l‐cysteine self‐assembled on the surface of gold nanoparticles and Bi2O3 nano‐structured materials modified GCE composed l‐cysteine/AuNPs/Bi2O3/GCE sensor. The sensor possessed three‐dimensional nanostructure and exhibited a higher ratio of activity sites, large active surface, fast electron transfer rate, excellent catalytic, sensing characteristics and larger affinity to Cu (II). The sensor was determined to have an excellent sensitivity and selectivity for the detection of Cu (II). The characterization of sensor as well as the optimization of the analytical procedure was reported. The optimized conditions parameters allowed the detection of Cu (II) concentration following short analysis time, a detection limit of 5×10?11 M at 80 s of preconcentration time was obtained using the as‐prepared sensor, and also show excellent stability and good repeatability, and, thus, could be used for detection of Cu (II) in environment.  相似文献   

20.
《Electroanalysis》2018,30(9):1918-1928
An electrochemical sensor of glassy carbon electrode modified with reduced graphene oxide and β‐cyclodextrin (GCE/rGO/β‐CD) was developed as an effective alternative in the determination of neonicotinoid insecticides, imidacloprid, clothianidin and thiamethoxam, in honey samples. The peak current variation obtained with the proposed sensor was higher compared to the bare GCE in all the analytes. In the determination of imidacloprid the response increased by 1300 %, clothianidin by 670 % and thiametoxam by 630 %. In addition, the optimization of the experimental conditions provided the construction of a sensor with greater sensitivity. The study of interferers showed that inorganic ions (Ca2+, Mg2+, Fe2+, K+, Na+, e NH4+) and other insecticides (acetamiprid and dinotefuran) did not influence the reduction of imidacloprid, clothianidin and thiamethoxam. The determination of imidacloprid, clothianidin and thiamethoxam in honey samples exhibited recovery values within the EPA range (between 107.75 and 116 %). In conclusion, the developed sensor GCE/rGO/β‐CD proved to be an effective alternative in the determination of neonicotinoid insecticides in honey samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号