首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This work reports the application of screen‐printed electrodes bulk‐modified with bismuth precursors to the voltammetric determination of 2‐nitrophenol (2‐NP), 4‐nitrophenol (4‐NP) and 2,4‐dinitrophenol (2,4‐DNP) in water samples. A bismuth film was formed at the electrode surface via in situ reduction of the precursor compound contained in the electrode matrix by cathodic polarization at ?1.20 V. The formation of bismuth layer at the precursor‐modified electrodes was assessed by cyclic voltammetric (CV) at different pH values and by optical techniques. The target nitrophenols were voltammetrically determined by recording their reduction peaks in the differential pulse (DP) mode. The composition and content of the precursor compounds in the printed ink and the effect of the pH of the supporting electrolyte on the DP reduction currents of the 3 target nitrophenols were studied. The limits of quantification (LOQs) in three water matrices (distilled water, tap water and surface water) were in the range 1.1–2.2 µmol L?1. Using a simple solid‐phase extraction (SPE) procedure with Lichrolut EN cartridges and elution with methanol, a preconcentration factor of 100 was achieved; the LOQs were 0.021, 0.027 and 0.025 µmol L?1 for 2‐NP, 4‐NP and 2,4‐DNP, respectively. The recoveries of samples spiked with the 3 target nitrophenols at two concentration levels (0.04 and 0.1 µmol L?1) were always >87 %.  相似文献   

2.
A method using commercially available sputtered bismuth screen‐printed electrodes (BispSPE), as substitute to mercury electrodes, for the determination of trace Pb(II) and Cd(II) ions in drinking well water samples collected in a contaminated area in The Republic of El Salvador by means of differential pulse anodic stripping voltammetry (DPASV) has been proposed. The comparable detection and quantification limits obtained for both BispSPE and hanging mercury drop electrode (HMDE), together with the similar results with a high reproducibility obtained in these water samples analyses recommend the applicability of BispSPE for the determination of low level of metal concentrations in natural samples.  相似文献   

3.
《Electroanalysis》2004,16(4):328-330
A procedure for the differential pulse voltammetric determination of three local anesthetics (Heptacaine, Carbisocaine and Pentacaine) at a screen‐printed electrode surface modified with the dsDNA layer is described. The detection limits obtained after 120 s drug accumulation from 0.01 M phosphate buffer solution pH 6.96 are 0.02 μM (Pentacaine) and 0.03 μM (Carbisocaine and Heptacaine). The method was applied to the determination of Carbisocaine in spiked serum.  相似文献   

4.
In the present work, a sensitive, facile and disposable sensing platform for trace analysis of heavy metal ions was developed at the Bi modified graphene‐poly(sodium 4‐styrenesulfonate) composite film screen printed electrode (GR/PSS/Bi/SPE). The GR/PSS/Bi/SPE improved sensitivity and linearity due to the functionalization of graphene with negatively charged PSS providing more absorbing sites. The detection limit of the GR/PSS/Bi/SPE is found to be 0.042 µg L?1 for Cd2+ and 0.089 µg L?1 for Pb2+ with linear responses of Cd2+ and Pb2+ in the range of 0.5–120 µg L?1. Finally, the practical application was confirmed in real water with satisfactory results.  相似文献   

5.
Screen‐printed electrodes (SPEs) are cheap and disposable. But their application for heavy metal detection is limited due to the low sensitivity and poor selectivity. Here we report the ultrasensitive and simultaneous determination of Zn2+, Cd2+ and Pb2+ on a multiwalled carbon nanotubes and Nafion composite modified SPE with in situ plated bismuth film (MWCNTs/NA/Bi/SPE). The linear curves range from 0.5–100 µg L?1 for Zn2+ and 0.5–80 µg L?1 for Cd2+. Uniquely, the linear curve for Pb2+ ranges from 0.05–100 µg L?1 with a detection limit of 0.01 µg L?1. The practical application was verified in real samples with satisfactory results.  相似文献   

6.
This work presents a disposable bismuth‐antimony film electrode fabricated on screen‐printed electrode (SPE) substrates for lead(II) determination. This bismuth‐antimony film screen‐printed electrode (Bi‐SbSPE) is simply prepared by simultaneously in situ depositing bismuth(III) and antimony(III) with analytes on the homemade SPE. The Bi‐SbSPE can provide an enhanced electrochemical stripping signal for lead(II) compared to bismuth film screen‐printed electrodes (BiSPE), antimony film screen‐printed electrodes (SbSPE) and bismuth‐antimony film glassy carbon electrodes (Bi‐SbGC). Under optimized conditions, the Bi‐SbSPE exhibits attractive linear responses towards lead(II) with a detection limit of 0.07 µg/L. The Bi‐SbSPE has been demonstrated successfully to detect lead in river water sample.  相似文献   

7.
The electrochemical behaviour of thyroxine (T4) is analysed using the disposable screen‐printed carbon electrode (SPCE) in the neutral phosphate buffer solution with cyclic voltammetric technique. The Differential Pulse Voltammetry and Chronoamperometry were employed for sensing of T4. The lowest detection limit of 3 nM was obtained from the differential pulse voltammetric method without preconditioning. The Density Functional Theoretical study of T4 was performed to elucidate the mechanism of oxidation. The analysis of the commercial pharmaceutical samples indicates the validity of the proposed method.  相似文献   

8.
The cyclic voltammetric behavior of nitrazepam was investigated at screen‐printed carbon electrodes over the range ?1.5 V to +1.5 V. Two reduction peaks were observable on the negative scan, at ?0.7 V, and ?1.2 V using pH 6 buffer. On the return scan a single oxidation peak was obtained at ?0.05 V. For quantitative analysis of beverages, we developed an anodic adsorptive stripping voltammetric method which required only dilution with buffer. The identification of nitrazepam and flunitrazepam could be achieved using cyclic voltammetry.  相似文献   

9.
An amperometric method for the determination of iodide ions has been developed using disposable, screen‐printed electrodes. The used sensors have a gold, graphite and platinum working electrodes with an area of about 7 mm2. Calibration curves exhibit a linear relationship between the electrode response and the iodide concentration up to 3.00 mM. The correlation coefficients for all calibration curves varied from 0.988 to 0.998. The relative standard deviations were equal to or less than 5.26 % (n=5). The lowest iodide concentration measured was 100 µM.  相似文献   

10.
A rapid, simple and sensitive electrochemical assay of horseradish peroxidase (HRP) performed on disposable screen‐printed carbon electrode was developed. HRP activities were monitored by square‐wave voltammetric (SWV) measuring the electroactive enzymatic product in the presence of o‐aminophenol and hydrogen peroxide substrate solution. SWV analysis demonstrated a greater sensitivity and shorter analysis time than the widely used amperometric and differential‐pulsed voltammetric methods. The voltammetric characteristics of substrate and enzymatic product as well as the parameters of SWV analysis were optimized. Under optimized conditions, a linear response for HRP from 0.003 to 0.1 U/mL and a detection limit of 0.002 U/mL (1.25×10?15 mol in 25 μL) were obtained with a good precision (RSD=8%; n=6). This rapid and sensitive HRP assay with microliter‐assay volume could be readily integrated to portable devices and point‐of‐care (POC) diagnosis applications.  相似文献   

11.
A facile, rapid and ultra‐sensitive method for the determination of vitamin B12 (cyanocobalamin) at the sub‐nanomolar concentration range by using low‐cost, disposable graphite screen‐printed electrodes is described. The method is based on the cathodic preconcentration of square planar vitamin B12s, as occurred due to the electro reduction of Co(III) center in vitamin B12a to Co(I), at ?1.3 V versus Ag/AgCl/3 M KCl for 40 s. Then, an anodic square wave scan was applied and the height of the peak appeared at ca. ?0.73 V versus Ag/AgCl/3 M KCl, due to the oxidation of Co(I) to Co(II) in the adsorbed molecule, was related to the concentration of the vitamin B12 in the sample. EDTA was found to serve as a key‐component of the electrolyte by eliminating the background signal caused by metal cations impurities contained in the electrolyte (0.1 M phosphate buffer in 0.1 M KCl, pH 3). It also blocks trace metals contained in real samples, thus eliminating their interference effect. The method was optimized to various working parameters and under the selected conditions the calibration curve was linear over the range 1×10?10–8×10?9 mol L?1 vitamin B12 (R2=0.994), while the limit of detection for a signal‐to‐noise ratio of 3 (7×10?11 mol L?1 vitamin B12) is the lowest value of any reported in the literature for the electrochemical determination of vitamin B12. The sensors were successfully applied to the determination of vitamin B12 in pharmaceutical products.  相似文献   

12.
In this paper, electromembrane extraction coupled with differential pulse voltammetry (DPV) on a reduced graphene oxide modified screen‐printed carbon electrode (RGO‐SPCE) for the determination of dextromethorphan (DXM) in urine and plasma has been described. DXM migrated from 4 mL of a donor phase across a thin layer of 2‐nitrophenyl octyl ether (NPOE) immobilized in the pores of a porous hollow fiber, into a 20 µL acceptor phase (HCl) present inside the lumen of the fiber. Then, 15 µL of a 0.1 M NaOH solution was added to the acceptor phase and the mixture was analyzed using DPV.  相似文献   

13.
A sensitive electroanalytical methodology for the determination of uric acid in real samples using adsorptive voltammetry at a multiwalled carbon nanotubes (MWCNT) modified screen printed electrode (SPCE) is presented. Adsorption of uric acid takes place at open circuit potential at an optimized pH 5.0. Studies about the effect of accumulation time and scan rate on the analytical signal were developed and confirm the adsorption nature of the electrodic process. Quantitative analysis of uric acid by using its oxidation process at +0.18 V (vs. an Ag pseudoreference electrode) was carried out with an accumulation time of 5 min. Thus, a linear voltammetric based reproducible determination of uric acid (RSD 5 %) in the range 1–100 µM was obtained. The method was then successfully used for the determination of uric acid in real clinical samples of urine without detection of interferences. The proposed methodology only requires a dilution of the real sample and present advantages as low cost and easy handling for non specialized technicians.  相似文献   

14.
《Electroanalysis》2006,18(15):1457-1462
This work describes an electroanalytical method for determining gold(I) thiomalate, aurothiomalate, widely used for treatment of reumatoid arthiritis, using a screen‐printed carbon electrode (SPCE). Aurothiomalate (AuTM) was determined indirectly at the same electrode by accumulating it first at ?1.5 V vs. printed carbon. At this potential in the adsorbed state, the AuTM is reduced to Au(0), which is then oxidized at two steps at ?0.22 V and +0.54 V on SPCE. Using optimized conditions of 60 s deposition time, ?1.5 V (vs. printed carbon) accumulation potential, 100 mV s?1 scan rate, linear calibration graphs can be obtained by monitoring the peak at +0.54 V for AuTM in HCl 0.1 mol L?1 from 1.43×10?6 to 1.55×10?4 mol L?1. A limit of detection obtained was 6.50×10?7 mol L?1, and the relative standard deviation from five measurements of 3.0×10?5 mol L?1 AuTM is 4.5%. The method was successfully applied for AuTM determination in human urine sample.  相似文献   

15.
Water is a vital commodity for every living entity on the planet. However, water resources are threatened by various sources of contamination from pesticides, hydrocarbons and heavy metals. This has resulted in the development of concepts and technologies to create a basis for provision of safe and high quality drinking water. This paper focuses on the simultaneous quantitative determination of three common contaminants, the heavy metals cadmium, lead and copper. Multivariate calibration was applied to voltammograms acquired on in‐house printed carbon‐ink screen‐printed electrodes by the highly sensitive electrochemical method of differential pulse anodic stripping voltammetry (DPASV). The statistically inspired modification of partial least squares (SIMPLS) algorithm was employed to effect the multivariate calibration. The application of data pretreatment techniques involving range‐scaling, mean‐centering, weighting of variables and the effects of peak realignment are also investigated. It was found that peak realignment in conjunction with weighting and SIMPLS led to the better overall root mean square error of prediction (RMSEP) value. This work represents significant progress in the development of multivariate calibration tools in conjunction with analytical techniques for water quality determination. It is the first time that multivariate calibration has been performed on DPASV voltammograms acquired on carbon‐ink screen‐printed electrodes.  相似文献   

16.
This work reports the application of bismuth bulk electrode (BiBE) for the determination of 2‐methyl‐4,6‐dinitrophenol (MDNP) by differential pulse voltammetry (DPV) in Britton‐Robinson buffer of pH 12.0 as an optimal medium. BiBE was prepared by transferring molten bismuth into a glass tube under constant stream of nitrogen. The linear concentration dependences were measured from 1 to 10 μmol ? L?1 and from 10 to 100 μmol ? L?1 by using optimum accumulation potential of ?0.7 V and optimum accumulation time 30 s. Under these conditions limit of determination and limit of quantification was 0.45 and 1.5 μmol ? L?1, respectively. The developed method was successfully applied for the analysis of tap water as a model sample.  相似文献   

17.
A new procedure for the speciation of chromium by means of differential pulse voltammetry using screen‐printed carbon electrodes (SPCEs) has been proposed. Two different modified carbon working, a Ag/AgCl reference and a carbon counter screen‐printed electrodes have been connected in array mode for the simultaneous determination of Cr(III) and Cr(VI). Mercury films or gold nanoparticles have been ground onto the SPCEs in order to improve their selectivity to each chromium species. The quantification of the peak currents observed at ?1.25 V in Hg‐SPCE and ?0.1 V in AuNPs‐SPCE were carried out. The method has been applied to the speciation of chromium in waste water from a tannery factory.  相似文献   

18.
Acrylamide (AA) was electrochemically detected and quantified by means of its voltammetric response on carboxylic modified Single‐Walled Carbon Nanotube Screen Printed Electrodes (COOH‐SWCNT‐SPEs). The electroreduction signal of AA was proportional to AA concentration at low values (below 300 µM) and the observed sensitivity was explained in terms of AA adsorption on the COOH‐SWCNT‐SPEs that was demonstrated using the electrochemical response of [Fe(CN)6]3? and [Fe(CN)6]4? and Raman spectroscopy experiments. In order to test the suggested analytic approach (LOD of 0.03 µM, LOQ of 0.04 µM), detection and quantification of AA in fried potatoes was carried out using the proposed electrochemical method and HPLC. Both techniques showed similar contents of AA.  相似文献   

19.
An Ex‐situ antimony film screen‐printed carbon electrode (Ex‐situ SbSPCE) was successfully applied for the determination of Ni(II), by means of adsorptive stripping voltammetry using dimethylglyoxime as complexing agent, in a certified reference wastewater sample. This electrode is proposed as an alternative to more conventional antimony film electrodes. Ex‐situ SbSPCE was analytically characterized and the obtained parameters suggest that Ex‐situ SbSPCE behaves much better than both Ex‐situ BiSPCE and BispSPE for Ni(II) determination. The results confirm the applicability of Ex‐situ SbSPCE for the determination of low concentration levels of Ni(II) in natural samples with a very high reproducibility and good trueness.  相似文献   

20.
The electrochemical oxidation of pyrogallol at electrogenerated poly(3,4‐ethylenedioxythiophene) (PEDOT) film‐modified screen‐printed carbon electrodes (SPCE) was investigated. The voltammetric peak for the oxidation of pyrogallol in a pH 7 buffer solution at the modified electrode occurred at 0.13 V, much lower than the bare SPCE and preanodized SPCE. The experimental parameters, including electropolymerization conditions, solution pH values and applied potentials were optimized to improve the voltammetric responses. A linear calibration plot, based on flow‐injection amperometry, was obtained for 1–1000 µM pyrogallol, and a slope of 0.030 µA/µM was obtained. The detection limit (S/N=3) was 0.63 µM.  相似文献   