首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Analysis of biologically active amines by CE   总被引:1,自引:0,他引:1  
Chiu TC  Lin YW  Huang YF  Chang HT 《Electrophoresis》2006,27(23):4792-4807
This paper provides an overview on the current status of the analysis of biogenic amines by CE. The basic CE separation and detection strategies for the analysis of biogenic amines are briefly described. CZE and MEKC that provide highly efficient and reproducible analysis of biogenic amines are particularly surveyed. With respect to the detection of biogenic amines, we focus on LIF, UV-visible absorption, electrochemiluminescence, and MS. Derivatization strategies, indirect methods, and on-line concentration techniques such as field-amplified sample stacking, sweeping, and use of polymer solution are described. To show the practicality of CE, we highlight currently developed techniques for the determinations of biogenic amines in biological samples, including foods, beverages, cerebrospinal fluids, urine, and single cells.  相似文献   

2.
Serine racemase (SR) is an enzyme responsible for the biosynthesis of D-serine, the coagonist of the N-methyl-D-aspartate receptor, in the brain. Therefore, it has been suggested as a possible therapeutic target for the treatment of various neurodegenerative diseases. To develop a potent inhibitor of SR, a simple, sensitive, fast, and robust assay is needed. In this paper, a new CE method for the determination of D-serine is described. Serine enantiomers are resolved in the form of o-phthaldialdehyde (OPA)/2-mercaptoethanol (2-ME) derivatives in an alkaline BGE composed of 50 mM sodium tetraborate, pH 9.7, and containing 40 mM 2-hydroxypropyl-gamma-CD as a chiral selector. The problem of time-limited stability of OPA/2-ME derivatives has been overcome by employing in-capillary derivatization of the sample, i.e., the derivatization reaction was carried out directly in the separation capillary in the first phase of the CE run. UV-absorption detection at 230 nm allowed concentration detection limit of 3 microM. Baseline resolution of D- and L-serine derivatives was achieved in less than 10 min. This fact, together with the simple sample pretreatment, allowed application of the method to medium-throughput monitoring of SR activity, such as the screening of potential SR inhibitors. A good agreement was achieved between the developed CE method and the previously established HPLC method for determination of the inhibition constant, K(i), of a new SR inhibitor, L-erythro-3-hydroxyaspartate.  相似文献   

3.
This review covers recent advances of capillary electrophoresis (CE) in pharmaceutical analysis. The principle, instrumentation, and conventional modes of CE are briefly discussed. Advances in the different CE techniques (non-aqueous CE, microemulsion electrokinetic chromatography, capillary isotachophoresis, capillary electrochromatography, and immunoaffinity CE), detection techniques (mass spectrometry, light-emitting diode, fluorescence, chemiluminescence, and contactless conductivity), on-line sample pretreatment (flow injection) and chiral separation are described. Applications of CE to assay of active pharmaceutical ingredients (APIs), drug impurity testing, chiral drug separation, and determination of APIs in biological fluids published from 2008 to 2009 are tabulated.  相似文献   

4.
Simple, selective yet sensitive methods to quantify low-abundance bacterial biomarkers derived from complex samples are required in clinical, biological, and environmental applications. In this report, a new strategy to integrate sample pretreatment with chemical analysis is investigated using on-line preconcentration with chemical derivatization by CE and UV detection. Single-step enantioselective analysis of muramic acid (MA) and diaminopimelic acid (DAP) was achieved by CE via sample enrichment by dynamic pH junction with ortho-phthalaldehyde/N-acetyl-L-cysteine labeling directly in-capillary. The optimized method resulted in up to a 100-fold enhancement in concentration sensitivity compared to conventional off-line derivatization procedures. The method was also applied toward the detection of micromolar levels of MA and DAP excreted in the extracellular medium of Escherichia coli bacterial cell cultures. On-line preconcentration with chemical derivatization by CE represents a unique approach for conducting rapid, sensitive, and high-throughput analyses of other classes of amino acid and amino sugar metabolites with reduced sample handling, where the capillary functions simultaneously as a concentrator, microreactor, and chiral selector.  相似文献   

5.
In this study, a new capillary electrophoresis (CE) method is described originally for the sensitive and selective determination of short-chain aliphatic amines in biological samples. These amines were converted into their N-hydroxysuccinimidyl fluorescein-O-acetate (SIFA) derivatives and measured by micellar electrokinetic capillary chromatography with laser-induced fluorescence detection. The derivatization conditions and separation parameters for the aliphatic amines were optimized in detail. The SIFA-labeled amines were fully separated within 8.5 min using 25 mM pH 9.6 boric acid electrolyte containing 60 mM sodium dodecyl sulfate (SDS). The parameters of validation such as linearity of response, precision and detection limits were determined. The detection limits were obtained in the range from 0.02 to 0.1 nM, which was the lowest value reported by CE methods. The developed method was successfully employed to monitor aliphatic amines in serum and cells samples. After comparison of other CE methods using different fluorescent probes, the present method represents a powerful tool for the trace determination of aliphatic amines in complex biological samples.  相似文献   

6.
Emerging fields of biochemical research, such as metabolomics, present challenges to current separation technologies because of the large number of metabolites present in a cell and their often low (submicromolar) concentration. Although capillary electrophoresis (CE) holds great promise as the method of choice for high-resolution separations of biological samples, it suffers from poor concentration sensitivity, especially with the use of UV detection. In CE, sweeping and dynamic pH junction represent two complementary on-line focusing techniques that have been used for sensitivity enhancement of hydrophobic and weakly acidic analytes, respectively. However, the application of either the sweeping or dynamic pH junction technique alone might, in some cases, be less effective for the analysis of certain sample mixtures. Recent work in the development of a hyphenated dynamic pH junction-sweeping technique is presented as an effective on-line method of preconcentration suitable for both hydrophilic (anionic) and hydrophobic (neutral) analytes. Sensitive analyses of flavin metabolites by CE with laser-induced fluorescence (LIF) detection is demonstrated in various biological matrixes, including cell extracts of Bacillus subtilis, pooled human plasma, as well as heat-deproteinized flavoenzymes. Enhanced analyte band narrowing and improved sensitivity is achieved for flavins using dynamic pH junction-sweeping compared to either sweeping or dynamic pH junction alone. This results in over a 1200-fold improvement in sensitivity relative to conventional injection methods, giving a limit of detection (LOD, defined as S/N = 3) of about 4.0 x 10(-12) M. Strategies for sensitive and more comprehensive analyses of other cell metabolites, including nucleotides, coenzymes, and steroids, are also discussed when using on-line focusing techniques in conjunction with multiplexed CE and UV detection.  相似文献   

7.
This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.  相似文献   

8.
Chen G  Bao H  Yang P 《Electrophoresis》2005,26(24):4632-4640
A microchip CE-amperometric detection (AD) system has been fabricated by integrating a two-dimensionally adjustable CE microchip and an AD cell containing a one-dimensionally adjustable disk detection electrode in a Plexiglas holder. It facilitates the precise 3-D alignment between the channel outlet and the detection electrode without a complicated 3-D manipulator. The performance of this unique system was demonstrated by separating five aromatic amines (1,4-phenyldiamine, aniline, 2-methylaniline, 4-chloroaniline, and 1-naphthylamine) of environmental concern. Factors influencing their separation and detection processes were examined and optimized. The five analytes have been well separated within 140 s in a 74 cm long separation channel at a separation voltage of +2500 V using a 10 mM phosphate buffer (pH 3.5). Highly linear response is obtained for the five analytes over the range 20-200 microM with the detection limits ranging from 0.46 to 1.44 microM, respectively. The present system demonstrated long-term stability and reproducibility with RSDs of less than 5% for the peak current (n = 9). The new approach for the microchannel-electrode alignment should find a wide range of applications in CE, flowing injection analysis, and other microfluidic analysis systems.  相似文献   

9.
One of the weak points of capillary electrophoresis is the need to implement rigorously sample pretreatment because its great impact on the quality of the qualitative and quantitative results provided. One of the approaches to solve this problem is through the symbiosis of automatic continuous flow systems (CFSs) and capillary electrophoresis (CE). In this review a systematic approach to CFS-CE coupling is presented and discussed. The design of the corresponding interface depends on three factors, namely: (a) the characteristics of the CFS involved which can be non-chromatographic and chromatographic; (b) the type of CE equipment: laboratory-made or commercially available; and (c) the type of connection which can be in-line (on-capillary), on-line or mixed off/on-line. These are the basic criteria to qualify the hyphenation of CFS (solid-phase extraction, dialysis, gas diffusion, evaporation, direct leaching) with CE described so far and applied to determine a variety of analytes in many different types of samples. A critical discussion allows one to demonstrate that this symbiosis is an important topic in research and development, besides separation and detection, to consolidate CE as a routine analytical tool.  相似文献   

10.
DNA adducts are regarded as individual internal dosimeters for the exposure to chemical carcinogens. To date, the most sensitive method for DNA adduct analysis is the radioactive 32P-postlabeling method, which allows the detection of one adduct in 10(10) unmodified nucleotides in microg amounts of DNA. However, this technique suffers from disadvantages such as working with radioactive phosphorus and time-consuming chromatographic separation procedures. In addition, the simultaneous detection of adducts from different classes of carcinogens in a DNA sample is difficult. In order to overcome these drawbacks, we are developing a new detection method, comprising fluorescence labeling of DNA adducts, capillary electrophoretic (CE) separation, and on-line detection by monitoring laser-induced fluorescence (LIF). So far, we have evaluated the separation power and the detection limit of CE with fluorescently labeled standard compounds such as unmodified nucleotides or alkylated thymidines. For this purpose, we developed a universal method for labeling 5'-OH-mononucleosid-3'-dicyanoethyl-phosphates with fluorescent dyes based on the phosphoramidite technology for DNA synthesis. The separation of N3-methylated, N3-, O2- and O4-butylated thymidines from the unmodified nucleotide within a few minutes recommends CE-LIF as a powerful method for DNA adduct analysis.  相似文献   

11.
Underberg WJ  Waterval JC 《Electrophoresis》2002,23(22-23):3922-3933
This survey as a sequel of two earlier reports gives an overview of recent developments, starting from 1999, in the use of derivatization protocols in capillary electrophoretic (CE) analysis. Derivatization is mainly used for enhancement of the detection sensitivity in CE, for which a combination of fluorescence labeling and laser-induced fluorescence detection is favorable. Moreover, especially in the field of saccharide assay, derivatization to introduce charge into the molecule, is common. Derivatization procedures are classified in tables, focused on precapillary, on-line, on-capillary and postcapillary arrangements and divided in sections concerning the functional group that is derivatized. The most frequently reported groups are amines and the reducing end of (oligo)saccharides, but thiols, carbonyl and carboxyl groups, steroids and inorganic ions have also been reported about. Other reasons for derivatization are to enhance chiral separation, introduction of a suitable charge into the molecule or to improve mass spectrometric detection. The use of derivatization techniques for special cases, such as the analysis of neurotransmitters, insulin antibodies and mitochondria has also been incorporated as well as a study on the adsorption of proteins onto capillary walls during CE in which derivatization plays a role.  相似文献   

12.
A method of on-line chemiluminescence detection with capillary electrophoresis for biogenic amines (diaminopropane, putrescine, cadaverine and diaminohexane) labeled with N-(4-aminobutyl)-N-ethylisoluminol is reported for the first time. Two separation modes, capillary zone electrophoresis and micellar electrokinetic chromatography (MEKC), were studied. The results show that excellent resolution was achieved in MEKC. Parameters affecting separation process and chemiluminescence detection have been examined in detail. Under the optimum conditions, the baseline separation of four amines was obtained within 7.5 min. The detection limits (S/N=3) of diaminopropane, putrescine, cadaverine and diaminohexane are 3.5 x 10(-8), 3.5 x 10(-8), 3.9 x 10(-8) and 1.2 x 10(-7) M, respectively. The method was applied to the analysis of biogenic amines in lake water.  相似文献   

13.
We describe a rapid, simple, and highly efficient capillary electrophoresis (CE)-based method for the analysis of nanoparticles (NPs). In this study, we used the reversed electrode polarity stacking mode (REPSM) of CE to assess the feasibility of enhancing the detection of Au NPs and Au/Ag NPs, optimizing parameters such as the length of time for which the REPSM was applied, the concentrations of the buffer and the sodium dodecylsulfate (SDS) surfactant, and the pH. Under the optimized on-line enhancement conditions [buffer: SDS (40 mM) and 3-cyclohexylamino-1-propanesulfonic acid (CAPS; 10 mM) at pH 10.0; applied voltage: 20 kV; REPSM applied for 24s], the detection limits of the Au NPs and Au/Ag NPs increased by ca. 30- and 140-fold, respectively. In addition, when the NPs were subjected to on-line enhancement and separation by CE using diode array detection (DAD), this approach allowed chemical characterization of the NP species. Our results suggest that such CE analyses will be useful for accelerating the rates of fabrication and characterization of future nanomaterials.  相似文献   

14.
A new highly sensitive capillary electrophoresis (CE) method applying dynamic coating and on-line stacking for the monitoring of nucleotide pyrophosphatases/phosphodiesterases (NPPs) and the screening of inhibitors was developed. NPP1 and NPP3 are membrane glycoproteins that catalyze the hydrolysis nucleotides, e.g. convert adenosine 5'-triphosphate to adenosine 5'-monophosphate (AMP) and pyrophosphate. Enzymatic reactions were performed and directly subjected to CE analysis. Since the enzymatic activity was low, standard methods were insufficient. The detection of nanomolar AMP and other nucleotides could be achieved by field-enhanced sample injection and the addition of polybrene to the running buffer. The polycationic polymer caused a dynamic coating of the silica-fused capillary, resulting in a reversed electroosmotic flow. The nucleotides migrated in the direction of the electroosmotic flow, whereas the positively charged polybrene molecules moved in the opposite direction, resulting in a narrow sample zone over a long injection time. Using this on-line sensitivity enhancement technique, a more than 70-fold enrichment was achieved for AMP (limit of detection, 46 nM) along with a short migration time (5 min) without compromising separation efficiency and peak shape. The optimized CE conditions were as follows: fused-silica capillary (30 cm effective lengthx75 mum), electrokinetic injection for 60 s, 50 mM phosphate buffer pH 6.5, 0.002% polybrene, constant current of -60 muA, UV detection at 210 nm, uridine 5'-monophosphate as the internal standard. The new method was used to study enzyme kinetics and inhibitors. It opens an easy way to determine the activities of slowly metabolizing enzymes such as NPPs, which are of considerable interest as novel drug targets.  相似文献   

15.
A method for coupling an electrophoretic driven separation to a liquid flow, using conventional fused-silica capillaries and a soft polymeric interface is presented. A novel design of the electrode providing high voltage to the electrophoretic separation was also developed. The electrode consisted of a conductive polyimide/graphite imbedded coating immobilized onto the capillary electrophoresis (CE) column inlet. This integrated electrode gave the same separation performance as a commonly used platinum electrode. The on-column electrode also showed good electrochemical stability in chronoamperometric experiments. In addition, with this electrode design, the electrode position relative to the inlet end of the CE column will always be constant and well defined. The on-line flow injection analysis (FIA)-CE system was used with electrospray ionization (ESI)-time of flight (TOF)-mass spectrometry detection. The preparation of the PDMS (poly(dimethylsiloxane)) interface for FIA-CE is described in detail and used for initial tests of the on-column polymer-imbedded graphite inlet electrode. In this interface, a pressure-driven liquid flow, a make up CE electrolyte and a CE column inlet meet in a two-level cross (95 microm ID) in the PDMS structure, enabling independent flow characterization.  相似文献   

16.
Huie CW 《Electrophoresis》2003,24(10):1508-1529
A review of recent developments in theoretical as well as application studies concerning the use of organic solvents, either as purely nonaqueous solvents, hydro-organic mixtures, or a combination of an organic solvent with another organic modifier(s), in the sample matrix and/or separation buffer for effecting sample pretreatment and/or improving separation performances in capillary electrophoresis (CE) is presented. In particular, recent advances made in furthering the basic understanding of selectivity changes that occur in capillary zone electrophoresis due the presence of organic solvents in the separation medium, based on in-depth studies of fundamental processes, such as acid-base chemistry, ion-ion and ion-solvent interactions, were discussed in detail. The utilization of organic solvents for improving the resolution of highly challenging and important separations, i.e., those involving the separation of positional and optical isomers, was also critically reviewed. Furthermore, a comprehensive survey of the use of organic solvents for on-line sample pretreatment, e.g., minimizing aggregation and maximizing solubilization of hydrophobic analytes, improving concentration detection sensitivity for analytes via the use of sample stacking, was presented and discussed. Moreover, recent applications involving the use of organic solvents for improving the CE separations of a variety of molecular species with significance in various disciplines, including biological, environmental and pharmaceutical areas, were summarized and tabulated.  相似文献   

17.
A simple capillary electrophoresis method was developed to separate and quantify methylmercury, ethylmercury, and phenylmercury with the enhancement of pre-column derivatization and on-line stacking.  相似文献   

18.
New strategies for integrating sample pretreatment with chemical analyses under a single format is required for rapid, sensitive and enantioselective analyses of low abundance metabolites in complex biological samples. Capillary electrophoresis (CE) offers a unique environment for controlling analyte/reagent band dispersion and electromigration properties using discontinuous electrolyte systems. Recent work in our laboratory towards developing a high-throughput CE platform for low abundance metabolites via on-line sample preconcentration with chemical derivatization (SPCD) is primarily examined in this review, as there have been surprisingly only a few strategies reported in the literature to date. In-capillary sample preconcentration serves to enhance concentration sensitivity via electrokinetic focusing of long sample injection volumes for lower detection limits, whereas chemical derivatization by zone passing is used to expand detectability and selectivity, notably for enantiomeric resolution of metabolites lacking intrinsic chromophores using nanolitre volumes of reagent. Together, on-line SPCD-CE can provide over a 100-fold improvement in concentration sensitivity, shorter total analysis times, reduced sample handling and improved reliability for a variety of amino acid and amino sugar metabolites, which is also amenable to automated high-throughput screening. This review will highlight basic method development and optimization parameters relevant to SPCD-CE, including applications to bacterial metabolite flux and biomarker analyses. Insight into the mechanism of analyte focusing and labeling by SPCD-CE is also discussed, as well as future directions for continued research.  相似文献   

19.
A novel dual-cloud point extraction (dCPE) technique is proposed in this paper for the sample pretreatment of capillary electrophoresis (CE) speciation analysis of mercury. In dCPE, cloud point was carried out twice in a sample pretreatment. First, four mercury species, methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) formed hydrophobic complexes with 1-(2-pyridylazo)-2-naphthol (PAN). After heating and centrifuging, the complexes were extracted into the formed Triton X-114 surfactant-rich phase. Instead of the direct injection or analysis, the surfactant-rich phase containing the four Hg species was treated with 150 microL 0.1% (m/v) l-cysteine aqueous solution. The four Hg species were then transferred back into aqueous phase by forming hydrophilic Hg-l-cysteine complexes. After dCPE, the aqueous phase containing the Hg-l-cysteine complexes was subjected into electrophoretic capillary for mercury speciation analysis. Because the concentration of Triton X-114 in the extract after dCPE was only around critical micelle concentration, the adsorption of surfactant on the capillary wall and its possible influence on the sample injection and separation in traditional CPE were eliminated. Plus, the hydrophobic interfering species were removed thoroughly by using dCPE resulted in significant improvement in analysis selectivity. Using 10 mL sample, 17, 15, 45, and 52 of preconcentration factors for EtHg, MeHg, PhHg, and Hg(II) were obtained. With CE separation and on-line UV detection, the detection limits were 45.2, 47.5, 4.1, and 10.0 microg L(-1) (as Hg) for EtHg, MeHg, PhHg, and Hg(II), respectively. As an analysis method, the present dCPE-CE with UV detection obtained similar detection limits as of some CE-inductively coupled plasma mass spectrometry (ICPMS) hyphenation technique, but with simple instrumental setup and obviously low costs. Its utilization for Hg speciation was validated by the analysis of the spiked natural water and tilapia muscle samples.  相似文献   

20.
A novel approach in glycosaminoglycomics, based on sheathless on-line capillary electrophoresis/nanoelectrospray ionization-quadrupole time of flight-mass spectrometry (CE/nanoESI-QTOF-MS) and tandem MS of extended chondroitin sulfate/dermatan (CS/DS) oligosaccharide chains is described. The methodology required the construction of a new sheathless CE/nanoESI-QTOF-MS configuration, its implementation and optimization for the high sensitivity analysis of CS/DS oligosaccharide mixtures from conditioned culture medium of decorin transfected human embryonic kidney (HEK) 293 cells. Under newly established sheathless on-line CE/(-)nanoESI conditions for glycosaminoglycan (GAG) ionization and MS detection, single CS/DS oligosaccharide components of extended chain length and increased sulfation degree were identified. Molecular ions corresponding to species carrying 5 and 6 negative charges could be generated for large GAG oligosaccharide species in the negative ion nanoESI-MS. The optimized on-line conditions enabled the detection of molecular ions assigned to oversulfated tetradeca-, octadeca-, and eicosasaccharide CS/DS molecules, which represent the category of largest sulfated GAG-derived oligosaccharides evidenced by CE/ESI-MS. By on-line CE/ESI tandem MS in data-dependent acquisition mode the oversulfated eicosasaccharide species could be sequenced and the localization of the additional sulfate group along the chain could be determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号