共查询到20条相似文献,搜索用时 0 毫秒
1.
Georg Steinhauser Stefan Merz Johannes H. Sterba 《Journal of Radioanalytical and Nuclear Chemistry》2013,296(1):165-168
We present and discuss a modification of instrumental neutron activation analysis (INAA) that is sensitive for nuclides that do not yield (suitable) activation products but have high cross sections for neutron absorption. Their presence in a sample may thwart INAA by neutron flux suppression inside the sample, but they remain undetected and thus unnoticed by the analyst. In particular, this refers to Li, B, Cd and Gd. The proposed method—instrumental neutron absorption activation analysis (INAAA)—takes advantage of the flux depression inside the sample caused by the neutron absorbers. It is made visible by addition of an activatable nuclide (indicator). The concentration of the neutron absorber (analyte) causes a decrease in activity of the indicator. The activity difference between a mixed sample (sample plus indicator) and the pure indicator carries the analytical information. The calibration curve hence follows a reciprocal exponential function. In a proof-of-principle experiment, the applicability for the quantification of boron was exemplified. In presence of only one neutron absorber (whose nature is known), INAAA can be applied easily for quantification of the analyte in powdered or liquid samples. Although INAAA is no trace sensitive method, it has the potential to increase the reliability of INAA analyses by fast and straightforward quality control (even in presence of two or more neutron absorbing nuclides). It is especially suited for research reactors that do not operate a prompt gamma neutron activation analysis (PGNAA) station. 相似文献
2.
Samples of a pyritic lead-zinc ore and some benefication products were examined by instrumental activation analysis using
Ge(Li) gamma-spectrometry. The following elements were determined using thermal neutron activation: Sc, Cr, Co, Zn, As, Se,
Ag, Sb, Ir, Au and Th. The technique is especially favourable for the determination of cobalt, arsenic, antimony and gold,
but selenium, silver and thorium can also be determined in most fractions. Activation with epithermal neutrons will improve
conditions for the determination of As, Sb, Se, Ag, Au and Th. 相似文献
3.
S. M. Lin C. H. Chiang C. H. Huang C. L. Tseng M. H. Yang 《Journal of Radioanalytical and Nuclear Chemistry》1985,96(2):153-160
Five kinds of urinary stones from 42 patients have been determined for a total of 19 elements by instrumental neutron activation analysis. Of these elements, Ca, Mg, Sr, Na, and Cl are found to be present in the core of all kinds of stones. The differences in elemental composition among the different kinds of stones as well as across the layers of stone are statistically evaluated. 相似文献
4.
Instrumental neutron activation was used for the determination of 23 trace and minor elements in 4 different samples of brewer's
yeast. Detection limits for these elements vary from 2 ppb to 100 ppm. The following average concentrations were found (ppm,
dry weight): Al 597, Br 0.36, Cl 1473, Co 0.21, Cu 19, Fe 285, K 16 400, Mg 1355, Mn 8.4, Na 2330, Rb 19, Sb 0.053, Se 1.2,
V 2.2 and Zn 80. NBS standard 1569 was also analyzed and the following concentrations (in ppm) were measured: Al 2300, Br
0.65, Ce 0.23, Cl 460, Co 0.26, Cr 2.12, Cu 11, Fe 707, Gd 7.1, Hf 0.13, K 15 500, Mg 1780, Mn 7, Na 510, Rb 16, Sb 0.075,
Sc 0.18, Se 0.92, Th 3.7, Ti 38, U 0.49, V 4.1 and Zn 70. 相似文献
5.
A procedure has been developed for the detection of gunpowder residues deposited on the hand of a person firing a gun. The
method is based on neutron activation analysis of the antimony level on the surface of the hand. The surface materials are
removed by a film made by spraying a 4% solution of cellulose acetate in acetone, which sets to form a thin film that can
readily be stripped off. This technique was found to be preferable to the paraffin-lift technique which is in common use.
Following neutron activation of the film in a nuclear reactor, antimony is assayed by high-resolution Ge(Li) spectrometry
without prior chemical processing. The sensitivity of the method is about 5·10−9 g Sb, with a precision of about ±10% at a neutron flux of 5·1013 n·cm−2·sec−1. Analysis of twenty samples taken from the hands of persons who had fired a pistol gave Sb levels of 0.4±0.2 μg, compared
with 0.024±0.013 μg found on the hands of persons who had not fired a revolver. The possible extension of the present technique
to include the determination of additional elements is discussed.
Project carried out with the support of the Office of the Chief Scientist to the Ministry of Defense and with the collaboration
of the Israel Police. 相似文献
6.
S. Tadjiki H. N. Erten J. Erten 《Journal of Radioanalytical and Nuclear Chemistry》1995,199(4):309-316
Instrumental neutron activation analysis has been used to determine 15 trace elements in twelve blood serum samples taken from healthy students at Bilkent University in Ankara. The method allowed the determination of Sc, Cr, Mn, Fe, Co, Zn, Se, Rb, Cs, Ce, Eu, Tb, Hf, Ta and Hg, which occur at the g.ml–1 to ng.ml–1 levels. There are no values reported for Tb, Hf, Ce, Eu and Ta before. The other results are compared with the values reported in the literature. Most are in the range of the reported values except for Fe, Zn, Se and Cs. 相似文献
7.
S. Ahmad M. S. Chaudhary I. H. Qureshi 《Journal of Radioanalytical and Nuclear Chemistry》1981,67(1):119-125
An instrumental neutron activation analysis technique has been developed for the simultaneous determination of up to 30 elements
including major, minor and trace elements in Obsidian Rock (a proposed NBS-SRM-278). INAA method involves both short and long
irradiations followed by gamma-ray activity measurement with a Ge(Li) detector. The accuracy of the procedure has been checked
by analyzing IAEA Reference Materials. 相似文献
8.
A group of 27 tobacco samples was submitted to INAA. Bowen's Kale was analyzed with the samples. The resulting data for 21
elements in tobacco were processed by a cluster programme. This combination proves to be a convenient tool for discrimination
within one group of samples. 相似文献
9.
H. A. Das J. Zonderhuis R. Rose 《Journal of Radioanalytical and Nuclear Chemistry》1972,11(2):273-281
The possibilities are discussed of the instrumental activation analysis of phosphorus in rocks by the reaction31P(n, γ)32P (T=14.2 d). Results are given for six standard rocks of the U.S. Geological Survey. 相似文献
10.
Y. G. Liu E. J. Trione J. C. Laul R. A. Schmitt 《Journal of Radioanalytical and Nuclear Chemistry》1982,69(1-2):427-439
The concentrations of seventeen elements in two species of fungus which cause wheat bunt disease,Tilletia caries (DC.) Tul. andTilletia controversa Kühn, were determined by instrumental neutron activation analysis. Differences in the K and Cl concentrations between these
two species of spores are large and therefore can be used as a criterion for distinguishing between the two species of fungus. 相似文献
11.
I. Obrusník B. Stárková J. Blažek 《Journal of Radioanalytical and Nuclear Chemistry》1976,31(2):495-502
Instrumental neutron activation analysis (INAA) has been utilized for the analysis of 19 different fly ashes, 1 sample of
coal and 3 samples of industrial emissions. Both short and long irradiations in a nuclear reactor have been used. The irradiated
samples have been measured by means of a computer-based Ge(Li) gamma-ray spectrometer. The concentrations of 27 elements have
been determined in the samples. 相似文献
12.
The single comparator method in neutron activation analysis has been applied to the investigation of the purity of silicon
single-crystals of different origins. The following impurities were determined: Au, Sb, Co, Cu and Na. Studies were also carried
out on the surface contamination of silicon samples introduced through steps of sample preparation and irradiation. Up to
nineteen elements on the surface of samples were analysed and found to be easily reduced to low levels or detection limits
by washing and etching. 相似文献
13.
W. E. Kuykendall Jr. L. E. Fite R. E. Wainerdi 《Journal of Radioanalytical and Nuclear Chemistry》1974,19(2):351-358
Résumé La mesure de traces d'éléments dans l'air ambiant a fait l'objet d'une attention accrue ces derniers mois, en raison d'un
intérêt grandissant pour les dangers en puissance pour la santé, qui résultent de l'exposition prolongée à certaines substances
toxiques. L'analyse par activation neutronique a été employée avec succès dans la recherche de traces d'éléments, et ce, pour
un grand nombre d'études de l'environnement; elle semble convenir de fa?on idéale pour la détermination non-destructive multi-élémentaire
de la composition de milieux de particules portées par l'air. Dans cet article, on rend compte des performances de l'analyse
instrumentale par activation neutronique comme on le montre dans le cas de 40 échantillons d'air filtrées provenant d'une
zone métropolitaine.
相似文献
14.
Tree rings and needles of young spruce clones from the immission area of the Al-refinery Ranshofen (Upper Austria), which had ceased production in 1992, were investigated by INAA. Short time irradiation was performed for determining, Al, Mn, Ca and Cl, while the elements Na, K, Rb, Ba, Zn, Fe, Sc, Cr, Co, Br and in some samples also Ca were determined via middle- and long-lived radioisotopes. Irradiation and counting conditions are given. Accuracy and sensitivity are sufficient to describe the trends of the element concentrations in needles and with the exception of Cr, Sc and Br, in tree rings. Ca-concentrations derived from49Ca (short-time irradiation) and47Ca (long-time irradiation) are compared and show good agreement Additionally Mg was determined in some samples by ICP-AES and if possble, by INAA. The results are compared. 相似文献
15.
R. Dams A. M. Buysse M. Helsen 《Journal of Radioanalytical and Nuclear Chemistry》1982,68(1-2):219-231
Instrumental neutron activation analysis has been applied for the analysis of four sewage sludges of municpal water treatment
plants, one sludge of an industrial water treatment plant one compost of a municipal compostation plant in Belgium. This pilot
study showed that concentrations for 41 elements could be obtained. Tests for homogeneity and accuracy indicated the necessity
of a thorough grinding and homogenization of the samples before analysis. The concentrations obtained were compared with the
mean soil composition and the possible enrichment of heavy metals in the soil calculated when the materials are used as a
manure to agricultural land. The Zn concentration is mostly the limiting factor for the agricultural application. 相似文献
16.
L. -Y Sun M. R. Conrady R. A. Schmitt 《Journal of Radioanalytical and Nuclear Chemistry》1984,81(2):323-331
Sodium contents in seven mixtures of biological materials from varying aliquants of wheat flour and oyster tissue were analyzed using the INAA (instrumental neutron activation analysis) method. The samples were activated in the thermal column (TC) of the 1 MW TRIGA reactor at our laboratory. To analyze and compare the measured results, the ratioa of the epithermal neutron flux to the thermal neutron flux was determined in the TC, the rotating rack (RR) and the pneumatic terminal (PT). Due to the negligible interferences of24Mg(n, p)24Na and27Al(n, )24Na to23Na(n, )24Na, the Na results were obtained with 97% accuracy and 99% precision. It is shown that the method is suited for accurately determining Na contents in 12 various biological materials, especially for the samples that are low in Na content. From the cadmium ratio measurements of Au (4.9 eV resonance of198Au) and Sm (8 eV resonance of153Sm), ratios ofae/0 were determined at 0.0011, 0.052 and 0.053 in the TC, RR and PT activation positions, respectively. 相似文献
17.
I. Kuleff R. Djingova K. Kostadinov D. Todorovsky 《Journal of Radioanalytical and Nuclear Chemistry》1981,62(1-2):187-194
A scheme for INAA of 32 elements (As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Eu, Fe, Hf, Hg, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb,
Sc, Sm, Ta, Tb, Th, U, W. Yb, Zn) in quartz glass is proposed. The accuracy of the procedure is evaluated by the analysis
of two NBS standard reference materials (SRM-1571 and SRM-1632-a). The method is convenient for routine work. The method was
used for the determination of impurities in laboratory quartz glass.
Dedicated to the 60th birthday of acad. prof. g. bliznakov 相似文献
18.
Bromine was determined by instrumental neutron activation analysis in tissues and organs of pigs as an indicator of brominated vegetable oil residues. The bromine content was found to be dose-related. An advantage of this technique is that the sample was not treated chemically. The analyses were done with the aid of an automatic sample changer and computer reduction of the data. Rapid and reliable analyses were obtained at the p.p.m. level. 相似文献
19.
The fast irradiation facility Mach-1 installed at the Danish DR 3 reactor has been used in boron determinations by means of Instrumental Neutron Activation Analysis using12B with 20-ms half-life. The performance characteristics of the system are presented and boron determinations of NBS standard reference materials as well as fertilizer materials are compared by literature value and spectrophotometric measurements, respectively. In both cases good agreement is obtained. 相似文献
20.
Y. S. Khrbish I. O. Abugassa N. Benfaid A. A. Bashir 《Journal of Radioanalytical and Nuclear Chemistry》2007,271(1):63-69
Cement is widely used as a construction material in Libya. Production plants introduce certain contaminants to the environment.
The dust from such plants is carried away to neighbouring areas. This dust contains a substantial amount of contaminants depending
on the origin of clays used in the production. In this study, a survey of elemental concentration of clay and cement was carried
out to assess the environmental impact of such plants, especially those that are situated near residential and agricultural
areas. Cement and clay samples, imported and locally produced, were analyzed. Instrumental neutron activation analysis was
utilized to determine the elemental concentration of As, Ca, Ce, Co, Cr, Eu, Fe, Hf, La, Na, Rb, Sb, Sc, Sm, Ta, Th, U, Yb
and Zn. Elevated concentrations of U and Th were found in a number of cement samples. The two nuclides are part of an elaborate
decay scheme producing a range of radioactive elements, which emit alpha-, beta- and gamma-radiation. With 40K, they could give elevated levels of background radiation in buildings resulting in higher exposure doses. This could pose
a health hazard and a detrimental effect on the well being of residents, especially in poor ventillated buildings. Also, cement
is the main component for constructing underground reservoirs for collecting rainwater for drinking in private residences,
so some harmful elements could leach into water. This is the first comprehensive survey of commercial cement brands and clays
used in Libya. These results are intended to build a database for trace element concentrations using INAA. 相似文献