首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Capillary zone electrophoresis (CZE) was used for characterisation of soil humic acid (HA) fractions obtained by coupling size-exclusion chromatography with polyacrylamide gel electrophoresis, on the basis of their molecular size and electrophoretic mobility. CZE was conducted using several low alkaline buffers as background electrolyte (BGE): 50 mM carbonate, pH 9.0; 50 mM phosphate, pH 8.5; 50 mM borate, pH 8.3; 50 mM Tris-borate+1 mM EDTA+7 M urea+0.1% sodium dodecyl sulphate (SDS), pH 8.3. Independently of BGE conditions, the effective electrophoretic mobility of HA fractions were in good agreement with their molecular size. The better resolution of HA were obtained in Tris-borate-EDTA buffer with urea and SDS. This results indicated that CZE, mostly with BGE-contained disaggregating agents, is useful for separating HAs in fractions with different molecular sizes.  相似文献   

2.
Two carrier-free electrophoretic separation methods, capillary zone electrophoresis (CZE) and continuous free-flow zone electrophoresis (FFZE), have been applied to both microanalysis at the nanogram level and preparative fractionation, with a throughput of 30 mg/h, of synthetic growth hormone releasing peptide (GHRP). A crude product of GHRP, a hexapeptide with the sequence His-D-Trp-Ala-Trp-D-Phe-Lys-NH2, synthesized by the solid phase methodology, was desalted and analyzed by CZE. Based on the results of analytical CZE the separation was converted into a preparative purification procedure by continuous FFZE, employing the same separation medium (0.5 mol/L acetic acid, pH 2.6). The purifity of peptide fractions obtained by FFZE was reevaluated by CZE. The combination of these two techniques proved to be a valuable tool for both peptide analysis and peptide purification. A close correlation of CZE and FFZE, resulting from the fact that both methods are based on the same separation principle (zone electrophoresis) and that both are performed in a free solution of the same composition, was confirmed. However, when transforming data from CZE to FFZE, the different electroosmotic flow, temperature and electric field intensity in the capillary and in the flow-through cell, respectively, have to be taken into account and corresponding corrections have to be made.  相似文献   

3.
Summary To measure the five classical protein fractions in human serum several electrophoretic techniques are available. Besides separation on cellulose acetate membrane or agarose gel, capillary zone electrophoresis (CZE) may be a useful analytical alternative in clinical routine. We have compared the Dionex CES I capillary electrophoresis system with that of the Olympus Fractoscan using specimens submitted for routine analysis. For clinical evaluation 102 samples from patients with various diseases have been analysed. Serum protein fractions were judged on separation performance, precision and the regression method ofBablok-Passing. Regression analysis revealed variable agreement between both methods with a slope ± intercept of 2.10–0.52 (α1-fraction) and 1.0–0.20 (α2-fraction) as worse and best, resectively; and the coefficient of variation of migration time: 5.9 %–6.8 % (between-run imprecision). Differences in the comparison of fractions are mainly caused by the improved resolution of CZE; e.g. one β-globulin peak on cellulose acetate is separated into two distinct protein fractions in CZE, including more detailed diagnostic information—as is also the case with γ-fraction. In some cases monoclonal gammopathy with low concentrations of immunglobulin clone can only be detected in CZE, whereas the cellulose acetate membrane (CAME) electropherogram is inconspicuous. The within-run precision (N=18) gave coefficients of variation of peak areas 1.3–5.9 % (CZE) and 1.0–3.8 % (cellulose acetate membrane). This is the first time that a complete clinical evaluation of CZE serum protein fraction analysis has been performed. CZE with its higher resolution and hence more detailed diagnostic information in some cases, showed good separation patterns, precision and correlation. Interchangeability of results showed that this CZE method is well suited for analysis of serum protein fractions in clinical routine. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996.  相似文献   

4.
将在线富集技术同二维(2D)毛细管电泳(CE)分离相结合同时提高复杂样品中痕量组分的分离度和检测灵敏度.毛细管区带电泳(CZE)作为第一维,分析物根据淌度不同进行分离,第一维流出组分进入第二维毛细管,根据分配系数不同进行胶束电动毛细管色谱(MEKC)分离.采用阳离子选择性耗尽进样(CSEI)在柱预富集,延长进样时间,增大进样量;同时在二维毛细管接口处采用动态pH联接/胶束扫集在线富集技术不仅避免第一维分离组分在接口处扩散,还可进一步压缩样品区带.同常规电动进样CE分离相比,该在线富集二维分离技术的分离能力远远高于一维CZE或MEKC分离,富集倍数达到(0.5~1.2)×104.该法成功应用于人体尿样中四种药物及对映体的分析测定,浓度检出限为0.1~0.3μg/L.进一步研究了人体尿样中四种药物24h内的药代动力学规律.  相似文献   

5.
A novel method has been developed by integration of multi-concentration and two-dimensional(2D) capillary electrophoresis(CE) for simultaneous enhancement of detection sensitivity and separation power in complex samples.Capillary zone electrophoresis(CZE) was used as the first dimension separation according to mobilities,from which the effluent fractions were further analyzed by micellar electrokinetic capillary chromatography(MEKC) acting as the second dimension.Cation-selective exhaustive injection(CSEI) ...  相似文献   

6.
We have used free flow electrophoresis (FFE) technology to study the electrophoretic behavior of growth hormone (GH) molecules, GH secretory granules and GH cell subpopulations contained in pituitary glands of humans and rodents. GH activities in different electrophoresis fractions were measured by immunoassay or bioassay, viz., measurement of chondrocyte proliferation in the tibial growth plate of the hypophysectomized rat. Using FFE we discovered a peptide in human post mortem pituitary tissue and cryopoor human plasma that is active in the tibial line bioassay, is inactive in a GH immunoassay, and is neither GH nor a GH fragment. This peptide, called tibial peptide, has high anodal mobility and is readily separable from GH by FFE. Its molecular mass is approximately 5 kD. It is particularly rich in glycine. A partial amino acid sequence (residues 9-25) in the middle region of the peptide shows that 9 of the 16 residues are nonpolar. On the basis of results from other FFE experiments, using either GH-containing secretory granules or GH-producing cells, we believe that the peptide is stored within the secretion granule of a subpopulation of GH cells. On the basis of recent information elucidating the role of C peptide contained in the insulin storage granule of the pancreatic cell, we propose that the tibial peptide serves a similar role in the GH cell. Thus, not only may tibial peptide aid in proper alignment of disulfide bonds between GH monomers in the secretory granule, but, like the C peptide, it also appears to have biologic activity in its own right.  相似文献   

7.
Jing M  Bowser MT 《Lab on a chip》2011,11(21):3703-3709
A micro free flow electrophoresis (μFFE) device was used to select DNA aptamers for human immunoglobulin E (IgE). The continuous nature of μFFE allowed 1.8 × 10(14) sequences to be introduced over a period of 30 min, a 300-fold improvement in library size over capillary electrophoresis based selections (CE-SELEX). Four rounds of selection were performed within four days. Aptamers with low nM dissociation constants for IgE were identified after a single round of μFFE selection.  相似文献   

8.
The requirement for prefractionation in proteomic analysis is linked to the challenge of performing such an analysis on complex biological samples and identifying low level components in the presence of numerous abundant housekeeping and structural proteins. The employment of a preliminary fractionation step results in a reduction of complexity in an individual fraction and permits more complete liquid chromatography/mass spectrometry (LC/MS) analysis. Free flow electrophoresis (FFE), a solution-based preparative isoelectric focusing technique, fractionates and enriches protein fractions according to their charge differences and is orthogonal in selectivity to the popular reversed phase high performance liquid chromatography (HPLC) fractionation step. In this paper, we explored the advantages of a combination of FFE and liquid chromatography/mass spectrometry to extend the dynamic range of a proteomic analysis of a complex cell lysate. In this study, the whole cell lysate of a chronic myelogeneous leukemia cell line, K562/CR3, was prefractionated by FFE into 96 fractions spanning pH 3-12. Of these, 35 fractions were digested with trypsin and then analyzed by LC/MS. Depending on the algorithm used for peptide assignment from MS/MS data, at least 319 proteins were identified through database searches. The results also suggested that pI could serve as an additional criterion besides peptide fragmentation pattern for protein identification, although in some cases, a pI shift might indicate post-translational modification. In summary, this study demonstrated that free flow electrophoresis provided a useful prefractionation step for proteomic analysis and when combined with LC/MS allowed the identification of significant number of low level proteins in complex samples.  相似文献   

9.
Protein separation can be achieved with different modes of capillary electrophoresis, such as with capillary gel electroporesis (CGE) or with capillary zone electrophoresis (CZE). CZE protein mapping of peanut extract was approached in four different ways, combining neutral-coated or multilayer-coated capillaries with pHs well over or under the isoelectric point range of the proteins of interest. At acidic pHs, the mobility ranges of the major peanut allergens Ara h1, Ara h2, Ara h3, and Ara h6 were identified. Although the pH is a major factor in CZE separation, buffers with different compositions but with the same pH and ionic strength showed significantly different resolutions. Different components of the electrolyte were studied in a multifactorial design of experiment. CE-SDS and CZE proved to be suitable for protein mapping and we were able to distinguish different batches of peanut extract and burned peanut extract.  相似文献   

10.
As an effective separation tool, free-flow electrophoresis has not been used for purification of low-abundance protein in complex sample matrix. Herein, lysozyme in complex egg white matrix was chosen as the model protein for demonstrating the purification of low-content peptide via an FFE coupled with gel fitration chromatography (GFC). The crude lysozyme in egg while was first separated via free-flow zone electrophoresis (FFZE). After that, the fractions with lysozyme activity were condensed via lyophilization. Thereafter, the condensed fractions were further purified via a GFC of Sephadex G50. In all of the experiments, a special poly(acrylamide- co-acrylic acid) (P(AM-co-AA)) gel electrophoresis and a mass spectrometry were used for identification of lysozyme. The conditions of FFZE were optimized as follows: 130 μL/min sample flow rate, 4.9 mL/min background buffer of 20 mM pH 5.5 Tris-Acetic acid, 350 V, and 14 °C as well as 2 mg/mL protein content of crude sample. It was found that the purified lysozyme had the purity of 80% and high activity as compared with its crude sample with only 1.4% content and undetectable activity. The recoveries in the first and second separative steps were 65% and 82%, respectively, and the total recovery was about 53.3%. The reasons of low recovery might be induced by diffusion of lysozyme out off P(AM-co-AA) gel and co-removing of high-abundance egg ovalbumin. All these results indicated FFE could be used as alternative tool for purification of target solute with low abundance.  相似文献   

11.
Humic and fulvic acids from various sources have been shown to give different electropherograms by capillary zone electrophoresis (CZE), depending on the pH of the electrolyte. This CZE work is extended here through investigations involving the titration of humic and fulvic acids with Fe(III) and Cu(II) cations. As increasing amounts of these cations were added to the humic substances (HUS), flocculation of metal-humic complexes occurred. This is believed to be caused by binding of the metal cations with negative carboxyl and phenolic sites on the HUS, resulting in a decrease of the repulsive forces that keep the HUS in a conformation more suitable for water solubility. The flocculated complexes were separated from the supernatant by centrifugation, and the supernatants were characterized as to total organic carbon (TOC) content, molecular weight (MW) using gel permeation chromatography, and average electrophoretic mobility (AEM) using CZE. The extent of flocculation correlated with both TOC and quantitative CZE measurements. The MW of the HUS remaining in solution actually decreased, presumably because of precipitation of larger molecules as they became insoluble because of reactions with the metals. Humic acids showed total precipitation of TOC with both metals at a concentration equivalent to their measured acidity. CZE demonstrated that certain fulvic acid fractions (low molecular weight phenolic acids) remained in solution even at high metal concentrations. In summary, changes in electrophoretic behavior of the soluble HUS could be related to changes in charge-to-mass ratios (charge densities) of both humic and fulvic acids with increasing metal cation concentration (neutralization). The copper treated HUS showed changes in their electrophoretic behavior even at low metal concentrations before flocculation, whereas the iron treated HUS flocculated uniformally over the range of added iron without significant changes in AEM. Thus these changes in CZE patterns illustrate different specific binding sites of the HUS for each metal.  相似文献   

12.
The use of capillary zone electrophoresis (CZE) and capillary zone electrophoresis/mass spectrometry (CZE/MS) has been demonstrated, in principle, for the separation of nicotine and nicotine metabolites. The buffer system developed for separation and detection by CZE/UV was modified for use in CZE/MS analysis. Several of the metabolites are isobaric and tandem mass spectrometric (MS/MS) techniques have been used to differentiate such analytes.  相似文献   

13.
Humic and fulvic acids from various sources have been shown to give different electropherograms by capillary zone electrophoresis (CZE), depending on the pH of the electrolyte. This CZE work is extended here through investigations involving the titration of humic and fulvic acids with Fe(III) and Cu(II) cations. As increasing amounts of these cations were added to the humic substances (HUS), flocculation of metal-humic complexes occurred. This is believed to be caused by binding of the metal cations with negative carboxyl and phenolic sites on the HUS, resulting in a decrease of the repulsive forces that keep the HUS in a conformation more suitable for water solubility. The flocculated complexes were separated from the supernatant by centrifugation, and the supernatants were characterized as to total organic carbon (TOC) content, molecular weight (MW) using gel permeation chromatography, and average electrophoretic mobility (AEM) using CZE. The extent of flocculation correlated with both TOC and quantitative CZE measurements. The MW of the HUS remaining in solution actually decreased, presumably because of precipitation of larger molecules as they became insoluble because of reactions with the metals. Humic acids showed total precipitation of TOC with both metals at a concentration equivalent to their measured acidity. CZE demonstrated that certain fulvic acid fractions (low molecular weight phenolic acids) remained in solution even at high metal concentrations. In summary, changes in electrophoretic behavior of the soluble HUS could be related to changes in charge-to-mass ratios (charge densities) of both humic and fulvic acids with increasing metal cation concentration (neutralization). The copper treated HUS showed changes in their electrophoretic behavior even at low metal concentrations before flocculation, whereas the iron treated HUS flocculated uniformally over the range of added iron without significant changes in AEM. Thus these changes in CZE patterns illustrate different specific binding sites of the HUS for each metal.  相似文献   

14.
Capillary zone electrophoretic (CZE) separations and mass spectrometric analysis of salmon calcitonin and related analogues were performed to generate electrophoresis and mass fingerprints for quality control of the recombinant polypeptide pharmaceutical salmon calcitonin. The calcitonins and their corresponding tryptic digests were successfully separated by CZE at low pH in fused silica capillaries dynamically modified with poly-cationic polymers. The poly-cationic modified inner surface of the fused silica capillaries generated a strong anionic electroosmotic flow (EOF). Analytes of negative, neutral, and positive charge were all swept through the capillary toward the positive electrode. Compared to Polybrene-coated capillaries, capillaries coated with PEI showed a markedly slower but much more stable electroosmotic flow. The migration order of the analytes was predicted by comparing approximate values of the charge to (molecular mass)2/3 ratios. The predicted migration order was confirmed by off-line analysis of CZE fractions with matrix-assisted laser-desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS).  相似文献   

15.
The separation of Suwannee River natural organic matter (NOM) with capillary zone electrophoresis hyphenated to electrospray ionization-mass spectrometry (CZE-ESI-MS) is presented. The obtained electropherograms and signal distributions are comparable to the mobility distributions obtained with more classical UV detection. A direct comparison of the results was possible with free-flow electrophoresis (FFE), which allows an upscaling of the CZE method and the analysis of the collected fractions in an off-line modus with flow-injection electrospray ionization-mass spectrometry (FI-ESI-MS). The changes of the m/z distributions with mobility are very similar with both methods and show a decrease of the m/z with increasing electrophoretic mobility in the humic hump at alkaline pH; superimposed on this hump a low-molecular-weight fraction migrates at lower mobility. The analysis of benzene carboxylic acids, glycerrhycic acid as well as oligomers of polystyrene sulfonic acid and polyacrylic acid additionally illustrates possible fragmentation, formation of adducts and multiplicity of the charges of the molecules prior to MS detection. These hardly controllable difficulties add a challenge to the interpretation of the obtained m/z distributions of NOM in terms of charge and mass distributions of molecules present in the NOM mixture.  相似文献   

16.
A large-scale free-flow electrophoresis (LS-FFE) is often too large for cell separation of lab scale, whereas micro-FFE (μFFE) has great difficulty in cell isolation due to easy blockage by cell accumulation in μFFE. In this study, a mid-scale FFE (MS-FFE) is developed for cell and protein separations. The volume of the separation chamber (70×40×0.1-0.8 mm) is from 280 μL to 2.24 mL, much lower than that in an LS-FFE but higher than that in a μFFE. Gravity is used for uniform flow of the background buffer only via a single pump with 16 channels and the sample is injected via an adjuster originally used for clinical intravenous injection. The experiments reveal that the hydrodynamic and electrohydrodynamic flows are much stable, and the Joule heat can be effectively dispersed without obvious positive or negative deviation as shown by the omega plots. By the device, Escherichia coli and Staphylococcus aureus, which easily accumulate to block μFFE and are separated with difficulty due to their same negative charges carried, can be well isolated under the conditions of 4.5 mM pH 8.5 Tris-boric buffer (4.5 mM Tris, 4.5 mM boric acid) with 0.10 mM ethylene diamine tetraacetic acid and 5% m/v sucrose, 200 μL/min, 800 V, and sample injection via inlet 4. The mid-scale FFE device could also be used for the separation of three model proteins of horse heart cytochrome c, myoglobin and bovine serum albumin. The device has clear significance for mid-scale separation of cells and proteins.  相似文献   

17.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

18.
A method for separation and determination of polyphenols in wine by capillary zone electrophoresis (CZE) without any preconcentration step is described. The sensitivity and limits of detection for gentisic and p-coumaric acid are better than those previously published. The effect of a possible C18 solid-phase extraction prior to the CZE analysis was examined. The developed optimized method (without any extraction step) was applied to the analysis of wines from Tenerife, Canary Islands.  相似文献   

19.
We evaluated the 5-band Serum Proteins by Capillary Electrophoresis kit (Bio-Rad Laboratories, Hercules, CA, U.S.A.) on the BioFocus 2000 CE (Bio-Rad) against conventional agarose gel electrophoresis (AGE) (Helena Laboratories, Beaumont, TX, U.S.A.). Serum from 60 patients was initially screened by AGE and divided into three groups: 1) normal electrophoretic pattern (n = 36, mean total protein 67.7 g/L), 2) monoclonal/oligoclonal gammopathy (n = 14, mean total protein 78.8 g/L), and 3) polyclonal gammopathy (n = 10, mean total protein 77.4 g/L). These samples were concurrently analyzed on the BioFocus 2000. Intraassay and interassay CVs for the five fractions for a normal sample were 0.17-1.44% and 0.42-9.11%, respectively, and 0.21-3.37% and 0.29-3.61%, respectively, for a sample with monoclonal gammopathy. Correlation coefficients for albumin and the albumin/globulin (A/G) ratio were 0.8891 (albumin range 17-93 g/L) and 0.8276 (A/G ratio range 0.39-7.81), respectively. The A/G ratio alone could not discriminate between the three groups. Capillary zone electrophoresis (CZE) correctly identified 33 of 36 samples in the normal group, and 22 of 24 samples in the other two groups, giving a clinical sensitivity and specificity of 91.7%. Our preliminary evaluation shows that protein separation by CZE is a simple, rapid, and automated alternative to conventional AGE.  相似文献   

20.
Miniaturizing free-flow electrophoresis - a critical review   总被引:1,自引:0,他引:1  
Free-flow electrophoresis (FFE) separation methods have been developed and investigated for around 50 years and have been applied not only to many types of analytes for various biomedical applications, but also for the separation of inorganic and organic substances. Its continuous sample preparation and mild separation conditions make it also interesting for online monitoring and detection applications. Since 1994 several microfluidic, miniaturized FFE devices were developed and experimentally characterized. In contrast to their large-scale counterparts microfluidic FFE (mu-FFE) devices offer new possibilities due to the very rapid separations within several seconds or below and the requirement for sample volumes in the microliter range. Eventually, these mu-FFE systems might find application in so-called lab-on-a-chip devices for real-time monitoring and separation applications. This review gives detailed information on the results so far published on mu-FFE chips, comprising its four main modes, namely free-flow zone electrophoresis (FFZE), free-flow IEF (FFIEF), free-flow ITP (FFITP), and free-flow field-step electrophoresis (FFFSE). The principles of the different FFE modes and the basic underlying theory are given and discussed with special emphasis on miniaturization. Different designs as well as fabrication methods and applied materials are discussed and evaluated. Furthermore, the separation results shown indicate that similar separation quality with respect to conventional FFE systems, as defined by the resolution and peak capacity, can be achieved with mu-FFE separations when applying much lower electrical voltages. Furthermore, innovations still occur and several approaches for hyphenated, more integrated systems have been proposed so far, some of which are discussed here. This review is intended as an introduction and early compendium for research and development within this field.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号