首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A substantial demand currently exists for analytical methods affording the determination of very low concentrations of analytes in complex matrices, such as those of environmental and biological samples, as simply as possible. However, the pretreatment of complex samples, which is unavoidable prior to CE-MS analysis, is usually complicated and time-consuming. In this work, we used voltage-assisted SPE for the first time as an alternative to conventional treatments for preconcentrating and purifying analytes. To this end, we used a simple flow system coupled on-line to CE-MS equipment. The system is quite robust and provides reproducible peak areas (the precision ranges from 2.5 to 3.8%). Also, it provides increased sensitivity affording the determination of trace amounts (nanogram per liter levels) of analytes in only a few milliliters of sample. The proposed system was applied to the determination of members of two compound families (viz. tetracyclines and amines).  相似文献   

2.
Metabolome analysis by capillary electrophoresis-mass spectrometry   总被引:1,自引:0,他引:1  
Monton MR  Soga T 《Journal of chromatography. A》2007,1168(1-2):237-46; discussion 236
Capillary electrophoresis (CE)-mass spectrometry (MS), as an analytical platform, has made significant contributions in advancing metabolomics research, if still limited up to this time. This review, covering reports published between 1998 and 2006, describes how CE-MS has been used thus far in this field, with the majority of the works dealing with targeted metabolite analyses and only a small fraction using it in the comprehensive context. It also discusses how some of the key features of CE-MS were exploited in selected metabolomic applications.  相似文献   

3.
Nonaqueous background electrolytes broaden the application of capillary electrophoresis displaying altered separation selectivity and interactions between analytes and buffer additives compared to aqueous background electrolytes. In addition, nonaqueous capillary electrophoresis (NACE) appears to be ideally suited for online coupling with mass spectrometry due to the high volatility and low surface tension of many organic solvents. Despite these advantages and an increasing use of nonaqueous background electrolytes in CE, coupling of NACE to mass spectrometry has not yet been applied very often to date. The present review summarizes the applications of online NACE-MS with regard to the analysis of drugs, stereoisomers, peptides, alkaloids, polymers and others. A brief discussion of solvent effects in NACE and pH of nonaqueous background electrolyte systems is also presented.  相似文献   

4.
Mechref Y 《Electrophoresis》2011,32(24):3467-3481
The high structural variation of glycan derived from glycoconjugates, which substantially increases with the molecular size of a protein, contributes to the complexity of glycosylation patterns commonly associated with glycoconjugates. In the case of glycoproteins, such variation originates from the multiple glycosylation sites of proteins and the number of glycan structures associated with each site (microheterogeneity). The ability to comprehensively characterize highly complex mixture of glycans has been analytically stimulating and challenging. Although the most powerful MS and MS/MS techniques are capable of providing a wealth of structural information, they are still not able to readily identify isomeric glycan structures without high-order MS/MS (MS(n) ). The analysis of isomeric glycan structures has been attained using several separation methods, including high-pH anion-exchange chromatography, hydrophilic interaction chromatography and GC. However, CE and microfluidics CE (MCE) offer high separation efficiency and resolutions, allowing the separation of closely related glycan structures. Therefore, interfacing CE and MCE to MS is a powerful analytical approach, allowing potentially comprehensive and sensitive analysis of complex glycan samples. This review describes and discusses the utility of different CE and MCE approaches in the structural characterization of glycoproteins and the feasibility of interfacing these approaches to MS.  相似文献   

5.
6.
CE-MS has evolved into a strong alternative to LC-MS. Most of CE-MS applications deal with characterization and identification. However, quantitative aspects have gained importance in, e.g., pharmaceutical and biotechnological applications. Here we summarize and evaluate various methodological aspects in order to achieve sensitive and reproducible results. Similar to LC-MS, aspects of matrix influence on the electrospray process need to be carefully addressed when quantitative results are intended by CE-MS. Due to a more complicated coupling special emphasis needs to be put on the CE-MS interface. Generally linearity over more than three orders of magnitude can be achieved by CE-ESI-MS. Furthermore, a literature survey has been performed in order to give an overview over quantitative measurements performed by CE-MS. The precision can be doubled when changing from a structural related to an isotopically labeled internal standard. Thus a level of precision better than 5% RSD can be achieved.  相似文献   

7.
毛细管电泳-质谱联用技术的新进展   总被引:1,自引:0,他引:1  
周志贵  李珉  白玉  刘虎威 《色谱》2009,27(5):598-608
毛细管电泳-质谱(CE-MS)联用技术综合了CE的高效分离能力、广泛的样品适应性和MS的高灵敏度、可提供结构信息等优势,已发展成为一种重要的分离分析手段。本文对近几年来CE-MS联用接口技术的发展作一简单介绍,并对CE-MS在生命分析、食品药品分析等领域的一些应用进展予以综述。  相似文献   

8.
A method for the determination of nucleotides based on pressure-assisted capillary electrophoresis-electrospray ionization mass spectrometry (PACE-MS) is described. To prevent multi-phosphorylated species from adsorbing onto the fused-silica capillary, silanol groups were masked with phosphate ions by preconditioning the capillary with the background electrolyte containing phosphate. During preconditioning, nebulizer gas was turned off to avoid contamination of MS detector with phosphate ions. To detect nucleotides using the CE positive mode at a pH 7.5, it was necessary to apply air pressure to the inlet capillary during electrophoresis to supplement the electroosmotic flow (EOF) toward the cathode. Moreover, we exchanged the running electrolyte every analysis using the buffer replenishment system to obtain the required reproducibility. Under the optimized conditions, 14 phosphorylated species such as nucleotides, nicotinamide-adenine dinucleotides and coenzyme A (CoA) compounds were well determined in less than 20 min. The relative standard deviations (n=6) of the method were better than 0.9% for migration times and between 1.7% and 8.1% for peak areas. The detection limits for these species were between 0.5 and 1.7 micromol/L with pressure injection of 50 mbar for 30 s (30 nL) at a signal-to-noise ratio of 3. This approach is robust and quantitative compared to the previous method, and its utility is demonstrated by the analysis of intracellular nucleotides and CoA compounds extracted from Escherichia coli wild type, pfkA and pfkB knockout mutants. The methodology was used to suggest that pfkA is the main functional enzyme.  相似文献   

9.
10.
Capillary electrophoresis-mass spectrometry was applied to the separation of several anionic dyes containing copper(II), chromium(III), or cobalt(III) as part of the dye molecule. The dyes were separated using a 110 cm x 50 microm uncoated fused-silica capillary and a 5 mM ammonium acetate buffer (pH 9) containing 40% acetonitrile. Excellent separation efficiencies (N = 500,000 plates/column) and low detection limits of 20-50 pg (selected ion monitoring, S/N = 10) were achieved. Mass spectra were acquired at different cone voltages. At low cone voltages (low collision energies), sensitivity was maximized and the mass spectra contained only signals of the (multiply charged) molecular ions and low levels of sodium ion and proton adducts. At higher cone voltages, the 2:1 (ligand:metal) chromium and cobalt dyes showed losses of one of the two dye ligands, accompanied by a reduction of the metal. The copper dyes showed signals due to loss of SO2 and SO3-, but no release of metal. Azo cleavage, otherwise typical of azo dyes, was not observed with the metallized dyes.  相似文献   

11.
A capillary electrophoresis-mass spectrometry method was used to analyze naphthenic acids in produced water samples. It was possible to detect cyclopentanecarboxylic, benzoic, cyclohexanebutyric, 1-naphthoic, decanoic, 3,5-dimethyladamantane-1-carboxylic, 9-anthracenecarboxylic, and pentadecanoic acids within ca. 13 min using a buffer composed of 40 mmol/L ammonium hydroxide, 32 mmol/L acetic acid and 20% v/v isopropyl alcohol, pH 8.6. The proposed method showed good repeatability, with relative standard deviation (RSD) values of 6.6% for the sum of the peak areas and less than 2% for the analysis time. In the interday analysis, the RSD values for the sum of the peak areas and migration time were 10.3% and 10%, respectively. The developed method demonstrated linear behavior in the concentration range between 5 and 50 mg/L for benzoic, decanoic, 3,5-dimethyladamantane-1-carboxylic and 9-anthracenecarboxylic acids, and between 10 and 50 mg/L for cyclopentanecarboxylic, cyclohexanebutyric, 1- naphthoic, and pentadecanoic acids. The detection limits values ranged from 0.31 to 1.64 mg/L. Six produced water samples were analyzed and it was possible to identify and quantify cyclopentanecarboxylic, benzoic, cyclohexanebutyric, and decanoic acids. The concentrations varied between 4.8 and 98.9 mg/L, proving effective in the application of complex samples.  相似文献   

12.
Propolis is a resinous hive product rich in antioxidant compounds. Capillary electrophoresis coupled to mass spectrometric detection can provide selective information about the analytes present in complex extracts of propolis and has turned out to be an attractive alternative to HPLC methods. Therefore, a CE-ESI-MS method has been developed for the analysis of antioxidant compounds obtained from propolis. For this purpose, different electrophoretic parameters such as the nature, pH, and concentration of the separation buffer, as well as electrospray parameters (dry gas temperature and flow, nebulising gas pressure, and make-up flow) have been carefully optimised. Different phenolic compounds (e.g. pinobanksin 3-acetate, naringenin, pinocembrin, chrysin, daidzein, quercetin 3',7-dimethyl ether, apigenin, and kaempferid) could be detected. To confirm the identity of the phenolic compounds in propolis extracts, accurate mass data of the molecular ions were obtained by TOF MS. Limits of detection ranging from 6 mg/100 g of raw propolis for chrysin to 58 mg/ 100 g of raw propolis for luteolin, were obtained.  相似文献   

13.
王芳  王松  丛海林  于冰 《色谱》2020,38(9):1013-1021
毛细管电泳-质谱(CE-MS)联用技术具有高灵敏度、高分析效率、低样品损耗等优点,在强极性和带电荷的物质分析中具有明显优势,已广泛应用于生命科学、医学、药学等多个领域。在过去的十几年,影响其应用的主要因素包括系统的稳定性、实验的可重复性、数据的准确性等。为解决现有问题,进一步拓展其应用,研究人员在技术设计和改进等方面做了大量工作。医学和分析化学领域的相关研究证明了CE-MS在代谢组学和蛋白质组学中的实用性。这篇文章综述了2015年以来,CE-MS在技术和应用方面的最新进展,为未来的技术发展及应用提供借鉴。为提高CE-MS的分析效率和数据可比性,该文对多个方面的研究进行了讨论,包括涂层与样品的相互作用、接口技术、运行参数和数据处理方法。文中关于复杂样品(组织、细胞、体液等)代谢组学/蛋白质组学的综述研究,使癌症病理分析、药物开发和疾病监测等分析数据更加可视化,为CE-MS临床分析应用提供借鉴。除了对CE-MS的最新发展进行综合评述外,还提出未来应加强3个方面的研究:(i)从样品前处理和分离技术方面优化分析方法;(ii)从毛细管涂层和接口技术方面调整分析技术;(iii)从临床研究和数据分析...  相似文献   

14.
The potential of capillary electrophoresis (CE) for the separation of peptides has been extensively demonstrated in the last decade. Their correct characterization and sequenciation is a difficult task that can be accomplished using CE-mass spectrometry (CE-MS). An important limitation of CE-MS is the buffer choice since it should provide an adequate CE separation without ruining the MS signal. In this work, a new strategy is used to help to solve this limitation based on the combination of two different methodologies. Namely, an ab initio semiempirical model that relates electrophoretic behavior of peptides to their sequence is first used to obtain in a fast and easy way adequate CE buffers compatible with MS analysis. Next, CE-MS is used to separate and characterize peptides via the determination of their relative molecular masses. The usefulness of this procedure is demonstrated analyzing in a single CE-MS run a group of 10 standard peptides of very different nature (i.e., relative molecular masses ranging from 132 to 1037 and isoelectric points ranging from 5.69 to 10.62). It is concluded that the use of this strategy can help to overcome the buffer limitation in CE-MS.  相似文献   

15.
Sample preparation is a crucial part of chemical analysis and in most cases can become the bottleneck of the whole analytical process. Its adequacy is a key factor in determining the success of the analysis and, therefore, careful selection and optimization of the parameters controlling sample treatment should be carried out. This work revises the different strategies that have been developed for sample preparation prior to capillary electrophoresis-mass spectrometry (CE-MS). Namely the present work presents an exhaustive and critical revision of the different samples treatments used together with on-line CE-MS including works published from January 2000 to July 2006.  相似文献   

16.
This paper describes several successful cost-effective attempts to couple capillary electrophoresis (CE) and mass spectrometry (MS) without make-up flow or nebulizing gas. An in-depth analysis of several interfaces using conductive spray tips was performed as well as an easy-to-prepare T-junction with direct electrode contact, the latter being the most robust interface. No coating is necessary and the spray voltage is applied through a gold wire positioned at the gap between the separation and spray capillaries. The T-junction interface is made by puncturing a small piece of transparent rubber. The on-line preconcentration CE-MS system allows immunoassay sensitivity, as is demonstrated by a calibration plot in the picomolar range for angiotensin II and gonadorelin. It also shows good reproducibility and has the ability of excellent automation. The secure electrical contact gives a constant spray quality, even with 100% aqueous separation buffers. The described setup has a wide applicability as is demonstrated by the analysis of larger peptides, such as insulin and cytochrome c. Detailed information is given on critical factors in the preparation of the described interfaces.  相似文献   

17.
The qualitative and quantitative betalain pigment content of two cultivars of prickly pear (Opuntia ficus-indica) fruits grown in southeastern Spain was evaluated. After methanolic extraction of crushed fruits, reversed-phase high-performance liquid chromatography and photodiode array detection were applied simultaneously for the separation, identification and quantification of these pigments. Two main pigments were obtained, which were identified as indicaxanthin (lambda(max) 484 nm) and betanin (lambda(max) 535 nm). Spectrophotometric evaluation of both pigments showed a yield of around 20-30 mg per 100 g of fresh pulp. When the influence of temperature (25 to 90 degrees C) on betacyanin pigment stability was investigated, the results revealed a substantial degree of thermodegradation at temperatures higher than 70 degrees C.  相似文献   

18.
迟忠美  杨丽 《色谱》2022,40(6):509-519
目前使用的绝大多数药物为手性化合物,它们具有相似的物理和化学性质,但药理活性不同,且常以外消旋混合物的形式存在,因此对手性化合物的分离在生物、环境、食品和医药等领域一直备受关注。与广泛使用的液相色谱-质谱(LC-MS)相比,毛细管电泳-质谱(CE-MS)作为一种新型分离分析技术,具有分离效率高、样品和试剂消耗量低、选择性高和分离模式多样化等诸多优势,已经发展成为手性分析领域中有广阔应用前景的分析方法之一。CE-MS结合了CE的高分离效率和低样品消耗以及MS的高灵敏度和强结构解析能力,在蛋白质组学和代谢组学等领域发挥了重要作用。CE杰出的手性拆分能力与MS优势的结合,亦使CE-MS成为实现手性化合物高效分离分析的完美组合。在过去的十几年里,基于不同CE-MS分离模式的高性能手性分析体系层出不穷,如电动色谱-质谱(EKC-MS)、胶束电动色谱-质谱(MEKC-MS)和毛细管电色谱-质谱(CEC-MS)等,并成功应用于医药、生物、食品和环境科学等领域的手性化合物分析。该文主要综述了2011~2021年,CE-MS在手性化合物分析领域的技术、手性选择剂(如改性环糊精和聚合物表面活性剂等)的使用以及在医药等领域应用方面的研究进展,并讨论了不同手性分析模式的局限性,为未来的CE-MS手性分离分析技术发展及应用提供借鉴。  相似文献   

19.
The potential of capillary electrophoresis combined with mass spectrometry for the simultaneous determination of two herbicides (glyphosate and glufosinate) and their metabolites (aminomethylphosphonic acid and methylphosphinicopropionic acid) as the native species is demonstrated utilising a simple microelectrospray interface. The interface uses the voltage applied to the CE capillary to drive separation and generate the electrospray, avoiding sample dilution associated with the use of a sheath liquid interface. The chemistry of the internal walls of the capillary has a marked influence on peak shape, and appropriate choice is essential to successful operation of the interface. A linear polyacrylamide coated capillary, which has no electroosmotic flow, gave best reproducibility, with precision of migration time and peak area in the range 1-2 and 7-12% RSD, respectively, for the four analytes. Limits of detection, low-pg on-column, are substantially better than for previous methods and calibration curves over the range 1-100 microM have R2 values greater than 0.97. The observed concentration limit of detection for glyphosate in water is 1 microM and for a water-acetone extract of wheat is 2.5 microM, allowing the underivatised herbicide to be detected at 10% of the maximum residue limit in wheat.  相似文献   

20.
We report an on-line sample preconcentration technique based on dynamic pH junction in capillary electrophoresis-mass spectrometry (CE-MS). For peptide analysis, the samples were dissolved in a solution with higher pH than the background solution (BGS), and were injected into the capillary as a long plug. The pH difference between the sample matrix and BGS caused changes in analytes' mobilities during electrophoresis, resulting in narrowing of their bands at the boundary. Around 550-1000-fold sensitivity enhancement could be achieved in terms of peak intensity without degrading peak shape and resolution. This technique is easy to perform and will be useful for peptide mass fingerprinting in protein analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号