李华  张树林  张朝祥  孔祥燕  谢晓明 《中国物理 B》2016,25(6):68501-068501
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.  相似文献   

2.
The calculation and measurement of field parameters and their derivatives play a very important role in designing and constructing saddle-shaped bipolar-magnetic coils [1]. In this article, new distribution function Fn and its derivatives along z-axis are defined, formularized and presented. Calculation and error analysis for the magnetic field parameters of a standard saddle coil are conducted and presented using the formulas. It is shown that the method and formulas can be used in calculating the field parameters, derivatives and the magnetic vector H for the bipolar-magnetic coils.  相似文献   

3.
I.IntroductionInlate198()'s,thestudiesonactivenoisecontrolhavebeengraduallyturnedfromtheductsandopenspacestothemorepracticaIenclosedsoundfields.SomespeciaIworkinaccordancewiththeactiveattenuationofcabinnoisehasstartedwiththeoreticalmechanisms,systemdesignandtransducerdevelopmellt.Intensivereflectionsandtheformedstandingwavedistributioni11al1enclosedsoundfieldarealwaysthemaindifficultiesforactivenoisecontrolinthesecases.Ontheotherhand,normalmoderesponseofthefieldalsoimplementsanewmethod,theap…  相似文献   

4.
We measured cyclic losses in a superconducting wire, carrying alternating transport current, simultaneously exposed to an alternating transverse magnetic field. Samples of Bi-2223 Ag-sheathed tapes have configuration of a double-layer non-inductive coil, which itself is a pickup coil to measure the AC losses. Potential taps were attached to both terminals of the sample coil. The external field was applied along the axis of the sample coil. In this procedure, we can estimate an averaged Poynting's vector on a cylindrical surface between the two layers by means of signals from a pair of the potential taps and from pickup coils for the external magnetic field and the transport current. We can also measure a magnetization and an extended transport-current components of AC losses in addition to a total cyclic loss for a combined alternating external field and transport current. Obtained results are compared with numerical predictions of the critical state model taking into account the magnetic field dependence of critical current density.  相似文献   

5.
Hirata S  Kurosawa MK 《Ultrasonics》2012,52(7):873-879
Real-time distance measurement of a moving object with high accuracy and high resolution using an ultrasonic wave is difficult due to the influence of the Doppler effect or the limit of the calculation cost of signal processing. An over-sampling signal processing method using a pair of LPM signals has been proposed for ultrasonic distance and velocity measurement of moving objects with high accuracy and high resolution. The proposed method consists of cross correlation by single-bit signal processing, high-resolution Doppler velocity estimation with wide measurement range and low-calculation-cost Doppler-shift compensation. The over-sampling cross-correlation function is obtained from cross correlation by single-bit signal processing with low calculation cost. The Doppler velocity and distance of the object are determined from the peak interval and peak form in the cross-correlation function by the proposed method of Doppler velocity estimation and Doppler-shift compensation. In this paper, the proposed method of Doppler-shift compensation is improved. Accuracy of the determined distance was improved from approximately within ±140 μm in the previous method to approximately within ±10 μm in computer simulations. Then, the proposed method of Doppler velocity estimation is evaluated. In computer simulations, accuracy of the determined Doppler velocity and distance were demonstrated within ±8.471 mm/s and ±13.87 μm. In experiments, Doppler velocities of the motorized stage could be determined within ±27.9 mm/s.  相似文献   